Supplier: Panametrics
Description: cell O2 sensor technology User selectable ranges for ppm and percent oxygen User-friendly and intuitive user interface with diagnostics Microprocessor-based , all-digital technology for reliable operation Low maintenance, economical and compact Sensor failure output error
- Display: Digital
- Electrical Outputs: Analog Current
- Features: Hazardous Environments, Intrinsically Safe
- Measurement Type: %Volume, Trace, Leakage
-
Supplier: ABB Measurement & Analytics
Description: Featuring a separate sensor section and transmitter, the Navigator 500 Dissolved Oxygen gives users the option of adding up to four wet-sections to one transmitter, enabling measurement of samples from different measuring points. This not only offers an economic and compact solution,
- Accuracy: -1.00E-3 to 1.00E-3 ppm
- Built-in or Self-calibration: Yes
- Control Relays: 4 to 6
- Dissolved Oxygen Sensor Technology: Galvanic
-
Supplier: Campbell Scientific, Inc.
Description: The CS511 is a rugged, low-maintenance sensor that is manufactured by Sensorex. It consists of a self-polarizing galvanic cell that generates a millivolt signal proportional to the amount of oxygen present in the measured medium (typically water). Oxygen diffuses
- Accuracy: 2 % FS
- Built-in Temperature Sensor: Yes
- Cell Type: Galvanic
- Disposable Membrane Cap: Yes
-
-
Supplier: Analytical Technology, Inc.
Description: ATIs Model Q45D Dissolved Oxygen monitor provides reliable oxygen measurement and reduced maintenance costs. The galvanic dissolved oxygen sensor uses a rugged 5 mil Teflon membrane to resist mechanical abrasions and tears. The membrane serves as a barrier to allow
-
Supplier: Process Sensing Technologies USA
Description: The Minox i Galvanic Fuel Cell Oxygen Transmitter is a highly reliable and cost-effective two-wire, loop-powered transmitter with a linearized 4 to 20 mA output. The standard offering has a detection measurement range of 0-25% oxygen. This compact transmitter utilises
- Features: Self Calibration
-
Description: updated where appropriate; b) the description of the principle of the galvanic cell has been expanded and clarified; c) new definitions and illustrations have been added for different measurement methods for oxygen using solid electrolytes for galvanic cells; d)
-
Supplier: BlueSens Gas Sensor GmbH
Description: automatically compensates any fluctuations of pressure and humidity in the system. The readings are therefore extremely accurate even under fluctuating measuring conditions. The BlueInOne Cell gas analyzer is fitted with an IR CO2 sensor, as well as a new electrochemical oxygen
- Specific Gas Types: Carbon Dioxide (CO2)
-
Supplier: Process Sensing Technologies USA
Description: fuel cell oxygen sensor that are extensively used to measure concentrations from 0% to 100% O2 in gas streams. Features: 0 to 100% O2 measurement range 0 to 25ppm CO Long sensor life up to 60 months (AII-3000) Battery life up to 13,000 hours of
- Display: Digital
- Features: Self Calibration
- Instrument Type: Monitor
- Measurement Type: %Volume, Trace
Find Suppliers by Category Top
Featured Products Top
-
Hamilton Company introduces the Incyte capacitance sensor for viable cell density monitoring in bioprocessing, along with (read more)
Browse Dissolved Oxygen Sensors Datasheets for Hamilton Company -
Pressure sensor with high-quality ceramic measuring cell Robust, flexible, hygienic (read more)
Browse Pressure Sensors Datasheets for ifm electronic gmbh -
the danger of electrical shock and the flammability of the fuel." Isabellenhütte is enhancing fuel cell designers' ability to improve electrical isolation within these fuel cells with a sensor that can monitor ground faults and be used to control contactors upon detection of a ground (read more)
Browse Current Sensors Datasheets for Isabellenhutte USA -
Increasingly, vehicles are being built on electric motors instead of internal combustion engines and smart components are increasingly being added into vehicles. The switch to e-mobility presents the automotive industry with major challenges, as an electric vehicle requires additional sensors (read more)
Browse Temperature Sensors Datasheets for Innovative Sensor Technology IST USA Division -
-TEDS service. The service uses a AD9 (9 PIN “D” Series) Connector attached to the load cell or torque sensor cable. The connector has a TEDS EEPROM chip that works with the DPM-3 meter. With this update, legacy and non-TEDS sensors will be capable of plug and play with IEEE 1451.4 compliant (read more)
Browse Torque Sensors Datasheets for Transducer Techniques, LLC -
. Knick Interface High Voltage Transducers From monitoring DC current, integral in controlling PEM electrolysis for H2 production, to evaluating high voltage DC levels in hydrogen fuel cell stacks, Knick's products have exhibited proven success. The common denominator (read more)
Browse Electrical Voltage Sensors Datasheets for Knick Interface LLC -
Dissolved carbon dioxide (DCO?) is a critical process parameter (CPP) in biopharma production processes according to PAT guidelines. By influencing other parameters such as extracellular and intracellular pH, it has an effect on different metabolic pathways which are involved in cell (read more)
Browse Dissolved Oxygen Sensors Datasheets for Hamilton Company -
Compact, shunt-based current sensing for automotive applications, including UPS and energy storage systems, battery applications, and fuel cells. An affordable solution for 12-48V (read more)
Browse Current Sensors Datasheets for Isabellenhutte USA -
In the quest to find cleaner, more sustainable sources of energy, hydrogen fuel cell technology is a promising area. Hydrogen is present in water and nearly all living things. As a renewable source of energy, it has enormous potential to generate power, electricity, and heat. (read more)
Browse Temperature Sensors Datasheets for Backer Hotwatt Inc. -
VEGABAR, VEGAWELL: Hydrostatic pressure measurement The measuring cell of the pressure transducer detects minute changes in hydrostatic pressure, which increases or decreases depending on the filling level (read more)
Browse Pressure Sensors Datasheets for VEGA Americas, Inc.
More Information Top
-
Polymeric Sensors and Actuators
Solid electrolyte oxygen sensors and galvanic cell oxygen sensors are widely used sensors for monitoring gaseous oxygen.
-
A fibre-optic oxygen sensor for monitoring human breathing
… 2010 434863 Mohanty L and Kuang K S C 2010 A breathing rate sensor with plastic optical fiber Appl. Phys. Lett. 97 073703 Oqino H and Asakura K 1995 Development of a highly sensitive galvanic cell oxygen sensor Talanta 42 305–10 Overdyk …
-
The development of PIV–PSP hybrid system using pressure sensitive particles
The oxygen concentration was monitored using a galvanic cell oxygen sensor before introduction to the test section, and the gas was exhausted at the same rate.
-
Techniques for measuring the partial pressures of gases in the blood. II. In vivo measurements
Figure 6 A schematic diagram showing the tip of a galvanic cell oxygen sensor .
-
Development of Small-Scale Hypobaric Plant Chambers
Parameter Sensor Description Accuracy Air temperature Type-T thermocouples ± 0.5°C Pressure Integrated circuit pressure sensor ± 0.53 kPa Relative humidity Integrated circuit RH sensor ± 2.1% Oxygen Galvanic cell sensor ± 1.0% Carbon dioxide Ultrasonic sensor ± …
-
Anesthetic Potency of Desflurane in the Horse: Determination of the Minimum Alveolar Concentration
In- spired O2 concentration (FiO,) was measured by means of an oxygen sensor ( Galvanic Cell R15,5250Respiratory Gas Monitor, Ohmeda-BOC, Spain).
-
Fluorescence oxygen sensor using photo quenching with oxygen molecule
The response time of the fiber-optic oxygen sensor is faster than that of the conventional sensor such as gal- vanic cell type oxygen sensor .
-
Associations of cardiorespiratory fitness, physical activity, and obesity with metabolic syndrome in Hong Kong Chinese midlife women
It uses a turbine flowmeter for measuring ventilation and a gal- vanic fuel cell oxygen sensor for analyzing oxygen in ex- pired gases, and a new sampling technology has been adopted through the use of a small sample of the expired volume …
-
Toward quantifying the usage costs of human immunity: Altered metabolic rates and hormone levels during acute immune activation in men
A reclined, awake par- ticipant breathed normally through a facemask (over the nose and mouth) equipped with a turbine flowmeter and galvanic fuel cell oxygen sensor for 12 min.
-
Environmentally Friendly Technologies for Agricultural Produce Quality
In most cases, oxygen sensing is by paramagnetic or galvanic (fuel cell ) oxygen sensors , and CO2 determination is by infrared gas analysis.