RTDs Intrinsic Safety Barriers
from PR electronics
Advanced features. The 5131 transmitter can be configured with a standard PC and the Loop Link communications unit. Application. Independent channel jumper selectable inputs for current/voltage or temperature. Current input programmable in range the 0...100 mA and voltage inputs in the range 0...250... [See More]
- Application: RTDs; Thermocouples
- Mounting Options: Din Rail Mounted
- Barrier Type: Galvanic Isolator
- Height: 4.29
from Gems Sensors & Controls
The exceptionally compact design of Gems ™ 65800 Series units saves space and simplifies installation; especially in multiples on a common mounting plate. They provide great economy as well since no explosion-proof enclosures are needed for sensor wiring. Encapsulated construction is... [See More]
- Application: 4-20 mA 2-wire Transmitters; Switches; RTDs; Thermocouples; Strain Gages; Load Cells; Flow Meters; Level Sensors, Pressure Switches
- Mounting Options: Earth-Grounded Rail Mount
- Barrier Type: Zener Barrier
- AC or DC: DC
from PR electronics
Application. Redundancy measurement of temperature by means of two sensors, where the secondary sensor takes over the measurement when a sensor error occurs on the primary sensor. Duplication of the input signal, e.g. from a temperature sensor or an analog process signal to two separate analog... [See More]
- Application: RTDs; Thermocouples
- Mounting Options: Din Rail Mounted; DIN Rail Mounted, Vertically or Horizontally
- Barrier Type: Galvanic Isolator
- Height: 4.29
from Gems Sensors & Controls
For most non-voltage-producing devices located in a hazardous area, a single zener barrier that is negative-earth-grounded can be used for intrinsic safety. Instrumentation that produces an output (signal conditioners) usually requires two barriers, one for each "floating" lead. In this case, select... [See More]
- Application: 4-20 mA 2-wire Transmitters; Switches; RTDs; Thermocouples; Strain Gages; Load Cells; Flow Meters; Level Sensors, Pressure Switches
- Mounting Options: Earth-Grounded Rail Mount
- Barrier Type: Zener Barrier
- AC or DC: DC
from PR electronics
Advanced features. The 5114 transmitter can be configured, with or without a power supply, using the PReset software and the Loop Link communications unit. Application. Jumper selectable inputs for current/voltage or temperature. Programmable current (0...100 mA) and voltage (0...250 VDC) inputs. [See More]
- Application: RTDs; Thermocouples
- Mounting Options: Din Rail Mounted
- Barrier Type: Galvanic Isolator
- Height: 4.29
from PR electronics
Application. Linearized, electronic temperature measurement with RTD or TC sensor. Conversion of linear resistance variation to a standard analog current / voltage signal, i.e. from solenoids and butterfly valves or linear movements with attached potentiometer. Power supply and signal isolator for... [See More]
- Application: RTDs; Thermocouples
- Mounting Options: Din Rail Mounted; DIN Rail Mounted, Vertically or Horizontally
- Barrier Type: Galvanic Isolator
- VOC: 250