Supplier: Pollution Systems
Description: Venturi Scrubbers & Particulate Scrubbers Particulate Scrubbers, often called Venturi Scrubbers, are effective at removing particulate from exhaust with high efficiency. Particulate scrubbers have several advantages compared to other dust collection equipment. They
- Efficiency: 99 %
- Filter Type: Venturi
- Orientation: Vertical
- Process Type: Wet
-
Supplier: Pollution Systems
Description: effective particulate/dust scrubbers to fit your precise application. Wet Particulate/Dust Scrubbers The concept of wet particulate/dust scrubbers is pretty straightforward. A liquid – usually water – is injected into the waste gas stream. The liquid droplets impact and entrain
- Orientation: Horizontal
- Pollutants Scrubbed: Other Pollutants
- Process Type: Wet
-
Supplier: Pollution Systems
Description: Gas Scrubbers & Chemical Scrubbers Pollution Systems offers Chemical Scrubbers, aka Gas Scrubbers, that are efficiently and effectively designed to remove gas pollutants. Often these pollutants are chemicals such as ammonia, chlorine or sulfur compounds. These High
- Pollutants Scrubbed: Ammonia, Caustic, Chlorine Gas
- Orientation: Vertical
-
-
Supplier: Pollution Systems
Description: Chlorine Scrubbers Chlorine is a frequent byproduct in many chemical reactions. However, manufacturers are required by law to reduce or eliminate emissions of this poisonous gas. Turn to Pollution Systems for a high-quality chlorine scrubber built to fit your requirements. Chlorine
- Pollutants Scrubbed: Chlorine Gas
- Orientation: Vertical
-
Supplier: EnviroCare International, Inc.
Description: MicroMist Scrubber Developed and applied by experienced process engineers, the EnviroCare MicroMist Scrubber was specifically designed to collect sub-micron particulate at very high efficiencies with low energy input. It removes condensables, such as trace metals, while reducing liquid
- Efficiency: 99.5 %
- Minimum Particle Size Filtered: 1 µm
- Pollutants Scrubbed: Acid, Other Pollutants
- Scrubber Type: Building / Enclosure
-
Supplier: Branch Environmental Solutions
Description: might occur. The Jet Venturi can rapidly pull the gas eliminating any need for a fan, provide a high liquid recycle rate for good contact with a large amount of vapor. Chlorine emergency scrubbers and ammonia storage emergency scrubbers are examples of this kind of application.
- Airflow: 50,008.05 SCFM
- Pollutants Scrubbed: Caustic
- Process Type: Wet
- Filter Type: Wet Spray
-
Supplier: Branch Environmental Solutions
Description: Venturi scrubbers are used to remove very small particles; mist and can also remove gases. The open design eliminates opportunities for the solids buildup and minimizes maintenance. Particles down to and including submicron sizes can be captured. Venturi scrubbers can also absorb gases
- Airflow: 50,008.05 SCFM
- Pollutants Scrubbed: Caustic
- Filter Type: Venturi
- Process Type: Wet
-
Supplier: Schutte & Koerting
Description: The Vent Gas Scrubber System is a compact, lightweight, and easy-to-install unit designed for economical and effective control of pollution from low volume sources. The Vent Gas Scrubber System is comprised of a Scrubber combined with a Liquid Gas Separator. Both are available
- Airflow: 5 to 100,000 SCFM
- Minimum Particle Size Filtered: 5 to 40 µm
- Filter Type: Venturi
- Orientation: Vertical
-
Supplier: Schutte & Koerting
Description: Packed Tower Gas Scrubbers are low-energy gas scrubbers. They are used for gas absorption, cooling, and recovery. Because of their high scrubbing efficiency and low power consumption, they are used in many industries for a broad range of applications. Scrubbers of this type
- Airflow: 100 to 100,000 SCFM
- Minimum Particle Size Filtered: 1 to 5 µm
- Pollutants Scrubbed: Ammonia, Caustic, Chlorine Gas
- Orientation: Vertical
-
Supplier: New York Blower Company (The)
Description: New York Blower FRP Radial Fume Exhausters are compact corrosion-resistant fans for moderate pressure, tough fume-handling applications such as laboratory fume hoods, plating and pickling operations, and scrubber systems.
- Air Flow Rate: 0 to 7,500 SCFM
- Static Pressure: 406.7871674924572 to 420.7871674924572 in H2O
- Media Temperature: 250 F
- Maximum Diameter (Fan or Blower Wheel): 8 to 22 inch
-
Supplier: New York Blower Company (The)
Description: New York Blower Series 60 Fans are designed to meet the performance requirements of high-pressure industrial-process systems such as scrubbers, combustion supply and high-speed drying.
- Air Flow Rate: 0 to 66,000 SCFM
- Static Pressure: 406.7871674924572 to 476.7871674924571 in H2O
- Media Temperature: 800 F
- Maximum Diameter (Fan or Blower Wheel): 26 to 59 inch
-
Supplier: AirPro Fan & Blower Co.
Description: AirPro’s heavy-duty, radial tipped fan (RTHS) is designed to move high volumes of air at moderate-to-high pressures and are able to handle both clean and dirty airstreams. The AirPro centrifugal radial tipped fan provides consistent, reliable service with oxidizers, dryers, baghouses,
- Air Flow Rate: 250,000 SCFM
- Static Pressure: 36 in H2O
- Media Temperature: 1,000 F
- Design: Centrifugal
-
Supplier: New York Blower Company (The)
Description: New York Blower Compact GI Fans (General Industrial) are designed for low-capacity, low-pressure industrial processes such as dust collection, grinding-booth exhaust, scrubber exhaust, food, drying ovens and paper-trim systems. Compact GI's feature a choice of aluminum or nickel
- Air Flow Rate: 0 to 2,200 SCFM
- Static Pressure: 406.7871674924572 to 420.7871674924572 in H2O
- Media Temperature: 600 F
- Maximum Diameter (Fan or Blower Wheel): 8 to 14 inch
-
Supplier: Howden
Description: Covent Type C - Backward curved blower fans Howden Covent Type C Fans. Fifteen rotor designs to cover the full market range of from very low through high flow vs. pressure at optimum efficiency. The low flow fans have parallel shrouds for stable performance and the wide
- Media Temperature: 800.6 F
- Design: Centrifugal
- Environment: Clean Air / Gas, Dirty Air / Gas
- Product Form: Packaged (Complete System)
-
Supplier: Twin City Fan & Blower
Description: Application The RTF Radial Tip Fan is designed for applications involving large volumes of clean or dirty gas streams at moderate to high pressure. They are widely used to exhaust gases from bag-type collectors, precipitators, scrubbers, cyclones, and other industrial applications.
- Air Flow Rate: 2,760 to 223,800 SCFM
- Static Pressure: 442.7871674924572 in H2O
- Maximum Diameter (Fan or Blower Wheel): 20.5 to 90.75 inch
- Applications / Use: Air Handling Units / HVAC
-
Supplier: New York Blower Company (The)
Description: New York Blower Series 30 GI [General Industrial] Fans offer four distinct radial-wheel designs to provide the broadest selection flexibility in the industry for moderately high-pressure applications. Typical uses include dust collection, pneumatic-conveying, scrubber exhaust,
- Air Flow Rate: 0 to 95,000 SCFM
- Static Pressure: 406.7871674924572 to 438.7871674924572 in H2O
- Media Temperature: 1,000 F
- Maximum Diameter (Fan or Blower Wheel): 14 to 85 inch
-
Supplier: Twin City Fan & Blower
Description: Application The HRT Radial Tip Fan is designed for applications involving large volumes of gas streams at moderate to high pressures. This unit can accommodate clean or dirty airstreams and is widely used to exhaust gases from bag-type collectors, precipitators, scrubbers, cyclones and
- Air Flow Rate: 6,060 to 254,700 SCFM
- Static Pressure: 438.7871674924572 in H2O
- Maximum Diameter (Fan or Blower Wheel): 27 to 80.75 inch
- Applications / Use: Air Handling Units / HVAC
-
Supplier: EBARA Technologies, Inc.
Description: EBARA's GDC250 point-of-use gas abatement system combines the features and benefits of a patented rolling burner and a high efficiency fan scrubber. The GDC250 is specifically designed for high decomposition abilities for both hydride and PFC (perfluorocompound) gases used in
- Scrubber Type: Skid / Base Plate Mounted
- Orientation: Vertical
-
Supplier: Fisher-Klosterman
Description: The Fisher-Klosterman MPS Multi-Purpose Scrubber has a long and successful track record in many industrial applications. The scrubber is able to effectively cool gas streams, collect particulate, and absorb gaseous pollutants in a single package. The inlet section, which can include a
-
Supplier: Verantis
Description: Available in 7 standard sizes from 500 to 7,000 CFM. Greater than 90-95% removal for soluble/reactive gases. Completely preassembled including a control panel and automation. Includes a top-mounted exhaust fan. Fabricated of lightweight, corrosion-resistant polypropylene. Special gas sparger
- Airflow: 500 to 7,000 SCFM
- Efficiency: 99 %
- Features: Other Filter Type
- Filter Type: Packed Bed / Column
-
Supplier: Branch Environmental Solutions
Description: trace quantities such as removing odors including Hydrogen Sulfide. This type of scrubber can also be used for cooling gas, aeration and any other application where transferring from a gas to a liquid is required. Branch scrubbers are custom designed to fit your specific application.
- Airflow: 50,008.05 SCFM
- Pollutants Scrubbed: Caustic, Chlorine Gas
- Filter Type: Packed Bed / Column
- Process Type: Wet
-
Supplier: Spraying Systems Co.
Description: Common Applications Cooling and quenching Product washing Water cooling Air and gas washers Scrubbers Liquor washers Dust control Fire protection
- Maximum Pressure: 10 to 500 psi
- Maximum Flow: 2.31 to 16.33416664540926 GPH
- Material: Brass
- Media: Chemicals, Water
-
Supplier: Twin City Fan & Blower
Description: control, fluid bed aeration, glass blowing, textile fiber stripping, combustion air, gas boosting, high pressure industrial-process systems and scrubber exhaust.
- Air Flow Rate: 550 to 18,000 SCFM
- Static Pressure: 586.7871674924571 in H2O
- Maximum Diameter (Fan or Blower Wheel): 19.63 to 58.94 inch
- Environment: Clean Air / Gas
-
Supplier: Twin City Fan & Blower
Description: pollution control, fluid bed aeration, glass blowing, textile fiber stripping, combustion air, gas boosting, high pressure industrial-process systems and scrubber exhaust.
- Air Flow Rate: 300 to 20,000 SCFM
- Static Pressure: 566.7871674924572 in H2O
- Maximum Diameter (Fan or Blower Wheel): 19.63 to 58.94 inch
- Environment: Clean Air / Gas
-
Supplier: AMETEK Specialty Motors
Description: AMETEK Floorecare & Specialty Motors manufactures a wide range of Bypass motors for the commercial floorcare, central vacuum, commercial and industrial applications. In Bypass motors the work is independant from the cooling air. A separate fan is used to direct cooling air over the armature
- Design: Axial
- Product Form: Bare (No Motor, Controls)
-
Supplier: SAE International
Description: 1 Inside a paint booth to spray paint on vehicle bodies, bumpers, and other parts (hereinafter referred to as "works"), air whose temperature and humidity are controlled by air-conditioner is supplied by blower fans through filters. Dust-eliminated and regulated air flow is sent downward from
-
Supplier: Henkel Corporation - Industrial
Description: sliding abrasion up to temperatures of +450F (232C). Recommended for protecting scrubbers, cyclones, dust collectors, and fan housings. It will not sag or shrink, and cures to ceramic hardness. Heat resistant Protects against sliding abrasion Can rebuild and repair Will not sag or
- Operating / Use Temperature: 450 F
- Substrate: Metal
- Industry: OEM / Industrial
- Form: Transfer Tape
-
Dust Collectors and Dust Collector Filters - Waste Gas Treatment Electrostatic Dust Collector -- EDCSupplier: DAS Environmental Expert GmbH
Description: waste gases up to 90 m³/h as they accrue, for example, in solar cell manufacturing. The dust collector reduces particle emissions of even the finest particles up to 99.9 %. Operating Principle of the EDC Product Line The waste gases are introduced in a pre-scrubber and following in a tank
- Separation / Filtration System: Electrostatic Precipitators
-
Supplier: HiTemp Technology Corporation
Description: orientation and process requirements. Options include extended stacks, scrubbers, fans, and controls designed to operate with existing plant systems.
- Process Temperature: 1,800 C
- Heat Source: Combustion, Natural Gas
- Configuration: Walk-in / Truck-in
-
Supplier: Goulds Water Technology, a xylem brand
Description: Commercial 316L Stainless Steel End Suction Centrifugal Pumps G&L Series NPE Applications: Water circulation Booster service Liquid transfer Spray system Chillers Washing/cleaning systems Injection molding cooling Reverse osmosis Air scrubbers Heat exchangers Filtration systems Jockey pumps
- Pump Type: Centrifugal Pumps
- Features: Water Pumps
-
Supplier: Hartzell Air Movement
Description: special construction. Common processes which use the Turbo Pressure Blower include: combustion air for burners and boilers; high-pressure cooling air; air pollution control scrubbers; air slides; air turns; water treatment; converting; industrial incinerators; blow-off air knives; soil vapor
- Static Pressure: 0 to 25 in H2O
- Maximum Diameter (Fan or Blower Wheel): 14 to 25 inch
- Material of Construction: Aluminum, Stainless Steel, Steel
- Design: Centrifugal
-
Supplier: SAE International
Description: types, specifically sweepers and scrubbers, covered by SAE J2130 have been added, and other work machine types covered by SAE J1116 may be added with appropriate cycle descriptions and machine preparation. The recommended test procedures include conventional integrating sound pressure level
-
Supplier: SAE International
Description: types, specifically sweepers and scrubbers, covered by SAE J2130 have been added, and other work machine types covered by SAE J1116 may be added with appropriate cycle descriptions and machine preparation. The recommended test procedures include conventional integrating sound pressure level
-
Supplier: Goulds Water Technology, a xylem brand
Description: Commercial Open Impeller All Stainless Steel End Suction Pumps G&L Series NPO Applications: Dishwashers Bottle and glass washers Commercial laundry systems Parts washers Machine tool coolant Liquid transfer Water Circulation Spray System Chillers Washing/Cleaning Systems Air Scrubbers
- Pump Type: Centrifugal Pumps
- Features: Water Pumps
-
Supplier: ProVent LLC
Description: baths. The cleaned air is then dried by forceful impingement against a series of moisture separators. No nozzles, pumps or piping is required. Uni-Wash Wet Booths are available in a wide variety of volumes and bench sizes. These units ship complete with an integral AMCA rated backward curved
- Airflow: 4,000 to 15,000 SCFM
- Collector Type: Collection Booth
- Applications: Metalworking Chips / Fluids
- Process: Wet
Find Suppliers by Category Top
Featured Products Top
-
. The UW-4 Scrubber gained fast acceptance in these applications because it has no small openings to cause clogging. And its wet fan keeps maintenance to a minimum. Twenty-five out of the last thirty major pelletizing plants built use Ducon (read more)
Browse Scrubbers Datasheets for Ducon Environmental Systems -
Centrifugal wet Scrubber is particularly suited for applications involving heavy dust loads and large particulate.Wet Scrubber UW-3 Type UW-3 This Ducon industrial wet scrubber is compact with built-in wet fan and features dust collection efficiency over 99.9% in minimum space with low (read more)
Browse Scrubbers Datasheets for Ducon Environmental Systems -
Scrubber tail gas treatment systems are specialized equipment designed to remove pollutants and harmful gases from industrial exhaust streams, ensuring compliance with environmental regulations and improving air quality. These systems are critical in industries such as chemical manufacturing (read more)
Browse Pressure Regulators Datasheets for Shenzhen Jewellok Technology Co., Ltd. -
Centrifugal wet Scrubber is particularly suited for applications involving heavy dust loads and large particulate.Wet Scrubber UW-3 Type UW-3 This Ducon industrial wet scrubber is compact with built-in wet fan and features dust collection efficiency over 99.9% in minimum space with low (read more)
Browse Baghouses and Baghouse Filters Datasheets for Ducon Environmental Systems -
New York Blower Compact GI [General Industrial] Fans are designed for low-capacity, low-pressure industrial processes such as dust collection, grinding-booth exhaust, scrubber exhaust, food, drying ovens, and paper-trim systems. Compact GI's feature a choice of aluminum or nickel aluminum bronze (read more)
Browse Datasheets for New York Blower Company (The) -
following maintenance schedule, assuming average system conditions and use. Fan filter should be cleaned by blowing out the filter monthly. The pollution scrubber/converter and secondary scrubber media should be replaced yearly (read more)
Browse Gas Generation Equipment Datasheets for Environics, Inc.
Conduct Research Top
-
Crossflow Scrubber and Air Filtration Pilot System
pilot to treat up to 2,500 CFM. In either situation, the pilot lowers risk and improves predictability of project outcome. The unit is supplied in three sections-the main housing, the pump skid, with integral control panel, and the Fan/stack assembly. Assembly and start-up can take place in less
More Information Top
-
Development and Testing of Industrial Scale Coal Fired Combustion System, Phase 3
One final note is that the scrubber fan motor slowed down periodically.
-
http://wiredspace.wits.ac.za/bitstream/handle/10539/7314/Ernest%20Ferreira%20-%2031%20March%202009.pdf?sequence=1
divert contaminated air from the coal face to the scrubber fan system and finally to the return airways.
-
Federal Register > Tuesday, July 8, 2003 > [68 FR 40655] Recent Posting to the Applicability Determination Index (ADI) Database System of Agency Applicability ...
Q: Will EPA allow the monitoring of an alternate parameter, scrubber fan amperage, in lieu of measuring gas scrubber inlet gas flow rate as required in 40 CFR 63.453(c)(2)?
-
Advanced in-duct sorbent injection for SO{sub 2} control. Topical report No. 2, Subtask 2.2: Design optimization
… Utilizations Based on Gas Analyzers Comparison of EPA Method 6 and Flue Gas Analyzers: In-Duct SO, Removal in Test 11A Schematic of First Generation Contactor Humidification Tests Showing Similar Results with and with- out the Scrubber Fan Effect of Atomizing Air …
-
Laboratory Scale Electrostatically Assisted Wet Scrubber for Controlling Dust in Livestock Buildings
Scrubber Fan Spray Nozzle Charge (nC) [a] OFF OFF +0.13 ON OFF +0.16 Air only without charging +0.38 Air only with charging (negative) -0.41 Water spray without charging +0.15 Water spray with charging (negative) -114 [a] Measurements …
-
http://krex.k-state.edu/dspace/bitstream/handle/2097/2754/Erickson.pdf?sequence=1
Scrubber Fan .
-
http://krex.k-state.edu/dspace/bitstream/handle/2097/275/EmadAlmuhanna2007.pdf?sequence=1
Scrubber fan .
-
An investigation of the operating parameters of a low energy wet scrubber for fine particulates
The residence time in the spray zone could then be con- trolled by the additional fan while the scrubber fan speed would be varied independently.
-
Advanced in-duct sorbent injection for SO{sub 2} control. Final technical report
The Waterloo scrubber fan was'not required t o achieve adequate humidification of the flue gas as long as sufficient water droplet surface area was maintained.
-
The demonstration of an advanced cyclone coal combustor, with internal sulfur, nitrogen, and ash control for the conversion of a 23 MMBtu/hour oil fired boiler...
Reduction in measured S02 at the scrubber fan stack, as % of total S.