Wire Wound Resistive Temperature Devices (RTD) Elements
from Pyromation
Resistance temperature detectors (RTDs), also known as resistance thermometers, accurately sense process temperatures with an excellent degree of repeatability and interchangeability of elements. The RTD is composed of certain metallic elements whose change in resistance is a function of... [See More]
- Technology: Wire Wound (Platinum)
- Accuracy: 0.1000 to 0.1200
- Operating Temperature: ? to 400
- Coefficient of Resistance: 0.003850
from Conax Technologies
This termination features aluminum oxide powder insulation surrounding the element and insulated leadwires, all capped with potting compound to prevent moisture penetration. * The insulation protects the integral leadwires under mildly adverse atmospheric conditions. * Unit is to be used straight. [See More]
- Technology: Wire Wound
- Sensor Type: Standard
- Operating Temperature: 300
- Length: 24
from RS Components, Ltd.
100 ohm wire wound detectors 1/10 Din [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: 100
- Operating Temperature: -328 to 1112
- Length: 0.3150
from TE Connectivity
Configuration Features. Electrical Connection : Open End. Dimensions. Body Diameter : 1.8 MM [.07 INCH ]. Body Length : 5 MM [.197 INCH ]. Wire Diameter : .2 MM [.007 INCH... [See More]
- Technology: Wire Wound (Platinum)
- Accuracy: 0.1500
- Operating Temperature: 482
from Innovative Sensor Technology IST USA Division
With the 3770 ppm/K characteristics curve, the IST AG 1000 °C Series is specially developed for the automotive industry. The 1000 °C Series, offers an excellent long-term stability and fast response time with low self-heating within a temperature range of -70 °C to +1000 °C. ... [See More]
- Technology: Wire Wound (Platinum)
- Length: 0.1516
- Operating Temperature: -94 to 1832
- Width / Diameter.: 0.0748
from Pyromation
Thermocouple and RTD spring-Loaded Replacement elements are designed for spring-loaded thermowell assemblies. The replacement elements can be ordered by selecting the sensor type below and inserting the "X" length in table 2-0. The RTD assemblies are supplied with a 316 stainless steel sheath and... [See More]
- Technology: Wire Wound (Platinum)
- Accuracy: 0.0600 to 0.1200
- Operating Temperature: -328 to 1112
- Coefficient of Resistance: 0.003850
from TE Connectivity
Configuration Features. Electrical Connection : Open End. Dimensions. Body Diameter : 1.8 MM [.07 INCH ]. Body Length : 5 MM [.197 INCH ]. Wire Diameter : .2 MM [.007 INCH... [See More]
- Technology: Wire Wound (Platinum)
- Accuracy: 0.1000
- Operating Temperature: 302
from Innovative Sensor Technology IST USA Division
The IST AG 300 °C Series offers an excellent long-term stability and simple linearization within a temperature range of -60 °C to +300 °C. The 300 °C Series is vibration and temperature shock resistant with simple interchangeability and small dimensions. Additionally, the 300... [See More]
- Technology: Wire Wound (Nickel)
- Nominal Resistance: 100 to 1000
- Operating Temperature: -76 to 572
- Sensor Type: Standard; Precision
from TE Connectivity
Configuration Features. Connector Type : Open Ends. Dimensions. Diameter (Body) : 1.8 MM [.07 INCH ]. Length (Body) : 5 MM [.197 INCH ]. Wire Diameter : .2 MM [.007 INCH... [See More]
- Technology: Wire Wound (Platinum)
- Accuracy: 0.3000
- Operating Temperature: -321 to 752
- Length: 0.1970
from Innovative Sensor Technology IST USA Division
The IST AG 600 °C Series offers excellent long-term stability and fast response time with low self-heating within a temperature range of -200 °C to +600 °C. The 600 °C Series is a standard solution for various temperature applications. The RTD temperature sensor is suitable... [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: 100 to 1000
- Operating Temperature: -328 to 1112
- Sensor Type: Standard; Precision
from TE Connectivity
Configuration Features. Electrical Connection : Open End. Dimensions. Body Diameter : 1.3 MM [.051 INCH ]. Body Length : 10 MM [.39 INCH ]. Wire Diameter : .2 MM [.007 INCH... [See More]
- Technology: Wire Wound (Platinum)
- Accuracy: 0.3000
- Operating Temperature: 752
from Innovative Sensor Technology IST USA Division
The IST AG 150 °C Series offers excellent long-term stability and fast response time with low self-heating within a temperature range of -50 °C to +150 °C. The IST AG 150 °C series is developed with an insulated enameled Cu-wire, which enables easy integrating into... [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: 100 to 1000
- Operating Temperature: -58 to 302
- Sensor Type: Standard; Precision
from TE Connectivity
Configuration Features. Electrical Connection : Open End. Dimensions. Body Diameter : 1.8 MM [.07 INCH ]. Body Length : 10 MM [.39 INCH ]. Wire Diameter : .2 MM [.007 INCH... [See More]
- Technology: Wire Wound (Platinum)
- Accuracy: 0.3000
- Operating Temperature: 752
from Innovative Sensor Technology IST USA Division
The IST AG 200 °C Series offers an excellent long-term stability and fast response time with low self-heating within a temperature range of -50 °C to +200 °C. The 200 °C Series is offered in various standard lengths with Cu/Ag- single or stranded wire with PTFE -insulation. [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: 100 to 1000
- Operating Temperature: -58 to 392
- Sensor Type: Standard; Precision
from TE Connectivity
Configuration Features. Connector Type : Open Ends. Dimensions. Diameter (Body) : 2.8 MM [.11 INCH ]. Length (Body) : 15 MM [.6 INCH ]. Wire Diameter : .25 MM [.009 INCH... [See More]
- Technology: Wire Wound (Platinum)
- Accuracy: 0.3000
- Operating Temperature: -321 to 752
- Length: 0.6000
from Innovative Sensor Technology IST USA Division
The IST AG 300 °C Series offers an excellent long-term stability and fast response time with low self-heating within a temperature range of -200 °C to +300 °C. The 300 °C series offers a stable performance at a low price and is available with Au-coated Ni-wire which makes it... [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: 100 to 1000
- Operating Temperature: -328 to 572
- Sensor Type: Standard; Precision
from TE Connectivity
Configuration Features. Connector Type : Open Ends. Dimensions. Diameter (Body) : 2.8 MM [.11 INCH ]. Length (Body) : 15 MM [.6 INCH ]. Wire Diameter : .25 MM [.009 INCH... [See More]
- Technology: Wire Wound (Platinum)
- Accuracy: 0.1500
- Operating Temperature: -148 to 482
- Length: 0.6000
from Innovative Sensor Technology IST USA Division
The IST AG 400 °C Series offers an excellent long-term stability and fast response time with low self-heating within a temperature range of -200 °C to +400 °C. The 400 °C Series is vibration and temperature shock resistant and offers excellent solderability. The standard 400... [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: 100 to 1000
- Operating Temperature: -328 to 752
- Sensor Type: Standard; Precision
from TE Connectivity
Configuration Features. Electrical Connection : Open End. Dimensions. Body Diameter : 1.3 MM [.051 INCH ]. Body Length : 10 MM [.39 INCH ]. Wire Diameter : .2 MM [.007 INCH... [See More]
- Technology: Wire Wound (Platinum)
- Accuracy: 0.1500
- Operating Temperature: 482
from Innovative Sensor Technology IST USA Division
BondSens - Platinum Temperature Sensors are manufactured according to DIN EN 60751 and have an operating temperature range of -50 °C to +150 °C. The miniaturized RTD is designed for automatic placement in high volume applications in DIE packages where long-term stability, a good thermal... [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: 1000
- Operating Temperature: -58 to 302
- Sensor Type: Standard
from TE Connectivity
Configuration Features. Connector Type : Open Ends. Dimensions. Diameter (Body) : 1.3 MM [.051 INCH ]. Length (Body) : 10 MM [.39 INCH ]. Wire Diameter : .2 MM [.007 INCH... [See More]
- Technology: Wire Wound (Platinum)
- Accuracy: 0.1000
- Operating Temperature: 32 to 302
- Length: 0.3900
from Innovative Sensor Technology IST USA Division
The RealProbeTemp is a pre-assembled stainless steel probe for the simplified manufacturing of temperature probes. The RPT provides an outstanding response time. The construction of the RealProbeTemp allows a minimized immersion depth (e.g. liquids at a depth of 10 mm or in some cases slightly... [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: 100 to 1000
- Operating Temperature: -58 to 392
- Sensor Type: Standard; Precision
from TE Connectivity
Configuration Features. Connector Type : Open Ends. Dimensions. Diameter (Body) : 1.8 MM [.07 INCH ]. Length (Body) : 12 MM [.47 INCH ]. Wire Diameter : .2 MM [.007 INCH... [See More]
- Technology: Wire Wound (Platinum)
- Accuracy: 0.3000
- Operating Temperature: -321 to 752
- Length: 0.4700
from Innovative Sensor Technology IST USA Division
The IST AG PW RTD sensor has been developed as an alternative to the traditional wire-wound sensors. The PW sensor combines the advantages of high accuracy and precision of the wire-wound sensors with the advantages of thin-film sensors that offer robustness, small dimensions and very low hysteresis... [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: 100 to 1000
- Operating Temperature: -328 to 1112
- Sensor Type: Standard; Precision
from TE Connectivity
Configuration Features. Electrical Connection : Open End. Dimensions. Body Diameter : 2 MM [.078 INCH ]. Body Length : 10 MM [.39 INCH ]. Wire Diameter : .25 MM [.009 INCH... [See More]
- Technology: Wire Wound (Platinum)
- Accuracy: 0.3000
- Operating Temperature: 752
from Innovative Sensor Technology IST USA Division
The IST AG 750 °C Series offers measurements in high temperatures and excellent long-term stability, fast response time and low self-heating within a temperature range of -200 °C to +750 °C. Due to the special materials the sensors are very vibration resistant. Furthermore, the... [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: 100 to 1000
- Operating Temperature: -328 to 1382
- Sensor Type: Standard; Precision
from TE Connectivity
Configuration Features. Electrical Connection : Open End. Dimensions. Body Diameter : 2 MM [.078 INCH ]. Body Length : 10 MM [.39 INCH ]. Wire Diameter : .25 MM [.009 INCH... [See More]
- Technology: Wire Wound (Platinum)
- Accuracy: 0.1500
- Operating Temperature: 482
from Innovative Sensor Technology IST USA Division
The IST AG 850 °C Series is the successor of the 750 °C series offering temperature measurements from -200 °C to +850 °C. The 850 °C Series is characterized by excellent long-term stability and fast response time with low self-heating even in harsh conditions and extreme... [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: 100 to 1000
- Operating Temperature: -328 to 1562
- Sensor Type: Standard; Precision
from TE Connectivity
Configuration Features. Electrical Connection : Open End. Dimensions. Body Diameter : 2 MM [.078 INCH ]. Body Length : 10 MM [.39 INCH ]. Wire Diameter : .25 MM [.009 INCH... [See More]
- Technology: Wire Wound (Platinum)
- Accuracy: 0.1000
- Operating Temperature: 302
from Innovative Sensor Technology IST USA Division
The IST AG SMD Ni Temperature Sensor Series offers an excellent long-term stability and simple linearization within a temperature range of -60 °C to +150 °C (+250 °C upon request). The wireless sensors are vibration and temperature shock resistant with simple interchangeability... [See More]
- Technology: Wire Wound (Nickel)
- Nominal Resistance: 891
- Operating Temperature: -76 to 302
- Length: 0.0787
from TE Connectivity
Configuration Features. Electrical Connection : Open End. Dimensions. Body Diameter : 4.5 MM [.177 INCH ]. Body Length : 15 MM [.6 INCH ]. Wire Diameter : .25 MM [.009 INCH... [See More]
- Technology: Wire Wound (Platinum)
- Accuracy: 0.3000
- Operating Temperature: 752
from Innovative Sensor Technology IST USA Division
The wireless IST AG FlipChip series features Pt temperature sensors with excellent long-term stability, fast response time and low self-heating. The FlipChips are developed with contacts on one side resulting in no short-cut risk on the backside of the chip. Furthermore, IST AG offers different FC... [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: 100 to 1000
- Operating Temperature: -58 to 1112
- Sensor Type: Standard
from TE Connectivity
Configuration Features. Connector Type : Open Ends. Dimensions. Diameter (Body) : 4.5 MM [.177 INCH ]. Length (Body) : 15 MM [.6 INCH ]. Wire Diameter : .25 MM [.009 INCH... [See More]
- Technology: Wire Wound (Platinum)
- Accuracy: 0.1500
- Operating Temperature: -148 to 482
- Length: 0.6000
from Innovative Sensor Technology IST USA Division
IST AG offers wireless RTD Platinum SMD sensors for automatic PCB assembly processes with wrap-around contacts on both ends. We offer different SMD technologies for different applications and temperature ranges, e.g. SAC305-tinned wrap-around contacts for the normal PCB assembly process, high... [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: 100 to 1000
- Operating Temperature: -58 to 482
- Sensor Type: Standard; Precision
from TE Connectivity
Configuration Features. Electrical Connection : Open End. Dimensions. Body Diameter : 2.7 MM [.106 INCH ]. Body Length : 13 MM [.51 INCH ]. Wire Diameter : .25 MM [.009 INCH... [See More]
- Technology: Wire Wound (Platinum)
- Accuracy: 0.3000
- Operating Temperature: 752
from TE Connectivity
Configuration Features. Electrical Connection : Open End. Dimensions. Body Diameter : 2.7 MM [.106 INCH ]. Body Length : 13 MM [.51 INCH ]. Wire Diameter : .25 MM [.009 INCH... [See More]
- Technology: Wire Wound (Platinum)
- Accuracy: 0.1500
- Operating Temperature: 482
from TE Connectivity
Configuration Features. Electrical Connection : Open End. Dimensions. Body Diameter : 2.7 MM [.106 INCH ]. Body Length : 13 MM [.51 INCH ]. Wire Diameter : .25 MM [.009 INCH... [See More]
- Technology: Wire Wound (Platinum)
- Accuracy: 0.1000
- Operating Temperature: 302
from Baumer Ltd.
CombiTemp comprises a series of basic elements which can be combined to various temperature sensors and transmitters. The system includes 4-wire Pt100 cable sensors. Being a building block system CombiTemp offers a great flexibility in respect to modification, service and maintenance. A wide range... [See More]
- Technology: Wire Wound (Platinum)
- Sensor Type: Standard (optional feature); Precision (optional feature)
- Operating Temperature: -40 to 320
- Length: ? to 11.81
from Yageo Nexensos
Ceramic Wire wound Platinum RTD (Pt RTD) Elements are characterized by extremely high stability, high-temperature capability, and high accuracy over a wide temperature range. We offer a variety of ceramic wire wounds (both single and dual RTDs) in a wide choice of resistance values (Pt100, Pt200,... [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: 100
- Operating Temperature: -58 to 1220
- Sensor Type: Standard (optional feature); Precision (optional feature)
from RCD Components, Inc.
TEMPERATURE SENSING THIN-FILM PLATINUM TEMPERATURE SENSOR. Industry ’s lowest cost and widest selection!. Precision performance, excellent stability, fast response. Wide resistance range: 100 Ω , 500 Ω , 1000 Ω. Dual sensors available in a single package (Type PTD). Meets DIN... [See More]
- Technology: Wire Wound (Platinum)
- Response Time: 0.0800 to 80
- Operating Temperature: -58 to 1184
- Sensor Type: Standard; Precision
from U.S. Sensor
U.S. Sensor's thin film platinum RTDs (Pt-RTD) consist of a passivated thin film platinum element deposited on a ceramic substrate. Thin film Pt-RTDs provide cost advantages when compared to wirewound platinum resistance temperature detectors. The construction of a thin film RTD sensor is not... [See More]
- Technology: Thin Film; Wire Wound (Platinum)
- Nominal Resistance: 100 to 1000
- Operating Temperature: -50 to 500
from OMEGA Engineering, Inc.
Models SRTD-1 and SRTD-2 are polyimide insulated surface mount RTD temperature sensors designed to provide a practical method for measuring surface temperatures. These sensors are small and flexible, and their low mass has minimal thermal effect on the material being measured. They are ideally... [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: ? to 100
- Operating Temperature: -328 to 500
- Coefficient of Resistance: ? to 0.003850
from Thermometrics Corporation
Using the 2-wire method, the two wires that provide the RTD with its excitation current and the two wires across which the RTD voltage is measured are the same. [See More]
- Technology: Wire Wound (Platinum (optional feature), Nickel (optional feature), Copper (optional feature))
from Sensing Devices Inc.
Platinum Wirewound Elements. CD Series [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: 10
- Operating Temperature: -328 to 1382
- Coefficient of Resistance: 0.003920
from Minco
Use these elements for general purpose sensing in probes or equipment. PD models meet EN60751, Class B. Specifications. Temperature range: . Some elements may be used down to -269 °C in certain applications. Contact fac tory for advice on cryogenic use. Element Body: Glass-coated ceramic. [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: 100
- Operating Temperature: -4 to 1022
- Coefficient of Resistance: 0.003850
from Baumer Ltd.
Fully user-configurable, they are available with varied process connections in standard or hygienic designs. The sensors, transmitters and displays can be freely configured by the user and have a variety of process connectors which conform to standards and hygiene regulations. They come to you in... [See More]
- Technology: Wire Wound (Platinum)
- Sensor Type: Standard (optional feature); Precision (optional feature)
- Operating Temperature: -40 to 320
- Length: 0.7874 to 118
from Yageo Nexensos
Glass Wire wound Platinum RTD (Pt RTD) Elements are characterized by extremely high stability, high-temperature capability, and high accuracy over a wide temperature range. They are constructed by winding platinum (Pt) bands on a glass core, and sealing with glass. Other sizes and dual elements are... [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: 100
- Operating Temperature: -328 to 842
- Length: 0.3937
from RCD Components, Inc.
TEMPERATURE SENSING, PRECISION HI-TEMP PLATINUM, NICKEL, NICKEL IRON RTD's. RCD ’s Resistance Temperature Detectors are designed for tough industrial applications, and are utilized to sense or regulate air (PTC) or liquid (PTS) e nvironments. Series PTC feature an all-welded wirewound... [See More]
- Technology: Wire Wound (Platinum, Nickel (optional feature), Nickel-Iron (optional feature))
- Length: 0.5000 to 18
- Operating Temperature: -67 to 932
- Width / Diameter.: 0.1250 to 0.2500
from OMEGA Engineering, Inc.
OMEGA RTD elements can be used for a variety of temperature applications. Models are available for temperature ranges as broad as -200 to 850 °C. Dual element RTDs are also available for applications where two different instruments need to monitor the same temperature. [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: ? to 100
- Operating Temperature: -330 to 1560
- Response Time: 0.3000 to 1.4
from Thermometrics Corporation
In a three wire RTD one of the wires is connected to one side of the temperature element and the remaining two wires are connected to the other side of the element. [See More]
- Technology: Wire Wound (Platinum (optional feature), Nickel (optional feature), Copper (optional feature))
from Minco
Use these elements for general purpose sensing in probes or equipment. PD models meet EN60751, Class B. Specifications. Temperature range: . Some elements may be used down to -269 °C in certain applications. Contact fac tory for advice on cryogenic use. Element Body: Glass-coated ceramic. [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: 100
- Operating Temperature: -148 to 1022
- Coefficient of Resistance: 0.003850
from Baumer Ltd.
Fully user-configurable, they are available with varied process connections in standard or hygienic designs. The sensors, transmitters and displays can be freely configured by the user and have a variety of process connectors which conform to standards and hygiene regulations. They come to you in... [See More]
- Technology: Wire Wound (Platinum)
- Sensor Type: Standard (optional feature); Precision (optional feature)
- Operating Temperature: -40 to 320
- Length: 0.7874 to 118
from OMEGA Engineering, Inc.
The KN series RTD's are suitable for applications requiring extremely high temperature stability and high temperature shock resistance. Deviation from the IEC751 characteristic curve is minimal over the entire temperature range. The small diameter tolerances of the sensor body allow easy... [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: ? to 100
- Operating Temperature: -330 to 1110
- Response Time: 0.6000 to 0.7000
from Thermometrics Corporation
The optimum form of connection for RTDs is a four-wire circuit. It removes the error caused by mismatched resistance of the lead wires. [See More]
- Technology: Wire Wound (Platinum (optional feature), Nickel (optional feature), Copper (optional feature))
from Minco
Use these elements for general purpose sensing in probes or equipment. PD models meet EN60751, Class B. Specifications. Temperature range: . Some elements may be used down to -269 °C in certain applications. Contact fac tory for advice on cryogenic use. Element Body: Glass-coated ceramic. [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: 100
- Operating Temperature: -148 to 1022
- Coefficient of Resistance: 0.003850
from Baumer Ltd.
Fully user-configurable, they are available with varied process connections in standard or hygienic designs. The sensors, transmitters and displays can be freely configured by the user and have a variety of process connectors which conform to standards and hygiene regulations. They come to you in... [See More]
- Technology: Wire Wound (Platinum)
- Length: 3.46
- Operating Temperature: -40 to 185
- Width / Diameter.: 0.9449
from OMEGA Engineering, Inc.
The HSRTD Series Flexible RTD Temperature Sensor Probes are hermetically sealed at the sensor tip to provide continuous protection at the temperature measurement junction. The flexible sensor probe PFA cable forms a hermetic seal and electrically isolates the small RTD sensor, suited to a variety of... [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: ? to 100
- Operating Temperature: -76 to 500
- Sensor Type: Standard (optional feature); Precision (optional feature)
from Thermometrics Corporation
Universal design allows for quick thermocouple or RTD installation into existing twist-lock adapters. [See More]
- Technology: Wire Wound
from Minco
Use these elements for general purpose sensing in probes or equipment. PD models meet EN60751, Class B. Specifications. Temperature range: . Some elements may be used down to -269 °C in certain applications. Contact fac tory for advice on cryogenic use. Element Body: Glass-coated ceramic. [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: 500
- Operating Temperature: -148 to 1022
- Coefficient of Resistance: 0.003850
from Baumer Ltd.
Fully user-configurable, they are available with varied process connections in standard or hygienic designs. The sensors, transmitters and displays can be freely configured by the user and have a variety of process connectors which conform to standards and hygiene regulations. They come to you in... [See More]
- Technology: Wire Wound (Platinum)
- Length: 3.46
- Operating Temperature: -40 to 185
- Width / Diameter.: 0.9449
from OMEGA Engineering, Inc.
Glass wire wound platinum RTD elements are made by winding a platinum wire onto a glass core and then fusing the exterior with glass. They are suitable for low or very high temperatures and are tolerant of thermal shocks. They offer good vibration resistance (depending on mounting method) and can be... [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: ? to 100
- Operating Temperature: -365 to 1110
- Response Time: 0.3500 to 3
from Thermometrics Corporation
Recognition of rising temperature can provide a warning of the breakdown of the bearing lubricating oil film; thus allowing machine shutdown and maintenance to take place. Prevention is always better than replacment. [See More]
- Technology: Wire Wound
- Operating Temperature: -58 to 500
from Minco
Use these elements for general purpose sensing in probes or equipment. PD models meet EN60751, Class B. Specifications. Temperature range: . Some elements may be used down to -269 °C in certain applications. Contact fac tory for advice on cryogenic use. Element Body: Glass-coated ceramic. [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: 500
- Operating Temperature: -148 to 1022
- Coefficient of Resistance: 0.003850
from Baumer Ltd.
Fully user-configurable, they are available with varied process connections in standard or hygienic designs. The sensors, transmitters and displays can be freely configured by the user and have a variety of process connectors which conform to standards and hygiene regulations. They come to you in... [See More]
- Technology: Wire Wound (Platinum)
- Length: 3.46
- Operating Temperature: -40 to 185
- Width / Diameter.: 0.9449
from OMEGA Engineering, Inc.
Typical connection for sensors such as the CY7 series. The connection points (A) are made close to the sensor in the case of 4-lead measurement, and near or at the instrumentation for a 2-lead measurement. Generally, the 4-lead connection is preferred. [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: ? to 100
- Operating Temperature: -434 to 1112
- Length: 0.1969 to 0.7992
from Thermometrics Corporation
Field Adjustable Sensors are ideal for applications involving various sheath lengths that are best determined on site, rather than on an engineering drawing. [See More]
- Technology: Wire Wound
from Baumer Ltd.
Fully user-configurable, they are available with varied process connections in standard or hygienic designs. The sensors, transmitters and displays can be freely configured by the user and have a variety of process connectors which conform to standards and hygiene regulations. They come to you in... [See More]
- Technology: Wire Wound (Platinum)
- Length: 1.73
- Operating Temperature: -40 to 185
- Width / Diameter.: 0.7480
from OMEGA Engineering, Inc.
FR series elements are designed for applications where high vibration resistance as well as high temperature stability is vital. Typical industrial applications include analytical equipment, chemical plants and mechanical equipment. Small tolerances on diameter allow problem free installation in... [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: 100 to 1000
- Operating Temperature: -95 to 930
- Response Time: 2.7 to 4.6
from Thermometrics Corporation
Resistance thermometers,(RTDs), are temperature sensors that exploit the predictable change in electrical resistance of some materials with changing temperature. [See More]
- Technology: Wire Wound (Platinum)
from Baumer Ltd.
Fully user-configurable, they are available with varied process connections in standard or hygienic designs. The sensors, transmitters and displays can be freely configured by the user and have a variety of process connectors which conform to standards and hygiene regulations. They come to you in... [See More]
- Technology: Wire Wound (Platinum)
- Length: 1.73
- Operating Temperature: -40 to 185
- Width / Diameter.: 0.7480
from OMEGA Engineering, Inc.
All of OMEGA's RTD elements can be supplied with additional lead wire attached to existing leads. Longer leads create more flexibility for use in many applications. [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: ? to 100
- Operating Temperature: ? to 450
- Sensor Type: Standard (optional feature); Precision
from Thermometrics Corporation
PT100 sensors offer excellent accuracy over a wide temperature range (from -200 to +850 C). [See More]
- Technology: Wire Wound
- Operating Temperature: -328 to 1562
from Baumer Ltd.
Fully user-configurable, they are available with varied process connections in standard or hygienic designs. The sensors, transmitters and displays can be freely configured by the user and have a variety of process connectors which conform to standards and hygiene regulations. They come to you in... [See More]
- Technology: Wire Wound (Platinum)
- Length: 1.73
- Operating Temperature: -40 to 185
- Width / Diameter.: 0.7480
from OMEGA Engineering, Inc.
All of OMEGA's RTD elements can be supplied with additional lead wire attached to existing leads. Longer leads create more flexibility for use in many applications. [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: ? to 100
- Operating Temperature: ? to 450
- Sensor Type: Standard (optional feature); Precision
from Thermometrics Corporation
The Pt1000 has 1000 ohms resistance at 0 C. These sensors are normally fitted into some type of protective sheath or mounting to form a probe. [See More]
- Technology: Wire Wound
from Baumer Ltd.
Fully user-configurable, they are available with varied process connections in standard or hygienic designs. The sensors, transmitters and displays can be freely configured by the user and have a variety of process connectors which conform to standards and hygiene regulations. They come to you in... [See More]
- Technology: Wire Wound (Platinum)
- Length: 1.73
- Operating Temperature: -40 to 185
- Width / Diameter.: 1.04
from OMEGA Engineering, Inc.
All of OMEGA's RTD elements can be supplied with additional lead wire attached to existing leads. Longer leads create more flexibility for use in many applications. [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: ? to 100
- Operating Temperature: 450 to 900
- Sensor Type: Standard (optional feature); Precision
from Thermometrics Corporation
For measuring high temperatures you should use a sensor, which reliably works in rough environments, has a long expectancy of life andideally comes up with the space-saving concepts of the automotive industry. [See More]
- Technology: Wire Wound
- Operating Temperature: -94 to 1832
from Baumer Ltd.
Fully user-configurable, they are available with varied process connections in standard or hygienic designs. The sensors, transmitters and displays can be freely configured by the user and have a variety of process connectors which conform to standards and hygiene regulations. They come to you in... [See More]
- Technology: Wire Wound (Platinum)
- Length: 1.73
- Operating Temperature: -40 to 185
- Width / Diameter.: 1.04
from OMEGA Engineering, Inc.
All of OMEGA's RTD elements can be supplied with additional lead wire attached to existing leads. Longer leads create more flexibility for use in many RTD probe sensor applications. The size of the potted junction between lead wire and element is kept as small as possible. Note: These elements are... [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: ? to 100
- Operating Temperature: 450 to 900
- Sensor Type: Standard (optional feature); Precision
from Thermometrics Corporation
Sanitary RTD sensors provide precise temperature measurements for Sanitary applications found in the Food, Dairy, Beverage, Pharmaceutical and Chemical Industries. [See More]
- Technology: Wire Wound
from Baumer Ltd.
Fully user-configurable, they are available with varied process connections in standard or hygienic designs. The sensors, transmitters and displays can be freely configured by the user and have a variety of process connectors which conform to standards and hygiene regulations. They come to you in... [See More]
- Technology: Wire Wound (Platinum)
- Length: 1.73
- Operating Temperature: -22 to 185
- Width / Diameter.: 1.04
from OMEGA Engineering, Inc.
Mineral insulated metal sheathed RTD Cable , RTD MIC, has a stainless steel or Inconel outer metal sheath with copper or Nickel signal wire conductors. The conductor lead wires are insulated from each other and the outer sheath by compacted magnesium oxide MgO. Metric and standard US inch diameters... [See More]
- Technology: Wire Wound (Nickel)
- Width / Diameter.: 0.1250 to 0.2500
- Length: 0.0 to 12000
from Thermometrics Corporation
Weld Pad RTD and Thermocouple sensors are commonly used in Petro-Chemical industries. These sensors are welded to pipe to provide a measurement of process temperature. [See More]
- Technology: Wire Wound
from Baumer Ltd.
The wetted parts of the conical sensor are in acid-proof stainless steel. The sensor is available as a cable sensor with high-fl exible, 4-wire silicone cable. The conical sensor is ideal for measuring tem pe ra tu re in pipe systems and tanks. The sensor mounting is hygienic and without gasket in a... [See More]
- Technology: Wire Wound (Platinum)
- Sensor Type: Standard (optional feature); Precision (optional feature)
- Operating Temperature: -58 to 401
- Length: ? to 0.9843
from OMEGA Engineering, Inc.
The RTD-850 RTD sensor is designed for installation in #8-32 threaded holes or in thin items using a backing nut. Its small size allows for installation in tight spaces such as electronic equipment, power supples, equipment racks, motors, automated equipment, and many other places. The 100 Ohm Class... [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: ? to 100
- Operating Temperature: -76 to 446
- Coefficient of Resistance: ? to 0.003850
from Thermometrics Corporation
Wire wound elements are basically a "hand made" product which involves lot of skilled Labor. It is manufactured by placing a coil of thin wire into a ceramic insulator. The resistance of the coil is suitably adjusted to the ohms corresponding to that particular temperature. [See More]
- Technology: Wire Wound
from Baumer Ltd.
This measurement system enables temperature measurement without dead-zones in tubing. The rounded shape, adapted to the tube diameter, does not create additional flow resistance. Complete in-situ cleaning is possible with CIP (cleaning in process) or SIP (sterilisation in process) These products can... [See More]
- Technology: Wire Wound (Platinum)
- Sensor Type: Standard
- Operating Temperature: -4 to 185
- Length: 2.87 to 3.94
from OMEGA Engineering, Inc.
An economical industrial grade Class "B" RTD sensor in a convenient 3-pack. Typical Applications Include: Product Environmental and Performance Testing, Climate Control/HVAC, Thermal Protection of Electronic Products (Power Supplies, Electronic Racks, and EnclosuresTemperature) and Monitoring of... [See More]
- Technology: Wire Wound (Platinum)
- Nominal Resistance: ? to 100
- Operating Temperature: -60 to 445
- Accuracy: ? to 0.1200
from Baumer Ltd.
The measuring principle in the Pt100 temperature sensor is based on the relationship between resistance and tem pe ra tu re in platinum. The platinum sensor is manufactured in accordance with DIN/EN/IEC 751, e.g. 0 °C corresponds to 100 Ohm and 100 °C to 138.5 Ohm. The sensors are factory... [See More]
- Technology: Wire Wound (Platinum)
- Length: ? to 4.13
- Operating Temperature: -58 to 401
- Width / Diameter.: 0.2362
from Baumer Ltd.
The TE2 Pt100 temperature sensor system has a stainless steel case with a build-in plug. All models can be supplied with an integrated, configurable temperature transmitter with 4...20 mA output. The system complies with standard industrial process connections as well as hygienic connections with... [See More]
- Technology: Wire Wound (Platinum)
- Sensor Type: Standard (optional feature); Precision (optional feature)
- Operating Temperature: -40 to 185
- Length: 1.38 to 11.81
from Baumer Ltd.
The TE1 Pt100 temperature measurement system has a stainless steel field housing in excellent finish. The system complies standard industrial process connections as well as hygienic connections with high cleanability and bacteria tightness. Fast response sensor tips ensures accurate measurements. [See More]
- Technology: Wire Wound (Platinum)
- Sensor Type: Standard (optional feature); Precision (optional feature)
- Operating Temperature: -4 to 185
- Length: 1.38 to 11.81