Handbook of Chemical Engineering Calculations, Third Edition

7.6: HEAT LOSS FROM A BURIED LINE

7.6 HEAT LOSS FROM A BURIED LINE

A steam line with a diameter of 12.75 in (0.3239 m) is buried with its center 6 ft (1.829 m) below the surface in soil having an average thermal conductivity of 0.3 Btu/(h)(ft)( F) [0.52 W/(m)(K)]. Calculate the heat loss if the pipe is 200 ft (60.96 m) long, the steam is saturated at a temperature of 320 F (433 K), and the surface of the soil is at a temperature of 40 F (277 K).

Calculation Procedure

1. Select the appropriate heat-transfer equation. The heat loss can be calculated from the equation


where Q is heat loss, k is thermal conductivity of the soil, T 1 is surface temperature of the pipe, T 2 is surface temperature of the soil, and S is a shape factor.

2. Determine the shape factor. Use the equation S=2 ?L/cosh ?1(2 z/D) (when z is much less than L), where L is length, z is distance from ground surface to the center of the pipe, and D is diameter. Now,


For this example, 2 z/ D=2(6)/(12.75/12)=11.294, and cosh ?1(2 z/ D)=ln [11.294+(11.294 2 ?1) 1/2]=3.116. Thus, S=2 ?200/3.116=403.29 ft (122.92 m).

3. Calculate the heat loss. Because the heat-transfer resistance through the soil is much greater than all other resistances to heat transfer, the surface of the...