Supplier: TE Connectivity
Description: Removable Electrical Characteristics Operating Voltage (VDC) : 32 Switch Main Contact Current Rating (AMP) : 400 Mechanical Attachment Operating Handle Type : Double Wing
- Current Rating: 400 amps
- Operating Voltage: 32 volts
- Poles: 1 Pole
-
Supplier: TE Connectivity
Description: Electrical Characteristics Operating Voltage (VDC) : 32 Switch Main Contact Current Rating (AMP) : 400 Mechanical Attachment Operating Handle Type : Lever
- Current Rating: 400 amps
- Operating Voltage: 32 volts
- Poles: 1 Pole
-
Supplier: TE Connectivity
Description: Electrical Characteristics Operating Voltage (VDC) : 32 Switch Main Contact Current Rating (AMP) : 400 Mechanical Attachment Operating Handle Type : Pointer Key
- Current Rating: 400 amps
- Operating Voltage: 32 volts
- Poles: 1 Pole
-
-
Supplier: TE Connectivity
Description: Removable Electrical Characteristics Operating Voltage (VDC) : 32 Switch Main Contact Current Rating (AMP) : 400 Mechanical Attachment Operating Handle Type : Double Wing
- Current Rating: 400 amps
- Operating Voltage: 32 volts
- Poles: 1 Pole
-
Supplier: Waytek, Inc.
Description: Eaton's Bussmann Series 15250-1BLR Battery Disconnect Switch Category: Battery Disconnects Manufacturer: Eaton Switch Type: Mechanical Amp Rating: 400A Max Volts: 50VDC Contact Action: On-Off Mounting Bracket included
- Current Rating: 400 amps
- Operating Voltage: 50 volts
- Power: DC
-
Supplier: Littelfuse, Inc.
Description: The 75920 Series Battery Disconnect Switches are high amp capacity, IP67 sealed, heavy-duty products that provide reliable emergency power cut-off. The switches are designed to be used up to 400A with single 4/0 cable at 12V DC or 200 A in 36 Vdc
- Current Rating: 400 amps
- Operating Voltage: 36 volts
- Power: DC
-
Supplier: Littelfuse, Inc.
Description: This product is not recommended for new designs The 75920 Series Battery Disconnect Switches are high amp capacity. IP67 sealed. heavy-duty products that provide reliable emergency power cut-off. The switches are designed to be used up to 400A with single
- Current Rating: 400 amps
- Operating Voltage: 36 volts
- Power: DC
-
Supplier: Allen-Bradley / Rockwell Automation
Description: 194R Fused and Non-Fused Disconnected Switches, Open, Non-Fused IEC, 400 A, 3 Pole ,
- Current Rating: 400 amps
- Type: Non-Fusible
-
Supplier: Allen-Bradley / Rockwell Automation
Description: 1494G Enclosed Disconnect Switches, 400A, Type 3R/4/12 - Enclosure Code F, 3 pole, three phase, Class J fuse clips, 600VAC
- Current Rating: 400 amps
-
Supplier: Allen-Bradley / Rockwell Automation
Description: 194R Fused and Non-Fused Disconnected Switches, Open, DIN fuse, 400 A, 3 Pole ,
- Current Rating: 400 amps
- Type: Fusible
-
Supplier: Allen-Bradley / Rockwell Automation
Description: 194R Fused and Non-Fused Disconnected Switches, Open, BS88 fuse, 400 A, 3 Pole ,
- Current Rating: 400 amps
- Type: Fusible
-
Supplier: Mersen
Description: Mersen?s fusible disconnect switches are listed to UL 98 and bear the CE mark conforming to IEC 60947-3. They are ?service entrance? devices capable of fully rated load-break and load-make. While longterm safety, reliability, and functionality are always paramount in the design of
- Approvals: IEC, UL, CSA Mark, RoHS
- Current Rating: 400 amps
- Fuse Type: Class J
- Mounting Style: Other
-
Supplier: Eaton Corporation
Description: HEAVY DUTY SAFETY TYPE 23 INCH W X 12-5/8 INCH D X 53-7/8 INCH H SIZE 4 WIRE(S) UL APPROVAL NEMA 3R ENCLOSURE 400 AMPERE CURRENT RATING 50 HP AT 240 VAC 3 PHASE (STANDARD FUSE) 125 HP AT 240 VAC 3 PHASE (TIME DELAY FUSE
- Approvals: UL
- Current Rating: 400 amps
- Fuse Type: Class H
- Horsepower Rating: 50 to 125 HP
-
Supplier: Eaton Corporation
Description: HEAVY DUTY SAFETY TYPE 23 INCH W X 12-5/8 INCH D X 53-7/8 INCH H SIZE 3 WIRE(S) UL APPROVAL NEMA 3R ENCLOSURE 400 AMPERE CURRENT RATING 250 HP AT 480 VAC 3 PHASE, 350 HP AT 600 VAC 3 PHASE, 50 HP AT 250 VDC POWER RATING 3 POLE
- Approvals: UL
- Current Rating: 400 amps
- Horsepower Rating: 50 to 350 HP
- Operating Voltage: 277 to 600 volts
-
Supplier: Eaton Corporation
Description: MANUAL TRANSFER TYPE UL APPROVAL NEMA 3R ENCLOSURE 400 AMPERE CURRENT RATING 50 HP AT 250 VDC POWER RATING 2 POLE(S) NO NEUTRAL TYPE 240 V AC VOLTAGE RATING 250 V DC VOLTAGE RATING NON FUSIBLE FUSE PROVISION APPLICABLE STANDARD NEMA KS-1, NEC 702 DT MODEL
- Approvals: UL
- Current Rating: 400 amps
- Horsepower Rating: 50 HP
- Operating Voltage: 240 volts
-
Supplier: Mersen
Description: Mersen disconnect switches are extremely durable and versatile. These heavy-duty switches are designed with the most up-to-date disconnect switch technology available. Designed to suit the UL98 standard, the switch gives you a product that makes and breaks
- Approvals: IEC, UL, CSA Mark, RoHS
- Current Rating: 400 amps
- Mounting Style: Other
- Operating Voltage: 250 volts
-
Supplier: Mersen
Description: Mersen offers a range of DC disconnect switches specially designed for PV applications, in one- and two-circuit configurations for both 1000V and 1500V DC applications. The technology inside the switch and the visible contacts allow a quick, safe, and reliable DC breaking at all
- Approvals: IEC, UL, RoHS, CE
- Current Rating: 400 amps
- Mounting Style: Other
- Operating Voltage: 1000 volts
-
Supplier: Unipower, LLC
Description: UNIPOWER Telecom’s LVD400 and LVD600 Series of low-voltage disconnect panels are designed for maximum flexibility. They can be used for either load or battery disconnect. The two mounting position (3.5 inches) high panels can also be configured as single or dual (A/B)
- Current Rating: 400 to 600 amps
-
Supplier: Zhejiang Benyi Electrical Co., Ltd
Description: Solar DC switch disconnect up to 1500V 400A BH-400 DC switch according to IEC60947.3 and AS60947.3 PV standard. One BH-400-2P DC switch disconnect can hold one 1000V string, current range from 250A to 400A. One BH-400-3P
- Approvals: RoHS, Other
- Current Rating: 250 to 400 amps
- Operating Voltage: 1000 to 1500 volts
- Poles: 2 Poles, 3 Poles, 4 Poles
-
Supplier: Schneider Electric
Description: Welcome to the complete residential energy management solution tailored to utilities and personalized for consumers. Wiser actively engages consumers and fulfills energy efficiency and peak demand initiatives, creating a more reliable grid.
- Approvals: UL
- Current Rating: 25 to 800 amps
- Fuse Type: Class CC, Class J
- Mounting Style: DIN Rail, Wall / Box Mount Receptacle
-
Supplier: Schneider Electric, Automation & Control
Description: Switch disconnectors from 40 A to 2500 A By adapting to a whole host of LV applications, the Compact INS/INV switch-disconnectors offer all the safety that the user requires. Designed for maximum performance and safety, this comprehensive and homogeneous range
- Approvals: IEC, Other
- Current Rating: 40 to 1250 amps
- Mounting Style: DIN Rail
- Operating Voltage: 500 to 690 volts
-
Supplier: RS Components, Ltd.
Description: The switch fuses from the ABB OS series are available in 3 or 4 pole. These fused switches are easy to use and snap to install, the adjustable mounting feet allow both top and side mounting of the switch fuse. Supplied with a black plastic ON/OFF handle (OHB45J6 for OS32-63 and
- Current Rating: 400 amps
- Fuse Type: Other
- Phase: Three Phase
- Poles: 3 Poles
Find Suppliers by Category Top
Featured Products Top
-
. Available in up to 3 switch functions. Multiple systems may be used in the same vicinity at the same time. 40 foot range of RF Transmission. 400 hours of battery life at 50% duty cycle. 3 AA batteries required for the Transmitter Enclosure: EN 60529 Degree of (read more)
Browse Foot Switches Datasheets for Linemaster Switch Corporation -
extremely resistant to high temperatures, and can handle a wide range of switching applications including battery disconnect switching, air conditioners, lights, and hydraulic motors. (read more)
Browse Electrical Contactors Datasheets for Waytek, Inc. -
The C800 series will be used in the truck’s power distribution unit (PDU), ensuring maximal safety, performance and durability – especially in battery emergency cases, in which the contactor safely disconnects the current to safeguard vehicle, driver and freight. The bi (read more)
Browse Electrical Contactors Datasheets for Schaltbau GmbH -
C303 – 1-pole bi-directional DC NO contactors up to 500 amps The Eddicy C303 1-pole bidirectional DC an AC contactors are compact high-performance switching devices for applications with high inrush (read more)
Browse Electrical Contactors Datasheets for Schaltbau GmbH -
, and can be used with either DC or AC power systems. Powerful, with the ability to handle up to 400 volts and 30 amps. It can carry 1.4x more current and 1.6x more voltage than the standard IEC 60320 C20 connector within the same footprint of a C14 connector. Compact, with a (read more)
Browse DC Power Connectors Datasheets for Anderson Power Products
More Information Top
-
CR4 - Thread: 12 KW Off Grid Unit Pricing
If the DC battery was 48V then the full load current becomes only around 250 amp , which is more like a normal system usign conventional off the shelf components. Once you get above 400 amps, the special disconnect switch and the protective fuses required for a safe design becomes problematic.
-
Cold Vacuum Drying (CVD) Electrical System Design Description
A 400 amp automatic transfer switch will switch the loads from the normal power system upon loss of power and provide a signal to start the diesel generator. … generator voltage and frequency have obtained setpoint values, the automatic transfer switch will disconnect the generator from … The diesel engine controls are operated by a 12V dc lead acid battery that is continuously charged …
-
Impact of Motor Capacitance on Vehicle Electrical System Transients
… such as wiper and cooling fans, the load currents are in the 5 to 15 amp range. … 4 Vdc, both conditions are readily satisfied and an arc discharge is expected across the switch contacts. … this load voltage reaches roughly zero volts (e.g. 12 V on the battery -side contact less … … current has decayed to a value below the minimum arcing current, or the 30 to 400 mA. … will either decay without any arcing (at which point the load is completely disconnected from the power …
-
Journal of Spacecraft and Rockets > SERT II - Mission, thruster performance, and in-flight thrust measurements
Redundant 115-vac, 400 -cycle inverters operating from the main SMR output power to any two of … A 40 amp -hr, silver oxide-zinc battery capable of at least five discharge cycles is electrically back biased from the house- keeping solar array and is instantaneously available for emergency conditions. Power switching for the telemetry and power systems is provided in the SSU, whereas experiment switching is … The P/C's are disconnected from the thruster array should the housekeeping array drop below 23v forlonger than …
-
The first stage of the electrification of the Estrada de Ferro Santos a Jundiai (late São Paulo Railway)
A lead-acid battery provides a supply for controlling the a.c. and d.c. circuit-breakers … Therefore automatic switching -in of loading resistors is provided in such substations. … voltagerisesabove the no-load value of 3 200 volts to the higher value of 3 400 volts. … contactor controlling the first step of resistance, thus allowing a current of approximately 86 amp to flow. … time-delay of 5 sec is imposed on each step to avoid repeated disconnections due to momentary …
-
Cal Poly's Series Hybrid Electric Vehicle for FutureTruck 2002
Battery Specifications: Hawker Genesis 12v16AhEP 12 Volt 16 Amp -hour (10 hour rate) 1600 Amp short circuit current 6.1 kg (13.5 lbs) each 147 kg (324 lbs) total pack weight 400 cycle rated life (100% depth of discharge) A small … 1 If power is sent to motor with no throttle input the emergency disconnect switch (EDS) opens.
-
Wave Energy Research, Development and Testing Including Testing of Materials and Technologies for Bio-Fouling and Corrosion Prevention
A switchgear enclosure that includes the contactors along with an electrical disconnect , current and voltage sensors, and … … for different voltage and power levels, and can be controlled by either contactor switching , converter control, or … An onboard power system developed by AXYS Technologies can supply up to 400 W of 24 Vdc … Primary power is provided by 40x sealed lead acid batteries (2000 Amp -hours at 24 Vdc), which are maintained through the use of a 1 kW wind generator, 2x 210 W solar panels and a 3.2 kW standby diesel generator.
-
https://digital.lib.washington.edu/researchworks/bitstream/handle/1773/20247/Zafonte_washington_0250E_10101.pdf?sequence=1&isAllowed=y
BNC switching is used to switch out various numbers of cells. Thus a very low bias current buffer amp is used to power the voltage dividers which generate the guard voltage and the “bootstrap” at the base of the battery chain. … put on the “rho” buffer instead of directly on the batteries, the characteristic 400 nV noise of … In the case of a controlled power down, it is easy to disconnect the positive side of …
-
The development of the electrical system on the Bristol Brabazon I Mark I Aircraft
Under these conditions, the direct current from one set surged to 800 amp before decaying to zero … Also, in the event of such a fault, the rectifier must be automatically disconnected from the busbar … … is placed on the back-up capacity of the two rectifiers and the batteries (of 120-Ah … … applied to a 28-volt d.c. busbar, with the set running at 400 c/s and the … … that overloading of the alternator is avoided and there is no need to switch off these loads …
-
Arduino Robotics
… of course to remotely control the dump bucket, so I found a 6 amp 24vdc linear actuator … CHAPTER 10 LAWN-BOT 400 Lawnmower Kill- Switch The Lawn-bot has a failsafe kill switch that disconnects the power to the motor controller, but … … was upgraded with several different useful items, such as high-capacity deep-cycle batteries , rugged pneumatic tires …
Indicates content that may require registration and/or purchase.