Supplier: SAE International
Description: only requires one period of the lowest frequency. For a given frequency range of 0.1 Hz to approximately 2 kHz, the measurement duration would only be ten seconds. The battery response is captured and synchronously detected for impedance spectra measurements. This
-
Supplier: ValueTronics International, Inc.
Description: Resolution to 0.001dB, 0.01º - capturing every detail Measures impedances >100Mohm 2-, 3- and 4-terminal measurement configurations Rapid acquisition of data Accurate, repeatable measurements Corrosion studies Battery research
-
Supplier: SAE International
Description: Harmonic Compensated Synchronous Detection (HCSD) is a technique that can be used to measure wideband impedance spectra within seconds based on an input sum-of-sines signal having a frequency spread separated by harmonics. The battery (or other energy storage device) is excited with a
-
-
Supplier: Hoyt Electrical Instrument Works, Inc.
Description: Large LCD display 68 x 34mm(1.338" x 2.677"). True measurement of speaker systems actual impedance at 1kHz. Three test ranges allow testing of home theatre and commercial sound systems. Measures transformer impedances. Battery operation. Low battery indication.
- Measurement Type: AC / DC
-
Supplier: SAE International
Description: novel approach for internal cell temperature measurement is proposed applying on board impedance spectroscopy. The method considers the temperature coefficient of the complex internal cell impedance. It can be observed by current and voltage measurements as usually
-
Supplier: BTECH, Inc.
Description: impedance measurements for a complete battery monitoring system. All of this data can be viewed in real time using BTECH’s legendary Battery Validation Manager Software and reported using an existing BMS system. Measurement Capabilities At-a-Glance R/YG LED display
- Form: Test Module / Sub-system
- Test Capability: Charge / Condition, Impedance / AC Testing
- Voltage: 2 to 480 volts
-
Supplier: BTECH, Inc.
Description: Remote Telecommunications, UPS systems, Station Battery systems and Switchgear and is competitively priced while offering increased sensitivity, accuracy and repeatability. Key System Features The CellQ 1 will record and trend unit voltage, unit impedance, pilot cell temperatures
- Form: Test Station / System
- Test Capability: Charge / Condition, Impedance / AC Testing
- Voltage: 2 to 60 volts
-
Supplier: SAE International
Description: Battery aging is a main concern within hybrid and electrical cars. Determining the current state-of-health (SOH) of the battery on board of a vehicle is still a challenging task. Electrochemical Impedance Spectroscopy (EIS) is an established laboratory method for the
-
Supplier: BTECH, Inc.
Description: Graphically Displays Data By Location, Date, And Unit (Cell Or Jar) Number Displays Voltage And Impedance Trends Easy To Use With Context-Sensitive Help Screens Displays Total Battery Voltage, Unit Voltage, Unit Impedance, Ambient And Battery Case
- Applications: Predictive Maintenance
-
Supplier: ValueTronics International, Inc.
Description: speed. Additionally, these instruments provide auxiliary measurement parameters inductance, capacitance, dissipation factor, impedance, quality factor, reactance, and phase angle in degrees and radians. The BA6010 Series is suitable for characterizing battery chemistries that
- Form Factor: Portable / Handheld Tester
- Test Capability: Charge, Voltage, Resistance
-
Supplier: ValueTronics International, Inc.
Description: . Additionally, these instruments provide auxiliary measurement parameters inductance, capacitance, dissipation factor, impedance, quality factor, reactance, and phase angle in degrees and radians. The BA6010 Series is suitable for characterizing battery chemistries that are
- Form Factor: Portable / Handheld Tester
- Test Capability: Charge, Voltage
-
Supplier: ValueTronics International, Inc.
Description: on users’ criteria. The Megger BITE 3 Battery Impedance Test Equipment determines the health of lead-acid cells up to 2000 Ah by taking measurements of the most important battery parameters. The BITE 3 measures cell impedance, an internal ohmic test, cell voltage,
- Form Factor: Portable / Handheld Tester
- Test Capability: Charge, Voltage
-
Supplier: BTECH, Inc.
Description: , including cells with high amp hour ratings (4000+). KEY FEATURES Monitors battery parameters in real time Programmed cell impedance measurement up to 24/day Programmable test & out-of-limits alarms Battery discharge data logging
- Features: Alarm / Relay, Power Management / Control
- Form Factor: Panel / Rack Mount Tester
- Input Voltage: 24 to 250 volts
- Operating Temperature: -35.56 to 71.11 C
-
Supplier: Albér
Description: Warning for Battery Problems The BDS-40 uses a patented internal DC resistance test method that bypasses the limitations of AC based impedance testing. Like an ultrasound for a battery, Albér technology lets you "look inside" and assess the battery’s true state of health.
- Features: Alarm / Relay, Test Software / Computer Interface
- Form Factor: Panel / Rack Mount Tester
- Input Current: 2000 milliamps
- Input Voltage: 115 volts
-
Description: Electromagnetic vibration table is widely used in defense, aviation, aerospace, communications, electronics, automobiles, home appliances, and other industries. This type of equipment is used for discovering the early faults, simulating the actual working condition and the structure strength test,
- Application: Accelerometer Calibration, Mechanical Impedance Measurements, Product Qualification / Testing, Reliability / Durability Testing, R&D / Product Design Verification, Seismic Simulation, Semiconductors / Electronics Screening, Structural Fatigue Testing, Transportation / Aerospace
- Displacement: 0.9843 to 5.91 inch
- Frequency Range: 1 to 3500 Hz
- Integral Slip Table / Multi-Axis Capability: Yes
-
Supplier: M.A.E. Apparecchiature Elettroniche srl
Description: Max. Power: 250W Input time: can be set from 0,25 sec. (graphic visualization of the wave set) Measure precision: ±0,2µA Potential measurement: Auto range Max. Full scale: ±25V Input impedance: 2,5 MOHM
-
Supplier: Tinsley Precision Instruments
Description: The Tinsley QJ23 is a stable and accurate Wheatstone bridge for resistance measurements. The 4 Rheostat decades may also be used as an adjustable 4-dial decade resistance box. Self-contained with built-in galvanometer and batteries, the QJ23 is housed in a lightweight, durable
- Calibrator Style: Portable
- Display Type: Analog Meter or Indicator
- Electrical Properties: Resistance/ Impedance
- Local Interface: Analog Front Panel
-
Supplier: Tinsley Precision Instruments
Description: The Tinsley QJ49 is a highly stable, precision Wheatstone Bridge for the precision measurement of meters, components, windings and other instruments. It also be used as an adjustable 5-dial decade resistance box. Self-contained with built-in galvanometer and batteries, the QJ49 is
- Calibrator Style: Portable
- Display Type: Analog Meter or Indicator
- Electrical Properties: Resistance/ Impedance
- Local Interface: Analog Front Panel
-
Supplier: Tinsley Precision Instruments
Description: The Tinsley QJ57 is a self-contained portable DC Kelvin Bridge for high precision measurements of low resistance, conductivity and the calibration of other instruments. Suitable for laboratories, workshop and on-site, in the field applications. Specifications
- Calibrator Style: Portable
- Display Type: Analog Meter or Indicator
- Electrical Properties: Resistance/ Impedance
- Local Interface: Analog Front Panel
-
Supplier: RS Components, Ltd.
Description: . Frequency counter on AC mode. Capacitance measurement. Temperature measurement. Low battery indicator with segments. Auto Power Off (20 min). CAT. IV 600 V / CAT. III 1000 V Safety standard Absolute Maximum AC Current Measurement = 10A ac Absolute Maximum DC Current
- Electrical Measurements: True RMS Measurement, Other
- Resistance / Impedance Range: 40000 kohms
-
Supplier: RS Components, Ltd.
Description: . Frequency counter on AC mode. Capacitance measurement. Temperature measurement. Low battery indicator with segments. Auto Power Off (20 min). CAT. IV 600 V / CAT. III 1000 V Safety standard Absolute Maximum DC Current Measurement = 10A dc Absolute Maximum AC Current
- Electrical Measurements: True RMS Measurement, Other
- Resistance / Impedance Range: 40000 kohms
-
Supplier: RS Components, Ltd.
Description: . Frequency counter on AC mode. Capacitance measurement. Temperature measurement. Low battery indicator with segments. Auto Power Off (20 min). CAT. IV 600 V / CAT. III 1000 V Safety standard Absolute Maximum AC Current Measurement = 10A ac Absolute Maximum DC Current
- Electrical Measurements: True RMS Measurement, Other
- Resistance / Impedance Range: 40000 kohms
-
Supplier: Uni-Trend US
Description: system coverage LoZ Mode: 600V low impedance measurement eliminates ghost voltage readings Resistance: Multiple ranges up to 60MO for detailed circuit analysis Capacitance: Measure up to 60mF for motor start capacitor testing
- AC Current Range: 600 amps
- AC Voltage Range: 1000 volts
- DC Current Range: 600 amps
- DC Voltage Range: 1000 volts
-
Supplier: Tinsley Precision Instruments
Description: performed automatically before each measurement. It is also possible to measure just one phase if required. An adjustable set value permits the display of any error or deviation from the required transformation ratio. It is also possible for the 4167F to control the transformer tap changer
- Features: Battery Powered, Computer Interface, Printer / Plotter Interface
- Form Factor: Other
- Input Voltage: 8 to 240 volts
- Operating Humidity: 0.0 to 90 % (non-condensing)
-
Supplier: RS Components, Ltd.
Description: AC mode. Capacitance measurement. Low battery indicator with segments. Auto Power Off (20 min). CAT. IV 600 V / CAT. III 1000 V Safety standard Absolute Maximum DC Current Measurement = 10A dc Absolute Maximum AC Current Measurement = 10A ac Absolute Maximum Resistance
- Electrical Measurements: True RMS Measurement
- Resistance / Impedance Range: 40000 kohms
-
Supplier: Columbia Research Labs, Inc.
Description: high level low impedance output and require no additional signal conditioning. Consult the factory for customized versions of these sensors. Features High Sensitivity High Performance Fluid Rotor Design
- Acceleration: 0.1000 to 300 g
- Features: Battery Powered, Other
- Frequency Range: 1 to 1000 Hz
- Linear Velocity: 0.1000 to 300 in/sec
-
Supplier: OMEGA Engineering, Inc.
Description: . Simultaneous Source and Measurement for Process Devices In conventional calibration applications, multiple devices such as a standard generator, dial resistor and multimeter were required. Now with a single CA150 unit, it is possible to perform operation check at regular inspection and
- AC Current: Yes
- AC Current Range: 1400 amps
- AC Voltage: Yes
- AC Voltage Range: 100 to 240 volts
-
Supplier: OMEGA Engineering, Inc.
Description: cables, and you're ready to take measurements. A wide array of useful functions are offered. Including: Source (output can be set in steps: Power; Transmitter; Divided (n/M, eliminating need for calculations for percentage output); Autostep (changes can be sourced every 10% or 25%); online
- AC Voltage: Yes
- AC Voltage Range: 120 to 230 volts
- Calibrator Style: Portable, Battery Powered, Other Specific Calibration?
- DC Current: Yes
-
Supplier: Venable Instruments
Description: (PITT)Galvanostatic Intermittent Titration (GITT)AC Voltammetry Learn More Battery Testing Applications Applications Corrosion Measurement Energy Device Testing {e.g., Batteries]Electrolys is Fuel Cells Coating Evaluation Sensors THE VENABLE DIFFERENCE Features that Put You in
- Energy Storage Products Tested: Specialty / Other
- Form: Test Station / System
- Test Capability: Charge / Condition, Impedance / AC Testing, Other
-
Description: ; - powered by battery and/or from the circuit measured, and - portable. Examples of such EUTs include, but are not limited to, voltage detectors, insulation testers, earth continuity testers, earth resistance testers, leakage current clamps, loop impedance testers,
-
Supplier: Beamex Oy Ab
Description: certificates automatically. All-in-One Functionality: The MC4 is a versatile calibrator with many different functions. There’s no need to take several different measurement devices to the field, MC4 does the job. Accuracy Guaranteed:
- Calibrator Style: Hand Held, Portable, Modular, Battery Powered
- Display Type: Video Display Terminal
- Electrical Properties: Resistance/ Impedance
- Local Interface: Digital Front Panel
-
Description: battery and/or from the circuit measured, and - portable. Examples of such EUTs include, but are not limited to, voltage detectors, insulation testers, earth continuity testers, earth resistance testers, leakage current clamps, loop impedance testers, “residual-current-de vice-testers”
-
Supplier: Beamex Oy Ab
Description: Temperature (1 year uncertainty): From 0.10°C (RTD measurement) From 0.20°C (TC measurement) Electrical (1 year uncertainty): Typically 0.02 % rdg + small adder Pressure (1 year uncertainty): From 0.025 % rdg + 0.01 % FS (EXT-IS) From 0.05 % FS (EXT-s-IS)
- Calibrator Style: Hand Held, Modular, Battery Powered
- DC Voltage: Yes
- DC Voltage Range: 24 volts
- Display Type: Video Display Terminal
-
Supplier: Uni-Trend US
Description: RMS accuracy DC Current: Complete 600A range plus 2000µA precision measurement AC/DC Voltage: Test up to 1000V for comprehensive system coverage LoZ Mode: 600V low impedance measurement eliminates ghost voltage readings Resistance:
- AC Current Range: 600 amps
- AC Voltage Range: 1000 volts
- Capacitance Range: 60 microF
- DC Current Range: 600 amps
-
Supplier: Uni-Trend US
Description: DC Current: Complete 600A range plus 2000µA precision measurement AC/DC Voltage: Test up to 1000V for comprehensive system coverage LoZ Mode: 600V low impedance measurement eliminates ghost voltage readings Resistance: Multiple ranges up to
- AC Current Range: 600 amps
- AC Voltage Range: 1000 volts
- Capacitance Range: 60 microF
- DC Current Range: 600 amps
-
Supplier: Venable Instruments
Description: Titration (PITT)Galvanostatic Intermittent Titration (GITT)AC Voltammetry Learn More Battery Testing Applications Applications Corrosion Measurement Energy Device Testing {e.g., Batteries]Electrolys is Fuel Cells Coating Evaluation Sensors THE VENABLE DIFFERENCE Features that
- Current Test Range: 1 to 5 amps
- Form Factor: Test Station / System
- Input Current: 2.50E-8 milliamps
- Test Capability: Voltage, Current, Other
-
Supplier: Columbia Research Labs, Inc.
Description: VDC. The low power requirement allows operation from battery sources for portable or remote applications. Features Seismic Sensors Low Impedance Output Choice of Sensitivities Electrical Isolation Hermetically Sealed Battery Power (+12 VDC)
- Acceleration: -2.5 to 2.5 g
- Device Type: Sensor / Transducer
- Features: Battery Powered, Sealed
- Frequency Range: 0.0100 to 1500 Hz
-
Supplier: Columbia Research Labs, Inc.
Description: VDC. The low power requirement allows operation from battery sources for portable or remote applications. Features Seismic Sensors Low Impedance Output Choice of Sensitivities Electrical Isolation Hermetically Sealed Battery Power (+12 VDC)
- Acceleration: -5 to 5 g
- Device Type: Sensor / Transducer
- Features: Battery Powered, Sealed
- Frequency Range: 0.0100 to 1500 Hz
-
Supplier: OMEGA Engineering, Inc.
Description: The OMEGAROMETER series accelerometers are designed for industrial vibration measurements. They feature a hermetically sealed 316L stainless steel case suitable for harsh environments. The ACC786A is a general purpose accelerometer with a top cable exit.SPECIFICATIONSD YNAMICSensitivity
- Acceleration: 80 g
- Device Type: Sensor / Transducer
- Features: Battery Powered, Corrosion Resistant, Sealed
- Frequency Range: 0.5000 to 14000 Hz
-
Supplier: Columbia Research Labs, Inc.
Description: The Model 962 Piezoelectric Accelerometer is designed for the measurement of high frequency, moderate to high-level shock and vibration. It incorporates a hybrid electronic assembly within a rugged, welded, double-wall stainless steel body to enhance its operation in humid and dirty
- Acceleration: -1.75 to 1.75 g
- Device Type: Sensor / Transducer
- Features: Battery Powered, Sealed
- Frequency Range: 0.0100 to 1500 Hz
-
Supplier: Win Source Electronics
Description: Win Source Part Number: 1209731-AD7755ARS Category: Integrated Circuits (ICs)>PMIC - Energy Metering Series: AD7755 Package: Bulk Standard Package: 1 Mounting: SMD (SMT) Current - Supply: 2mA Input Impedance: 390kOhm Measurement Error: 0.1% Voltage - I
- Operating Temperature: -40 to 85 C
- Output Options: Inverting
- Package Type: SSOP
- Supply Voltage (Vi): 4.5 to 5.5 volts
-
Supplier: Win Source Electronics
Description: Win Source Part Number: 1180875-71M6532D-IGT R/F Category: Integrated Circuits (ICs)>PMIC - Energy Metering Series: Single Converter Technology® Package: Tape & Reel Standard Package: 1,000 Mounting: SMD (SMT) Input Impedance: 40kOhm ~ 90k
- Operating Temperature: -40 to 85 C
- Output Options: Inverting
- Supply Voltage (Vi): 3 to 3.6 volts
-
Supplier: Win Source Electronics
Description: Win Source Part Number: 1156251-ADE7756AN Category: Integrated Circuits (ICs)>PMIC - Energy Metering Package: Tube Standard Package: 18 Current - Supply: 3mA Input Impedance: 390kOhm Measurement Error: 0.1% Voltage - I/O High: 2.4V Voltage - I/O Low: 0.8V
- Operating Temperature: -40 to 85 C
- Output Options: Inverting
- Package Type: DIP
- Supply Voltage (Vi): 4.75 to 5.25 volts
-
Supplier: Win Source Electronics
Description: Win Source Part Number: 1315386-90E32ERGI8 Category: Integrated Circuits (ICs)>PMIC - Energy Metering Package: Tape & Reel (TR) Mounting: SMD (SMT) Current - Supply: 25mA Input Impedance: 50kOhm, 80kOhm, 120kOhm Measurement Error: 0.5% Voltage - I/O High: 2.8V
- Operating Temperature: -40 to 85 C
- Output Options: Inverting
- Supply Voltage (Vi): 2.8 to 3.6 volts
Find Suppliers by Category Top
Featured Products Top
-
sensitivity respectively, as a function of VSWR magnitude and phase. AMTS is designed to run under Microsoft® Windows™ 2000 and Windows™ XP. Mobile Phone TX/RX Load Pull Load pull consists of varying (pulling) the load impedance seen by a device-under-test (in (read more)
Browse Dimensional Gages and Instruments Datasheets for Maury Microwave -
. Additionally, data storage is available using the device’s internal memory, which can store up to 16,000 readings. The meter can operate up to 65 hours on a single battery charge and it can work off the battery charger when permanently mounted. There are four accessory options (read more)
Browse Torque Sensors Datasheets for Transducer Techniques, LLC -
transmission. The application of a U.S. military-grade surface treatment process combined with super-hard gold plating ensures that the contact interface remains virtually oxide-free and maintains consistent low impedance. This is critical for applications involving: (read more)
Browse Slip Rings Datasheets for JiuJiang Ingiant Technology Co., Ltd.
Conduct Research Top
-
Impedance Battery Testing According to a Manufacturer of Test Devices
Internal battery ohmic measurements have been a hot topic amongst battery users and battery manufacturers for the last ten or twelve years. Everyone seems to agree that measuring the internal parameters of a cell can be very useful in determining a battery's state of health. These measurements
-
Benefits of Conductance Battery Testing
Conductance is a measurement of the plate surfaces available for chemical reaction. High relative conductance is a reliable indication of a healthy battery.Conductance declines as the battery fails. Conductance: Applying an AC voltage of a known frequency and amplitude across the cell/unit
-
A Day in the Life of a Battery in New York City
Are you monitoring your battery impedance based on initial or average measurements? If your answer is the latter, you may be putting your battery performance at risk when it's needed the most - during a power failure. This presentation explores a case where a company was using average impedance
-
Ohmic Measurements: The History and the Facts (.pdf)
Internal battery ohmic measurements are a hot topic among battery users. Measuring the internal parameters of a cell is very useful in determining a battery's state of health. But what is the difference in the various measurement methods used? Internal resistance of a cell is the most important
-
Developing An Advanced, Predictive Battery Health Monitoring Solution With A Low-cost Microcontroller Solution
becoming ever more important, but this is completely addressable with off the shelf microprocessor technology and software. In this paper, we will explore two different types of failure and lifespan prediction in battery systems: 1) Electrochemical Impedance Spectroscopy (EIS) and 2) Resistive
More Information Top
-
On Condition Maintenance Based on the Impedance Measurement for Traction Batteries: Development and Industrial Implementation
Experimental information for five modules in different conditions with the same commercial model of the battery ( impedance measured to 50 Hz).
-
A novel online measurement technique for AC impedance of batteries and other electrochemical systems
However, the voltage drop is not measured and this is the key to this circuit for battery impedance measurements .
-
Measurements of Electric Performance and Impedance of a 75 Ah NMC Lithium Battery Module - DTU Orbit
Charge-discharge curves,
temperature and battery impedance measurements can provide information about these aspects. -
Determinants of Dual Chamber Pulse Generators Longevity
The aim of tbis study was to investigate the effect of battery capacity, internal current drain, and stimulation energy on pulse generators longevity, and if battery impedance measurements can reliably predict pulse generators end‐of‐life.
-
Internal Resistance: Harbinger of Capacity Loss in Starved Electrolyte Sealed Lead Acid Batteries
Battery impedance measurements were made with a Keithley Model #503 A.C. resistance bridge at 40 Hz frequency.
-
Internal impedance of battery detection based on theory of chaotic Oscillator
[4] Liu Baifen, Cheng Hailin, “Development and implementation of new method of battery impedance measurement ”, Instrument technique and sensor, No.5, pp. 49-50.
-
A Comparison of Different Methods for Battery and Supercapacitor Modeling
Dependent on the amount of depression of the semi-circles more RC-circuits are taken to approximate the battery impedance measurements .
-
Parameter Identification and Analysis of Uncertainties in Measurements of Lead–Acid Batteries
Several studies have been proposed for the assessment of the battery SOC or SOH by internal battery impedance measurements [1]–[5].
-
Estimation of the lead-acid battery initial state of charge with experimental validation
This paper presents a novel method for the estimation of the lead-acid battery initial state of charge (SOC) using the battery impedance measurement .
-
Analysis of the propagated uncertainty in a identification algorithm applied to a Lead-Acid battery
Internal battery impedance measurement has been proposed as a technique for assessment of the battery SOC or SOH [1], [2], [3], [4], [5].