Products/Services for Cooling Tower Backflow Preventers
-
Backflow Preventers - (127 companies)Backflow preventers are assemblies with two check valves and two shut-off valves that prevent reverses in process flow. They may also include test cocks for each chamber within the assembly. Backflow preventers have a variety of applications... -
Cooling Towers - (234 companies)Cooling towers are defined as any open water recirculation device that uses fans or natural draft to draw or force air to contact and cool water by evaporation. How to Select Cooling Towers. Image Credit: DME Company, Baltimore Aircoil Company... -
Fans and Blowers (industrial) - (1537 companies)Positive displacement (or rotary lobe) fans consist of multiple co-rotating, serpentine shafts that mesh to move air and gases in a controlled manner. The shafts mesh so tightly that backflow is prevented. Typically, bi-lobal fans and tri-lobal are used... -
Tower Packing - (42 companies)Tower packing and tower fill materials are used in cooling towers to provide a high surface area for steam condensation without restricting air flow. Tower packing is a mass of inert, solid shapes. Within a cylindrical column, it provides a greater... -
Industrial Valves - (3054 companies)...flow in the oppose direction forces the valve closed. These valves are important for preventing backflow to systems in applications such as wastewater management. Video Credit: cteskills.com / CC BY-SS 4.0. Method of Control. The mechanism to control... -
Electronic Cooling Fans - (613 companies)Electronic cooling fans move air to cool electronic devices. Description. Electronic cooling fans move air to cool electronic devices such as computers and appliances. They are also used in telecommunications, military, and general industrial...
-
Communication Tower Erection Services - (71 companies)...the tower in which personnel may be exposed to excessive levels of RF radiation. Tower painting can prevent corrosion and improve a tower 's appearance. Types. Communication tower erection services build many different types of towers. Concealed towers...
-
Blowout Preventers - (37 companies)Blowout preventers (BOPs) are specialized valve assemblies that prevent uncontrolled flow of formation fluid during well drilling operations. Several assemblies are typically stacked to create a fail-safe mechanism. Blowout preventers (BOPs...
-
Towers, Masts, and Poles - (273 companies)Towers, masts and poles elevate, support and/or position personnel and equipment such as antennas, lighting, surveillance cameras or sensors, wind turbines, weather instruments, and power lines. Towers, masts, and poles are used to provide elevation...
-
Dampers and Louvers - (300 companies)...are also made of galvanized steel, but are designed for use on the discharge side of an axial flow fan. These dampers prevent fan shutdown and can withstand pressures and velocities in multi-fan applications. Louver Types. There are four basic types...
Product News
-
Vooner FloGard LLC
COOLING TOWERS WITH GRAVITY STRAINER COOLING TOWERS WITH GRAVITY STRAINER. Warmer ambient temperatures can cause your vacuum pump seal water temperature to rise significantly in recirculating systems producing a loss of pump capacity. These temperatures can reach as high as 125 oF in many applications. Adding a cooling tower can bring the seal water temperature down to 80-90 oF and improve vacuum pump performance by approximately 10-15%. A self-cleaning gravity strainer can be located ahead of the cooling tower to remove debris... (read more)Browse Vacuum Pumps and Vacuum Generators Datasheets for Vooner FloGard LLC -
DeZURIK, Inc.
CheckMate UltraFlex® for Backflow Prevention sewer overflow (CSO) prevention, sanitary sewer overflow (SSO) mitigation, and flood control. It stands as an outstanding valve for preventing unwanted backflow, averting risks of surcharging and flooding. Click on the CheckMate UltraFlex (R) video for easy viewing and sharing. (read more)Browse Check Valves Datasheets for DeZURIK, Inc. -
O'Keefe Controls Co.
One Device-Unidirectional Metered Flow/No backflow O'Keefe Controls Co. Tamperproof Checked Orifices are a unique style of flow control consisting of an integral check valve and a fixed precision orifice incorporated into a single fitting. This efficient construction allows metered flow in one direction and no flow in the opposite direction -- ideal for flow control applications such as isolation of fluid sources in mixers, fluid contamination reduction, and preventing backflow in metered systems, to name just a few of the many uses across... (read more)Browse Flow Orifices and Flow Restrictors Datasheets for O'Keefe Controls Co. -
Branch Environmental Solutions
Scrubbing Towers Explained (BE) Packed Towers. Packed Towers are used for gas absorption including acid gases such as S02, HCl and others. Packed Towers can also absorb solvents such as Alcohol and gases such as Ammonia. Almost any water soluble chemical can be removed from the gas using a Packed Tower. Packed Towers can also be used to remove trace quantities such as removing odors including Hydrogen Sulfide. This type of scrubber can also be used for cooling gas, aeration and any other application where transferring from... (read more)Browse Scrubbers Datasheets for Branch Environmental Solutions -
DeZURIK, Inc.
Tideflex® Check Valves for Backflow Prevention Introducing the Tideflex (R) Duckbill Check Valve - the gold standard in backflow prevention. With an unrivaled reputation, Tideflex (R) Duckbill Check Valves boast a low cracking pressure, effectively eliminating standing water while maintaining minimal head loss. Constructed entirely from elastomer, they're impervious to warping or freezing, and corrosion is a thing of the past. What sets Tideflex (R) Duckbill Check Valves apart is their self-operating design, relying solely on line pressure... (read more)Browse Check Valves Datasheets for DeZURIK, Inc. -
International Society of Automation (ISA)
Preventing Climate and Other Disasters Controlling the Future - Controlling Nonindustrial Processes: Preventing Climate and Other Disasters. Many books have been published about stopping global warming. What sets this book apart is that it applies the science of process control to analyze the warming process. To control a process, we must fully understand it. Global warming is analyzed here as a heat balance process in which Earth is warmed by the Sun and cooled by outer space. For a million years these heat flows were in balance... (read more)Browse Technical Books Datasheets for International Society of Automation (ISA) -
LAND
Prevent Battery Fires Protect Your People, Protect Your Profits, Prevent Battery Fires. The burgeoning adoption of lithium-ion batteries across industries has ushered in a new era of energy efficiency. However, this technological advancement comes with a significant caveat: the heightened risk of thermal runaway and subsequent fires. At AMETEK Land, we're committed to safeguarding lives and assets by offering cutting-edge solutions to mitigate these dangers. Our latest innovation, the LWIR-640 smart radiometric... (read more) -
Indelac Controls, Inc.
Preventing Condensation in Electric Actuators 3 Easy Steps to Prevent Condensation in Electric Actuators. Unwanted condensation in/on electrical goods can have severe consequences. Metal parts, even stored in warehouses can corrode or suffer surface damage as a result of condensation. Inside an actuator enclosure it can damage critical components that impair product quality or productivity of the equipment, possibly leading to a breakdown. How can such a potential problem be solved?. What 's causing condensation in electric actuators... (read more)Browse Electric Rotary Actuators Datasheets for Indelac Controls, Inc. -
Plast-O-Matic Valves, Inc.
PREVENT FUGITIVE EMISSION LEAKS SERIES EASMT/EASYMT PTFE BELLOWS SOLENOID VALVE PREVENTS FUGITIVE EMISSION LEAKS ONE VALVE HANDLES ALL TYPE SOLUTIONS!. Direct Acting, Normally-Closed PTFE Bellows Seal Solenoid Valves Series EASMT/EASYMT. True Blue (R) Solenoid Valves Series EASMT & EASYMT for pressure, drain, and vacuum service; designed for all types of aggressive chemicals, salt solutions, acids, caustics, and ultrapure liquids such as deionized water. *NOW INCLUDES W24 Fully Rectified Coil with Z-Cool DIN * Uses 75% Less... (read more)Browse Solenoid Valves Datasheets for Plast-O-Matic Valves, Inc. -
DFT Inc.
Quiet Protection for Critical Cooling high-efficiency cooling loops. Unlike traditional swing or dual-plate check valves, the ALC 's axial flow spring-assisted design closes smoothly and quickly to prevent slam and water hammer, protecting pumps and piping while extending system and valve service life. Key Benefits. Low Pressure Drop - Efficient flow for reduced energy demand. Non-Slam, Silent Operation - Prevents water hammer and protects critical equipment. Compact, Lightweight Design - Ideal for space-constrained installations... (read more)Browse Check Valves Datasheets for DFT Inc.
-
Power Burst Facility/Boron Neutron Capture Therapy Program for cancer treatment
A work authorizationwas releasedto have EG&G Engineeringestablishthe requirementsand design for installationof backflow preventers in the potable water system at the reactor, installation of additional fire protectionsprinklersystems on the cooling tower stairs and installation of a fire protection system tie-in at the…
-
MSRE DESIGN AND OPERATIONS REPORT. PART I. DESCRIPTION OF REACTOR DESIGN
A backflow preventer i n this line, BFP-819, is located in the w e s t side of the liquid waste cell, and prevents contamination of the cooling tower water system by reverse flow.
-
CHEMICAL ASPECTS OF MSRE OPERATIONS.
After passing through a backflow preventer , the water is used in the liquid waste system, in the vapor-condensing system, for general cleanup of equipment, as makeup for the coohng tower water system, and for cooling of the charcoal beds.
-
Non-storm water discharges technical report
2.2.6 Cooling Tower Maintenance Discharges ........................................12 3.0 Potable Water System ..................................................................................15 3.1 Drinking Water Tanks .............................................................................15 … Piping............................................................................................15 3.3 New Water System Pipes and Broken Line Replacement ......................16 3.4 Backflow Preventers ...............................................................................16 3.5 Well…
-
THE OAK RIDGE RESEARCH REACTOR: A FUNCTIONAL DESCRIPTION.
It also supplies drinking water, plumbing needs, secondary-coolant system makeup, and the cooling requirements of miscellaneous equipment at the ORR Supply water to the … various experiment requirements is fed from the potable-water system through backflow preventers Because of these separations … secondary- coolant makeup is earned in d 6 in line to the cooling tower basin, where it…
-
Oak Ridge Reservation Annual Site Environmental Report for 2009
…water usage, and significant progress was made on a Potable Water Upgrade Project (FY 2010 project completion) to replace piping that is over 60 years old to eliminate potential underground piping leaks and resolve low system pressure and backflow preventer isolation issues. .... A total of 21 meters have been installed at 8 building and cooling tower locations, and 16 of these meters were connected to the Utilities Management System for performance monitoring and automated baseline metering data collection and report generation.
-
States > New Jersey > State > Statutes > Title 45 - Professions and Occupations > 16A - Heating‚ Ventilating‚ Air Conditioning and Refrigeration Co...
warm air heating or refrigeration and evaporative cooling systems, ventilation and exhaust systems, dust collectors, air handling equipment, heating or cooling coils, air or refrigerant compressors, chillers, cooling towers , evaporators, condensers, plenums, fans, blowers, air cleaners, mechanical ventilation for radon mitigation, humidifiers .... natural or manufactured gas piping on the load side of a meter; supply water piping to equipment being served from an existing dedicated source connected downstream from an approved backflow preventer , except in replacement cases, the installation of the required approved backflow…
-
States > Louisiana > State > Proposed Regulations > 2015 Documents > December 20‚ 2015 > LAC 17:I.Chapter 1 - Declaration of Emergency - Uniform Construc...
The type of backflow preventer shall be selected based upon the application in accordance with Table 608.1. .... Add Section 608.16.11, Cooling towers .
-
States > Louisiana > State > Register > 2015 > 12/20/2015
The type of backflow preventer shall be selected based upon the application in accordance with Table 608.1. .... Add Section 608.16.11, Cooling towers . a.
-
States > Florida > Miami-Dade County > Regulations > Part 3 > [FL MDade Reg 3-32] 32 - Water and Sewer Regulations
…limited to: polluted used waters; polluted auxiliary water; all types of process waters; chemicals in fluid form, including pesticides and fertilizers; fuels and oils; acids and alkalies; circulated cooling waters connected to an open cooling tower and/or cooling waters that are chemically .... Fixture isolation means installing an approved backflow preventer at the source of the potential contamination.
Indicates content that may require registration and/or purchase.