Supplier: Munters DH
Description: dew point in the space at a very low operating cost. In addition, the FreeDry™ system provides lower leaving temperature in the summer to minimize the load on the ice sheet. The system can be sized to handle the outdoor air requirement of the facility and can provide modulating
- Air Volume: 8,000 SCFM
- Removal Technique: Air Cooled DX, Solid Desiccant Rotor
- Features: Integral Cooling, Other
-
Supplier: Ebac Industrial Products, Inc.
Description: The system has been designed to be transported and operated in adverse conditions. The moisture collecting apparatus is self-cleaning, however, an optional air filter can be used in heavily dust contaminated areas. The system requires exceptionally low levels of maintenance.
-
Supplier: Munters DH
Description: Outside air often represents the greatest moisture load to a building. That is why experts agree pre-teating makeup air with a dedicated outside air system (DOAS) is the most efficient and effective approach at managing it. Munters' award winning DryCool™ Standard
- Air Volume: 2,000 to 16,000 SCFM
- Features: Control Sensor, Integral Control Panel, Integral Cooling, Microprocessor Control, NEMA Rated, Other, Process Air Filter, UL Listed, Variable Blower Configuration, Weather Tight
- Desiccant Reactivation: Electric, Gas Fired
- Removal Technique: Solid Desiccant Rotor
-
-
Supplier: Bry-Air, Inc.
Description: optimize the performance of the dehumidifier as moisture loads decrease from peak load design. Included in the retrofit package: Hardware (PLC, HMI, rotor motor /VFD, controls Software (EcoDry Lite software) Bry-Air will install the EcoDry control software into the PLC. Design visit
-
Supplier: Aggreko
Description: 160 cfm Dehumidifiers High humidity levels can be rough on your business, causing condensation and corrosion to your critical operations. When critical processes are threatened due to power or temperature interruptions, trust Aggreko experts to help you recover quickly. Features Desiccant
- Air Volume: 160 SCFM
- Removal Technique: Air Cooled DX
- Desiccant Reactivation: Electric
- Features: Portable
-
Supplier: Ebac Industrial Products, Inc.
Description: defrosting systems. Standard 115v power requirement for operations in any location Lightweight Condensate Pump (20' vertical lift, 100' + horizontal) Air Filter
-
Supplier: HVACQuick.com
Description: Fantech commercial DEHUMIDIFIER. 300 CFM with Low Grain Refrigeration. 115V, 11.3 Amps. 190 pint capacity at saturation. Models LPD150LR and LPD190LR: Low grain refrigerant system removes more moisture from the air than standard refrigerant systems. Models LPD180CR and
-
Supplier: Terra Universal, Inc.
Description: Extends shelf life of pharmaceuticals, semiconductor components, food products, and other sensitive materials Provides the humidity stability required by FDA and other regulating agencies Regenerating silica gel desiccant system produces dry air flow between 50 and 300 CFM (85
- Air Volume: 300 SCFM
- Moisture Removal: 1.8 to 6.6000000000000005 lbs/hr
- Relative Humidity: 10 to 50 %
- Desiccant Reactivation: Electric, Positive Temperature Coefficient (PTC) Heater
-
Supplier: Ebac Industrial Products, Inc.
Description: external 18" fans, dehumidification system, heating element, master controller and optional vent system. A rugged, professional drying system, this unit provides the reliability you expect and the flexibility you need to efficiently dry all wood species. Drawing upon over
-
Supplier: DACO Instrument Company
Description: DACO desiccators are small, efficient air drying and breathing devices designed for attachment to airborne instruments. Moisture condensation as a result of temperature and air pressure changes during flight. Moisture can cause optical instruments to fog and electrical systems
- Removal Technique: Solid Desiccant Rotor
-
Supplier: InspectorTools
Description: accurate RH and temperature measurements of air conditioning systems, dehumidifiers, ambient air samples, wall cavities and more. Results are displayed on a large LCD with 0.1 resolution. Features include a HUMICAP® Sensor (insensitive to most chemical contaminants), HOLD
Find Suppliers by Category Top
More Information Top
-
MODELING DIMENSIONAL SHRINKAGE OF SHAPED FOODS IN FLUIDIZED BED DRYING
The fluidized bed dryer obtained the drying air through the heat pump dehumidifier system .
-
Seed Conditioning, Volume 2: Technology-Parts A & B
A ducting system to carry dry air from the dehumidifier to the seed chamber, flow the air through the seed mass, and then return the “moist” air to the dehumidifier for re-drying.
-
Residential Dehumidification Systems Research for Hot-Humid Climates: September 1, 2001 -- December 30, 2003
Schematic of stand-alone dehumidifier in hall closet system ; dry air is mixed throughout the house via central fan cycling that is part of the standard Building America central-fan-integrated supply ventilation system; note the small supply and return air flow…
-
Mass and Volume efficient CO2 Removal and O2 Generation System
Therefore, the dry air , which is obtained by the dehumidifier system , was introduced directly to the KO2 cartridge.
-
Modern Plastics Handbook > Auxiliary Equipment
The typical dehumidifying drying system consists of the process air fan, dehumidifier , an electric or gas-fired air heating system, a control system, the drying hopper, and a process air filter.
-
Evaluation of West Valley High-Level Waste Tank Lay-Up Strategies
The drying system would include a dehumidifier and heater for air forced into the vaults.
-
West Valley High-Level Waste Tank Lay-Up Strategies
The drying system would include a dehumidifier and heater for air forced into the vaults.
-
Final Report West Valley High-Level Waste Tank Lay-Up
The drying system would include a dehumidifier and heater for air forced into the vaults.
-
Decision Plan for West Valley High-Level Waste Tank Lay-Up
The drying system would include a dehumidifier and heater for air forced into the vaults.
-
The Experiment and Simulation of Solid Desiccant
Dehumidification for Air-Conditioning System in a
Tropical Humid Climate
In the desiccant cooling system , the dry air which passed through the dehumidifier was passed into the air-conditioning system by forced ventilation.
Indicates content that may require registration and/or purchase.