Handheld Digital Resistance Meters
from Uni-Trend US
Digital Insulation Resistance Tester – 2500V, 2.5T Ω, Capacitance & Low Resistance Testing [See More]
- Form Factor: Handheld
- Standards and Certifications: RoHS
from RS Components, Ltd.
RS PRO 113A Multimeter [See More]
- Form Factor: Handheld
- Special Measurement Types: Continuity Check; Diode test
- Resistance: 3.40E-5
- Standards and Certifications: RoHS
from RS Components, Ltd.
RS PRO DT-118B Multimeter [See More]
- Form Factor: Handheld
- Standards and Certifications: RoHS
from RS Components, Ltd.
RS PRO DT-914 Multimeter [See More]
- Form Factor: Handheld
- Standards and Certifications: RoHS
- Special Measurement Types: Temperature
from RS Components, Ltd.
RS PRO DT-912 Multimeter [See More]
- Form Factor: Handheld
- Standards and Certifications: RoHS
from RS Components, Ltd.
RS PRO APPA 103N Multimeter [See More]
- Form Factor: Handheld
- Standards and Certifications: RoHS
from RS Components, Ltd.
RS PRO APPA 61 Multimeter [See More]
- Form Factor: Handheld
- Standards and Certifications: RoHS
- Special Measurement Types: Continuity Check; Diode test
from RS Components, Ltd.
RS PRO APPA 62T Multimeter [See More]
- Form Factor: Handheld
- Standards and Certifications: RoHS
- Special Measurement Types: Continuity Check; Diode test; Temperature
from RS Components, Ltd.
RS PRO APPA 71 Multimeter [See More]
- Form Factor: Handheld
- Standards and Certifications: RoHS
- Special Measurement Types: Continuity Check; Diode test; True RMS Current Measurement
from RS Components, Ltd.
RS PRO APPA 63N Multimeter [See More]
- Form Factor: Handheld
- Standards and Certifications: RoHS
- Special Measurement Types: Continuity Check; Diode test
from RS Components, Ltd.
RS PRO APPA 67 Multimeter [See More]
- Form Factor: Handheld
- Standards and Certifications: RoHS
- Special Measurement Types: Continuity Check; Diode test
from RS Components, Ltd.
RS PRO APPA 72 Multimeter [See More]
- Form Factor: Handheld
- Standards and Certifications: RoHS
- Special Measurement Types: Continuity Check; Diode test; True RMS Current Measurement
from RS Components, Ltd.
RS PRO APPA 73 Multimeter [See More]
- Form Factor: Handheld
- Standards and Certifications: RoHS
- Special Measurement Types: Continuity Check; Diode test; True RMS Current Measurement
from RS Components, Ltd.
RS PRO APPA 91 Multimeter [See More]
- Form Factor: Handheld
- Standards and Certifications: RoHS
- Special Measurement Types: Continuity Check; Diode test
from RS Components, Ltd.
RS PRO APPA 17 Multimeter [See More]
- Form Factor: Handheld
- Standards and Certifications: RoHS
from RS Components, Ltd.
RS PRO APPA IMETER-5 Multimeter [See More]
- Form Factor: Handheld
- Standards and Certifications: RoHS
- Special Measurement Types: Diode test; Temperature
from RS Components, Ltd.
RS PRO APPA 66RT Multimeter [See More]
- Form Factor: Handheld
- Standards and Certifications: RoHS
- Special Measurement Types: True RMS Current Measurement; Temperature
from RS Components, Ltd.
RS PRO APPA 93N-G Multimeter [See More]
- Form Factor: Handheld
- Standards and Certifications: RoHS
- Special Measurement Types: Diode test; Temperature
from RS Components, Ltd.
RS PRO APPA 17 Multimeter [See More]
- Form Factor: Handheld
- Standards and Certifications: RoHS
from RS Components, Ltd.
RS PRO APPA 106N Multimeter [See More]
- Form Factor: Handheld
- Standards and Certifications: RoHS
- Special Measurement Types: Continuity Check; Diode test; Max/Min or Peak spike measurement; True RMS Current Measurement; Temperature
from RS Components, Ltd.
RS PRO IDM505 Multimeter [See More]
- Form Factor: Handheld
- Standards and Certifications: RoHS
- Special Measurement Types: Continuity Check; Diode test; True RMS Current Measurement; Temperature
from RS Components, Ltd.
Fluke FLUKE-77-4/EUR Multimeter [See More]
- Form Factor: Handheld
from RS Components, Ltd.
Chauvin Arnoux P01191755 Multimeter [See More]
- Form Factor: Handheld
- Special Measurement Types: Continuity Check; Diode test
- Resistance: 3.00E-5
from RS Components, Ltd.
Chauvin Arnoux P01191757 Multimeter [See More]
- Form Factor: Handheld
- Special Measurement Types: Continuity Check; Diode test; True RMS Current Measurement
- Resistance: 3.00E-5
from RS Components, Ltd.
Fluke FLUKE-787B Multimeter [See More]
- Form Factor: Handheld
- Special Measurement Types: Diode test; True RMS Current Measurement
from RS Components, Ltd.
Klein Tools MM420 Multimeter [See More]
- Form Factor: Handheld
- Standards and Certifications: RoHS
- Special Measurement Types: Temperature
from Hoyt Electrical Instrument Works, Inc.
Full auto range for V.A and Ω functions. Data hold function freezes the reading in dimly lit or hard to reach places. Low battery indication. Built-in buzzer for continuity test. Safety design throughout with no exposed metal parts. Shielded banana plugs and recessed input terminals. Ohm... [See More]
- Form Factor: Clamp Meter; Handheld
- Resistance: 0.0 to 2
- Display Digits: 3 Digits; Plus a 1/2 digit
- Special Measurement Types: Audible Continuity; Continuity Check
from TEGAM, Inc.
Handheld Megohmmeter. 1 M Ω TO 200 M Ω, 500V, 3.5 Digit. The Model R1M-B Handheld Voltmeter/ Megohmmeter is designed to measure insulation resistance in "live" circuits, which may have voltage present. It can be connected to 600 V RMS AC or DC without damage, and its mode of operation is... [See More]
- Form Factor: Handheld
- Resistance: 1000 to 200000
- Display Digits: 3 Digits; Plus a 1/2 digit
- Operating Temp: 0.0 to 50
from Traceable® Products
Designed specifically for checking the electrical functions of scientific equipment in laboratories. Perfect unit to test batteries, fuses, recorder outputs, cables, wall plugs, probes, printed circuit boards, and complex electronic instrumentation. Save money and time by solving problems and... [See More]
- Form Factor: Handheld
- Resistance: 0.0 to 2000
- Display Digits: 4 Digits
- Special Measurement Types: Audible Continuity; Continuity Check
from SMC International
The microohmeter PME-100 is used to measure accurately the contact resistances of switches, circuits breakers, motor and transformers windings and others. The measurement is performed through the current evaluation and the voltage drop on the unknown resistance, with 4 wires to prevent against the... [See More]
- Form Factor: Handheld
- Operating Temp: 0.0 to 50
- Resistance: 2.00E-7 to 0.1999
- Options & Features: Auto-ranging; Battery powered
from AlphaLab, Inc.
The Model HR2 meter measures resistance in nine ranges from 1 ohm to 1.9999 Tera ohms (1.9999x1012 ohms), and conductance in a single range of 0.00 to 199.99 pS (pico siemens, or pico mhos), all at low voltage of < 2 volts across the sample. Basic accuracy is +/- 2% of reading +/- 1 count. For... [See More]
- Form Factor: Handheld
- Resistance: 20 to 2.00E9
- Display Digits: 5 Digits
- Options & Features: Battery powered
from REED-Direct
Accuracy of ± 0.01 ω. User selectable alarm threshold from 1 to 100 ω. Limit alarm. Measures leakage current to 1mA and neutral current to 20A. 1 second sampling time. 3-3/4 digit, 2000-count LCD with display Hold. Autoranging. Doubly insulated conductor clamp for extra security. [See More]
- Form Factor: Clamp Meter; Handheld
- Resistance: 0.0 to 1.2
- Display Digits: 3 Digits; Plus a 1/2 digit
- Options & Features: Has Alarm LED; Auto-ranging; Data storage/ logging
from Albér
The CRT-400, Alber's handheld Cellcorder utilizes the well-proven and patented DC Resistance Test to eliminate the guesswork when trying to identify a failing battery. ● Designed specifically to comply with IEEE Recommended Practices for Battery Maintenance and. Testing. ● DC Resistance... [See More]
- Form Factor: Handheld
- Special Measurement Types: Battery Test
- Operating Temp: 0.0 to 40
- Options & Features: Has Application Software for Host Computer; Battery powered; Data Acquisition; Data storage/ logging; Removable data storage
from Tinsley Precision Instruments
Analog Digital Multimeter which measures VAC, VDC, VAC+DC,Frequency, mA DC, mA (AC+DC), Resistance, continuity, Diode, Farad, AC current measurement. Features. Automatic terminal blocking system (ABS). Min/Max value storage. Indication of negative values on the analog scale. Overload warning [See More]
- Form Factor: Handheld
- Options & Features: Battery powered; Overload Protection
- Special Measurement Types: Continuity Check; Diode test
from Brighton Electronics, Inc.
CE Approved, UL Listed, 5 Year Warranty [See More]
- Form Factor: Handheld
- Resistance: 20 to 200
- Display Digits: 3 Digits; Plus a 1/2 digit
- Bandwidth: 45 to 450
from Greenlee Textron, Inc.
DIGITAL TYPE. 0.5 PERCENT DC CURRENT, 1 PERCENT DC CURRENT, 0.2 PERCENT DC VOLTAGE, 1 PERCENT AC VOLTAGE, 0.5 PERCENT RESISTANCE ACCURACY. BACKLIT LCD DISPLAY TYPE. UL (CANADA AND US), CE APPROVAL. (2) 1.5 V AAA BATTERY TYPE. TEST LEAD, CARRYING CASE, PROTECTIVE BOOT, BEAD TEMPERATURE PROBE... [See More]
- Form Factor: Handheld
- Special Measurement Types: Battery Test; Continuity Check; True RMS Current Measurement; Temperature
- Resistance: 0.6000 to 60000
- Options & Features: Battery powered
from OMEGA Engineering, Inc.
bull;. GS-Mark EN61010-1 Approval, Over-Voltage Category II 600 Vdc/Vac; Pollution Degree. •. Models: HHM26 and HHM28 have RS-232 Interface. •. Safety Input Jacks. •. Logic Probe Tester Models: HHM15, HHM20, HHM23. •. Temperature Measurement Models: HHM19, HHM21. •. [See More]
- Form Factor: Handheld
- Resistance: 0.0 to 43000
- Display Digits: 4 Digits
- Special Measurement Types: Diode test
from SMC International
The low resistance ohmeter PME-10 is used to measure accurately the contact resistances of switches, circuits breakers, motor and transformers windings and others. The measurement is performed through the current evaluation and the voltage drop on the unknown resistance, with 4 wires to prevent... [See More]
- Form Factor: Handheld
- Operating Temp: 0.0 to 50
- Resistance: 2.00E-7 to 0.1999
- Options & Features: Auto-ranging; Battery powered
from AlphaLab, Inc.
The HRLC meter measures resistance in six ranges from 1 K ohm to 1.9999 T ohms (1.9999x1012 ohms), and conductance in two ranges. covering from 0.001 pico siemens (pS) to 19.999 nano siemens (nS), all at low voltage of < 4 volts. Basic accuracy is +/- 2% of reading +/- 1 count. The highest... [See More]
- Form Factor: Handheld
- Resistance: 19999 to 2.00E9
- Display Digits: 5 Digits
- Options & Features: Battery powered
from REED-Direct
Resistance measurements to 4000 ω. Continuity test with beeper. 600V AC/DC test voltage range. Data hold switch. Test button may be locked on for hands-free operation. Automatic discharge when test button is released. Low battery indication. Supplied with soft carrying case and leads [See More]
- Form Factor: Handheld
- Special Measurement Types: Audible Continuity; Continuity Check
- Resistance: 0.0 to 4
- Options & Features: Battery powered
from Tinsley Precision Instruments
Analog Digital Multimeter which measures VAC, VDC, VAC+DC,Frequency, mA DC, mA (AC+DC), Resistance, continuity, Diode, Farad, AC current measurement. Features. Automatic terminal blocking system (ABS). Min/Max value storage. Indication of negative values on the analog scale. Overload warning [See More]
- Form Factor: Handheld
- Special Measurement Types: Continuity Check; Diode test
- Display Digits: 4 Digits
- Options & Features: Battery powered; Overload Protection
from Greenlee Textron, Inc.
DIGITAL TYPE. 0.8 PERCENT DC VOLTAGE, 1.2 PERCENT AC VOLTAGE, 1 PERCENT RESISTANCE ACCURACY. DIGITAL DISPLAY TYPE. UL (CANADA AND US) APPROVAL. 9 V BATTERY TYPE. AC/DC VOLTAGE, RESISTANCE PARAMETER MEASURED. 200/2000 OHM, 20/200/2000 KILO OHM RESISTANCE RANGE. 200/600 V AC VOLTAGE RANGE. 20/200/600... [See More]
- Form Factor: Handheld
- Options & Features: Battery powered
- Resistance: 0.2000 to 2000
from OMEGA Engineering, Inc.
The HHM220 is a compact handheld clamp meter which measures AC current. It can measure up to 400 ACA with 0.01A resolution up to 20 amps. It also has a hold feature to capture readings for later viewing. Standard accuracy is +/- 2% RDG + 5 digits. The HHM221 is a pocket size mini clamp meter which... [See More]
- Form Factor: Clamp Meter; Handheld
- Resistance: 0.0 to 0.2000
- Display Digits: 3 Digits; Plus a 1/2 digit
- Operating Temp: 0.0 to 40
from Greenlee Textron, Inc.
DIGITAL TYPE. +/- (1.2 PERCENT +6) DC VOLTAGE MAXIMUM, +/- (2.5 PERCENT +6) AC VOLTAGE MAXIMUM, +/- (2 PERCENT + 0.04) RESISTANCE MAXIMUM, +/- (0.05 PERCENT + 0.01) FREQUENCY MAXIMUM, +/- (1.6 PERCENT +4) CAPACITANCE MAXIMUM ACCURACY. LCD DISPLAY TYPE. UL (CANADA AND US), CE APPROVAL. TEST LEAD,... [See More]
- Form Factor: Handheld
- Special Measurement Types: Continuity Check; True RMS Current Measurement
- Resistance: 0.6000 to 60000
from OMEGA Engineering, Inc.
•. Special non- contact voltage feature: Meter buzzes when placed near live electrical circuits - HHM34 Unit ONLY!. •. Low Cost - High Value! [See More]
- Form Factor: Handheld
- Resistance: 0.0 to 30000
- Display Digits: 3 Digits; Plus a 1/2 digit
- Special Measurement Types: Diode test
from Greenlee Textron, Inc.
DIGITAL TYPE. 0.8 PERCENT DC VOLTAGE, 0.8 PERCENT AC VOLTAGE, 1 PERCENT DC CURRENT, 1.8 PERCENT AC CURRENT, 1 PERCENT RESISTANCE ACCURACY. BACKLIT LCD DISPLAY TYPE. UL, CUL, CSA, CE APPROVAL. -4 TO 1832 DEG F TEMPERATURE RANGE. AC/DC VOLTAGE, AC/DC CURRENT, RESISTANCE, TEMPERATURE, FREQUENCY, DUTY... [See More]
- Form Factor: Handheld
- Special Measurement Types: Battery Test; Temperature
- Resistance: 4.00E-6 to 400
from OMEGA Engineering, Inc.
•. Large 3 1 /2 or 3 3 /4 Display. •. AC/DC Current. •. Resistance Measurement. •. Capacitance Measurement. •. Continuity Check Feature [See More]
- Form Factor: Handheld
- Resistance: 0.2000 to 32000
- Display Digits: 3 Digits; Plus a 1/2 digit
- Special Measurement Types: Continuity Check
from Greenlee Textron, Inc.
DIGITAL TYPE. 0.5 PERCENT DC CURRENT, 1 PERCENT DC CURRENT, 0.2 PERCENT DC VOLTAGE, 1 PERCENT AC VOLTAGE, 0.5 PERCENT RESISTANCE ACCURACY. BACKLIT LCD DISPLAY TYPE. UL (CANADA AND US), CE APPROVAL. (2) 1.5 V AAA BATTERY TYPE. TEST LEAD, CARRYING CASE, PROTECTIVE BOOT, BEAD TEMPERATURE PROBE... [See More]
- Form Factor: Handheld
- Special Measurement Types: Battery Test; Continuity Check; True RMS Current Measurement; Temperature
- Resistance: 0.6000 to 60000
- Options & Features: Battery powered
from OMEGA Engineering, Inc.
bull;. Brand New Series with CE-Mark Approval. •. Highly Accurate Thermometer with K type Thermocouple (HHM63C/HHM63F/HHM63K). •. DATA HOLD Function. •. Models with 0.1 °, 1 ° Resolution. •. Auto-Ranging. •. Stick-Type Easy-to-Hold Design. •. Accuracy: Stated... [See More]
- Form Factor: Handheld
- Special Measurement Types: Diode test (optional feature); Temp - T/C
- Display Digits: 3 Digits; Plus a 1/2 digit
- Options & Features: Overload Protection
from Greenlee Textron, Inc.
DIGITAL TYPE. 1 PERCENT DC CURRENT, 0.6 PERCENT DC CURRENT, 0.06 PERCENT DC VOLTAGE, 60 PERCENT AC VOLTAGE, 0.1 PERCENT RESISTANCE ACCURACY. DUAL BACKLIT LCD DISPLAY TYPE. UL (CANADA AND US), CE APPROVAL. (1) 9 V BATTERY TYPE. TEST LEAD, CARRYING CASE, PROTECTIVE BOOT, BEAD TEMPERATURE PROBE... [See More]
- Form Factor: Handheld
- Special Measurement Types: Continuity Check
- Resistance: 6.00E-6 to 600
- Options & Features: Battery powered
from Greenlee Textron, Inc.
DIGITAL TYPE. 0.2 PERCENT DC CURRENT, 0.6 PERCENT DC CURRENT, 0.06 PERCENT DC VOLTAGE, 60 PERCENT AC VOLTAGE, 0.1 PERCENT RESISTANCE ACCURACY. DUAL BACKLIT LCD DISPLAY TYPE. UL (CANADA AND US), CE APPROVAL. (1) 9 V BATTERY TYPE. TEST LEAD, CARRYING CASE, PROTECTIVE BOOT, BEAD TEMPERATURE PROBE... [See More]
- Form Factor: Handheld
- Special Measurement Types: Continuity Check
- Resistance: 6.00E-6 to 600
- Options & Features: Battery powered
from Greenlee Textron, Inc.
DIGITAL TYPE. 1 PERCENT DC VOLTAGE, 0.3 PERCENT AC VOLTAGE, 0.1 PERCENT DC CURRENT, 0.5 PERCENT AC CURRENT, 0.07 PERCENT RESISTANCE ACCURACY. 5-5/6 DIGITAL 500000 COUNT, BACKLIT DISPLAY TYPE. UL, CUL, CSA, CE APPROVAL. (1) 9 V BATTERY TYPE. TEST LEAD, CARRYING CASE, PROTECTIVE BOOT, BEAD TEMPERATURE... [See More]
- Form Factor: Handheld
- Resistance: 0.5000 to 50000
- Display Digits: 6 Digits
- Special Measurement Types: Continuity Check; Temperature
from Greenlee Textron, Inc.
DIGITAL TYPE. 0.1 PERCENT DC VOLTAGE, 0.5 PERCENT AC VOLTAGE, 0.2 PERCENT DC CURRENT, 0.6 PERCENT AC CURRENT, 0.1 PERCENT RESISTANCE ACCURACY. BACKLIT DISPLAY TYPE. UL, CSA, CE APPROVAL. (1) 9 V BATTERY TYPE. TEST LEAD, CARRYING CASE, PROTECTIVE BOOT, BEAD TEMPERATURE PROBE INCLUSION. -58 TO 1832... [See More]
- Form Factor: Handheld
- Special Measurement Types: Continuity Check; Temperature
- Resistance: 0.0500 to 50000
- Options & Features: Battery powered
from Greenlee Textron, Inc.
DIGITAL TYPE. 0.6 PERCENT DC VOLTAGE, 0.5 PERCENT AC VOLTAGE, 0.2 PERCENT DC CURRENT, 0.6 PERCENT AC CURRENT, 0.1 PERCENT RESISTANCE ACCURACY. BACKLIT LCD DISPLAY TYPE. UL, CUL, CSA, CE APPROVAL. (1) 9 V BATTERY TYPE. TEST LEAD, CARRYING CASE, PROTECTIVE BOOT, BEAD TEMPERATURE PROBE INCLUSION. -58... [See More]
- Form Factor: Handheld
- Special Measurement Types: Continuity Check; Temperature
- Resistance: 6.00E-6 to 600
- Options & Features: Battery powered
from Greenlee Textron, Inc.
DIGITAL TYPE. 0.6 PERCENT DC VOLTAGE, 0.5 PERCENT AC VOLTAGE, 0.2 PERCENT DC CURRENT, 0.6 PERCENT AC CURRENT, 0.1 PERCENT RESISTANCE ACCURACY. BACKLIT LCD DISPLAY TYPE. UL, CUL, CSA, CE APPROVAL. (1) 9 V BATTERY TYPE. TEST LEAD, CARRYING CASE, PROTECTIVE BOOT, BEAD TEMPERATURE PROBE INCLUSION. -58... [See More]
- Form Factor: Handheld
- Special Measurement Types: Continuity Check; Temperature
- Resistance: 6.00E-6 to 600
- Options & Features: Battery powered
from Greenlee Textron, Inc.
DIGITAL TYPE. UL, CUL, CE APPROVAL. (2) 1.5 V AAA BATTERY TYPE. TEST LEAD, BEAD TEMPERATURE PROBE INCLUSION. -4 TO 572 DEG F TEMPERATURE RANGE. AC/DC VOLTAGE, AC/DC CURRENT, RESISTANCE, CAPACITANCE, FREQUENCY, TEMPERATURE PARAMETER MEASURED. 250.0 OHM, 2.500/25.00/250.0 KILO OHM, 2.500/25.00 MEGA... [See More]
- Form Factor: Handheld
- Special Measurement Types: Temperature
- Resistance: 0.2500 to 25000
- Options & Features: Battery powered
from Greenlee Textron, Inc.
DIGITAL TYPE. 0.5 PERCENT DC VOLTAGE, 1.5 PERCENT AC VOLTAGE, 1 PERCENT RESISTANCE ACCURACY. LCD DISPLAY TYPE. UL, CUL, CSA, CE APPROVAL. (1) CR2032 3 V BATTERY TYPE. CARRYING CASE INCLUSION. AC/DC VOLTAGE, RESISTANCE, CAPACITANCE, FREQUENCY, CONTINUITY PARAMETER MEASURED. 600 OHM, 6/60/600 KILO... [See More]
- Form Factor: Handheld
- Special Measurement Types: Continuity Check
- Resistance: 0.6000 to 6000
- Options & Features: Battery powered