Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: Online biogas analyzer Gasboard-3200 is a rack type analyzer, mainly used for measuring biogas compositions of CH4, CO2, O2, H2S with high accuracy, stable performance, can be easily integrated with biogas analysis system, widely used in anaerobic digestion biogas, waste water
- Analyzer Technology: Electrochemical, Infrared
- Application: Process Gas
- Display: Digital
- Electrical Outputs: Analog Current, Switch
-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: Online syngas analyzer Gasboard-3100 is a stationary analyzer with standard 19'' 3U rack enclosure, easy to be integrated inside industrial system. It is able to online continuously measure volume concentration of CO, CO2, CH4, H2 , O2 , CnHm, C2H2 , C2H4 simultaneously, and calculate
- Analyzer Technology: Electrochemical, Infrared
- Application: Process Gas
- Display: Digital
- Electrical Outputs: Analog Current, Switch
-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: Online NDIR flue gas analyzer adopts micro-flow infrared sensor to measure continuously simultaneously concentration of CO, CO2, SO2, NO, O2 with CE certification, it has RS-232 and 4-20mA output, smart operation and various functions. Widely used in pollution emission monitoring in
- Analyzer Technology: Electrochemical, Infrared, Other
- Application: Continuous Emissions Monitoring
- Display: Digital
- Electrical Outputs: Analog Current, Switch
-
-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: Portable natural gas analyzer Gasboard-3110P is a portable type analyzer and the best alternative of GC and MS that can be used for online measurement for natural gas composition and heating value second by second. It is widely used in various applications such as natural gas, coal bed
- Analyzer Technology: Infrared
- Application: Process Gas
- Display: Digital
- Electrical Outputs: Switch
-
Supplier: LECO Corporation
Description: Superior nitrogen/oxygen determination is delivered by LECO’s TC500 Series. It offers quality, high-performance, and advanced technology that meet virtually any production needs for in metals, refractories, and other inorganic materials. Improved solid-state infrared (IR) and
- Analysis Method / Detection Technology: Inert Gas Fusion (IGF), Infrared Detector (IR Cell), Thermal Conductivity Detector
- Elements Analyzed: Nitrogen (N) / Protein, Oxygen (O)
- Test Media: Inorganic Material
-
Supplier: LECO Corporation
Description: The ON736 Oxygen/Nitrogen Elemental Analyzer is designed for wide-range measurement of oxygen and nitrogen content of inorganic materials, ferrous and nonferrous alloys, and refractory materials using the inert gas fusion technique. The instrument features a custom MS
- Analysis Method / Detection Technology: Inert Gas Fusion (IGF), Infrared Detector (IR Cell), Thermal Conductivity Detector
- Elements Analyzed: Nitrogen (N) / Protein, Oxygen (O)
- Test Media: Ferrous Metal (Steel, Cast Iron), Inorganic Material, Nonferrous (Copper, Aluminum)
-
Supplier: LECO Corporation
Description: The ONH836 Oxygen/Nitrogen/Hydr ogen Elemental Analyzer is designed for wide-range measurement of oxygen, nitrogen, and hydrogen content of inorganic materials, ferrous and nonferrous alloys, and refractory materials using the inert gas fusion technique. The instrument features
- Analysis Method / Detection Technology: Inert Gas Fusion (IGF), Infrared Detector (IR Cell), Thermal Conductivity Detector
- Elements Analyzed: Hydrogen (H), Nitrogen (N) / Protein, Oxygen (O)
- Test Media: Ferrous Metal (Steel, Cast Iron), Inorganic Material, Nonferrous (Copper, Aluminum)
-
Supplier: LECO Corporation
Description: Get fast and simultaneous measurement of nitrogen and oxygen to 1 ppm with the TC400. Using the inert gas fusion principle, it handles a wide variety of metals, refractories, and inorganic materials, and is upgradeable from single-to dual-element detection. The TC400 provides reliability and
- Analysis Method / Detection Technology: Carrier Gas Hot Extraction (HE), Inert Gas Fusion (IGF), Infrared Detector (IR Cell), Thermal Conductivity Detector
- Elements Analyzed: Nitrogen (N) / Protein, Oxygen (O)
- Test Media: Inorganic Material
-
Supplier: Emerson Automation Solutions – Rosemount
Description: configuration, operation and diagnostics with an easy-to-use hand-held Infrared Remote Control (IRC). Only one IRC is required to communicate with any number of Model 5081FG Two-Wire In Situ Oxygen Analyzers at the user’s location. Communication with any specific Model 5081FG
- Analyzer Technology: Other
- Application: Process Gas
- Display: Digital
- Electrical Outputs: Analog Current
-
Supplier: Control Instruments Corp.
Description: proven industrial platform Complete Stand-Alone Analyzer with built-in alarms & relays Multiple wavelengths detect broad range of solvents & gases without recalibration Response factors with minimum variation Superior Response Time; Less than 4 Seconds No add-ons, accessories, moving parts,
- Analyzer Technology: Infrared
- Application: Ambient Air Monitoring, Process Gas
- Display: Digital
- Electrical Outputs: Analog Current, Switch
-
Supplier: Fuji Electric Corp. of America
Description: Measurement of the concentration of 1 to 5 components The Fuji Electric extractive multigas analyser range consists of non-dispersive 5-gas infrared analyzers. They allow simultaneous and continuous measurement by extraction of 1 to 5 gases from: CO, CO2, NOx, SO2, CH4 and N2O by
- Application: Process Gas
- Display: Digital
- Electrical Outputs: Analog Current
- Features: Audible or Visual Alarms, Self Calibration
-
Supplier: Fuji Electric Corp. of America
Description: Optimization of combustion efficiency and compliance with environmental standards. Ideal for combustion control in boilers, incinerators, and furnaces. Lowering CO2, SOx, and NOx emissions while saving energy. This oxygen analyzer is used to continuously measure oxygen
- Application: Confined Space Monitoring
- Display: Digital
- Electrical Outputs: Analog Current
- Instrument Type: Analyzer
-
Supplier: Fuji Electric Corp. of America
Description: Optimization of combustion efficiency and compliance with environmental standards. Ideal for combustion control in boilers, incinerators, and furnaces. Lowering CO2, SOx, and NOx emissions while saving energy. This oxygen analyzer is used to continuously measure oxygen
- Analyzer Technology: Infrared
- Application: Confined Space Monitoring
- Display: Digital
- Electrical Outputs: Analog Current
-
Supplier: Fuji Electric Corp. of America
Description: Measurement of the concentration of 1 to 5 components The Fuji Electric extractive multigas analyser range consists of non-dispersive 5-gas infrared analyzers. They allow simultaneous and continuous measurement by extraction of 1 to 5 gases from: CO, CO2, NOx, SO2, CH4 and N2O by
- Display: Digital
- Electrical Outputs: Analog Current
- Instrument Type: Analyzer
- Mounting Type: Fixed
-
Supplier: Siemens Analytical Products
Description: by modern electronics, ease of operation and a physical element that is adapted to the measuring task. Up to two infrared active components and oxygen can be measured in a single analyzer. The use of optical couplers and optical filters in the IR physics increases the
-
Supplier: Process Sensing Technologies USA
Description: The MoGas Medical gas analyzer range is a wall or surface mounting instrument designed for use on Medical Oxygen Generation systems for checking the purity of the Oxygen produced. The MO2GA93 range is specifically designed for Medical Oxygen Generation systems producing
- Features: Self Calibration
- Instrument Type: Analyzer
- Measurement Type: %Volume, Trace
- Operating Humidity: 15 to 95 %
-
Supplier: ABB Measurement & Analytics
Description: ionization (FID) technology and oxygen measurement. The high resolution FTIR spectrometer provides selective measurement of infrared active gas molecules with high sensitivity and stability. The multi-component analyzer system ACF5000 offers: Simultaneous measurement of up to 15
- Application: Continuous Emissions Monitoring, Process Gas
- Display: Digital
- Measurement Type: %Volume, Trace
- Mounting Type: Fixed
-
Supplier: Nova Analytical Systems Inc.
Description: The Model 309 Series Portable CO2 and O2 Analyzer is a rugged, fast-responding, and accurate instrument for conveniently monitoring the atmosphere in a fruit storage C/A room. The standard range of the analyzer is 0-10% CO2 and 0-25% O2. Other ranges are available. The Model 309 series
- Application: Ambient Air Monitoring, Process Gas
- Display: Digital
- Electrical Outputs: Analog Current, Analog Voltage
- Features: Audible or Visual Alarms, Data Logger, Sampling Pump
-
Supplier: Nova Analytical Systems Inc.
Description: The Model 309 Series Portable CO2 and O2 Analyzer is a rugged, fast-responding, and accurate instrument for conveniently monitoring the atmosphere in a fruit storage C/A room. The standard range of the analyzer is 0-10% CO2 and 0-25% O2. Other ranges are available. The Model 309 series
- Application: Ambient Air Monitoring, Process Gas
- Display: Digital
- Electrical Outputs: Analog Current, Analog Voltage
- Features: Audible or Visual Alarms, Data Logger, Hazardous Environments, Sampling Pump
-
Supplier: Nova Analytical Systems Inc.
Description: The Nova 900 Series analyzers have been designed for monitoring recovered and processed gases from landfill and biogas sites. This equipment continuously removes moisture from the wet sample gas without the need for cooling water, compressed air, or failure-prone thermoelectric elements. The
- Analyzer Technology: Electrochemical, Infrared
- Application: Process Gas
- Display: Digital
- Electrical Outputs: Analog Current
-
Supplier: Siemens Process Instrumentation
Description: ULTRAMAT/OXYMAT 6 | for IR-active components and oxygen Best combination for IR-active components and oxygen The ULTRAMAT/OXYMAT 6 combines the features of the ULTRAMAT 6 and the OXYMAT 6 in one 19" analyzer. Most frequently used for demanding applications, the ULTRAMAT
- Application: Continuous Emissions Monitoring, Process Gas
- Display: Digital
- Electrical Outputs: Analog Current
- General Gas Types: Toxic Gas, Combustible Gas
-
Supplier: Emerson Automation Solutions – Rosemount
Description: Rosemount Analytical’s MLT, CLD and FID series of analyzers offer MLT with multi-component, multi-method analysis utilizing non-dispersive infrared, visible, ultraviolet (NDIR/UV/VIS), thermal conductivity (TCD), paramagnetic, and electrochemical sensor technologies
- Analyzer Technology: Electrochemical, Infrared, Photoionization Detector, Other
- Application: Process Gas
- Display: Digital
- Electrical Outputs: Analog Current, Analog Voltage
-
Supplier: Emerson Automation Solutions – Rosemount
Description: This multi-component QCL represents the next generation of gas analyzers and sensors, with the ability to measure up to 20 gases and an interchangeable modular configuration for up to 9 lasers. An embedded ARM processor gives fully autonomous intelligent operation. Key Features
- Analyzer Technology: Infrared
- Application: Process Gas
- Display: Digital
- Electrical Outputs: Analog Current
-
Supplier: Nova Analytical Systems Inc.
Description: The 7460 Series Portable Analyzers are available in six versions for the simultaneous measurement of the gases typically found in the exhaust from internal combustion engines. CO, CO2, and HC's are detected by a dual-wavelength infrared detector. O2 and NOx (as NO) are detected by
- Analyzer Technology: Electrochemical, Infrared
- Application: Continuous Emissions Monitoring
- Display: Digital
- Electrical Outputs: Analog Current, Analog Voltage
-
Supplier: Emerson Automation Solutions – Rosemount
Description: Rosemount Analytical’s MLT, CLD and FID series of analyzers offer MLT with multi-component, multi-method analysis utilizing non-dispersive infrared, visible, ultraviolet (NDIR/UV/VIS), thermal conductivity (TCD), paramagnetic, and electrochemical sensor technologies
- Analyzer Technology: Electrochemical, Infrared, Photoionization Detector, Other
- Application: Process Gas
- Display: Digital
- Electrical Outputs: Analog Current, Analog Voltage
-
Supplier: ABB Measurement & Analytics
Description: Line offers: Proven analyzer technology Intuitiv operation via five buttons UV photometer Infrared photometer Paramagnetic oxygen analyzer Electrochemical oxygen sensor Thermal conductivity analyzer Trace oxygen analyzer
- Electrical Outputs: Analog Voltage
- Instrument Type: Monitor, Analyzer
- Measurement Type: %Volume, Trace
- Mounting Type: Fixed
-
Supplier: ABB Measurement & Analytics
Description: Paramagnetic oxygen analyzers Magnos206, Magnos28 Thermal conductivity analyzers Caldos27, Caldos25 Easy to Combine An oxygen as well as the thermal conductivity analyzer can be combined with the Infrared Photometer. This means that complex measuring tasks
- Electrical Outputs: Analog Voltage
- Features: Interchangeable Probes
- Instrument Type: Monitor, Analyzer
- Measurement Type: %Volume, Trace
-
Description: The LumaSense Technologies' ANDROS 6500 series offers unparalleled accuracy and performance through simplicity of design and implementation. Unlike analyzers that require moving components, the 6500 series uses a pulsed infrared source to achieve high accuracy with high reliability
- Application: Process Gas
- General Gas Types: Combustible Gas
- Instrument Type: Monitor
- Measurement Type: %Volume, Trace
-
Supplier: COSA Xentaur Corporation
Description: The ZSS is a Highly Efficient Ammonia (NH3), Hydrochloric Acid (HCl), Moisture, Oxygen (O2), Carbon Monoxide (CO), Carbon Dioxide (CO2) and Methane (CH4) Optical Gas Analyzer For Stack Gas Applications. COSA ZSS The ZSS uses a non-dispersive infrared absorbance system
- Application: Continuous Emissions Monitoring
- Electrical Outputs: Analog Current, Analog Voltage
- Instrument Type: Analyzer
- Measurement Type: Trace
-
Supplier: InspectorTools
Description: Air, Carbon Dioxide (CO2), and Oxygen (O2) Reference Values. Included with each unit: PCA®3 Combustion Analyzer 12" probe and hose assembly Factory calibrated and installed sensors Protective Boot w/Magnet Hard carrying case
-
Supplier: InspectorTools
Description: Air, Carbon Dioxide (CO2), and Oxygen (O2) Reference Values. Included with each unit: PCA®3 Combustion Analyzer 12" probe and hose assembly Factory calibrated and installed sensors Protective Boot w/Magnet Hard carrying case
-
Supplier: RS Components, Ltd.
Description: -up. Infra-red output to the thermal paper printer. Torch light. Connection for optional gas leak detector. Designed to meet BS7927, EN 50379 and BS7967. Battery life typically 12+ hours from full charge Gases Detected = Carbon Dioxide, Carbon Monoxide, Carbon Monoxide/Carbon Dioxide Ratio
-
Supplier: RS Components, Ltd.
Description: / Î?T. Hold, store and auto-store readings. Reports include combustion test, tightness test, CO build-up and differential temperature. Infra-red output to thermal paper printer. Torch light. Connection for optional gas leak detector. Designed to meet BS7927, EN 50379 and BS7967. Battery life
-
Supplier: Linde North America, Inc.
Description: US EPA Method 25, "Determination of Total Gaseous Nonmethane Organic Emissions as Carbon;" Method 25A, "Determination of Total Gaseous Organic Concentration Using a Flame Ionization Analyzer;" Method 25B, "Determination of Total Gaseous Organic Concentration Using a Nondispersive
- Concentration: 9.99 to 99.99 %
- Hydrocarbons: Other
- Hydrogen, Hydrides and Hydrogen Compounds: Hydrogen
- Nitrogen and Nitrogen Compounds: Nitrogen
-
Description: The Andros 6511 offers unparalleled accuracy and performance. Now taking advantage of the latest technology, Andros brings you a product with superior performance and reliability. The Non-Dispersive InfraRed (NDIR) sensor can measure the greenhouse gases CO2 and Methane via RS
- Application: Process Gas
- General Gas Types: Toxic Gas, Combustible Gas
- Instrument Type: Monitor
- Measurement Type: %Volume, Trace
-
Supplier: CO2Meter.com
Description: OSHA-Compliance Personal Safety Alarm Stadiums Welding See More "Close Cart" Welding Gas Analyzer Sensors & OEM See More "Close Cart" Car & Truck Cabin Air Oxygen
- Features: Controller
- Measurement Type: Trace
- Operating Temperature: -4 to 140 F
-
Supplier: CO2Meter.com
Description: -Compliance Personal Safety Alarm Stadiums Welding See More "Close Cart" Welding Gas Analyzer Sensors & OEM See More "Close Cart" Car & Truck Cabin Air Oxygen Sensor Module
- Features: Controller
- Measurement Type: Trace
- Operating Temperature: -4 to 140 F
-
Supplier: CO2Meter.com
Description: -Compliance Personal Safety Alarm Stadiums Welding See More "Close Cart" Welding Gas Analyzer Sensors & OEM See More "Close Cart" Car & Truck Cabin Air Oxygen Sensor Module
- Features: Controller
- Measurement Type: Trace
- Operating Temperature: -4 to 140 F
Find Suppliers by Category Top
Featured Products Top
-
in some of the most hazardous environments, with high risks of gas leaks, fires, and explosions due to the presence of combustible gases, toxic gases, and oxygen deficiencies. From upstream exploration and production to midstream transportation and downstream refining, ensuring worker safety, asset (read more)
Browse Datasheets for Safeguard Analytics -
wear condition relatively quickly and accurately. For pumps, bearing wear from nonferrous roller components can be detected using elemental spectroscopy. Infrared spectroscopy Infrared Spectroscopy is a great technique for detecting organic contaminants, water and oil (read more)
Browse Oil Sensors and Analyzers Datasheets for AMETEK Spectro Scientific -
Complete oil analysis lab with 4 technologies integrated into a small case – X-Ray Florescence (XRF) spectrometer for elemental analysis – Filter Particle Quantifier (FPQ) pore blockage particle counter – Infrared (IR) spectrometer – Kinematic viscometer (read more)
Browse Oil Sensors and Analyzers Datasheets for AMETEK Spectro Scientific -
the transmission system is using an intercooler. Glycol is a pretty nasty contaminant that can render the oil useless, thus damaging the transmission. Glycol is commonly measured using infrared spectroscopy or elemental spectroscopy. Elemental spectroscopy typically detects the metallo (read more)
Browse Oil Sensors and Analyzers Datasheets for AMETEK Spectro Scientific -
check for those common contaminants, along with tests to determine oil viscosity, and wear metals. Infrared spectroscopy Infrared Spectroscopy is a great technique for detecting organic contaminants, water, and oil degradation products in a used oil sample. One measurement gives a (read more)
Browse Oil Sensors and Analyzers Datasheets for AMETEK Spectro Scientific -
particle count and the general cleanliness level. This is particularly important for hydraulic systems as well as some main engine applications. Laser or direct imaging ties to ISO 4406 or NavAir Codes in those situations. For fluid degradation, look at oxidation by infrared and (read more)
Browse Oil Sensors and Analyzers Datasheets for AMETEK Spectro Scientific -
analysis tools, as it provides information on machine contamination and wear condition relatively quickly and accurately. Its major limitation is that its particle detection efficiency is poor for particles 5 microns in size or larger. Oxidation by Infrared Analysis Oxidation is (read more)
Browse Oil Sensors and Analyzers Datasheets for AMETEK Spectro Scientific -
New analyzer family offers highly accurate and stable measurements for effective chlorine control ChloroStar™ Digital Sensors feature (read more)
Browse Combustion Analyzers Datasheets for ABB Measurement & Analytics -
Accurate air quality measurement is critical for compliance, safety, and performance.
The PCE-PQC 15US delivers high-level particle monitoring in a handheld, lightweight design, making it ideal for cleanrooms, labs, manufacturing, and environmental assessments.The device measures particle sizes up to 75 μm with six parallel measuring channels and offers full reporting acc...
(read more)
Browse Particle Analyzers Datasheets for PCE Instruments / PCE Americas Inc. -
Particle Analyzer The LaserNet 200 Series allows reliability professionals to quickly and easily assess machinery health in just minutes. By testing only a few milliliters of fluid, users see a (read more)
Browse Particle Analyzers Datasheets for AMETEK Spectro Scientific
More Information Top
-
Infrared / Analyzers / Oxygen / Exhaust Test / Endurance
There were no results for " Infrared Analyzers Oxygen Exhaust Test Endurance" .
-
Safety analysis report for the use of hazardous production materials in photovoltaic applications at the National Renewable Energy Laboratory. Volume 2, Append...
Chromatograph Infrared Analyzer Oxygen Analyzer MoistureAnalyzer (gases .
-
METHOD FOR DETERMINATION OF PULMONARY GAS EXCHANGE IN CONNECTION WITH BIRTH
oxygen and infrared analysers for carbon dioxide) would be more advantageous, but the necessary high degree of sensitivity is difficult to obtain with these analysers.
-
Online‐Analysatoren
As OEM module, known infrared analyser with oxygen sensor Uras 14 is used.
-
Sensitivity of infrared water vapor analyzers to oxygen concentration and errors in stomatal conductance
Key words: carbon dioxide, infrared analyzers , oxygen , photosynthesis, stomatal conductance, transpiration, water vapor .
-
Foraging in male bumblebees (Bombus lucorum L.): maximizing energy or minimizing water load?
Oxygen consumptionand respiratory COz production mea- sured simultaneouslywith paramagnetic oxygen analyser and infra- red gas analyser.
-
Selected abstracts of Heat Treating Literature January–August 1984
It was shown that, when using a single component control system, i.e. infrared analyzer or oxygen probe, to control the C potential in the furnace, the controllability of furnace atmosphere de- pends on the completeness of reactions among the constituents and …
-
CHEST Journal | Article
This system consists of a hot-wire flowmeter and oxygen and carbon dioxide analyzer (zirconium element-based oxygen analyzer and infrared carbon dioxide analyzer).
-
Acute oral administration of a tyrosine and phenylalanine-free amino acid mixture reduces exercise capacity in the heat
Expired oxygen and carbon dioxide concentrations were measured from these collections using a combined paramagnetic oxygen analyser and infrared carbon dioxide analyser (Series 4100 Xentra, Servomex, Crowborough, UK), and expired volume was measured using a dry gas meter (Harvard Apparatus Ltd., Edenbridge …
-
Methyl formate oxidation: Speciation data, laminar burning velocities, ignition delay times, and a validated chemical kinetic model
The sampled gas ßow was trans- ferred through heated Teßon lines to a series of an- alytical equipment including a Fourier transform in- frared (FTIR) spectrometer (Nicolet Model 560), an electrochemical oxygen (O2) analyzer ( Infrared Indus- tries Model 2200), and nondispersive carbon …
Indicates content that may require registration and/or purchase.