Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Instrumentation Northwest, Inc.
Description: The Aquistar® Dissolved Oxygen (DO) sensor represents the next generation in trouble-free oxygen-sensing design. Utilizing fluorescence of a stable, immobilized ruthenium-based film matrix, the sensor employs precision optical transmission and detection to measure
-
Supplier: CO2Meter.com
Description: The Zirconia Oxygen Sensor System offers a complete oxygen level measurement solution removing the need for customers to develop their own electronics. It can be used in combustion control systems, coal, oil, gas, biomass and in oxygen generation systems. When connected
- Number of Gases Sensed: Single Gas
- Operating Temperature: -30 to -22 F
- Specific Gas Types: Oxygen (O2)
-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: Gasboard 7500E can be used to measure the gas flow and oxygen concentration based on the ultrasonic technology, which has better performance than electro-chemical and other oxygen sensors. With the function of data display, online monitoring, etc., it has been widely used
- Measurement Type: %Volume
- Number of Gases Sensed: Single Gas
- Operating Humidity: 5 to 85 %
- Operating Temperature: 50 to 122 F
-
-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: Gasboard7500C is an economical oxygen sensor used to detect oxygen concentration and gas flow in binary gases. Adopting ultrasonic detecting technology, It has better performance than electro-chemical and other oxygen sensors. It has function including data
- Measurement Type: %Volume
- Number of Gases Sensed: Single Gas
- Operating Humidity: 5 to 85 %
- Operating Temperature: 50 to 131 F
-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: It is an economical gas sensor used to detect oxygen concentration in binary gases. Adopting ultrasonic detecting technology, it is very stable and there is no need to calibrate the sensor in the application. It is mainly designed for ventilator oxygen concentration
- Measurement Type: %Volume
- Number of Gases Sensed: Single Gas
- Operating Humidity: 5 to 85 %
- Operating Temperature: 50 to 122 F
-
Supplier: ABB Measurement & Analytics
Description: 9408-80 systems complement the highly successful 9408 floating ball, dip and submersible systems and employ the well-proven 8012 oxygen sensor. A key feature is the bayonet snap-fit connection which makes removal for calibration very easy and convenient. The typical life of the 8012
- Accuracy: 0.1000 ppm
- Control Relays: 2
- Controller Functionality: Yes
- Dissolved O2 Range: 0.0 to 20 ppm
-
Supplier: Cubic Sensor and Instrument Co.,Ltd.
Description: Gasboard 7500E can be used to measure the gas flow and oxygen concentration based on the ultrasonic technology, which has better performance than electro-chemical and other oxygen sensors. With the function of data display, online monitoring, etc., it has been widely used
- Gas Volumetric Flow Rate: 0.0 to 0.3531 SCFM
- Electrical Output: Analog Voltage
- Operating Temperature: 50 to 122 F
- Process Media Type: Gas
-
Supplier: CO2Meter.com
Description: The Zirconia Oxygen Sensor System offers a complete oxygen level measurement solution removing the need for customers to develop their own electronics. It can be used in combustion control systems, coal, oil, gas, biomass and in oxygen generation systems. When connected
- Number of Gases Sensed: Single Gas
- Operating Temperature: -30 to -22 F
- Specific Gas Types: Oxygen (O2)
-
Supplier: SST Sensing Ltd.
Description: The LuminOx Flow-Through Optical Oxygen Sensor Allows For A Clean Gas Sample Stream Directly Into The Sensor Which Can Be Completely Removed From The Process Environment. The LuminOx Flow-through Optical Oxygen Sensor is developed and manufactured by
- Number of Gases Sensed: Single Gas
- Operating Temperature: -22 to 140 F
- Specific Gas Types: Oxygen (O2)
-
Supplier: CO2Meter.com
Description: he LOX-O2-F: UV Flux 25% Oxygen Flow Through Sensor (formerly known as OX-0055) measures ambient oxygen levels using the principle of fluorescence quenching by oxygen. This provides the benefits of lower power requirements and a longer lifetime. Features
- Operating Temperature: -22 to 140 F
- Specific Gas Types: Oxygen (O2)
-
Supplier: CO2Meter.com
Description: he LOX-O2-F: UV Flux 25% Oxygen Flow Through Sensor (formerly known as OX-0055) measures ambient oxygen levels using the principle of fluorescence quenching by oxygen. This provides the benefits of lower power requirements and a longer lifetime. Features
- Operating Temperature: -22 to 140 F
- Specific Gas Types: Oxygen (O2)
-
Supplier: Edgetech Instruments Inc.
Description: . Measuring Range The unit will offer ranges between 0-100ppm, 0-1,000ppm, 0-10,000ppm of oxygen. 0-1% to 0-25% O2. Sensor The OxyTrans uses a special fuel cell to measure the oxygen concentration. The sensor meets the industrial requirements for accuracy, sensitivity,
- Electrical Outputs: Analog Current
- General Gas Types: Combustible Gas
- Measurement Type: %Volume, Trace
- Number of Gases Sensed: Single Gas
-
Supplier: Teledyne Monitor Labs, Inc.
Description: engineers will appreciate the in situ design of the oxygen analysis probe. It provides the rapid response required for combustion control while eliminating the need for high maintenance sampling components. The flue gas flow around the zirconium oxide sensor is
- Electrical Outputs: Analog Current
- Measurement Type: %Volume
- Number of Gases Sensed: Single Gas
- Operating Temperature: 25 to 125 F
-
Supplier: Emerson Automation Solutions – Rosemount
Description: The Model 499ATRDO sensor is a membrane-covered amperometric sensor. It is primarily used to measure trace oxygen levels in deaerated boiler feedwater in steam electric power plants. HIGH ACCURACY: + ppb error below 20 ppb RAPID STABILIZATION following
- Accuracy: 5 % FS
- Built-in Temperature Sensor: Yes
- Cell Type: Galvanic
- Maximum Diameter / Width: 1 inch
-
Supplier: SST Sensing Ltd.
Description: The Zirconia Oxygen Sensor System offers a complete solution, removing the need for customers to develop their own electronics. Frequently used in combustion control systems, burning coal, oil, gas and biomass and in oxygen generation systems. The Zirconia Oxygen
- Electrical Outputs: Analog Voltage, Analog Current
- Number of Gases Sensed: Single Gas
- Specific Gas Types: Oxygen (O2)
-
Supplier: Campbell Scientific, Inc.
Description: The CS511 is a rugged, low-maintenance sensor that is manufactured by Sensorex. It consists of a self-polarizing galvanic cell that generates a millivolt signal proportional to the amount of oxygen present in the measured medium (typically water). Oxygen diffuses through its
- Accuracy: 2 % FS
- Built-in Temperature Sensor: Yes
- Cell Type: Galvanic
- Disposable Membrane Cap: Yes
-
Supplier: SST Sensing Ltd.
Description: The Screwfit zirconium dioxide oxygen sensors has a threaded probe design making it easy to install. Suitable for combustion control within industrial coal/oil/gas/biomass boilers, continuous emission monitoring systems and controlled atmosphere monitoring. SST’s range of
- Number of Gases Sensed: Single Gas
- Specific Gas Types: Oxygen (O2)
-
Supplier: Angst+Pfister Sensors and Power
Description: Product type SensorMeasuring range 0-1000 ppmDevice type Portable, StationaryGasflow Flow by diffusion, Forced flowTechnology ZirconiaApprovals NoOutput signal 55 +/-25 µA in 1000 ppm oxygenFeatures Zirconia, ppm oxygen sensorSupplier Fujikura
- Electrical Outputs: Analog Current
-
Supplier: Edgetech Instruments Inc.
Description: Range The unit will offer ranges between 0-100ppm, 0-1,000ppm, 0-10,000ppm of oxygen. 0-1% to 0-25% O2. Sensor The OxyTrans uses a special fuel cell to measure the oxygen concentration. The sensor meets the industrial requirements for accuracy, sensitivity, easy to use
- Electrical Outputs: Analog Current
- General Gas Types: Combustible Gas
- Measurement Type: Trace
- Number of Gases Sensed: Single Gas
-
Supplier: Angst+Pfister Sensors and Power
Description: Product type Gas sensor moduleMeasuring range 0,1-95 %Device type StationaryGasflow Forced flowTechnology ZirconiaApprovals NoOutput signal 4-20 mAFeatures Zirconia, long lifetime, integrated flow cellSupplier Angst+Pfister Sensors and Power
- Electrical Outputs: Analog Current
-
Supplier: Angst+Pfister Sensors and Power
Description: Product type Gas sensor moduleMeasuring range 0-25 %Device type StationaryGasflow Forced flowTechnology ZirconiaApprovals NoOutput signal 4-20 mAFeatures Zirconia, long lifetime, integrated flow cellSupplier Angst+Pfister Sensors and Power
- Electrical Outputs: Analog Current
-
Supplier: Angst+Pfister Sensors and Power
Description: Product type SensorMeasuring range 0-5 %Device type Portable, StationaryGasflow Flow by diffusion, Forced flowTechnology ZirconiaApprovals NoOutput signal 165 +/-30 µA in 5% oxygenFeatures Zirconia,Supplier Fujikura
- Electrical Outputs: Analog Current
-
Supplier: Chicago Pneumatic and Pneumatech
Description: generator unique? Purelogic™ controller for full communication and monitoring possibilities. Produced in-house with unique design features. Plug and play: no specialist needed for the installation. A zirconia oxygen sensor with a long lifetime
- Generator Type: Oxygen
- Output Flow Rate: 391 SLM
-
Supplier: Process Sensing Technologies USA
Description: The LuminOx Flow-Through Optical Oxygen Sensor Allows For A Clean Gas Sample Stream Directly Into The Sensor Which Can Be Completely Removed From The Process Environment. The LuminOx Flow-through Optical Oxygen Sensor is developed and manufactured by
- Operating Humidity: Over 0.0 %
-
Supplier: SST Sensing Ltd.
Description: The Probe zirconium dioxide oxygen sensors are available in three lengths. Suitable for aggressive and polluted applications such as boiler exhausts. Longer probes are an ideal solution for thicker walled, insulated flue pipes. SST’s range of zirconium dioxide oxygen
- Number of Gases Sensed: Single Gas
- Specific Gas Types: Oxygen (O2)
-
Supplier: Edgetech Instruments Inc.
Description: Range The unit will offer ranges between 0-100ppm, 0-1,000ppm, 0-10,000ppm of oxygen. 0-1% to 0-25% O2. Sensor The OxyTrans uses a special fuel cell to measure the oxygen concentration. The sensor meets the industrial requirements for accuracy, sensitivity, easy to use
- Display: Digital
- Electrical Outputs: Analog Current
- General Gas Types: Combustible Gas
- Measurement Type: Trace
-
Supplier: DigiKey
Description: VARIABLE AREA FLOW METER, OXYGEN
-
Supplier: Emerson Automation Solutions – Rosemount
Description: PERMEABILITY VARIOPOL CONNECTOR OPTION allows the sensor to be replaced without running new cable. The Model 499AOZ sensor a membrane-covered amperometric sensor for the continuous determination of dissolved ozone in water. The major applications are measuring ozone in municipal
- Cell Type: Polarographic
- Maximum Diameter / Width: 1 inch
- Maximum Length: 5.63 to 7.75 inch
- Minimum Flow Rate: 30.48 cm/sec
-
Supplier: Panametrics
Description: maintenance costs. Key user benefits of the XMO2pro: Robust sensor, resistant to contamination and flow fluctuations, no moving parts and consumables Highly accurate O2 measurements in various gases Compact design for cost-effective integration into the process
- Application: Process Gas
- Display: Digital
- Electrical Outputs: Analog Current
- Features: Hazardous Environments
-
Supplier: Process Sensing Technologies USA
Description: for oxygen concentrators. The flexibility is further enhanced by different mounting options and multiple sensor types Features: Zirconia or electrochemical sensor technology options 0 to 100ppm, 0 to 1,000ppm, 0 to 25%, 0 to 96% O2 Gas connections via KF40 or Flow
- Display: Digital
- Features: Self Calibration
- Instrument Type: Analyzer
- Measurement Type: %Volume, Trace
-
Supplier: Sensidyne, LP
Description: ) Temperature Range .................... ............... -20° to 50°C (-4° to 122°F) Humidity Range (continuous) .................... .. 5–95 %RH, non-condensing Pressure Range .................... .................... .. Ambient atmospheric, ± 1 psi Recommended Calibration Flow Rate
- Features: Intrinsically Safe
- General Gas Types: Combustible Gas
- Measurement Type: %Volume
- Number of Gases Sensed: Single Gas
-
Supplier: Sensidyne, LP
Description: ) Temperature Range .................... ............... -20° to 50°C (-4° to 122°F) Humidity Range (continuous) .................... .. 5–95 %RH, non-condensing Pressure Range .................... .................... .. Ambient atmospheric, ± 1 psi Recommended Calibration Flow Rate
- Features: Intrinsically Safe
- General Gas Types: Combustible Gas
- Measurement Type: %Volume
- Number of Gases Sensed: Single Gas
Find Suppliers by Category Top
Featured Products Top
-
Amperometric zirconia oxygen sensors are extensively employed in many different industrial sectors like power plants, chemical plants, and food processing etc., where precise oxygen measurement is essentially needed. With over 30 years of experience, Angst Pfister Sensors and Power (formerly (read more)
Browse Gas Sensors Datasheets for Angst+Pfister Sensors and Power -
Sensore’s percentage oxygen sensors are engineered for accurate and reliable measurement of oxygen concentrations ranging from low percentage levels up to 100% O?. Built on proven zirconia technology, these sensors offer fast response, excellent long-term stability, and are ideal for (read more)
Browse Dissolved Oxygen Sensors Datasheets for Sensore Electronic GmbH -
Angst+Pfister Sensors & Power is proud to unveil the FCX-TR2 - a next-generation oxygen transmitter designed for fast integration and low (read more)
Browse Gas Sensors Datasheets for Angst+Pfister Sensors and Power -
The Zirconia Oxygen Sensor System is a complete solution for measuring oxygen in high-temperature industrial processes. Based on zirconium dioxide sensing technology, it delivers accurate and stable O? measurement for combustion control and process monitoring (read more)
Browse Gas Sensors Datasheets for SST Sensing Ltd. -
temperature range from –100°C to 400°C. At its core, the analyser uses a zirconium dioxide oxygen sensor that requires no reference gas, providing long-term reliability and low maintenance. Housed in a robust stainless steel probe with a sintered stainless steel cap, the (read more)
Browse Gas Sensors Datasheets for SST Sensing Ltd. -
The PCB-mounted oxygen Sensor is designed for easy integration into electronic systems requiring reliable oxygen measurement. Its PCB-mountable format allows direct installation onto circuit boards, reducing wiring complexity and simplifying system design for OEM (read more)
Browse Gas Sensors Datasheets for SST Sensing Ltd. -
The Zirconia Oxygen Sensor Probe Kit provides a complete solution for high-temperature oxygen measurement using proven zirconium dioxide sensing technology. The kit is designed to simplify installation and setup while delivering accurate and responsive O (read more)
Browse Gas Sensors Datasheets for SST Sensing Ltd. -
The Miniature Zirconium Dioxide Oxygen Sensor is designed to deliver accurate oxygen measurement in high-temperature environments where space is limited. Using zirconia sensing technology, it offers fast response times and reliable performance for combustion and (read more)
Browse Gas Sensors Datasheets for SST Sensing Ltd. -
Sensore’s trace oxygen sensors are designed for applications requiring highly accurate measurement of very low oxygen concentrations—from percentage levels down to parts per million (ppm). These advanced sensors are ideal for monitoring oxygen in inert gas systems, glove boxes, gas (read more)
Browse Dissolved Oxygen Sensors Datasheets for Sensore Electronic GmbH -
CO2Meter partners with GasLab, Inc. to launch RAD-0002-ZR Oxygen Deficiency Alarm for Low Temperatures to Exceed Current Standards The new, wall-mounted safety device, the Oxygen Deficiency Alarm for Low Temperatures is used across cold storage applications (read more)
Browse Gas Sensors Datasheets for CO2Meter.com
Conduct Research Top
-
How Do Mass Air Flow Sensors Work?
Mass air flow sensors are detection devices that are used to measure mass flow rate, and they play a critical role in the function of various medical equipment. Respirators, ventilators, anesthesia equipment, oxygen concentrators, and many other medical devices rely on mass air flow sensors
-
Oxygen Permeation Measurements in Bottles Using OxySense Non- Invasive Oxygen Measurement Instrumentation (.pdf)
is collected by this gas and is taken to a sensor that measures the concentration. The permeation tests can last several days during which gas has to flow continuously while the instrument is measuring continuously. This measurement process uses considerable amounts of gas throughout the test and does
-
Gas Sensors in Medical Applications
Human life relies on respiration: the intake of oxygen and the release of carbon dioxide. Respiration provides a constant flow of oxygen molecules to our brain, organs and tissues while providing a way to remove the waste CO2 molecules that are created in the cells. Without respiration, our bodies
-
Application Note: Sensors in Anesthesia Machines
A medical anesthesia machine is designed to deliver drugs that help to. eliminate pain and other unwanted sensations. The continuous flow anesthetic machine provides an accurate and. constant supply of medical gases (such as air, oxygen and nitrous oxide) mixed with an accurate concentration
-
Dilution Flow Panels for Combustible Gas Monitoring
the presence of oxygen. Catalytic combustible sensors detect the presence of many. combustible gases, including natural gas (methane), solvent vapors, hydrogen, ammonia, and even carbon monoxide. Due. to its simplicity, rugged design, and versatility, catalytic combustible sensors are employed in many
-
Feed Forward Control (.pdf)
This case history describes how one company used the CalorVal BTU Analyzer with an oxygen sensor and flow meter to complete their control loop system for optimizing fuel/air mixtures.
More Information Top
-
Basic Clinical Anesthesia
Some machines are equipped with the minimum manda- tory oxygen flow sensor of 50–250 mL/min.
-
Run-to-run control framework for VLSI manufacturing
target changed after run #8) as well as process perturbations such as sensor drift ( oxygen flow sensor .
-
Minimal impairment in pulmonary function following laparoscopic surgery
SpO2 is monitored with a built-in pulse oximeter, and expired oxygen is measured with an oxygen flow sensor .
-
Automation of twin-bath furnace control
… cable tension sensor; SS) synchronization sensor; SLI-SL5) signal lamps; If) interface in- dicator; RI) recording instrument; U,D) eontactor (up and down); IR, 2R) output relays (raising and lowering) ; CPS) current protection sensor; 02) oxygen flow sensor ; PP) power pack; MU …
-
http://dspace.mit.edu/bitstream/handle/1721.1/36949/32875514-MIT.pdf?sequence=2
A low flow oxygen sensor was also installed in the loop water sample line.
-
Small Break Air Ingress Experiment
The oxygen sensor and flow meter were switched on.
-
Titration of gases with oxygen using a zirconia oxygen pump-gauge
Using the zirconia pump-gauge composed of a zirconia oxygen pump and a zirconia oxygen sensor , flowing gases can be titrated with oxygen in a similar way to the pH titration in aqueous solutions.
-
Electrical Power & Energy Systems
The ECU will detect the oxygen concentration in the exhaust flow with oxygen sensor to determine the amount of fuel to be injected.
-
Lead-Bismuth Activities at the Karlsruhe Lead Laboratory KALLA
Among others, latest results are presented of: characteristics of oxygen sensors in flowing liquid Pb-Bi, the oxygen control system (OCS) operating on a loop system, an ultrasonic flow meter applied to lead-bismuth at 400 deg. C.
-
Closed-loop control for anesthesia breathing systems
The multicomponent circle system was reduced to a compact breathing system with integrated inspiratory and expiratory valves, oxygen sensor , flow sensor, and pressure sensor pick-up.
Indicates content that may require registration and/or purchase.