Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: WAGO
Description: Split-core current transformer; Primary rated current: 250 A; Secondary rated current: 1 A; Accuracy class: 1
- Primary current (Ratio) Range: 250 amps
- Secondary Current (Ratio) Range: 1 amps
- Frequency Range: 0.05 to 0.06 kHz
- Accuracy: 1 % F.S.
-
Supplier: CARLO GAVAZZI Automation Components
Description: Split-core current transformer with bus-bar mounting facility. Rated primary currents from 150 A to 1000 A. Bus-bar type split core current transformer Class 1 accuracy Currents from 150 A to 1000 A Up to 6 Bus-bar isolated fixing
- Primary current (Ratio) Range: 150 to 1,000 amps
- Secondary Current (Ratio) Range: 1 to 5 amps
- Burden: 1.5 to 15 VA
- Insulation Voltage: 3,000 volts
-
Supplier: Sifam Tinsley UK
Description: OMEGA 10 (Split Core CT’s) Omega series split core transformers offer a cost effective and efficient method by which the current can be measured without the need to break the conductor, thereby reducing installation and commissioning time. Features •
- Primary current (Ratio) Range: 100 to 5,000 amps
- Burden: 1 to 45 VA
- Operating Temperature: 20 to 70 C
- Transformer Category: Current Transformer
-
-
Supplier: Hoyt Electrical Instrument Works, Inc.
Description: Conforms to UL 1244, ANSI C57.13 and applicable IEC standards. Frequency 50 - 400 HZ. Insulation Class 0.6 KV BIL 10 KV Leads are 16 AWG UL 1015 PVC, 105C Thermal Rating Factor is 1.33 @ 30C Secondary is available with 1A rating. Other primary current ratings, up to 400A are available.
- Primary current (Ratio) Range: 300 to 2,000 amps
- Secondary Current (Ratio) Range: 5 amps
- Burden: 1 to 15 VA
- Frequency Range: 0.05 to 0.4 kHz
-
Supplier: Hoyt Electrical Instrument Works, Inc.
Description: Conforms to UL 1244, ANSI C57.13 and applicable IEC standards. Frequency 50 - 400 HZ. Insulation Class 0.6 KV BIL 10 KV Leads are 16 AWG UL 1015 PVC, 105C Thermal Rating Factor is 1.33 @ 30C Secondary is available with 1A rating. Other primary current ratings, up to 400A are available.
- Primary current (Ratio) Range: 100 to 400 amps
- Secondary Current (Ratio) Range: 5 amps
- Burden: 0.8 to 5 VA
- Frequency Range: 0.05 to 0.4 kHz
-
Description: For indoor use; Applicable busbar: 20*30-80*160mm; Applicable primary current: 100-3000A; Applicable secondary current: 5A/1A; Applicable for secondary heavy loads; Meet higher accuracy requirements. Voltage level: 0.66/0.72KV; Withstand voltage level: 3KV/1mA/1Min; Rated frequency:
- Primary current (Ratio) Range: 100 to 3,000 amps
- Secondary Current (Ratio) Range: 1 to 5 amps
- Frequency Range: 0.05 to 0.06 kHz
- Accuracy: 3 to 0.5 % F.S.
-
Supplier: Newark, An Avnet Company
Description: SPLIT-CORE CURRENT TRANSFORMER; PRIMARY RATED CURRENT: 500 A; SECONDARY RATED CURRENT: 5 A; RATED POWER: 0.5 VA; ACCURACY CLASS: 1
-
Description: For outdoor use, Level of protection IP67; Applicable cable specifications: φ20-80mm; Applicable primary current: 100-3000A; Applicable secondary current: 5A/1A; Applicable for cable for secondary connection, length customized. Voltage level: 0.66/0.72KV; Withstand voltage level:
- Primary current (Ratio) Range: 100 to 3,000 amps
- Secondary Current (Ratio) Range: 1 to 5 amps
- Frequency Range: 0.05 to 0.06 kHz
- Accuracy: 3 to 0.5 % F.S.
-
Supplier: Newark, An Avnet Company
Description: CURRENT TRANSFORMER SPLIT CORE 700: 5A
-
Supplier: Newark, An Avnet Company
Description: CURRENT TRANSFORMER SPLIT CORE 1250: 5A
-
Supplier: Newark, An Avnet Company
Description: CURRENT TRANSFORMER SPLIT CORE 300:5A
-
Description: For indoor use; Applicable cable specifications: p24mm; Applicable primary current: 50-200A; Applicable for secondary output: mA or mV optional; Nylon housing,UL94-V0 rated; Applicable for wire output,black and white double-wire, black and white stranded wire and sheathed wire optional,
- Primary current (Ratio) Range: 50 to 200 amps
- Frequency Range: 0.05 to 0.06 kHz
- Accuracy: 1 to 0.5 % F.S.
- Operating Temperature: -20 to 55 C
-
Supplier: Beckhoff Automation LLC
Description: The SCT4xxx differential current transformers were designed for detecting differential currents (earth fault currents) type A. A differential current measurement can already detect very low error currents as well as various leakage currents.
- Category: Power / Power System / Distribution Transformer
-
Supplier: Hoyt Electrical Instrument Works, Inc.
Description: Split core transformer with a standard 5-amp secondary. Others available. Terminals are brass No. 10-32 UNC. All models are fully encapsulated for indoor/outdoor applications, additional ratios available with a removable cover and optional mounting brackets. Current ratio
- Primary current (Ratio) Range: 500 to 6,000 amps
- Secondary Current (Ratio) Range: 5 amps
- Burden: 5 to 35 VA
- Insulation Voltage: 600 to 10,000 volts
-
Supplier: Radwell International
Description: CURRENT TRANSFORMER 1200AMP SPLIT CORE. FREE 2 YEAR RADWELL WARRANTY
- Transformer Category: Current Transformer
-
Supplier: Enercorp Instruments Ltd.
Description: AC Split Core Current Transducers Series SC100 converts a monitored AC current to a proportional DC voltage of 0 to 5 Volts. AC Split Core Current Transducers Series SC100 are used to monitor motors, pumps, conveyors, machine tools and any electrical
-
Supplier: Allied Electronics, Inc.
Description: These split-core current transformers (CTs) from Continental Control Systems offer an easy, safe, and inexpensive method for monitoring electrical energy usage. deal for retrofit applications, the split core makes it possible to attach the CT without
-
Supplier: DigiKey
Description: SPLIT-CORE CURRENT TRANSFORMER;
- Operating Frequency Range: 50 to 2,000 Hz
- Features: Bulk Pack, Other
- Other Transformer Types / Applications: Current Sense Transformer
- Category: Signal / RF Transformer
-
Supplier: TE Connectivity
Description: Characteristics Class 3 Burden Rating (VAMP) : .1 Output Current (AMP) : 1 Industry Standards Compatible With Agency/Standards Products : UL Product Type Features Current Transformer Type : Minature Split Core Voltage Application Type : AC (Current
- Secondary Current (Ratio) Range: 1 amps
- Burden: 0.1 VA
- Transformer Category: Current Transformer
- Type / Applications: Split Core
-
Supplier: ODG (Origin Data Global)
Description: SPLIT-CORE CURRENT TRANSFORMER;
- Features: Other
- Category: Signal / RF Transformer
-
Supplier: Galco Industrial Electronics
Description: Split Core Current Transducer With
- Category: Power / Power System / Distribution Transformer
-
Supplier: Galco Industrial Electronics
Description: Current Transformer,Split Core,
- Category: Power / Power System / Distribution Transformer
-
Supplier: SOCOMEC
Description: SOCOMEC current transformers deliver to the secondary a standard current proportional to the primary current and adapted to the rating of the associated device. They are equipped as standard with removable terminal covers and double terminals allowing the secondary to be
- Primary current (Ratio) Range: 5 to 5,000 amps
- Secondary Current (Ratio) Range: 5 amps
- Burden: 1 to 30 VA
- Type / Applications: Bar, Electronics Applications, Split Core, Wound Primary
-
Supplier: Win Source Electronics
Description: Win Source Part Number: 1051452-C/CT-0306 Category: Transformers>Current Sense Transformers Series: C/CT Type: Non-Invasive (Split Core) Termination Style: Wire Leads with Connector Package: Bulk Height - Seated (Max): 1.114" (28.30mm) Standard Package: 48
- Category: Signal / RF Transformer
-
Supplier: Beckhoff Automation LLC
Description: signals, all instrument transformers can easily be connected via patch cable without short-circuiting terminals and they also have electronic nameplates that make manual configuration of the current transformer ratios unnecessary. The EL3475 EtherCAT Terminal can automatically
- Category: Power / Power System / Distribution Transformer
-
Supplier: Beckhoff Automation LLC
Description: signals, all instrument transformers can easily be connected via patch cable without short-circuiting terminals and they also have electronic nameplates that make manual configuration of the current transformer ratios unnecessary. The EL3475 EtherCAT Terminal can automatically
- Category: Power / Power System / Distribution Transformer
-
Supplier: Beckhoff Automation LLC
Description: signals, all instrument transformers can easily be connected via patch cable without short-circuiting terminals and they also have electronic nameplates that make manual configuration of the current transformer ratios unnecessary. The EL3475 EtherCAT Terminal can automatically
- Category: Power / Power System / Distribution Transformer
-
Supplier: Allen-Bradley / Rockwell Automation
Description: Bulletin 1411 - Current Tranformer, 2x3.5" Inner Rectangle
- Transformer Category: Current Transformer
-
Supplier: Allen-Bradley / Rockwell Automation
Description: Bulletin 1411 - Current Tranformer, 2x5.5" Inner Rectangle
- Transformer Category: Current Transformer
-
Supplier: Allen-Bradley / Rockwell Automation
Description: Bulletin 1411 - Current Tranformer, 2x5.5" Inner Rectangle
- Transformer Category: Current Transformer
-
Supplier: Allen-Bradley / Rockwell Automation
Description: Bulletin 1411 - Current Tranformer, 4.5x4.5" Inner Square
- Transformer Category: Current Transformer
-
Supplier: Radwell International
Description: DISCONTINUED BY MANUFACTURER, CURRENT TRANSFORMER, SPLIT-CORE. FREE 2 YEAR RADWELL WARRANTY
- Category: Power / Power System / Distribution Transformer
Find Suppliers by Category Top
Featured Products Top
-
The creative thinkers of Triad Magnetics can offer powerful custom current transformers to meet you specifications. Each product is backed by the industry's most resourceful and organized magnetic supplier organization.
(read more)
Browse Datasheets for Triad Magnetics -
The creative thinkers of Triad Magnetics can offer powerful custom Current Sense Transformers to meet you specifications. Each product is backed by the industry's most resourceful and organized magnetic supplier organization.
(read more)
Browse Current Sense Transformers Datasheets for Triad Magnetics -
Sensed current up to 40 Amps For use between 400 Hz to 1 MHz Very low primary resistance AEC-Q200 Grade 1 (−40°C to +125°C) Meets Reinforced Insulation per UL 60950-1. 4000 Vrms, one minute isolation (hipot) winding to winding Ro (read more)
Browse Current Sense Transformers Datasheets for Coilcraft, Inc. -
Current sense transformers “transform” AC electrical currents from larger-current values into smaller currents that are better suited for instruments, protective relays, and control circuits. This is achieved by developing a current in the secondary winding that is proportional (read more)
Browse Current Sense Transformers Datasheets for Triad Magnetics -
Design Considerations for Current Sense Transformers Current sense transformers are instrument transformers designed to detect (i.e., sense) electrical current and convert (i.e., transform (read more)
Browse Current Sense Transformers Datasheets for Triad Magnetics -
Transformer inrush current is the temporary surge of current that occurs when a transformer is first switched on. It can be several times higher than the normal operating current, even when the transformer is working correctly. (read more)
Browse Three Phase Transformers Datasheets for Majestic Transformer Co. -
Current Sense Transformers As their name implies, current sense transformers “sense,” or detect, an electrical current (typically AC), accurately measure it based on Ohm’s Law, and (read more)
Browse Current Sense Transformers Datasheets for Triad Magnetics -
onsemi's NCV84120 is a fully protected single-channel high-side driver that can be used to switch various loads, such as bulbs, solenoids, and other actuators. The device incorporates advanced protection features such as active inrush current management, overtemperature shutdown (read more)
Browse Power Transformers Datasheets for DigiKey -
To find the best inductors, don't limit the search to a specific ripple current. Simply click Find Inductors and skip step 2 to see a full list of possible inductor choices along with the associated ripple current and ac loss estimate, all driven from real inductor characterization data. To (read more)
Browse Transformers Datasheets for Coilcraft, Inc. -
WAGO's compact split-core current transformers are ideal for retrofitting existing systems. They are perfect for applications in which the current path must not be disrupted. The transformer's accuracy permits extremely precise current measurements. The split-core current transformers are (read more)
Browse Signal Conditioners Datasheets for WAGO
Conduct Research Top
-
Current Transformers
Current transformers (CT's) provide a simple, inexpensive and yet accurate means of sensing current flow in power conductors. They are available in 3 basic configurations: Split Core CT's are available for measuring currents from 100 to 5000 amps, with windows in varying sizes from 1" by 2" to 13
-
Current Transformer Measurements
The Current Transformer (CT) is used to sense AC current in single-phase or three-phase mains circuits. The CT typically has a 1A or 5A AC secondary that connects to a current, power or energy meter. This allows the meter to be located away from the mains wiring. CTs are available in a variety
More Information Top
-
split core current transformer - offers from split core current transformer manufacturers, suppliers, exporters & wholesalers
split core current transformer .
-
How to choose and implement current sensors | AltEnergyMag
New materials and technologies equip advanced split core current transformers for immediate retrofitting of high-performance and cost-effective condition monitoring, power metering and facility supervision systems.
-
Split-core Current Transformer and Transducer from Fusign Electronics Co.,Ltd , China
Split core current transformer with interleaved joint and hinge structure .
-
Split Core Current Transformer from J & D Electronics Co., Ltd., Korea
There are 99 split core current transformer from 41 suppliers on EC21.com .
-
current transformer - offers from buyers, importers, purchasers, resellers & dropshippers
current transformer - Buy Split Core Current Transformer .
-
RCT Current Transformer from Jiangyin Current Transformer Factory, China
Split core current transformer 0.33V output .
-
Evaporator Core from The Palm Co., Ltd., Korea
Split Core Current Transformer .
-
meters transformer - offers from meters transformer manufacturers, suppliers, exporters & wholesalers
[ Related Keywords : split core current transformers , ac current transformer ] .
-
cable bobbin - offers from cable bobbin manufacturers, suppliers, exporters & wholesalers
[ Related Keywords : split core ct, split core current transformer , split cor cts, split core current transformers ] .
-
35KV Oil Transformer from Zhejiang JSB Transformer Co., Ltd, China
Split Core Current Transformer .
Indicates content that may require registration and/or purchase.