Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: CANNON Instrument Company
Description: The RX-620SA determines total sulfur in petroleum products using energy-dispersive X-ray fluorescence (EDXRF). Testing is quick, non-destructive, economical and accurate. The instrument comes with a 12 position autosampler for unattended processing.
- Display & Special Features: Digital Readout
- Test Media: Fuel
- Features: Fuel Oil, Sulfur Content
- Mounting / Loading Options: Laboratory / Batch
-
Supplier: Analytical Systems Int’l. Keco
Description: parts and supplies, Analytical Systems International (ASI) has met these requirements with their proven microprocessor based analyzer. The Model 1700 System measures total sulfur by hydrogenation similar to that as described in ASTM Method D3031, D4084-82, D4468-85 and 4045-81. The
- Operating Temperature: 41 to 122 F
- Electrical Outputs: Analog Current, Switch
- Instrument Type: Analyzer
- Features: Audible or Visual Alarms, Controller
-
Supplier: Analytical Systems Int’l. Keco
Description: The petrochemical, gas processing, & gas pipeline industry has for many years required an accurate, dependable, low maintenance, and cost effective sulfur analyzer for quality and process control purposes. With over twenty years of experience in developing and manufacturing sulfur
- Operating Temperature: 41 to 122 F
- Electrical Outputs: Analog Current, Switch
- Instrument Type: Analyzer
- Features: Audible or Visual Alarms, Controller
-
-
Supplier: Analytical Technology, Inc.
Description: The ATI Model A15/79 Total Chlorine Monitor uses the standard iodometric method for the determination of total chlorine in highly contaminated samples. A unique sensing technique is used to determine total chlorine concentration, while minimizing system maintenance requirements.
-
Supplier: CANNON Instrument Company
Description: The RX-630SA determines total sulfur in petroleum products using energy-dispersive X-ray fluorescence (EDXRF). Testing is quick, non-destructive, economical and accurate. The instrument comes with a 12 position autosampler for unattended processing.
-
Supplier: HORIBA Instruments, Inc.
Description: The MEXA 1170 SX is a new instrument used to measure sulfur for after treatment and transient lubricant oil consumption. The analyzer uses ultraviolet fluorescence (UVF) for detection and it can be operated in a total sulfur mode, analyzing sulfur oxides, hydrogen
- Display Type: Digital Display
- User Controls: Digital Front Panel
- Form Factor: In-Situ / Field
- Water Quality Parameters: Measures Conductivity / Dissolved Solids
-
Supplier: Analytical Systems Int’l. Keco
Description: parts and supplies, Analytical Systems International (ASI) has met these requirements with their proven microprocessor based analyzer. The Model 1700 System measures total sulfur by hydrogenation similar to that as described in ASTM Method D3031, D4084-82, D4468-85 and 4045-81. The
- Operating Temperature: 41 to 122 F
- Electrical Outputs: Analog Current, Switch
- Instrument Type: Analyzer
- Features: Audible or Visual Alarms, Controller
-
Supplier: ASTM International
Description: 1.1 This test method covers the individual determination of total fluorine, chlorine and sulfur in aromatic hydrocarbons and their mixtures. Samples containing 0.10 to 10 mg/kg of each element can be analyzed. 1.2 This method can be applied to sample concentrations outside the range of
-
Supplier: CSA Group
Description: ISO 19579:2006 specifies an alternative method of determining the total sulfur content of hard coal, brown coal, and lignite by high-temperature combustion and infrared absorption using commercially available instruments. This method has been shown to be applicable to coal
-
Description: ISO 19579:2006 specifies an alternative method of determining the total sulfur content of hard coal, brown coal, and lignite by high-temperature combustion and infrared absorption using commercially available instruments. This method has been shown to be applicable to coal
-
Supplier: ASTM International
Description: highest level sample in the round robin, 4.6 weight % total sulfur. Note 1: Instrumentation covered by this test method can vary in sensitivity. The applicability of the test method at sulfur concentrations below 3 mg/kg may be determined on an individual basis for WDXRF
-
Supplier: ASTM International
Description: sulfur species. Unknown sulfur compounds are measured as mono-sulfur containing compounds. Total sulfur content of a sample can be found by summing up sulfur content present in all sulfur species. 1.4 This method is not a Detailed Hydrocarbon Analysis
-
Supplier: ASTM International
Description: sulfur species. Unknown sulfur compounds are measured as mono-sulfur containing compounds. Total sulfur content of a sample can be found by summing up sulfur content present in all sulfur species. 1.4 This method is not a Detailed Hydrocarbon Analysis
-
Supplier: InspectorTools
Description: humidity, and up to 5 additional plug-and-play ‘smart’ sensors, including carbon dioxide (CO2), carbon monoxide (CO), oxygen (O2), formaldehyde (HCHO), total volatile organic compounds (TVOCs), nitrogen dioxide (NO2), sulfur dioxide (SO2), ammonia (NH3), hydrogen sulfide (H2S) and
-
Supplier: InspectorTools
Description: humidity, and up to 5 additional plug-and-play ‘smart’ sensors, including carbon dioxide (CO2), carbon monoxide (CO), oxygen (O2), formaldehyde (HCHO), total volatile organic compounds (TVOCs), nitrogen dioxide (NO2), sulfur dioxide (SO2), ammonia (NH3), hydrogen sulfide (H2S) and
-
Supplier: InspectorTools
Description: humidity, and up to 5 additional plug-and-play ‘smart’ sensors, including carbon dioxide (CO2), carbon monoxide (CO), oxygen (O2), formaldehyde (HCHO), total volatile organic compounds (TVOCs), nitrogen dioxide (NO2), sulfur dioxide (SO2), ammonia (NH3), hydrogen sulfide (H2S) and
-
Supplier: Emerson Automation Solutions – Rosemount
Description: provides instant online analysis of the sample with unsurpassed measurement accuracy, performance and repeatability. Discover why QCL’s patented technology is changing the industry. Easy Startup and Commissioning with Lowest Total Cost of Ownership Solid-state components and unique modular
- Operating Temperature: -4 to 131 F
- Operating Humidity: 10 to 95 %
- Measurement Type: %Volume, Trace
- Gas Types: Ammonia (NH3), Carbon Dioxide (CO2), Carbon Monoxide (CO), Nitric Oxide (NO), Nitrogen Dioxide (NO2), Nitrogen Oxides (NxOx), Oxygen (O2), Sulfur Dioxide (SO2)
-
Supplier: SAE International
Description: noted the measurement of oxygen (O 2 ) is generally accepted as essential for assessing data quality, but is not covered by this ARP. Sulfur dioxide (SO 2 ) is normally not measured using conventional systems but is calculated from fuel sulfur content. Again this is not covered by this
Find Suppliers by Category Top
Featured Products Top
-
– Secondary operations can transform a simple tube into the part needed. CNC Machining, cutting, welding, bending and precision grinding are among the operations to tailor your tube to the part you need. Total Cost (read more)
Browse Stainless Steel Alloys Datasheets for Eagle Stainless Tube & Fabrication, Inc. -
– Secondary operations can transform a simple tube into the part needed. CNC Machining, cutting, welding, bending and precision grinding are among the operations to tailor your tube to the part you need. Total Cost – When (read more)
Browse Metal Tubes Datasheets for Eagle Stainless Tube & Fabrication, Inc. -
, partially burned fuels, varnish, and lacquers. All of these particles contaminate the oil. Sulfur Oxides (Sox) are common gases with sulfurous fuels (diesel, liquid fuel distillates, heavy fuel oil); Nitrous Oxides (NOx) are more pronounced with Natural gas (CNG, LNG, Propane) fueled engines. Hydrocarbon (read more)
Browse Oil Sensors and Analyzers Datasheets for AMETEK Spectro Scientific -
edge cases. They are standard headaches in LSR work. So when the machine platform is also large, expensive, fragmented, and difficult to learn, the total burden becomes even heavier. That is why many teams delay (read more)
Browse Molding Machines Datasheets for APSX, LLC
Conduct Research Top
-
Total Sulfur Analysis in Natural Gas with the 700XA Gas Chromatograph
A fundamental requirement for gas safety and contract sale of natural gas is to measure the amount of H2S and Total Sulfur. The level of these contaminants and sulfur-based odorants is strictly controlled to avoid equipment damage and risk to site personnel in transmission and distribution
-
The State of the Art In Gas Cleaning for the Fertilizer Industry
The fertilizer industry has earned recognition for having contributed directly to increase world grain yields in the past century. Based on the conservative estimate of the world population growth, total fertilizer use in the future is expected to grow more than 200 million tons from the current
More Information Top
-
Organic sulphur fixation in freshwater lake sediments and the implication for US ratios
Zimmermann for their help with sample collection and analyses and G. Schroder for the use of his total sulphur instrument .
-
Data summary report for M.W. Kellog zinc titanite test series: ZTSC-01, ZTSC-02, ZTSC-03, ZTSC-04, ZTSC-05, ZTSC-06, ZTSC-07, ZTSC-08, ZTMC-01, ZTMC-02, ZTMC-0...
Total sulfur analyses were performed by EG&G utilizing a LECO Model SC-32 Total Sulfur Analyzer instrument .
-
Bacterial ecology of a young equatorial hydroelectric reservoir (Petit Saut, French Guiana)
H2S concentrations were determ- ined by oxidation at 800 ◦C with a total reduced sulphur instrument (Environment S.A., AF41M).
-
Atmospheric Sulfur Analysis Using Rateometric Colorimetry
KEY WORDS: sulfur, hydrogen sulfide, total sulfur , instruments , monitors, colorime- try, air pollution, measurement, atmospheric sulfation .
-
Data summary report for M.W. Kellog zinc ferrite test ZFMC-01 CRADA 92-008. Final report
Total sulfur analyses were performed by EG&G uti:Lizing a LECO Model SC-32 Total Sulfur Analyzer instrument .
-
Phosphorus biogeochemistry in sediments of high altitude lakes, Kumaun Himalayas, India
The USGS standard SCO-1 was used to calibrate the instrument for total sulfur analysis.
-
Direct Preparation of Sulfide Semiconductor Nanoparticles from the Corresponding Bulk Powders in an Ionic Liquid
The concentration of nanoparticles in the ionic liquid medium was determined by X-ray fluorescence using an Oxford Instruments LabX3500S total sulfur analyzer.
-
http://repository.up.ac.za/bitstream/handle/2263/27726/dissertation.pdf?sequence=1
The Leco instrument analysed total sulphur by burning the sample at 13500 C.
-
Air Quality and Emissions from Livestock and Poultry Production/Waste Management Systems
This instrument measures total reduced sulfur (TRS) compounds, including alkyl sulfides, disulfides, mercaptans, and cyclic sulfur compounds.
-
A Two-Year Study of the Effectiveness of Geotextile Covers to Reduce Odor and Gas Emissions from Manure Storages
This instrument measures total reduced sulfur (TRS) compounds, including alkyl sulfides, disulfides, mercaptans, and cyclic sulfur compounds.
Indicates content that may require registration and/or purchase.