Dry Gas Seals Handbook

Tabulation of Alarms and Shutdowns

A tabulation of suggested alarms and shutdowns, based on the gas seal system design recommendations contained in this chapter, is provided in table 5-1.

Table 5-1: Tabulation of alarms and shutdowns

Alarm Condition

Shutdown Condition

Permissive to Start

Seal gas filter differential pressure

High

NA

NA

Seal gas supply pressure or flow

Low

Low

Required

Primary vent pressure or flow

High

High

NA

Separation gas filter differential pressure

High

NA

NA

Separation gas supply differential pressure

Low

Low (delayed)

Required