Supplier: Hach
Description: (No Suggestions); ISENH3181 is a digital, combination gas-sensing ammonia ion selective electrode (ISE) with a replaceable membrane module, refillable outer body, double junction reference and built-in temperature sensor. The Intellical ISENH3181 probe is available with a 1 or 3 meter
- ISE Concentration Range: 0.01 to 14,000 ppm
- ISE Accuracy: 0.05 ±% Full Scale
- Maximum Diameter / Width: 0.047 inch
- Maximum Length: 8.66 inch
-
Supplier: Metrohm USA, Inc.
Description: Shaft material - Glass Temperature range, long-term (°C) - 0 ... 80 Temperature range, short-term (°C) - 0 ... 80 Max. installation length (mm) - 125 SGJ sleeve - Flexible SGJ sleeve Shaft diameter top (mm) - 12 Shaft diameter bottom (mm) - 12 Min. immersion depth (mm) - 1 Electrode plug-in
- Operating Temperature: 32 to 176 F
-
Supplier: Cole-Parmer
Description: for the job. | These fast and accurate electrodes do not require an external reference
they're easier to use than separate sensing and reference half-cell electrodes. | All Cole-Parmer electrodes are double-junction combination ion-selective electrodes and are -
-
Supplier: Cole-Parmer
Description: for the job. | These fast and accurate electrodes do not require an external reference
they're easier to use than separate sensing and reference half-cell electrodes. | All Cole-Parmer electrodes are double-junction combination ion-selective electrodes and are -
Supplier: Cole-Parmer
Description: for the job. | These fast and accurate electrodes do not require an external reference
they're easier to use than separate sensing and reference half-cell electrodes. | All Cole-Parmer electrodes are double-junction combination ion-selective electrodes and are -
Supplier: Cole-Parmer
Description: for the job. | These fast and accurate electrodes do not require an external reference
they're easier to use than separate sensing and reference half-cell electrodes. | All Cole-Parmer electrodes are double-junction combination ion-selective electrodes and are -
Supplier: Hach
Description: Electrode with three ammonia membrane modules, electrode filling solution, and a manual.
- ISE Concentration Range: 0.05 to 17,000 ppm
- Response Time: 180 seconds
- Maximum Diameter / Width: 0.5 inch
- Maximum Length: 5.5 inch
-
Supplier: Hach
Description: Sension+ 9655C is a combination fluoride ion selective electrode (ISE) with an epoxy body, non-refillable, single-junction reference, and non-replaceable crystalline membrane selective to fluoride ions in solution. The 9655C has a BNC connector for laboratory use with the Hach Sensio+
- ISE Concentration Range: 0.01 to 19,000 ppm
- ISE Accuracy: 0.05 ±% Full Scale
- Maximum Diameter / Width: 0.47 inch
- Maximum Length: 4.72 inch
-
Supplier: Hach
Description: Sension+ 9652C is a combination chloride ion selective electrode (ISE) with an epoxy body, non-refillable, double junction reference, and non-replaceable crystalline membrane selective to chloride ions in solution. The 9652C has a fixed 1 meter cable and BNC connector for laboratory
- ISE Concentration Range: 0.1 to 35,500 ppm
- ISE Accuracy: 0.05 ±% Full Scale
- Maximum Diameter / Width: 0.47 inch
- Maximum Length: 4.72 inch
-
Supplier: Accuris
Description: Animal feeding stuffs - Determination of fluoride content after hydrochloric acid treatment by ion-sensitive electrode method (ISE)
-
Supplier: Metrohm USA, Inc.
Description: sleeve - Flexible ground-joint sleeve Shaft diameter top (mm) - 12 Shaft diameter bottom (mm) - 12 Min. immersion depth (mm) - 10 Electrode plug-in head - Metrohm plug-in head Q Indicator electrode type - Polymer (Ca) Membrane material - Polymer Ion - Ca2+ Reference electrolyte type -
- pH Range: 2 to 12 ph
- Operating Temperature: 32 to 104 F
-
Supplier: SWAN Analytical USA, INC.
Description: DescriptionMonitor for continuous measurement of Ammonium, Nitrate or Fluoride in potable water. Complete system mounted on PVC panel:Transmitter AMI ISE Universal in a rugged aluminum enclosure (IP 66).Flow cell M-Flow 10-3PG with temperature sensor (NT5k).Factory tested and calibrated.
- ISE Range: 0.1 to 1,000 ppm
- Display Type: Digital Display
- User Controls: Digital Front Panel
- Form Factor: Panel
-
Description: Ion Selective Electrodes (ISEs) are membrane electrodes that respond selectively to ions in the presence of other ions. These include probes that measure specificions and gasses in solution. The use of Ion Selective Electrodes offers several advantages over other methods
- Maximum Diameter / Width: 0.6299216 inch
- Maximum Length: 4.724412 inch
- Electrode Type: Ammonia (NH3), Ammonium (NH4+), Bromide (Br-), Cadmium (Cd2+), Calcium (Ca2+), Carbon Dioxide (CO2), Chloride (Cl-), Chlorine (Cl2), Cupric (Cu2+), Fluoride (F-), Fluoroborate
- Sample Type: Aqueous
-
Description: ASI reference electrodes feature reliable, stable, drift free performance in a variety of sample types. The silver/silver chloride references offer high stability and should be used for most sample types. The calomel reference is ideal for use in Tris buffers or in the presence of organics,
- Operating Temperature: 176 F
- Junction Type: Double Junction, Single Junction
- Features: Food / Sanitary, Measures pH
- Body Material: Glass
-
Supplier: Hanna Instruments, Inc.
Description: No Description Provided
- pH Range: -2 to 16 pH
- Accuracy: 0.01 ±pH
- ORP / Redox Range: -2,000 to 2,000 millivolts
- Operating Temperature: 32 to 122 F
-
Supplier: Instrumentation Northwest, Inc.
Description: The TempHion™ Smart Sensor is a submersible water quality sensor and datalogger capable of measuring pH, specific ions, redox, and temperature. Each unit comes with a thermistor based temperature element plus up to three pH, ISE, or redox elements. The TempHion™ comes with INW's powerful,
-
Supplier: AENOR
Description: Animal feeding stuffs - Determination of fluoride content after hydrochloric acid treatment by ion-sensitive electrode method (ISE)
-
Supplier: ABB Measurement & Analytics
Description: The Aztec 600 ISE ammonia analyzer provides reliable and accurate measurement of ammonia concentrations for a wide variety of applications including source water monitoring and wastewater nutrient removal. The Aztec 600 ISE ammonia analyzer uses a robust gas sensing ammonia
- Operating Temperature: 41 to 104 F
- Electrical Output: Analog Voltage Output, Switch / Alarm Relay Output
- Features and Functionality: Built-in or Self-calibration
- Display Type: Digital Display
-
Supplier: Myron L Company
Description: BENEFITS: Reliable Repeatable Results Accurate Affordable Easy to Use Rugged Design Ensure Product Quality Reduce Waste Protect the Environment HIGH PERFORMANCE FEATURES: Nitrate Concentration (ppm N or ppm NO3 - ) or mV 1 and 2 Point Calibration Options Proprietary ISE Sensor Design Built-in
- Operating Temperature: 32 to 104 F
- Features and Functionality: Battery Powered
- Display Type: Digital Display
- Form Factor: Hand Held
-
Supplier: Myron L Company
Description: BENEFITS: Reliable Repeatable Results Affordable Rugged Design Reduce Waste Accurate Easy to Use Ensure Product Quality Protect the Environment HIGH PERFORMANCE FEATURES: Nitrate Concentration (ppm N or ppm NO3- ) or mV 1 and 2 Point Calibration Options Proprietary ISE Sensor Design Built-in
- Operating Temperature: 32 to 104 F
- Features and Functionality: Battery Powered
- User Controls: Computer Interface
- Form Factor: Hand Held
-
Supplier: Telatemp Corporation
Description: Telatemp’s pHTemp2000 Data Logger with LCD display is a battery-powered, stand-alone ph and temperature recorder that measures and records up to 131,071 readings per channel. The pHTemp2000 will directly connect to many commonly used pH, ORP and ISE electrodes through a female BNC
-
Supplier: OMEGA Engineering, Inc.
Description: The OM-CP-PHTEMP2000 is a battery powered, stand alone pH and temperature data logger with an LCD. The OM-CP-PHTEMP2000 will directly connect to many commonly used pH, ORP and ISE electrodes through a female BNC connector mounted on its side. Temperature compensation is done
- Analog Input Channels: 1 #
- Operating Temperature: 23 to 122 F
- Features: Application Software Included
- User Interface: Computer Programmable, Front Panel and Display
-
Standards and Technical Documents - Standard Test Methods for Fluoride Ion in Water -- ASTM D1179-04Supplier: ASTM International
Description: ion selective electrode (ISE) method. The procedure covers the range from 0.1 to 2.6 mg/L of fluoride. 1.3 Test Method B covers the accurate measurement of simple fluoride ion in water by means of an ion selective electrode. With this test method, distillation is eliminated
-
Supplier: Emerson Automation Solutions – Rosemount
Description: MULTI-PARAMETER INSTRUMENT – up to three inputs: Choose pH/ORP/ISE or Contacting Conductivity/Resistivity, in any combination LARGE DISPLAY – easy-to-read process measurements EASY TO INSTALL – modular boards, removable connectors, easy to wire power, sensors and outputs INTUITIVE MENU
- pH Range: 0 to 14 pH
- Accuracy: 0.01 ±pH
- ORP / Redox Range: -1,500 to 1,500 millivolts
- Control Relays: 4
-
Supplier: Analytical Technology, Inc.
Description: possible. Loss of chemical feed can also be detected quickly and reliably with on-line fluoride monitoring. ATI’s Model A15/82 Fluoride Monitor provides continuous measurement of free fluoride concentration in potable water. The system employs a fluoride sensitive ion selective electrode
-
Supplier: ABB Measurement & Analytics
Description: User benefits: Measure up to 3 different sample streams using a single analyzer Automatic electrode regeneration ensures electrode sensitivity when measuring trace sodium levels Low reagent consumption and novel design with no moving parts reduces maintenance requirements and minimizes
- Operating Temperature: 32 to 131 F
- User Controls: None
- Electrical Output: Switch / Alarm Relay Output
- Instrument Specific Features: Temperature Compensation
-
Supplier: ASTM International
Description: 1.1 This practice provides a procedure for the preparation of samples of plutonium (Pu) materials, using pyrohydrolysis, for subsequent measurement of fluoride, chloride, or both, by ion chromatography (IC) or ion-selective electrode (ISE). 1.2 This practice utilizes a sample size of
Find Suppliers by Category Top
Featured Products Top
-
The PT6 is designed with high-performance features including: proprietary ISE sensor design; readings in concentration, ppm N or ppm NO3–, or mV; built-in double junction reference electrode; 1- and 2-point calibration options; user-selectable LIVE and HOLD modes; IP (read more)
Browse Water Quality Testing Instruments Datasheets for Myron L Company
Conduct Research Top
-
ISE - Fill Solutions and ISA (.pdf)
Application note: Fill Solutions and ISA. For Denver Instrument Ion Selective Electrodes.
More Information Top
-
A solid-contact Pb2+ -selective polymeric membrane electrode with Nafion-doped poly(pyrrole) as ion-to-electron transducer
The above-prepared electrodes are denoted as the GC/ PPy-Nafion/Pb2+ -ISE and GC/Pb2+ - ISE electrodes , respec- tively.
-
Ion‐Selective Electrode Potentiometry in Environmental Analysis
First, Kounaves [137] described the development of an ISE electrode array that may be used with a robotic chemical laboratory for the analysis of calcium, potassium, sodium and chloride as a means of detecting bacterial growth on Mars.
-
Evaluation of Phosphate Ion-Selective Membranes and Cobalt-Based Electrodes for Soil Nutrient Sensing
The phosphate membranes were formed by dipping the free ends of ISE electrode bodies (Hitachi Ltd., Tokyo, Japan) in the casting solution three times.
-
Development of Polymeric Resin Ion‐exchanger Based Chloride Ion‐selective Electrode for Monitoring Chloride Ion in Environmental Water
Fluka ISE electrode body containing 0.01 M KCl as inter- nal filling solution.
-
Measurement of Magnesium Stability Constants of Biologically Relevant Ligands by Simultaneous Use of pH and Ion-Selective Electrodes
For the pyroglutamate system, the results from the pH and Mg- ISE electrode measure- ments are in excellent agreement for the ML constant.
-
Synthesis and characterization of high-integrity solid-contact polymeric ion sensors
The treated electrodes were rinsed with Milli-Q water and dried in air, and the POT/ ISE electrode was peeled from the gold substrate.
-
Membrane drotaverine-selective electrodes based on tetraphenylborate derivatives: Electrochemical, adsorption, and transport properties and analytical applicat...
The ISE elec- trode properties were optimum at a polymer (PVC)-to- plasticizer (DBP) ratio of 1 : (1.5–2.0) and at an ionophore concentration in the membrane of (10–3.5) × 10–3 mol/kg DBP.
-
All-solid-state ion-selective electrodes with ion-to-electron transducers for dopamine determination
Chronopotentiograms of (1 ) CFT and (2, 3 ) ISE electrodes with PPG and PANI transducers, respectively, in 1×10 – 3 M dopa- .
-
All-solid-state ion-selective electrodes for determining amiodarone
Chronopotentiograms of (1 ) CFT and (2, 3 ) ISE electrodes with PPG and PANI transducers, respectively, in 1 ´ 10 – 3 M .
-
On the activity of ions and the junction potential: Revised values for all data
In this convention the ISE electrode is written at the right and the reference electrode at the left.
Indicates content that may require registration and/or purchase.