Supplier: Shimadzu Scientific Instruments, Inc.
Description: The AA-7000 series' 3-D optical system is capable of producing maximum performance for both flame (Pb 0.015 ppm) and furnace detection (Pb 0.05 ppb). This is achieved through optimal adjustment of the light beam and digital filter, and by using optical components that restrict light loss. And, with
- Application Software Included: Yes
- Background Correction: Yes
- Computer Interface: Yes
- Computer Interface Options: Serial Interface
-
Supplier: Shimadzu Scientific Instruments, Inc.
Description: Shimadzu's double beam AA-6200 atomic absorption spectrophotometer combines high performance with affordability. The double beam system provides the superior baseline stability expected from high-performance optical systems at an affordable price. Windows®-based software Wizard
- Alarms: Yes
- Application Software Included: Yes
- Background Correction: Yes
- Computer Interface: Yes
-
Supplier: Aurora Instruments
Description: newest addition to their line of atomic absorption spectrometers - the TRACE AI800. The TRACE AI800 Atomic Absorption Spectrometer is specifically designed with low-budget users in mind but without sacrificing performance quality for atomic
-
-
Supplier: Aurora Instruments
Description: Spectrometer brochure or contact us directly to discuss your specific application. Thank you for considering AURORA to solve your atomic absorption spectroscopy requirements. Current industry demands require that elemental analyses embody higher precision, higher sensitivity,
-
Supplier: Aurora Instruments
Description: Aurora has built a reputation as an industry leader manufacturing atomic absorption spectrometers and atomic fluorescence spectrometers. Thanks to its many customizable options, the TRACE AI1200 is also one of the most versatile atomic absorption
-
Supplier: Aurora Instruments
Description: Atomic absorption spectroscopy (AAS) is a common technique used in many analytical chemistry protocols, as well as applications requiring a high degree of precision and accuracy, such as food & drug safety, clinical diagnostics, and environmental sampling. Atomic
-
Supplier: Hitachi High Technologies America, Inc.
Description: analyzed by a mass spectrometer enabling high-speed measurement. The accurate and smooth performance of the auto-sampler (standard equipment) allows continuous automatic analysis of up to 50 samples. During the analysis, operators are free to engage in other tasks, resulting in a streamlined
-
Supplier: Hitachi High Technologies America, Inc.
Description: ZA3000 series developed to meet user’s needs is a new elemental analysis instrument which employs the technology unachievable by other atomic absorption spectrophotometers so as to enhance the functionality and reliability while preserving the basic performance of the polarized Zeeman
-
Supplier: LECO Corporation
Description: range from 120 to 800 nm and may be configured with up to 58 channels. Separation of sputtering and excitation Linear calibration curves with wide dynamic range Lowered self-absorption and material re-deposition Excitation of almost exclusively atom lines
- Application Software Included: Yes
- Computer Interface: Yes
- Detector: Solid State (CCD)
- Display Options: None
-
Supplier: Accuris
Description: German Language - ATOMIC ABSORPTION SPECTROMETRY; STRUCTURE OF ATOMIC ABSORPTION SPECTROMETERS
-
Supplier: Hitachi High Technologies America, Inc.
Description: Energy scanning range:3.2~6.2eV Applications OELD, OTFT , Organic film solar cell Photocatalyst Carbon nano tube , Fullerene Carbon thin film , Diamond thin film Cosmetics , Nostrum , Pharmaceutical products OPC Electrode , Lead frame , Silicon wafer , Compound semiconductor wafer Metals for
-
Supplier: Accuris
Description: ATOMIC ABSORPTION SPECTROMETERS FOR MEASURING METAL POLLUTANTS IN WATER
-
Description: (injection of the acidified sample into an electrically heated graphite tube of an electrothermal atomization atomic absorption spectrometer and measurement of the absorbance at a wavelength of 228,8 nm).
-
Description: The principle of the method specified is dissolving a test portion in hydrochloric and nitric acids and dilution of the solution to a known volume, introducing a known volume of the solution into an electrothermal atomizer of an atomic absorption spectrometer, measuring the
-
Description: and perchloric acids, dissolving of the residue in hydrochloric acid, measuring the absorption using a flame atomic absorption spectrometer at 248,3 nm. Measures the concentration of iron, expressed as its oxide Fe2O3. Applies to the analysis of extract solutions obtained
-
Description: The principle of the method specified is adding a caesium chloride solution to the sample as an ionization suppressant, aspirating the sample directly into the air/acetylene flame of an atomic absorption spectrometer and measuring the absorbance at a wavelength of 589,0 nm.
-
Description: Applies to electrically powered laboratory atomic spectrometers with thermal atomization, including atomic absorption spectrometers, emission flame photometers, atomic fluorescence spectrophotometers, inductively coupled plasma spectrometers,
-
Supplier: CSA Group
Description: (injection of the acidified sample into an electrically heated graphite tube of an electrothermal atomization atomic absorption spectrometer and measurement of the absorbance at a wavelength of 228,8 nm).
-
Supplier: CSA Group
Description: The principle of the method specified is dissolving a test portion in hydrochloric and nitric acids and dilution of the solution to a known volume, introducing a known volume of the solution into an electrothermal atomizer of an atomic absorption spectrometer, measuring the
-
Supplier: ASTM International
Description: 1.1 This practice covers the optimization of electrothermal atomic absorption spectrometers and the checking of spectrometer performance criteria. 1.2 The values stated in SI units are to be regarded as the standard. 1.3 This standard does not purport to address all of
-
Supplier: ASTM International
Description: 1.1 This practice covers the optimization of electrothermal atomic absorption spectrometers and the checking of spectrometer performance criteria. 1.2 The values stated in SI units are to be regarded as the standard. This standard does not purport to address all of the
-
Supplier: ASTM International
Description: 1.1 This practice covers the optimization of electrothermal atomic absorption spectrometers and the checking of spectrometer performance criteria. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the
-
Supplier: ASTM International
Description: 1.1 This practice covers the optimization of flame atomic absorption spectrometers and the checking of spectrometer performance criteria. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of
-
Supplier: CSA Group
Description: and perchloric acids, dissolving of the residue in hydrochloric acid, measuring the absorption using a flame atomic absorption spectrometer at 248,3 nm. Measures the concentration of iron, expressed as its oxide Fe2O3. Applies to the analysis of extract solutions obtained
-
Supplier: CSA Group
Description: Silicon content can be determined in the range of 0,2 % (m/m) to 1 % (m/m). The principle is dissolution of a test portion in acid, aspiration of the test solution into a nitrous oxide-acetylene flame of an atomic absorption spectrometer, measurement of the absorbance of the
-
Supplier: Element Materials Technology
Description: X-ray Spectrometers Portable X-Ray Fluorescent Analyzer Optical Emission Spectroscopy (OES) Portable Optical Emission Spectroscopy (OES) Atomic Absorption (AA) Analyzers Inductively Coupled Plasma (ICP) Combustion/IR Analyzers Gas
- Industry: Aerospace / Aviation, Automotive, Chemical / Material Processing, Food / Beverage, Health Care / Medical, Legal / Forensics, Marine, Military, Nuclear / Utility, Packaging, Pharmaceutical / Biotech, Piping / Pressure Vessel, Semiconductors / Electronics, Structural / Construction, Specialty / Other
- Laboratory Services Offered: Chemical Testing Services, Deformulation / Reverse Engineering, Environmental Exposure, Failure Analysis, Field Sampling, Geotechnical Services, Materials Testing Services, Monitoring Programs (Audits / Surveillance), Purity / Quality (Air, Water, Material), Stack Emissions / Opacity Testing,
- Materials: Adhesives / Sealants, Air, Ceramics / Glass, Chemicals, Coatings, Composites, Concrete / Mortar, Gases, Heavy Metals (Lead, Chromium, etc.), Inorganics, Metals, Nanomaterials, Paper, Petroleum Fluids (Oil, Fuel, Distillates), Plastic / Rubber, Polymers / Organics, Powders, Sediment, Soil, Toxins /
- Regional Preference: North America, United States Only, Northeast US Only, Southern US Only, Southwest US Only, Northwest US Only, Midwest US Only, Canada Only, Europe Only
-
Supplier: Element Materials Technology
Description: : Sequential X-ray Spectrometers Portable X-Ray Fluorescent Analyzer Optical Emission Spectroscopy (OES) Portable Optical Emission Spectroscopy (OES) Atomic Absorption (AA) Analyzers Inductively Coupled Plasma (ICP) Combustion/IR Analyzers
- Industry Applications: Aerospace / Aviation, Food / Beverage, Automotive, Chemical / Material Processing, Health Care / Medical, Legal / Forensics, Marine, Military, Nuclear / Utility, Pharmaceutical / Biotech, Packaging, Piping / Pressure Vessel, Semiconductors / Electronics, Structural / Construction, Specialty / Other
- Materials: Adhesives / Sealants, Air, Ceramics / Glass, Chemicals, Coatings, Composites, Concrete / Mortar, Inorganics, Metals, Paper, Petroleum Fluids (Oil, Fuel, Distillates), Plastic / Rubber, Polymers / Organics, Powders, Soil, Textiles, Thin Films / Plating, Volatiles (VOCs) / Solvents, Toxins /
- Regional Preference: North America, United States Only, Northeast US Only, Southern US Only, Southwest US Only, Northwest US Only, Midwest US Only, Canada Only, Europe Only
- Services Offered: Deformulation / Reverse Engineering, Environmental Exposure Testing, Field Sampling, Geotechnical Services, Materials Testing Services, Monitoring Programs (Audits / Surveillance), Quality / Purity (Contamination), Standards Testing / Certification, Sunlight Exposure / Solar Simulation, Other
-
Supplier: Excelitas Noblelight America LLC
Description: Fisher atomic absorption spectrometers. Lamps for use with Smith-Hieftje background correction can also be offered: 70 single-element lamps More than 120 multi-element lamps with up to seven combined elements Customary diameters 1 ½" and 2" Low-current and high
- Lamp Type: Other
Find Suppliers by Category Top
More Information Top
-
New developments in atomic absorption spectrometry
The main function of atomic absorption spectrometers is quantitative determination of the con- centration of an analyte element (the analyte) in a test sample.
-
ZASMHBA0001730
Therefore, the analytical response of atomic absorption spectrometers is element-selective and not as sensitive to atomizer temperature variations as that of atomic emission spectrometers.
-
Food Analysis
When atomic absorp- tion spectrometers became widely available in the 1960s, the development of atomic absorption spec- troscopy (AAS) methods for accurately measuring trace amounts of mineral elements in biological sam- ples paved the way for unprecedented advances in fields as diverse …