Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Badger Meter
Description: The CV Venturi Flow Meter is a differential pressure element designed to accurately measure the flow of liquids and gases by forcing the flow into a smaller diameter section of pipe, then measuring the pressure differences between the unrestricted flow and
- Pipe Diameter: 2 to 16 inch
- Liquid Volumetric Flow Rate: 3 to 20,000 GPM
- Operating Pressure: 0 psi
- Mass Flow Rate: 0.006615 to 44.1 lbs/min
-
Supplier: Badger Meter
Description: The Venturi Model SSL (Classical Venturi Design) is a Hershel/Classical design differential pressure flow device. The Venturi flow meter restricts the flow at its throat, increasing the velocity of the fluid, and measures the pressure difference of
- Pipe Diameter: 0.5 to 60 inch
- Liquid Volumetric Flow Rate: 0.25 to 825,000 GPM
- Operating Pressure: 0 psi
- Mass Flow Rate: 0.00055125 to 1,819.125 lbs/min
-
Supplier: Badger Meter
Description: The Venturi Model SSM is a Venturi Nozzle design differential pressure flow device. The Preso Hydraulic pure static design utilizes the proven classical ASME and ISO standards for highest accuracy, predictability and repeatability. The flow conditioning generated by the
- Pipe Diameter: 0.5 to 60 inch
- Liquid Volumetric Flow Rate: 0.25 to 825,000 GPM
- Operating Pressure: 0 psi
- Mass Flow Rate: 0.00055125 to 1,819.125 lbs/min
-
-
Supplier: Badger Meter
Description: The Venturi Model VISSM (Insert Type Hydraulic Venturi Design) is a Hydraulic design differential pressure flow device. The insertion style meter adds only the thickness of the meter center flange to the overall length of the pipe. The Venturi flow
- Pipe Diameter: 3 to 36 inch
- Liquid Volumetric Flow Rate: 0.25 to 220,000 GPM
- Operating Pressure: 0 psi
- Mass Flow Rate: 0.00055125 to 485.1 lbs/min
-
Supplier: Armstrong International
Description: Accelabar is a new and unique flow meter that combines two differential pressure technologies to produce high accuracy and low velocity flow rates at turndowns tested up to 65:1 with no straight run requirements. The Accelabar consists of a unique toroidal nozzle design and a
- Gas Volumetric Flow Rate: 16.6666666666667 to 1,000 SCFM
- Operating Pressure: 50 psi
- Media Temperature: 70 F
- Media Temperature Range: 70 F
-
Supplier: Accuris
Description: Standard Method of FLOW MEASUREMENT OF WATER BY THE VENTURI METER TUBE
-
Supplier: Daniel Measurement and Control Inc.
Description: Classical Venturi is a head pressure device that consists of a convergent cone section, cylindrical bore, and a divergent cone section. The cylindrical bore restricts the fluid flow resulting in a pressure drop. This differential pressure relates to the flow rate by applying
- Features: Differential Pressure Meter, In-line
- End Fittings: Flanged
- Process Media Type: Gas, Liquid, Steam
- Meter Technology: Venturi Tube
-
Supplier: ABB Measurement & Analytics
Description: Venturi tubes are available for line sizes from 50 mm to 1200 mm (2 to 48in) and can measure a wide range of relatively clean liquids and gases. The units are designed to ISO5167-1:2003 and have a substantial overall length, being typically 5D long (D = nominal pipe size). There are two
- Pipe Diameter: 1 to 48 inch
- Features: Differential Pressure Meter, In-line
- End Fittings: Flanged
- Process Media Type: Gas, Liquid
-
Supplier: ASTM International
Description: Method for Flow Measurement of Industrial Water and Industrial Waste Water by the Venturi Meter Tube (Withdrawn 1981)
-
Supplier: Accuris
Description: Measurement of fluid flow in closed conduits, Part 1.5: Pressure differential methods - Measurement using orifice plates, nozzles or Venturi meters - Pulsating flow, in particular sinusoidal or square wave intermittent periodic-type fluctuations
-
Supplier: Orange Research, Inc.
Description: option) >> Flow (with indicator option) A 4-20 mA (two wire) output is available for loop-powered installations, which offers the user the most savings in installation. A 0-5 VDC (three or four wire) output also is available as standard. The input voltage is 9-35 VDC. The transmitters are
- Liquid Volumetric Flow Rate: 0 to 10 GPM
- Operating Pressure: 0 to 1,000 psi
- Electrical Output: Analog Current, Analog Voltage
- Features: Analog Display, Volumetric Flow Meter
-
Supplier: Victaulic Co. of America
Description: VENTURI TYPE +/- 1 PERCENT ACCURACY 12 INCH NOMINAL SIZE 12 NOMINAL SIZE - DECIMAL 12 NOMINAL SIZE - FRACTIONAL CARBON STEEL BODY MATERIAL 250 PSI WATER AT 230 DEG F PRESSURE RATING 12 INCH IPS GROOVED X 12 INCH IPS GROOVED END CONNECTION 12 INCH END TO END DISTANCE APPROXIMATE WEIGHT 60 LB
- Pipe Diameter: 12 inch
- Operating Pressure: 250 psi
- Meter Technology: Venturi Tube
-
Supplier: SAE International
Description: venturi meter results in a flow restriction and significant pressure drop in the dilution air pipe. An ultrasonic flow meter for a similar dilution air volume offers little flow restriction and negligible pressure drop in the air duct. In this investigation,
-
Supplier: Azbil Corporation
Description: can be applied to a wide-range applications. Usable as differential pressure flowmeters for measuring gas, steam, and liquid. These products with mass flow sensors provide gas flow measurement and control that is featured by quick response, low pressure drops, and wide measurement
- Features: Differential Pressure Meter, Velocity Meter
- End Fittings: Flanged
- Process Media Type: Gas, Liquid, Steam
- Meter Technology: Venturi Tube, Vortex (Shedding) Meter
-
Supplier: Orange Research, Inc.
Description: Differential Pressure Flowmeters Our new, fully integrated differential pressure flowmeters are compact and rugged, with directly connected, large throated, non-clogging flow nozzles. This unique design reduces size and cost while minimizing errors and leaks. Simply select the flow
- Pipe Diameter: 0.5 to 2 inch
- Media Temperature Range: -20 to 200 F
- Liquid Volumetric Flow Rate: 0 to 60 GPM
- Operating Pressure: 100 to 500 psi
-
Supplier: CSA Group
Description: possible; the total mass flow rate may be known (this is more likely in a wet-steam flow than in a natural gas/liquid flow); in a wet-steam flow a throttling calorimeter can be used. Wet-gas measurement using Venturi tubes or orifice plates is covered in ISO/TR
-
Description: possible; the total mass flow rate may be known (this is more likely in a wet-steam flow than in a natural gas/liquid flow); in a wet-steam flow a throttling calorimeter can be used. Wet-gas measurement using Venturi tubes or orifice plates is covered in ISO/TR
-
Supplier: National Oilwell Varco
Description: Mud Hoppers The low-pressure mud hopper was produced in the 1940's. National Oilwell Varco's Jet-Venturi Mud Hopper was introduced in the early 1950's and continues to be the hopper of choice today. Properly engineered hoppers ensure the highest discharge pressures, solid addition rates and
- Width/Diameter: 4 to 6 inch
- Type: Metering
-
Supplier: HORIBA Instruments, Inc.
Description: the new MDLT-ONE is very compact and offers faster response by the use of high precision venturi flow meters and a piezo actuated valve. *HEPA: High Efficiency Particulate Air Small package Heated filter system and flow controllers installed in a single rack. Swivel
-
Supplier: ThermOmegaTech®
Description: temperature set point be exceeded and will completely shut down at 15°F above set point or if cold water flow is interrupted. The thermal element will not re-open until cold water flow is restored. Conventional washdown stations, utilizing old spool and diaphragm technology that rely
- Dispense Rate: 65.15151515151516 L/min
- Application: Cleaners / Sanitizers, Food / Beverage, Water
- Dispensed From: Gun Handle
- Dispensing Equipment Type: Meter, Mix and Dispense, Mix and Dispense
-
Supplier: HORIBA Instruments, Inc.
Description: the use of a venturi flow meter which enables reliable proportional sampling and accurate exhaust gas flow measurement under transient flow conditions. Combine the GAS unit and PM unit to perform certification tests on heavy duty and non-road vehicles. EPA CFR part
-
Supplier: Reznor
Description: furnace has a patented Reznor® Thermocore® aluminized steel heat exchanger with venturi-design tubes. The die-formed burners are of aluminized steel and include flared ports with a stainless steel insert. Standard features include a spark-ignited intermittent pilot and a single stage 24-volt
- AC Voltage Required: 120 volts
- kWatts: 29.31 kW
- Height: 38.53125 inch
- Width: 30.9375 inch
-
Supplier: Reznor
Description: from 75,000 through 400,000BTUH gas input. They are designed for use as heating components in heating, heating/cooling, or makeup air systems and require a separate blower system for air delivery. The furnace has a Reznor® Thermocore® aluminized steel heat exchanger with venturi-design tubes.
- AC Voltage Required: 115 to 230 volts
- kWatts: 88 kW
- Height: 36 inch
- Width: 34 inch
-
Supplier: ASME
Description: fluid from a tank; vertical rise of a weather balloon; wind drag forces on people; Venturi meter; fluid’s surface shape in a rotating cylindrical tank; range of an aircraft; designing a water clock; water turbine under a dam; centrifugal separation of particles; ideal gas flow
-
Supplier: ASME Standards and Certification
Description: fluid from a tank; vertical rise of a weather balloon; wind drag forces on people; Venturi meter; fluid’s surface shape in a rotating cylindrical tank; range of an aircraft; designing a water clock; water turbine under a dam; centrifugal separation of particles; ideal gas flow
Find Suppliers by Category Top
Featured Products Top
-
needed is less than a 16-inch diameter. As is typical for other meters, whether you choose a V-Cone or a Venturi is wholly dependent upon the needs of your flow project, and what criteria must be met. What works for an offshore platform or a small retrofit project may not work for an industrial (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
pumps, elbows, valves and other devices that negatively affect measurement accuracy. In comparison to traditional instruments such as magnetic and venturi flow meters, the V-Cone's design is inherently more accurate because the flow conditioning function is built-into the basic instrument. The (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
pumps, elbows, valves and other devices that negatively affect measurement accuracy. In comparison to traditional instruments such as magnetic and venturi flow meters, the V-Cone's design is inherently more accurate because the flow conditioning function is built-into the basic instrument. The (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
diameters downstream to eliminate the effects of swirl and other pipeline disturbances caused by pumps, elbows, valves and other devices that negatively affect measurement accuracy. In comparison to traditional instruments such as magnetic and venturi flow meters, the V2's design is inherently (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
straight pipe diameters downstream to eliminate the effects of swirl and other pipeline disturbances caused by pumps, elbows, valves and other devices that negatively affect measurement accuracy. In comparison to traditional instruments such as magnetic and venturi flow meters, the V2's design (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
inspection and replacement of plates. Unlike traditional dP instruments such as orifice plates and venturi tubes, the V-Cone Flow Meter's design is inherently more accurate because the flow conditioning function is built into the design. The meter's centrally located cone interacts with the (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
ability to self-condition flow, the V-Cone Subsea Flow Meter is a real space-saver, eliminating the need for long up/down stream straight pipe runs required by other DP technologies, such as orifice plates and venturi tubes. It can be installed virtually anywhere in a piping system or be easily retrofit (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
V-Cone Subsea Flow Meter reduces the upstream/downstream straight pipe run required Venturi Tubes by up to 70 percent. It only requires 0-1 straight pipe diameters upstream and 0-3 diameters downstream. This reduction in pipe requirements (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
Engineers in search of a reliable solution for wellhead gas flow measurement will find that the flexible Wafer-Cone® Flow Meter from McCrometer provides (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
as magnetic and venturi flow meters, the V-Cone's design is inherently more accurate because the flow conditioning function is built-into the basic instrument. The V-Cone conditions fluid flow to provide a stable flow profile that increases accuracy. It features a centrally-located cone inside a tube (read more)
Browse Flow Meters Datasheets for McCrometer, Inc.
Conduct Research Top
-
Flow Measurement
devices are there to choose from? There are types that create an obstruction in the pipe and measure the differential pressure across this obstruction. This includes the age-old orifice plate and venturi meter. Does your customer really want to pay for this pressure drop for the life
More Information Top
-
An Integrated Solution Enabling Allocation of Heavy Oil in the Peregrino Field
Fluid was passed thru the test pump and then venturi flow meter .
-
Federal Register > Wednesday, July 13, 2005 > [70 FR 40420] Test Procedures for Testing Highway and Nonroad Engines and Omnibus Technical Amendments
For example, for diluted exhaust flow for a full-flow dilution system, we recommend a reference subsonic venturi flow meter with a restrictor valve and a blower to simulate flow rates.
-
Code of Federal Regulations > Title 40 - Protection of Environment > Air Pollution Controls > [40 CFR Part 1065] Engine-Testing Procedures
For example, for diluted exhaust flow for a full-flow dilution system, we recommend a reference subsonic venturi flow meter with a restrictor valve and a blower to simulate flow rates.
-
Pilot Scale Tests Alden/Concepts NREC Turbine
Velocity measurements in the test loop were taken upstream of the Venturi flow meter (Figure 3- 3), just upstream of the treatment fish injection location (Figure 3-3), and just downstream from the control fish injection (slightly upstream from the end of …
-
A first characterization of the quench detection system for ITER
The following four sensors proposed for the ITER coils were analyzed here: (1) optical fiber, (2) co-wound voltage tap, (3) pressure transducer, and (4) Venturi flow meter .
-
http://eprints.maths.ox.ac.uk/12/1/mcburnie.pdf
Instability of stratified two-fluid flow in a Venturi flow meter .
-
IAENG Transactions on Engineering Technologies
Abstract An intelligent flow measurement technique by venturi flow meter using an optimized Artificial Neural Network (ANN) is presented.
Indicates content that may require registration and/or purchase.