Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Isotech, Inc.
Description: The ultimate solution for precision marking and micro-processing of all types of metals and plastics. Extremely compact, modular and perfectly sealed, it is configured for easy integration into any industrial production line. Isotech’s laser cutting systems offer the perfect
- Process / Operation: Laser Cutting
-
Supplier: Ross Optical Industries
Description: . Our line of products covers wavelength ranges from the ultraviolet to near infrared, including many types of primary laser, biomedical and analytical spectral lines. The filters are mounted in black anodized metal rings.
- Diameter, Square Side, or Rectangular Length: 3 mm
- Filter Shape: Circular
- Filter Surface Quality: 80-50 Scratch / Dig
- Filter Type: Bandpass / Interference Filters
-
Supplier: Andover Corporation
Description: New ADVANTECH™ Line of Hard Coat Bandpass Filters These state-of-the-art filters offer steep slopes, high light transmission, superior durability and long life for demanding applications, such as spectroscopy, fluorescence, imaging and sensing in the biomedical, machine
- Filter Type: Bandpass / Interference Filters
-
-
Supplier: Changchun Yutai Optics Co., Ltd.
Description: Bandpass Filters are used to selectively transmit a portion of the spectrum while rejecting all other wavelengths. Yutai Optics offers a wide variety of Bandpass Filters in a range of bandwidth options for ultraviolet (UV), visible (VIS), or infrared (IR) applications. Laser
- Filter Surface Quality: 60-40 Scratch / Dig, 80-50 Scratch / Dig
- Filter Type: Bandpass / Interference Filters
- Substrate Material: BK7 Glass, Fused Silica
- Thickness: 0.5000 to 6 mm
-
Supplier: Edmund Optics Inc.
Description: applications to selectively transmit a narrow range of wavelengths while blocking all others. Interference filters are widely used in instrumentation for clinical chemistry, environmental testing, colorimetry, elemental and laser line separation, flame photometry,
- Filter Type: Bandpass / Interference Filters, Spectral Filters
-
Supplier: Edmund Optics Inc.
Description: applications to selectively transmit a narrow range of wavelengths while blocking all others. Interference filters are widely used in instrumentation for clinical chemistry, environmental testing, colorimetry, elemental and laser line separation, flame photometry,
- Filter Type: Bandpass / Interference Filters, Spectral Filters
-
Supplier: Edmund Optics Inc.
Description: applications to selectively transmit a narrow range of wavelengths while blocking all others. Interference filters are widely used in instrumentation for clinical chemistry, environmental testing, colorimetry, elemental and laser line separation, flame photometry,
- Filter Type: Bandpass / Interference Filters
-
Supplier: Edmund Optics Inc.
Description: applications to selectively transmit a narrow range of wavelengths while blocking all others. Interference filters are widely used in instrumentation for clinical chemistry, environmental testing, colorimetry, elemental and laser line separation, flame photometry,
- Filter Type: Bandpass / Interference Filters
-
Supplier: Alluxa, Inc.
Description: Ultra-narrowband optical interference filter with a 354.72 nm center wavelength (CWL), a 1 nm full-width at half-maximum (FWHM), and wide-range OD6 out-of-band blocking from 200 nm to 1200 nm. This filter is designed to attenuate 532.08 nm and 1064.15 nm laser
- Diameter, Square Side, or Rectangular Length: 50.6 mm
- Filter Shape: Circular
- Filter Type: Bandpass / Interference Filters
- Thickness: 2 mm
-
Supplier: Alluxa, Inc.
Description: Ultra-narrowband optical interference filter with a 1064.15 nm center wavelength (CWL), a 1 nm full-width at half-maximum (FWHM), and wide-range OD6 out-of-band blocking from 200 nm to 1200 nm. This filter is designed to block 354.72 nm and 532.08 nm laser lines
- Diameter, Square Side, or Rectangular Length: 50.6 mm
- Filter Shape: Circular
- Filter Type: Bandpass / Interference Filters
- Thickness: 2 mm
-
Supplier: Alluxa, Inc.
Description: Ultra-narrowband optical interference filter with a 354.72 nm center wavelength (CWL), a 1 nm full-width at half-maximum (FWHM), and wide-range OD6 out-of-band blocking from 200 nm to 1200 nm. This filter is designed to attenuate 532.08 nm and 1064.15 nm laser
- Diameter, Square Side, or Rectangular Length: 25.3 mm
- Filter Shape: Circular
- Filter Type: Bandpass / Interference Filters
- Thickness: 2 mm
-
Supplier: Alluxa, Inc.
Description: Ultra-narrowband optical interference filter with a 532.08 nm center wavelength (CWL), a 1 nm full-width at half-maximum (FWHM), and wide-range OD6 out-of-band blocking from 200 nm to 1200 nm. This filter is designed to attenuate 354.72 nm and 1064.15 nm laser
- Diameter, Square Side, or Rectangular Length: 25.3 mm
- Filter Shape: Circular
- Filter Type: Bandpass / Interference Filters
- Thickness: 2 mm
-
Supplier: Andover Corporation
Description: -infrared and include many of the primary laser, mercury, biomedical and analytical spectral lines. Standard sizes include 12.5mm Ø, 25.0mm Ø, and 50.0mm Ø. All Andover filters are mounted in black anodized metal rings which provide an added measure of protection against
- Diameter, Square Side, or Rectangular Length: 25 mm
- Filter Surface Quality: Other
- Filter Type: Bandpass / Interference Filters
- Thickness: 6.9 mm
-
Supplier: Andover Corporation
Description: -infrared and include many of the primary laser, mercury, biomedical and analytical spectral lines. Standard sizes include 12.5mm Ø, 25.0mm Ø, and 50.0mm Ø. All Andover filters are mounted in black anodized metal rings which provide an added measure of protection against
- Diameter, Square Side, or Rectangular Length: 25 mm
- Filter Surface Quality: Other
- Filter Type: Bandpass / Interference Filters
- Thickness: 7.9 mm
-
Supplier: Andover Corporation
Description: -infrared and include many of the primary laser, mercury, biomedical and analytical spectral lines. Standard sizes include 12.5mm Ø, 25.0mm Ø, and 50.0mm Ø. All Andover filters are mounted in black anodized metal rings which provide an added measure of protection against
- Diameter, Square Side, or Rectangular Length: 12.5 mm
- Filter Surface Quality: Other
- Filter Type: Bandpass / Interference Filters
- Thickness: 5.9 mm
-
Supplier: Rapid Spectral Solutions
Description: Rapid Spectral Solutions (RSS) has a listing of many atomic and laser emission line filters with FWHM of less than 1.0 nm. Getting them in your hands in days to weeks rather than months, for the lowest possible cost, is a challenge we thrive on.
- Application Specific: Infrared (IR), Visible (VIS)
- Diameter, Square Side, or Rectangular Length: 6.25 to 100 mm
- Filter Shape: Circular, Square, Rectangular
- Filter Type: Bandpass / Interference Filters, Other
-
Supplier: Thorlabs, Inc.
Description: %. Hot, cold, backside polished, ultrafast, D-shaped, elliptical, parabolic, concave, and laser line dielectric coated mirrors are available for more specialized applications.
- Application Specific: Infrared (IR), Visible (VIS), Ultra-Violet (UV)
- Diameter, Square Side, or Rectangular Length: 12.5 to 25.4 mm
- Filter Shape: Circular, Rectangular
- Filter Surface Quality: 60-40 Scratch / Dig, 80-50 Scratch / Dig
-
Supplier: Micro-Epsilon Group
Description: The compact optoNCDT 1420 LL laser sensors are designed for measurements of shiny metallic and rough surfaces. The oval light spot, which resembles a short laser line, can better compensate for unevenness such as texture and roughness. Special software algorithms filter
- Interface: Serial
- Laser Safety FDA Class: Class IIIa
- Measurement Range: 1.97 inch
- Operating Temperature: 32 to 122 F
-
Supplier: Micro-Epsilon Group
Description: algorithms and filters in order to avoid interferences such as vibrations, incidence of external light etc. in order to ensure stable results Efficient Using the system TCS 8303.I the treads of tires are coded in color. The cartridges for the mark- ing are inserted in a holder. A
- Industrial Applications: Automotive
- Mounting / Loading: Floor / Free Standing
- Part Diameter / Width: 7.87 to 21.65 inch
- Scan Rate: 19.69 in/sec
-
Supplier: Cascade Optical Corp.
Description: STRESS, ABSORPTION, AND SCATTER. THIS YIELDS THE BEST POSSIBLE SOLUTION FOR TRANSMISSION AND REFLECTION FOR HIGH LASER DAMAGE THRESHOLD AND SEVERE ABRASION REQUIREMENTS. YEAR AFTER YEAR, CASCADE OPTICAL HAS CREATED SEEMINGLY IMPOSSIBLE CUSTOM THIN FILM INTERFERENCE FILTERS
- Cleaning / Parts Washing: Stripping / Coating Removal, Ultrasonic Cleaning
- Location: North America, United States Only, Southwest US Only
- Material / Substrate: Aluminum, Carbide, Copper / Copper Alloys, Glass, Metal, Nickel / Nickel Alloys, Precious Metals, Stainless Steel, Titanium
- Services: Corrosion Inhibitors
Find Suppliers by Category Top
Featured Products Top
-
-film, ultra-narrow bandpass filters will optimize the performance of laser based systems. Ultra-narrowband filters are ideal for use as laser line, laser cleanup, or laser excitation filters in applications such as fluorescence microscopy, flow cytometry, and DNA sequencing. They are (read more)
Browse Optical Bandpass Filters Datasheets for Alluxa, Inc. -
-narrow bandpass filters will optimize the performance of laser based systems. Ultra-narrowband filters are ideal for use as laser line, laser cleanup, or laser excitation filters in applications such as fluorescence microscopy, flow cytometry, and DNA sequencing. They are also highly resistant (read more)
Browse Optical Bandpass Filters Datasheets for Alluxa, Inc. -
filters will optimize the performance of laser based systems. Ultra-narrowband filters are ideal for use as laser line, laser cleanup, or laser excitation filters in applications such as fluorescence microscopy, flow cytometry, and DNA sequencing. They are also highly resistant to laser (read more)
Browse Optical Filters Datasheets for Alluxa, Inc. -
multipath analysis and models interactions with terrain and building structures which redirect energy toward the radar altimeter antenna. Our analysis shows that by including such interactions, the increase in interference beyond the line-of-sight analysis is sufficient to violate the safety margin used by the RTCA for legacy radar altimeters with low performance frequency filters. (read more)
Browse Communications Software Datasheets for Remcom (USA) -
FMAD CP is the latest 1-stage filter family for 3-phase systems, equipped with neutral line. The extremely compact and high-performance filters are ideally suited for use in tight spaces commonly found in today's machinery. The new EMC filter family is ideally suited for devices (read more)
Browse EMI Filters and RFI Filters Datasheets for SCHURTER Inc -
, dichroic, and interference filters, each designed to meet specific wavelength-selective needs and applications. However, if your application requires a custom optical filter we can also assist. Avantier supplies precision filters for: (read more)
Browse Optical Filters Datasheets for Avantier Inc. -
Laser Line filters typically have narrow bandwidths of 2 – 5nm for demanding laser applications. Fluorescence Filters, which have been designed to maximize the energy of the excitation and emission bands, typically have broad bandwidths of 20 – 70nm. Yutai (read more)
Browse Optical Filters Datasheets for Changchun Yutai Optics Co., Ltd. -
ULTRA-Narrow Bandpass Filters With the narrowest bandwidths and highest transmission in the industry, Alluxa’s thin-film, ultra-narrow bandpass filters will optimize the performance of laser based systems. Ultra-narrow filters are ideal for use as laser line, laser (read more)
Browse Optical Bandpass Filters Datasheets for Alluxa, Inc. -
Environmental UV radiation monitoring (UVA/UVB detection). (3) Deep Ultraviolet (DUV) Filters (<300nm) Typical wavelength: 193nm (ArF excimer laser), 248nm (KrF excimer laser). Applications: Semiconductor lithography (DUV lithography). UV Raman spectroscopy. (read more)
Browse Optical Filters Datasheets for Changchun Yutai Optics Co., Ltd. -
extend beyond OD6 (-60dB or 0.0001% transmission), particularly at the excitation laser line. Dichroic filters for flow cytometry must be designed with steep edges and minimal polarization splitting in order to efficiently direct the target fluorescence emission signals to the correct (read more)
Browse Optical Filters Datasheets for Alluxa, Inc.
Conduct Research Top
-
Optical Filters
The article describes the characteristics of different types of optical filters including absorptive filters, interference filters, polarization filters, bandpass filters, notched filters, dichroic filters, neutral density filters, laser line filters, explained their working principle, and stated
More Information Top
-
Particle size distribution instrument. Topical report 13
At the exit of the PMT receiver assemblies there are laser line interference filters with a peak transmittance of 80 percent and full width at half maximum (FWHM) of 6.4 -1.1.3nm (green)and 6.1 f 1.2run (blue).
-
Lidar
Figure 2.1 shows an early but still common type of receiver design that incorporates a collecting lens (instead of the telescope mirror assembly used in lidar), a laser line interference filter , pinhole aperture, Glan-air polarizing prism, and dual photomultiplier tubes …
-
Laser Line Bandpass Interference Filters | Edmund Optics
Our Laser Line Interference Filters are available with a variety of bandwidths and transmission values to suit a multitude of laser applications.
-
A laser scanner for imaging fluorophore labeled molecules in electrophoretic gels
A one inch diameter 543nm laser line interference filter with companion blocker is mounted to the front of the laser in an aluminum holder.
-
Multi-Photon Quantum Information Science and Technology in Integrated Optics
The desired degenerate photons are filtered using high transmission (>95 %) laser line interference filters (Semrock) with centre wavelength (λ0 = 808nm) matched to the degenerate photon pairs λs = λi —fine tuning of wavelength below λ0 can be achieved by tilting the filter …
-
Quantitative and multicomponent analysis of prevalent urinary calculi using Raman spectroscopy
The laser spectral linewidth was further spectrally purified with a laser line interference filter .
-
THE VALIDATION OF A NEW VASCULAR DAMAGE ASSAY FOR PHOTODYNAMIC THERAPY AGENTS
… model 164, Spectra-Physics, Mountain View, CA) equipped with a 514.7 nm notch rejection filter (optical density, OD, at 514.5 nm 26;mod- el 514RB16, Omega Optical, Brattleburo, VT), a 488 nm laser line interference filter (model 03FIL002, Melles Griot …
-
Raman spectroscopic investigations of the acid‐base forms of dithizone
The 488.0 nm line of the argon ion laser was used as the excitation in all cases, and a laser line interference filter was employed to remove plasma lines from the 488.0 nm laser output.
-
Assignment of the Raman‐active modes of the antitumor agent azathioprine by normal‐mode calculations
The laser output was guided through a laser line interference filter (Oriel Model 52630) by a surface-coated mirror, focused by a 42 ð 250 mm double convex lens (DCL) and directed at a 90° incident angle to the silver working electrode …
-
Permanent holographic recording in indium oxide thin films using 193 nm excimer laser radiation
The diffracted portion of the beam was detected by an optical power meter (Newport model 835) equipped with a HeNe laser line interference filter for reduction of opti- cal background noise.
Indicates content that may require registration and/or purchase.