Supplier: CSA Group
Description: IEC 62353:2014 applies to testing of medical electrical equipment and medical electrical systems, hereafter referred to as ME equipment and ME systems, or parts of such equipment or systems, which comply with IEC 60601-1:1988 (second edition) and its amendments and
-
Description: IEC 62353:2014 applies to testing of medical electrical equipment and medical electrical systems, hereafter referred to as ME equipment and ME systems, or parts of such equipment or systems, which comply with IEC 60601-1:1988 (second edition) and its amendments and
-
Supplier: Kikusui America, Inc.
Description: The Leakage Current Tester TOS3200 is designed to perform leakage current (touch current and protective conductor current) tests on general electrical equipment but not medical electrical equipment. It enables you to conduct tests that conform to the
- DC Voltage: 10 to 430 volts
- DC Current: 0.00003 to 0.09 amps
- Features: Automatic, Memory / Storage, Other, Remote Control, Warning Indicator Light
- Form Factor: Bench Top, Rack Mount
-
-
Description: Specification of the requirements for conical (Luer) fittings for use with hyperdemic syringes and needles and with certain other apparatus for medical use such as transfusion and infusion sets. It covers fittings made of rigid and semi-rigid materials and includes test methods for
-
Description: manufacturer provides the MINIMUM RATED RANGE of RADIATION QUALITIES for the compliance test on energy dependence of response; c) the compliance test for analogue displays was removed; d) the compliance tests for range reset, the effect of leakage and recombination losses
-
Supplier: Advanced Power Solutions
Description: medical power supplies for X-ray machines and gamma cameras | medical power supplies for blood analysis machines, mass spectrometers | medical power supplies for chemical laboratory equipment | medical power supplies for refractometers | medical power
- DC Output Voltage: 3.3 to 48 volts
- DC Output Power: 400 watts
- AC Input Voltage: 90 to 264 volts
- Input Frequency: 47 to 63 Hz
-
Description: IEC 61557-16:2014 defines performance requirements for test and measurement equipment to determine the effectiveness of the protective measures of electrical measures for electrical equipment and/or medical electrical equipment described in IEC 62353. It is the
-
Supplier: CSA Group
Description: IEC 61557-16:2014 defines performance requirements for test and measurement equipment to determine the effectiveness of the protective measures of electrical measures for electrical equipment and/or medical electrical equipment described in IEC 62353. It is the
-
Description: IEC 61557-16:2023 specifies the requirements applicable to the performance for test and measurement equipment in order to determine the effectiveness of the protective measures for electrical equipment and/or medical electrical equipment described in IEC 62353.
-
Supplier: Allied Electronics, Inc.
Description: M-Series medically certified adapters platforms are industry leaders for density, efficiency and low leakage current. Popular single DC outputs available with rich features and functionality standard. Medical safety approvals including IEC60601-1 medical safety certs. Low
-
Supplier: Allied Electronics, Inc.
Description: M-Series medically certified adapters platforms are industry leaders for density, efficiency and low leakage current. Popular single DC outputs available with rich features and functionality standard. Medical safety approvals including IEC60601-1 medical safety certs. Low
-
Supplier: Allied Electronics, Inc.
Description: M-Series medically certified adapters platforms are industry leaders for density, efficiency and low leakage current. Popular single DC outputs available with rich features and functionality standard. Medical safety approvals including IEC60601-1 medical safety certs. Low
-
Supplier: Ohmite Manufacturing Co.
Description: The AGM series range of medical filters are designed to suppress undesirable electrical disturbances in power lines. They limit the amplitude of interfering voltages on AC power lines and prevent them from propagating into or out of the filtered equipment. This series is a chassis
- Rated Voltage: 250 volts
- Rated Current: 1 to 50 amps
- Operating Temperature: -25 to 85 C
- Product Standards: CE Conformity Marks, UL Recognized Component Mark (US and Canada)
-
Supplier: ValueTronics International, Inc.
Description: current) Measuring methods for leakage current measurements- Direct measurement Equivalent leakage current Residual current The Gossen Metrawatt SECUTEST SIII test instrument can be configured for international utilization. The test socket, user interface language and the
-
Supplier: Tripp Lite by Eaton
Description: outlet receptacles makes Isolator medical-grade transformers ideal for protecting sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Removes
- Maximum Primary Voltage Rating: 120 volts
- Other Transformer Types / Applications: Isolation Transformer, Medical Transformer
- Features: Medical Grade, Other
- Standards: UL
-
Supplier: Tripp Lite by Eaton
Description: outlet receptacles makes Isolator medical-grade transformers ideal for protecting sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Removes
- Maximum Primary Voltage Rating: 120 volts
- Other Transformer Types / Applications: Isolation Transformer, Medical Transformer
- Features: Medical Grade, Other
- Standards: UL
-
Supplier: Tripp Lite by Eaton
Description: outlet receptacles makes Isolator medical-grade transformers ideal for protecting sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Removes
- Maximum Primary Voltage Rating: 120 volts
- Other Transformer Types / Applications: Isolation Transformer, Medical Transformer
- Features: Medical Grade, Other
- Standards: UL
-
Supplier: Tripp Lite by Eaton
Description: outlet receptacles makes Isolator medical-grade transformers ideal for protecting sensitive electronic equipment in patient-care areas. Faraday shield reduces the cumulative leakage current of the Isolator and connected equipment to levels less than 100 microamps. Removes
- Maximum Primary Voltage Rating: 120 volts
- Other Transformer Types / Applications: Isolation Transformer, Medical Transformer
- Features: Medical Grade, Other
- Standards: UL
-
Supplier: ASTM International
Description: test methods and their validation are described to only cover testing of empty and dry SUSs. Residual liquid in the SUS can impact the test reliability and reproducibility. 1.4 The test methods are intended to be used to confirm the barrier properties of the test article,
-
Supplier: Seaward Group USA
Description: The Rigel 277 Plus is a portable medical electrical safety analyzer for medical device testing, combining IEC/EN 60601-1 compliance with additional test facilities for IEC/EN 61010 (Laboratory Equipment) including Touch Leakage, Voltage Measurement and dedicated
- Current Leakage Range: 0 to 9.99 milliamps
- Resistance Range: 0 to 0.019989999999999997 kohms
- AC Voltage: 6 volts
- AC Current: 0.1 to 25 amps
-
Supplier: ValueTronics International, Inc.
Description: Large LCD Display for Menu Programming and Test Results Internal Storage and Recall of 99 Test Setups Four Terminal Kelvin Connection Front Panel Lockout Prevents Changes to the Test Setup Automatic Offset to Zero Out Stray Lead Resistance I/O Interface for Remote Start and
- Features: Current Leakage Tester, Ground Bond Testers
-
Supplier: Daburn Electronics & Cable
Description: Even more so than with other machines, downtime in hospitals and other medical facilities is simply not an option. From surgical dialysis and testing equipment to patient monitoring and imaging machines, so many important medical machines need reliable power. But picking out a
- AC Input Voltage: 115 volts
- Input Frequency: 50 to 400 Hz
- DC Output Voltage: -24 to 24 volts
- DC Output Current: 0.05 to 0.8 amps
-
Supplier: Haida International Equipment Co., Ltd.
Description: heat test method change ⒐ GB / T2423.22-2002 temperature Test Method ⒑ IEC60068-2-1.1990 temperature chamber test methods ⒒ IEC60068-2-2.1974 high temperature chamber test methods ⒓ GJB150.3 high temperature test ⒔ GJB150.4 low temperature test ⒕ GJB150.9
- Temperature Range: -40 to 100 C
- Temperature Control Accuracy: 0.3 ± °C
- Humidity Range: 10 to 98 % RH
- Width: 2 ± %RH
-
Supplier: TelephoneStuff.com
Description: Tripp Lite's Hospital Grade 700VA UPS System offer medical-grade UPS protection with built-in Line-interactive Voltage Regulation, Intelligent Monitoring and Unattended Shutdown capability with less than 300 microamps leakage current for the UPS and all connected equipment.
- Volt-Amp Rating: 0.7 kVA
- Technology: Line-Interactive
-
Supplier: Dongguan Yili Electronics Co., Ltd.
Description: equipment, signal equipment, office device, communication apparatus, test instrument and medical instruments.
- Maximum Primary Voltage Rating: 115 to 277 volts
- Maximum Secondary Voltage Rating: 9 to 24 volts
- Other Transformer Types / Applications: Industrial Control Transformer
- Category: Signal / RF Transformer
-
Supplier: Dongguan Yili Electronics Co., Ltd.
Description: equipment, signal equipment, office device, communication apparatus, test instrument and medical instruments.
- Maximum Primary Voltage Rating: 115 to 277 volts
- Maximum Secondary Voltage Rating: 9 to 24 volts
- Other Transformer Types / Applications: Industrial Control Transformer
- Category: Signal / RF Transformer
-
Supplier: Agilent Technologies - Vacuum Products
Description: The Agilent VacIon Plus 20 pump is a medium-sized 20 L/s ion pump. It is ideal for a wide range of ultrahigh and extreme high vacuum applications for academic and high-energy physics (HEP) research, and medical equipment use for imaging and radiation therapy. This pump is available
- Ultimate Operating Vacuum: 0.0000000000750283824473074 torr
- Pumping Speed: 57.20976008881164 CFM
- Application: Analytical / Scientific, Medical / Laboratory, Semiconductor Manufacturing
- Configuration: Individual Vacuum Pump
-
Supplier: ValueTronics International, Inc.
Description: The PR57 is a analyzer from Sencore. Analyzers are key tools to test electronic equipment in the engineering, medical, automotive, and technological industries. Use analyzers for monitoring the performances of many different types of electronic devices. You may need analyzers
-
Supplier: TelephoneStuff.com
Description: with hospital-grade plug and outlet receptacles makes Isolator Hospital Grade transformers ideal for the protection of sensitive electronic equipment in patient-care areas. - Reduces the cumulative leakage current of the Isolator and connected equipment to levels below 300
- Other Transformer Types / Applications: Isolation Transformer
-
Supplier: JiuJiang Ingiant Technology Co., Ltd.
Description: Typical applications: Industrial machine processing centers, rotary tables, heavy equipment towers, cable reels, packaging equipment, magnetic clutches, process control equipment, rotary sensors, emergency lighting equipment, robots, exhibition/display equipment,
- Number of Circuits: 47
- Operating Speed: 0 to 600 rpm
- Maximum Voltage: 0 to 240 volts
- Operating Temperature: -40 to 149 F
-
Supplier: Hammond Manufacturing Company Inc.
Description: Features: Intended for non-patient connected indoor applications where protection of sensitive electronics is required: High end audio / studio use Medical electronics High end test equipment / laboratory cULus Listed to UL 60601-1 (1st Edition) and CAN/CSA-C22.2 No. 601.1-M90
- Maximum Primary Voltage Rating: 120 volts
- Power Rating (VA): 1,000 VA
- Other Transformer Types / Applications: Electronics Transformer, Isolation Transformer, Power Transformer
- Standards: RoHS Compliant
-
Supplier: Allied Electronics, Inc.
Description: Combining exceptional attenuation with low leakage current and an extremely compact and light-weight design requiring minimum mounting space the FN3270 is suitable for machines in mixed/domestic environments (Class A/B). These EMC filters help to ensure the compliance with the new product
Find Suppliers by Category Top
Featured Products Top
-
sensitive applications. The CUS500M1 is suitable for use in a wide range of Class I or Class II (double insulated) applications, including home healthcare, medical, dental, test and measurement, broadcast and industrial equipment. The CUS500M1 series accepts an 85 to 264Vac input and has a choice (read more)
Browse Power Supplies Datasheets for TDK-Lambda Americas Inc. -
applications include medical, home healthcare, dental, test and measurement, broadcast and industrial equipment. Initially available with 12V, 24V and 48V outputs, (15V, 18V, 28V and 36V models to follow in Q1 2018), the CUS150M operates from an 85 to 264Vac input and has operating (read more)
Browse Power Supplies Datasheets for TDK-Lambda Americas Inc. -
PMBus communication with a high current standby voltage. With medical and industrial safety certifications, the power supplies are suitable for use in medical, test and measurement, communications and broadcast equipment. Accepting a wide range 90 to 264Vac, 47-440Hz input, the QS7 can (read more)
Browse Power Supplies Datasheets for TDK-Lambda Americas Inc. -
/s, reducing audible noise. Applications include home healthcare, hospital, imaging and clinical diagnostic systems in addition to industrial, test and measurement and communications equipment. Designed as a configurable product, engineers can select from multiple standard options, to (read more)
Browse Medical Power Supplies Datasheets for TDK-Lambda Americas Inc. -
supplies and test equipment and are well suited to applications requiring high voltage isolation or remote sensing capabilities. VMI offers 10kV-25kV Optocouplers. See our Specs and Data (read more)
Browse Optocouplers Datasheets for Voltage Multipliers, Inc. -
standard filter and a medical-grade filter is that capacitors between the circuit conductors have been removed in the medical versions in order to decrease leakage current values. This is important for equipment where leakage current values are tightly controlled by safety standards in order to (read more)
Browse Power Entry Modules Datasheets for Interpower -
, transportation equipment, or industrial machinery, engineers need a vibration test system that delivers accurate results, high uptime, and the flexibility to accommodate evolving test requirements. The EDM Series Electro (read more)
Browse Shock and Vibration Testing Shakers Datasheets for ECON Technologies Co.,Ltd -
example include datacom, medical, test and measurement, and industrial. The FMBB EP filters are designed for rated currents ranging from 1 A to 36 A at an ambient temperature of 40 °C up to 250 V. Standard versions can be used over a temperature range from -40 °C to 100 °C, with (read more)
Browse EMI Filters and RFI Filters Datasheets for SCHURTER Inc -
Vac (1 x MoPP) making the series suitable for B and BF rated medical equipment. Touch current for the CUS30M is a maximum of 100µA and 60µA for the CUS60M, with leakage current less than 250µA and 200µA respectively at 265Vac 60Hz. 5,000m is the maximum operating (read more)
Browse Power Supplies Datasheets for TDK-Lambda Americas Inc. -
handling systems, industrial turntables Defense & Security: Military vehicle turrets, radar antennas, submarine operating systems, national security systems Medical Equipment: Medical imaging systems, surgical robots, diagnostic devices (read more)
Browse RF Rotary Joints Datasheets for JiuJiang Ingiant Technology Co., Ltd.
Conduct Research Top
-
Line Leakage Testing - Is it Right for Your Application? (.pdf)
The Line Leakage test (LLT for short) is most often specified to be performed as a type test in a design or engineering laboratory or as a routine production line test on medical devices right before they ship. Not as commonly performed as a Dielectric Withstand or Ground Bond test in a production
-
Case Study - True Fitness Technology Ensures Equipment Meets Medical Ground Leakage Requirements with Tripp Lite
but had a special problem. Since his. health club is attached to a hospital, he needed our equipment to meet medical ground leakage. requirements. Our job was to source a medically approved isolation transformer, test it and ship. it on location within one week's time." This task would have been
More Information Top
-
ISA MAIN INSTR SYS - Maintenance of Instruments and Systems
Thermal mass flowmeters came of age when they accurately measured low gas flows such as leak testing and medical analytical equipment .
-
CR4 - Thread: Leak tester
You might be interested in: Leak Testing Equipment , Liquid Leak Detectors, Medical Equipment and Supplies .
-
CR4 - Thread: Leakage in Electronic Appliance
For manufacturing applications, check USON: they make Leak Test Equipment for all types of manufacturers in Automotive, Medical , Industrial, and other industries.
-
Leakage Current Test / Testers / Leakage Current Testers
Besides according with the touch current standard of IEC 60990, it also measures up various safety agencies? touch current test standard of which such as the earth leakage current of medical equipment , enclose leakage current, patient leakage current and patient auxiliary.
-
Leakage Current Test / Safety
Besides according with the touch current standard of IEC 60990, it also measures up various safety agencies? touch current test standard of which such as the earth leakage current of medical equipment , enclose leakage current, patient leakage current and patient auxiliary.
-
Leakage Current Test / Safety Test / Ground
Besides according with the touch current standard of IEC 60990, it also measures up various safety agencies? touch current test standard of which such as the earth leakage current of medical equipment , enclose leakage current, patient leakage current and patient auxiliary.