Phase Conjugate Laser Optics

Chapter 5.4.2 - Optical architecture of the 500-ns system

5.4.2   Optical architecture of the 500-ns system

The long-pulse laser system is a direct adaptation of the optical architecture used for
the 15-ns MOPA described in the previous section. The primary difference is the
replacement of the Pockels with a permanent-magnet Faraday rotator. This allows
pulses of arbitrary duration, constrained only by peak power requirements in the
SBS phase conjugate mirror, to be amplified. While the 15-ns laser system is a
laboratory development system built with standard components on an optical bench,
an effort was made to package the 500-ns laser system in a compact, engineered


Figure 5.14. Optical layout of the 500-ns phase conjugated laser system. The Pockels cell from Fig. 5.5 has been replaced by a permanent-magnet Faraday rotator, allowing pulses of arbitrary duration to be amplified in the 8-pass zigzag slab amplifier.

 

assembly as illustrated in the optical layout of Fig. 5.14 and the photograph of the
system in Fig. 5.15.

5.4.2.1   Long-pulse multipass polarization switching   The long-pulse
laser is a MOPA design using an SBS phase conjugate mirror. The optical
architecture and beam transport system are based on the design presented for the 15-
ns laser system. The described considerations for relay imaging between gain passes
and to the input aperture of the SBS conjugator are carefully incorporated into this
design. In the previously described 15-ns pulse amplifier, a large-aperture Pockels
cell is used as an active optical switch to isolate the phase conjugated and amplified
output from the input beam train. However, in order to amplify pulses of up to 1 μs
in duration, the Pockels cell switch was replaced with a 45-mm clear-aperture
permanent-magnet Faraday rotator. This results in an eight-pass regenerative
amplifier system with totally passive polarization switching. A schematic diagram of
the amplifier optical design is depicted in Fig. 5.14. The oscillator output is
expanded from a 1-mm beam to a 6-mm beam using a simple two-lens telescope. It
is then amplified by a double-pass through an Nd:YLF preamplifier. After passing
through a 10-mm clear-aperture Faraday isolator, the injection beam is expanded to
a diameter of 30 mm. This beam is then shaped to a 25-mm square by a hard-edged


Figure 5.15. Photograph of the 500-ns laser system, with electro-optics technologist James Wintemute, during final activation and testing.

aperture before entering the amplifier system through polarizing beamsplitter P1. An
anamorphic telescope takes the input from its 25 × 25-mm2 size to the 7 × 120-
mm2 used in the glass amplifier aperture. The input beam enters the regenerative
amplifier ring in p-polarization through polarizing beamsplitter P2 and undergoes
two gain passes. The polarization is then rotated 90o by a quartz rotator and the beam
reflects from the same beam splitter in s-polarization, undergoing two more gain
passes. When the polarization is returned to the original p-state after the second pass
through the rotator, the beam is coupled out through polarizer P3 and directed into
the SBS phase conjugate mirror. The reflected beam from the phase conjugator
retraces the path of the input beam, adding four more gain passes for a total of eight.
The polarization rotation of the 45o Faraday rotator and the 45o quartz rotator cancel
each other in the input direction, but now, in the output direction, they add, resulting
in a full 90o rotation. The amplified beam is therefore reflected by polarizer P1 and
enters the doubler. Since the output beam passes back through the anamorphic input
telescope, the 25 × 25-mm2 beam size is restored before reaching the doubler.

UNLIMITED FREE
ACCESS
TO THE WORLD'S BEST IDEAS

SUBMIT
Already a GlobalSpec user? Log in.

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.

Customize Your GlobalSpec Experience

Category: Lasers
Finish!
Privacy Policy

This is embarrasing...

An error occurred while processing the form. Please try again in a few minutes.