Automatic Temperature Compensation Refractometers

13 Results
Handheld Digital Refractometer -- PCE-DRB 1
from PCE Instruments / PCE Americas Inc.

PCE-DRB 1 is a handheld digital refractometer used to determine the sugar content / refractive index of liquid in the 0 ... 90 % Brix / 1.3330 ... 1.5177 nD measuring range. This waterproof IP65-rated digital refractometer features automatic temperature compensation (ATC) from +10 ... +40 °C /... [See More]

  • Prism / Light Source & Special Features: Automatic Temperature Compensation; Temp Measurement
  • RI Range: 1,3330 ... 1,5177 nD
  • Measurement Scale: RI; BRIX
  • RI Accuracy: 0.0003 nD
Handheld Digital Refractometer -- PCE-DRB 2
from PCE Instruments / PCE Americas Inc.

PCE-DRB 2 is a handheld digital refractometer used to determine the refractive index and dextran, fructose, glucose, lactose and maltose content (%) of liquid. This IP65-rated digital refractometer features automatic temperature compensation (ATC) from +10 ... +40 °C / +50 ... +104 °F, as... [See More]

  • Prism / Light Source & Special Features: Automatic Temperature Compensation; Temp Measurement
  • RI Range: 1,3330 ... 1,5177 nD
  • Measurement Scale: RI; Content %
  • RI Accuracy: 0.0003 nD
Handheld Digital Refractometer -- PCE-DRS 1
from PCE Instruments / PCE Americas Inc.

PCE-DRS 1 is a handheld digital sodium chloride (NaCl) refractometer used to determine the salinity or salt content (%, ‰), specific gravity (SG) and refractive index (nD) of liquid. This waterproof IP65-rated digital refractometer features automatic temperature compensation (ATC) from +10... [See More]

  • Prism / Light Source & Special Features: Automatic Temperature Compensation; Temp Measurement
  • RI Range: 1.3330 ... 1.3900 nD (Refractive Index)
  • Measurement Scale: RI; Salinity or Salt Content (%, ‰), Specific Gravity (SG)
  • RI Accuracy: 0.0003 nD
Handheld Digital Refractometer -- PCE-DRS 2
from PCE Instruments / PCE Americas Inc.

PCE-DRS 2 is a handheld digital sodium chloride (NaCl) and chlorine (Cl) refractometer used to determine the salinity or salt content ( ‰), chlorine content ( ‰), specific gravity (SG) and refractive index (nD) of liquid. This waterproof IP65-rated digital refractometer features... [See More]

  • Prism / Light Source & Special Features: Automatic Temperature Compensation; Temp Measurement
  • RI Range: 1.3330 ... 1.3530 nD (Refractive Index)
  • Measurement Scale: RI; Salinity or Salt Content (‰), Chlorine Content (‰), Specific Gravity (SG)
  • RI Accuracy: 0.0003 nD
Handheld Digital Refractometer, Beer -- PCE-DRW 1
from PCE Instruments / PCE Americas Inc.

PCE-DRW 1 is a handheld digital refractometer used to determine the sugar content / specific gravity of beer and similar liquids in the 0 ... 50 % Brix / 1.000 ... 1.130 d 20 ⁄20 measuring range. This waterproof IP65-rated digital refractometer features automatic temperature compensation (ATC)... [See More]

  • Prism / Light Source & Special Features: Automatic Temperature Compensation; Temp Measurement
  • RI Range: 1.000 ... 1.130 d 20/20 (Refractive Index)
  • Measurement Scale: RI; BRIX; Specific Gravity (d 20/20)
  • RI Accuracy: 0.001 d 20/20
Handheld Digital Refractometer, Coffee -- PCE-DRP 1
from PCE Instruments / PCE Americas Inc.

PCE-DRP 1 is a handheld digital refractometer used to determine the sugar content / coffee p1 / refractive index of coffee and similar liquids in the 0 ... 50 % Brix / 0 ... 25 coffee p1 / 1.3330 ... 1.4200 nD measuring range. This waterproof IP65-rated digital refractometer features automatic... [See More]

  • Prism / Light Source & Special Features: Automatic Temperature Compensation; Temp Measurement
  • RI Range: 1.3330 ... 1.4200 nD (Refractive Index)
  • Measurement Scale: RI; BRIX; Coffee p1
  • RI Accuracy: 0.0003 nD
Handheld Digital Refractometer, Coffee -- PCE-DRP 2
from PCE Instruments / PCE Americas Inc.

PCE-DRP 2 is a handheld digital refractometer used to determine the sugar content / coffee p2 of coffee and similar liquids in the 0 ... 30 % Brix / 0 ... 25 coffee p2 measuring range. This waterproof IP65-rated digital refractometer features automatic temperature compensation (ATC) from +10 ... +40... [See More]

  • Prism / Light Source & Special Features: Automatic Temperature Compensation; Temp Measurement
  • BRIX Range: 0 ... 30% Brix (Sucrose or Sugar Content)
  • Measurement Scale: RI; BRIX; Coffee p1
  • BRIX Accuracy: ±0.2 % Brix
Handheld Digital Refractometer, Coolants / Batteries / Cleaners -- PCE-DRC 1
from PCE Instruments / PCE Americas Inc.

PCE-DRC 1 is a handheld digital refractometer used to determine the specific gravity (sg) of electrolyte solution batteries as well as the freezing point of propylene or ethylene glycol-based coolants. Maintaining the proper antifreeze concentration in an engine can prevent costly repairs. Thus,... [See More]

  • Prism / Light Source & Special Features: Automatic Temperature Compensation; Temp Measurement
  • Other Range / Accuracy: -50 ... 0°C Coolant or Antifreeze; 1,000 ... 1,500 Specific Gravity (Sg) Battery Acid; -40 ... 0°C
  • Measurement Scale: RI; °C, Specific Gravity (SG)
  • Monitoring: Sample
Handheld Digital Refractometer, Ethylene Glycol / Propylene Glycol -- PCE-DRA 1
from PCE Instruments / PCE Americas Inc.

PCE-DRA 1 is a handheld digital antifreeze refractometer used to determine the percentage or content and freezing point of propylene glycol- and ethylene glycol-based solutions. This waterproof IP65-rated digital refractometer features automatic temperature compensation (ATC) from +10 ... +40 °C... [See More]

  • Prism / Light Source & Special Features: Automatic Temperature Compensation; Temp Measurement
  • Other Range / Accuracy: 0 ... 100 % Ethylene Glycol or Propylene Glycol Content (V / V); -50 ... 0 °C Ethylene Glycol; -60 ... 0 °C Propylene Glycol
  • Measurement Scale: Content (v / v), °C
  • Monitoring: Sample
Semiconductor Liquid Chemical Refractometer -- Vaisala K-PATENTS® PR-23-MS
from Vaisala

For semiconductor liquid chemical processes. A compact refractometer with an ultra-pure modified PTFE flow cell body for semiconductor liquid chemical processes. Connected to the process by a ¼ — 1 inch pillar or flare fitting. Vaisala K-PATENTS ® Semicon Refractometer PR-23-MS has a... [See More]

  • Prism / Light Source & Special Features: Modified PTFE, Prism Gasket Modified PTFE Prism Sapphire, O-ring Kalrez, Adaptor Sapphire; Alarms; Automatic Temperature Compensation; Temp Measurement
  • RI Range: Full measurement range of Refractive Index nD 1.3200–1.5300, which corresponds to 0-100 % by weight. Optional range nD 1.2600–1.4700 for strong HF
  • Measurement Scale: RI
  • Monitoring: Continuous Monitoring
Refractometer -- MT-010ATC
from REED-Direct

Brix% is calibrated to the number of grams of cane sugar contained in 100g of cane sugar solution. When measuring a sugar solution, the Brix% should perfectly match the actual concentration. With solutions of other components, a conversion chart is required. Features automatic temperature... [See More]

  • Prism / Light Source & Special Features: Automatic Temperature Compensation
  • BRIX Range: 0 to 10%
  • Measurement Scale: BRIX
  • BRIX Accuracy: ±0.01%
Semiconductor Liquid Chemical Refractometer -- Vaisala K-PATENTS® PR-33-S
from Vaisala

For semiconductor liquid chemical processes. A compact refractometer with an ultra pure modified PTFE flow cell body for semiconductor liquid chemical processes. Connected to the process by a ¼ — 1 inch pillar or flare fitting. Vaisala K-PATENTS ® Semicon Refractometer PR-33-S... [See More]

  • Prism / Light Source & Special Features: Modified PTFE, Prism Gasket Modified PTFE Prism Sapphire, O-ring Kalrez, Adaptor Sapphire; Alarms; Automatic Temperature Compensation; Temp Measurement
  • RI Range: Full measurement range of Refractive Index nD 1.3200–1.5300, which corresponds to 0-100 % by weight. Optional range nD 1.2600–1.4700 for strong HF
  • Measurement Scale: RI
  • Monitoring: Continuous Monitoring
Refractometer -- MT-110ATC
from REED-Direct

Range: 0 to 100 ppt Na; 1.000 to 1.070 sp.gr. Minor Divs.: 1.0 ppt; 0.001 sp.gr. Accuracy: ±1.0 ppt; ±0.001 sp.gr. [See More]

  • Prism / Light Source & Special Features: Automatic Temperature Compensation
  • Other Range / Accuracy: 0 to 100 ppt NA
  • Measurement Scale: PPT
  • Monitoring: Sample