Supplier: CANNON Instrument Company
Description: The RX-620SA determines total sulfur in petroleum products using energy-dispersive X-ray fluorescence (EDXRF). Testing is quick, non-destructive, economical and accurate. The instrument comes with a 12 position autosampler for unattended processing.
- Property Analyzed: Sulfur Content
- Tested Fuel: Fuel Oil
-
Supplier: Analytical Systems Int’l. Keco
Description: associated parts and supplies, Analytical Systems International (ASI) has met these requirements with their proven microprocessor based analyzer. The Model 1700 System measures total sulfur by hydrogenation similar to that as described in ASTM Method D3031, D4084-82, D4468-85 and
- Application: Continuous Emissions Monitoring
- Display: Digital
- Electrical Outputs: Analog Current, Switch
- Features: Audible or Visual Alarms, Controller
-
Supplier: Analytical Systems Int’l. Keco
Description: /LED optics & rate-of-reaction digital electronics to provide an accurate and reproducible total sulfur analysis with PPB or PPM sensitivity up to 100%. The LCD display provides the current reading, any alarm condition, procedure prompts (such as calibration procedure), and failure
- Application: Continuous Emissions Monitoring
- Display: Digital
- Electrical Outputs: Analog Current, Switch
- Features: Audible or Visual Alarms, Controller
-
-
Description: ISO 19579:2006 specifies an alternative method of determining the total sulfur content of hard coal, brown coal, and lignite by high-temperature combustion and infrared absorption using commercially available instruments. This method has been shown to be applicable to coal
-
Supplier: Analytical Technology, Inc.
Description: The ATI Model A15/79 Total Chlorine Monitor uses the standard iodometric method for the determination of total chlorine in highly contaminated samples. A unique sensing technique is used to determine total chlorine concentration, while minimizing system maintenance requirements.
-
Supplier: Analytical Systems Int’l. Keco
Description: associated parts and supplies, Analytical Systems International (ASI) has met these requirements with their proven microprocessor based analyzer. The Model 1700 System measures total sulfur by hydrogenation similar to that as described in ASTM Method D3031, D4084-82, D4468-85 and
- Application: Continuous Emissions Monitoring
- Display: Digital
- Electrical Outputs: Analog Current, Switch
- Features: Audible or Visual Alarms, Controller
-
Supplier: HORIBA Instruments, Inc.
Description: The MEXA 1170 SX is a new instrument used to measure sulfur for after treatment and transient lubricant oil consumption. The analyzer uses ultraviolet fluorescence (UVF) for detection and it can be operated in a total sulfur mode, analyzing sulfur oxides, hydrogen
- Display Type: Digital Display
- Measures Conductivity / Dissolved Solids: Yes
- Mounting / Environment: In-Situ / Field
- User Controls: Digital Front Panel
-
Supplier: CANNON Instrument Company
Description: The RX-630SA determines total sulfur in petroleum products using energy-dispersive X-ray fluorescence (EDXRF). Testing is quick, non-destructive, economical and accurate. The instrument comes with a 12 position autosampler for unattended processing.
-
Supplier: ASTM International
Description: 1.1 This test method covers the individual determination of total fluorine, chlorine and sulfur in aromatic hydrocarbons and their mixtures. Samples containing 0.10 to 10 mg/kg of each element can be analyzed. 1.2 This method can be applied to sample concentrations outside the range
-
Supplier: ASTM International
Description: 1.1 This test method covers the individual determination of total fluorine, chlorine and sulfur in aromatic hydrocarbons and their mixtures. Samples containing 0.10 to 10 mg/kg of each element can be analyzed. 1.2 This method can be applied to sample concentrations outside the range
-
Supplier: ASTM International
Description: 1.1 This test method covers the individual determination of total fluorine, chlorine, and sulfur in aromatic hydrocarbons and their mixtures. Samples containing 0.10?mg/kg to 10?mg/kg of each element can be analyzed. 1.2 This method can be applied to sample concentrations outside the
-
Supplier: CSA Group
Description: ISO 19579:2006 specifies an alternative method of determining the total sulfur content of hard coal, brown coal, and lignite by high-temperature combustion and infrared absorption using commercially available instruments. This method has been shown to be applicable to coal
-
Supplier: ASTM International
Description: and the highest level sample in the round robin, 4.6 weight % total sulfur. Note 1: Instrumentation covered by this test method can vary in sensitivity. The applicability of the test method at sulfur concentrations below 3 mg/kg may be determined on an individual basis for WDXRF
-
Supplier: SICK
Description: Overview The S700 modular system is very easy to configure to provide a tailor-made application. An S700 housing can be equipped with up to 3 analyzer modules for compact and cost-effective system solutions. A total of 5 different analyzer modules are available for analyzing more than
- Application: Continuous Emissions Monitoring, Process Gas
- Display: Digital
- Electrical Outputs: Analog Current
- Features: Interchangeable Probes, Hazardous Environments, Self Calibration
-
Supplier: InspectorTools
Description: temperature, relative humidity, and up to 5 additional plug-and-play ‘smart’ sensors, including carbon dioxide (CO2), carbon monoxide (CO), oxygen (O2), formaldehyde (HCHO), total volatile organic compounds (TVOCs), nitrogen dioxide (NO2), sulfur dioxide (SO2), ammonia (NH3), hydrogen
-
Supplier: InspectorTools
Description: temperature, relative humidity, and up to 5 additional plug-and-play ‘smart’ sensors, including carbon dioxide (CO2), carbon monoxide (CO), oxygen (O2), formaldehyde (HCHO), total volatile organic compounds (TVOCs), nitrogen dioxide (NO2), sulfur dioxide (SO2), ammonia (NH3), hydrogen
-
Supplier: InspectorTools
Description: temperature, relative humidity, and up to 5 additional plug-and-play ‘smart’ sensors, including carbon dioxide (CO2), carbon monoxide (CO), oxygen (O2), formaldehyde (HCHO), total volatile organic compounds (TVOCs), nitrogen dioxide (NO2), sulfur dioxide (SO2), ammonia (NH3), hydrogen
-
Supplier: Emerson Automation Solutions – Rosemount
Description: -component gas analyzer provides instant online analysis of the sample with unsurpassed measurement accuracy, performance and repeatability. Discover why QCL’s patented technology is changing the industry. Easy Startup and Commissioning with Lowest Total Cost of
- Application: Continuous Emissions Monitoring, Process Gas
- Electrical Outputs: Analog Current
- Features: Hazardous Environments, Self Calibration
- Instrument Type: Analyzer
-
Supplier: C.I. Analytics, Inc.
Description: Process Analyzer The 9750 comes with a UVF detector to measure Total Sulfur. Although we believe the tape based method provides a more reliable and consistent method of analysis for Total Sulfur, we provide an alternative to tape-based analysis to meet the requirements of
-
Supplier: C.I. Analytics, Inc.
Description: the 9710 features, the 9730 has the capability to allow TOTAL analysis, whether it is Total sulfur or Total Chlorides. Let’s consider the following as an example: For Total Sulfur Analysis the analyzer measures the presence of sulfur in gas process
-
Supplier: C.I. Analytics, Inc.
Description: . All electronics are sealed in an explosion proof container and it meets ASTM D-4045-81/D-4468-81/ D4084-82/D6313-99 for Sulfur analysis. It can also be made to analyze Total Chlorides; the world’s first dependable, continuous, on-line analyzer for detecting total organic
-
Supplier: SAE International
Description: This SAE Aerospace Recommended Practice (ARP) describes the continuous sampling and analysis of gaseous emissions from aircraft gas turbine engines. The measured gas species include carbon monoxide (CO), carbon dioxide (CO 2 ), nitric oxide (NO), nitrogen dioxide (NO 2 ), total hydrocarbons
Find Suppliers by Category Top
Featured Products Top
-
) for the same data total with more ECC bits. Two smaller independent channels improve memory access efficiency, leading to greater speeds with higher efficiency. New Yorker Electronics supplies the Innodisk DDR5 up to 32GB and 4800MT/s. Less (read more)
Browse Memory Modules Datasheets for New Yorker Electronics Co., Inc. -
Operate with a battery or external power supply Extremely rugged Reliable high resolution analysis even for low levels of carbon, phosphorus, sulfur, boron, arsenic and tin in low alloy and stainless steels Unlimited number of channels for total spectrum analysis (read more)
Browse Atomic Emission and Optical Emission Spectrometers Datasheets for Hitachi High-Tech America -
flanges and flanged fittings standards. MTA Pump specifications Product Category: Centrifugal Pump Total Head (read more)
Browse Magnetic Drive Pumps Datasheets for Texel-Seikow USA, Inc. -
– Secondary operations can transform a simple tube into the part needed. CNC Machining, cutting, welding, bending and precision grinding are among the operations to tailor your tube to the part you need. Total Cost – When (read more)
Browse Metal Tubes Datasheets for Eagle Stainless Tube & Fabrication, Inc. -
– Secondary operations can transform a simple tube into the part needed. CNC Machining, cutting, welding, bending and precision grinding are among the operations to tailor your tube to the part you need. Total Cost (read more)
Browse Stainless Steel Alloys Datasheets for Eagle Stainless Tube & Fabrication, Inc. -
Valves, in ASME Class 150 and 300, provide exceptional performance while reducing the total cost of ownership. DeZURIK High Performance Butterfly Valves have been successfully applied in extreme services, including high-temperature services, throttling steam (read more)
Browse Butterfly Valves Datasheets for DeZURIK, Inc. -
of it: The 90,000 ships worldwide burn a total of 370 million tons of fuel per year – and produce 20 million tons of sulfur oxide. Therefore, electrification is necessary to remove these heavy pollutants from the shipping industry. Three main streams of ship electrification (read more)
Browse DC Power Supplies Datasheets for EA Elektro-Automatik Inc.
Conduct Research Top
-
Total Sulfur Analysis in Natural Gas with the 700XA Gas Chromatograph
A fundamental requirement for gas safety and contract sale of natural gas is to measure the amount of H2S and Total Sulfur. The level of these contaminants and sulfur-based odorants is strictly controlled to avoid equipment damage and risk to site personnel in transmission and distribution
-
The State of the Art In Gas Cleaning for the Fertilizer Industry
The fertilizer industry has earned recognition for having contributed directly to increase world grain yields in the past century. Based on the conservative estimate of the world population growth, total fertilizer use in the future is expected to grow more than 200 million tons from the current
More Information Top
-
Organic sulphur fixation in freshwater lake sediments and the implication for US ratios
Zimmermann for their help with sample collection and analyses and G. Schroder for the use of his total sulphur instrument .
-
Data summary report for M.W. Kellog zinc titanite test series: ZTSC-01, ZTSC-02, ZTSC-03, ZTSC-04, ZTSC-05, ZTSC-06, ZTSC-07, ZTSC-08, ZTMC-01, ZTMC-02, ZTMC-0...
Total sulfur analyses were performed by EG&G utilizing a LECO Model SC-32 Total Sulfur Analyzer instrument .
-
Bacterial ecology of a young equatorial hydroelectric reservoir (Petit Saut, French Guiana)
H2S concentrations were determ- ined by oxidation at 800 ◦C with a total reduced sulphur instrument (Environment S.A., AF41M).
-
Atmospheric Sulfur Analysis Using Rateometric Colorimetry
KEY WORDS: sulfur, hydrogen sulfide, total sulfur , instruments , monitors, colorime- try, air pollution, measurement, atmospheric sulfation .
-
Data summary report for M.W. Kellog zinc ferrite test ZFMC-01 CRADA 92-008. Final report
Total sulfur analyses were performed by EG&G uti:Lizing a LECO Model SC-32 Total Sulfur Analyzer instrument .
-
Phosphorus biogeochemistry in sediments of high altitude lakes, Kumaun Himalayas, India
The USGS standard SCO-1 was used to calibrate the instrument for total sulfur analysis.
-
Direct Preparation of Sulfide Semiconductor Nanoparticles from the Corresponding Bulk Powders in an Ionic Liquid
The concentration of nanoparticles in the ionic liquid medium was determined by X-ray fluorescence using an Oxford Instruments LabX3500S total sulfur analyzer.
-
http://repository.up.ac.za/bitstream/handle/2263/27726/dissertation.pdf?sequence=1
The Leco instrument analysed total sulphur by burning the sample at 13500 C.
-
Air Quality and Emissions from Livestock and Poultry Production/Waste Management Systems
This instrument measures total reduced sulfur (TRS) compounds, including alkyl sulfides, disulfides, mercaptans, and cyclic sulfur compounds.
-
A Two-Year Study of the Effectiveness of Geotextile Covers to Reduce Odor and Gas Emissions from Manure Storages
This instrument measures total reduced sulfur (TRS) compounds, including alkyl sulfides, disulfides, mercaptans, and cyclic sulfur compounds.