-
Supplier: Linde North America, Inc.
Description: nonflammable, will not support combustion and is not life-supporting. The gas is slightly lighter than air and is only slightly soluble in water. When liquid nitrogen is vaporized and then heated it consumes a large amount of heat, making it an ideal coolant. Nitrogen is
- Applications: Other
- Composition: Pure Gas
- Nitrogen and Nitrogen Compounds: Nitrogen
- Product Forms: Liquid / Liquid Gas
-
Supplier: Accuris
Description: PLANT; FOR PRODUCING, STORING, PUMPING, AND VAPORIZING LIQUID OXYGEN AND LIQUID NITROGEN (SHIPBOARD TYPE)
-
Supplier: MAXPRO Technologies, Inc.
Description: pressures from nitrogen generators Boosting pressures from vaporized liquid nitrogen Features Available for plant air or nitrogen drive Nitrogen drive units include: high pressure regulator with gauge gas supply pressure switch to stop
- Bore Size - HP Outlet: 0.2500 inch
- Bore Size - LP Inlet: 0.2500 inch
- Drive Type: Pneumatic
- Fluid Compatibility: Gas
-
-
Supplier: MAXPRO Technologies, Inc.
Description: pressures from nitrogen generators Boosting pressures from vaporized liquid nitrogen Features Available for plant air or nitrogen drive Nitrogen drive units include: high pressure regulator with gauge gas supply pressure switch to stop
- Bore Size - HP Outlet: 0.2500 inch
- Bore Size - LP Inlet: 0.2500 inch
- Drive Type: Pneumatic
- Fluid Compatibility: Gas
-
Supplier: John Crane, Inc.
Description: As the worldwide leader in spiral groove technology, John Crane is the first to utilize non-contacting seals in cryogenic applications. The Type 285 can safely seal the most common industrial liquid gasses, such as liquid nitrogen, oxygen, argon and carbon dioxide. It fits the
- Mechanical Seal Type: Single Mechanical Seal
- Operating Pressure: Up to 100 psi
- Operating Temperature: Over -320 F
- Seal Application: Pump, Cryogenic Seal
-
Supplier: MAXPRO Technologies, Inc.
Description: pressures from nitrogen generators Boosting pressures from vaporized liquid nitrogen Features Available for plant air or nitrogen drive Nitrogen drive units include: high pressure regulator with gauge gas supply pressure switch to stop
- Bore Size - HP Outlet: 0.2500 inch
- Bore Size - LP Inlet: 0.2500 inch
- Drive Type: Pneumatic
- Fluid Compatibility: Gas
-
Supplier: MAXPRO Technologies, Inc.
Description: pressures from nitrogen generators Boosting pressures from vaporized liquid nitrogen Features Available for plant air or nitrogen drive Nitrogen drive units include: high pressure regulator with gauge gas supply pressure switch to stop
- Bore Size - HP Outlet: 0.2500 inch
- Bore Size - LP Inlet: 0.2500 inch
- Drive Type: Pneumatic
- Fluid Compatibility: Gas
-
Supplier: SAE International
Description: elevating its pressure and vaporizing it to a gas. Once converted it is referred to LCNG. The properties of natural gas are influenced by: (1) source of supply i.e. field, composition or impurities; (2) the processing of natural gas by the production and transmission companies; (3) the
-
Standards and Technical Documents - Standard for Compressed Natural Gas Vehicle Fuel -- J1616_201605Supplier: SAE International
Description: elevating its pressure and vaporizing it to a gas. Once converted it is referred to LCNG. The properties of natural gas are influenced by: (1) source of supply i.e. field, composition or impurities; (2) the processing of natural gas by the production and transmission companies; (3) the
-
Supplier: HORIBA Instruments, Inc.
Description: of water and liquid materials to be added to the deposition process It is believed that the functionality of functional thin films is enhanced in the deposition processes by adding traces of vaporized water (H2O) into the chamber. A system for plasma emission
Find Suppliers by Category Top
Featured Products Top
-
, industry has the power to change its energy source on demand. Like their natural gas counterparts, electric heaters are used for a variety of industrial and commercial processes, including producing hot water or steam and vaporizing liquid to gas. But that’s where many of the similarities end (read more)
Browse Industrial Heaters Datasheets for Gaumer Process -
energy source on demand. Like their natural gas counterparts, electric heaters are used for a variety of industrial and commercial processes, including producing hot water or steam and vaporizing liquid to gas. But that’s where many of the similarities end. Electric heaters are emission (read more)
Browse Electric Heaters Datasheets for Gaumer Process
More Information Top
-
FINAL EVALUATION REPORT-HALLAM NUCLEAR POWER FACILITY. VOLUME II
An analysis of the system indicates that nitrogen flow to the cells will be limited by the liquid nitrogen vaporizer output, (300 scfm for a period of eight hours).
-
Materials behavior in the Nuon Power IGCC Plant in Buggenum
Liquid nitrogen vaporiser : In the liquid nitrogen vaporiser, however, the effects of cyclic operation have become clearly visible.
-
CRANFIELD UNIVERSITY
LUIGI SERIO
In order to reduce the temperature difference, the high pressure helium gas at 300 K is cooled down via a liquid nitrogen vaporiser to about 120 K before entering the cryostat.
-
Perspectives on development/changes in emphasis in power generation, and impacts on materials issues, in the last four years Part A: Summary of topics discusse...
The liquid nitrogen vaporizer was not designed for cyclic operation; thermal fatigue damage had initiated repeatedly as a result of frequently-occurring, high-nitrogen demand.
-
Distillation Troubleshooting Complete Document
The liquid nitrogen vaporizer is believed to have malfunctioned without an alarm.
-
Bookshelf and Unified Agenda > Independent Agencies / Commissions > Nuclear Regulatory Commission > NUREG Series Publications > NUREG-1856 - Safety Evaluation...
This equipment includes a nitrogen storage vessel, electric liquid nitrogen vaporizers , instrumentation, and appropriate piping, flow control stations, and isolation valves.
-
Advanced Hypersonic Test Facilities > NASA Glenn Research Center's Hypersonic Tunnel Facility
The railcar is charged using a liquid nitrogen vaporizer station that is capable of generating gaseous nitrogen at a rate of 1870 m3 (66,000 ft3 ) per hour.
-
Safety considerations relative to construction of E/STS 2-3
Liquid nitrogen vaporizers are provided to supply gaseous nitrogen as follows; .
-
Heavy oil recovery process: Conceptual engineering of a downhole methanator and preliminary estimate of facilities cost for application to North Slope Alaska
liquid Nitrogen vaporizer provldes .
-
WABASH RIVER COAL GASIFICATION REPOWERING PROJECT
The first modification was the addition of a supplemental liquid nitrogen vaporizer attached to the main exchanger cold box, utilizing warm, purified air from the air purification system to vaporize liquid nitrogen (LIN) from the nitrogen storage and handling system (Figure 5…
Indicates content that may require registration and/or purchase.