Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Accuris
Description: Autoclave Corrosion Testing of Metals in High-Temperature Water
-
Supplier: Accuris
Description: Evaluation of Internal Plastic Coatings for Corrosion Control of Tubular Goods by Autoclave Testing
-
Supplier: Accuris
Description: STANDARD TEST METHOD FOR AUTOCLAVE EXPANSION OF PORTLAND CEMENT
-
-
Supplier: Accuris
Description: Test Method for Determination of Autoclave Expansion
-
Supplier: NACE International
Description: REAFFIRMED IN 2006! Provides manufacturers, applicators, and users of internal pipe coatings with a method of comparing the performance of these coatings. Comparisons were made under uniform laboratory conditions. Key words: autoclave testing, oilfield production equipment, plastic
-
Description: REAFFIRMED IN 2006! Provides manufacturers, applicators, and users of internal pipe coatings with a method of comparing the performance of these coatings. Comparisons were made under uniform laboratory conditions. Key words: autoclave testing, oilfield production equipment, plastic
-
Supplier: ASTM International
Description: 1.1 This test method covers determination of the autoclave expansion of portland cement by means of a test on a neat cement specimen. 1.2 The values stated in inch-pound units are to be regarded as the standard. 1.3 This standard does not purport to address all of the safety problems, if any,
-
Supplier: ASTM International
Description: 1.1 This test method covers determination of the autoclave expansion of hydraulic cement by means of a test on a neat cement specimen. 1.2 The values stated in inch-pound units are to be regarded as the standard. 1.3 This standard does not purport to address all of the safety concerns, if
-
Description: always comparable or which are of limited utility because of difference in testing techniques, method of analyses, or deficiencies in the reporting of results. This lack of uniformity in corrosion testing prompted NACE Unit Committee T-7D on High Purity and Power Plant Water to make
-
Supplier: NACE International
Description: always comparable or which are of limited utility because of difference in testing techniques, method of analyses, or deficiencies in the reporting of results. This lack of uniformity in corrosion testing prompted NACE Unit Committee T-7D on High Purity and Power Plant Water to make
-
Supplier: NACE International
Description: test materials to simulated environmental conditions for various lengths of time. The general methods used for testing may be similar, but techniques and procedures usually vary widely. The lack of standardized test methods for high-temperature water corrosion testing results in data
-
Description: test materials to simulated environmental conditions for various lengths of time. The general methods used for testing may be similar, but techniques and procedures usually vary widely. The lack of standardized test methods for high-temperature water corrosion testing results in data
-
Description: evaluating the performance of plastic coatings for tubular goods in specific environments at elevated temperatures and pressures by use of an autoclave. 1.2 This test method is intended to standardize laboratory test procedures and aid in evaluating the general performance of plastic coatings
-
Description: The unbiased autoclave test is performed to evaluate the moisture resistance integrity of non-hermetically packaged solid-state devices using moisture condensing or moisture saturated steam environments. It is a highly accelerated test which employs conditions of pressure, humidity and
-
Supplier: CSA Group
Description: The unbiased autoclave test is performed to evaluate the moisture resistance integrity of non-hermetically packaged solid-state devices using moisture condensing or moisture saturated steam environments. It is a highly accelerated test which employs conditions of pressure, humidity and
-
Supplier: AMPP Resources
Description: evaluating the performance of plastic coatings for tubular goods in specific environments at elevated temperatures and pressures by use of an autoclave. 1.2 This test method is intended to standardize laboratory test procedures and aid in evaluating the general performance of plastic coatings
-
Supplier: ASTM International
Description: 1.1 This practice covers the installation and testing of solid, reinforced units made from autoclaved aerated concrete (AAC), a cementitious product addressed by Specification . The units are large-sized, factory-reinforced, solid rectangular prisms, laid using thin-bed mortar. 1.2 The values
-
Supplier: ASTM International
Description: 1.1 This test method covers the determination of the crazing resistance of fired glazed whitewares using the autoclave treatment and under the conditions specified in this test method. 1.2 The values stated in inch-pound units are to be regarded as the standard. The values given in
-
Supplier: Transcat, Inc.
Description: Product Highlights Pressure ranges to 36,000 psi (2500 bar) 0.025%, 0.05%, 0.1% or 0.2% FS accuracy % pressure indication with fan-shaped graph scale for visual reference Fully temperature compensated accuracy Panel mount version is available Large, easy to read display with 5-digit resolution Back
- Working Pressure Range: 36,259.425 psi
- Type: Gauge
-
Supplier: Cole-Parmer
Description: • Time-saving features improve efficiency in your lab • Store customized sterilization programs for repeated use • Cooling fan minimizes cooling time • Operation and display panel located on top of sterilizer for easy viewing These vertical autoclaves are perfect for sterilization of
- Application: Laboratory
-
Supplier: Cole-Parmer
Description: • Time-saving features improve efficiency in your lab • Store customized sterilization programs for repeated use • Cooling fan minimizes cooling time • Operation and display panel located on top of sterilizer for easy viewing These vertical autoclaves are perfect for sterilization of
- Application: Laboratory
-
Supplier: Transcat, Inc.
Description: Product Highlights Pressure ranges to 36,000 psi (2500 bar) 0.025% full scale accuracy (ADT 681-02) 0.05% full scale accuracy (ADT 681-05) 0.1% full scale accuracy (ADT 681-10) 0.2% full scale accuracy (ADT 681-20) Fully temperature compensated accuracy from14°F to 122°F (-10°C to 50°C) Up to
- Working Pressure Range: 30,000 psi
- Type: Gauge
-
Supplier: Cole-Parmer
Description: • Time-saving features improve efficiency in your lab • Store customized sterilization programs for repeated use • Cooling fan minimizes cooling time • Operation and display panel located on top of sterilizer for easy viewing These vertical autoclaves are perfect for sterilization of
- Capacity: 1.0999999999999999 cubic feet
- Application: Laboratory
-
Description: Describes test methods to determine the resistance of stainless steel surgical and dental hand instruments against autoclaving, corrosion and thermal exposure.
-
Supplier: CSA Group
Description: Describes test methods to determine the resistance of stainless steel surgical and dental hand instruments against autoclaving, corrosion and thermal exposure.
-
Supplier: Bio-Rad Laboratories, Inc.
Description: Pkg of 10 racks, 96 micro test tubes per rack (960 tubes), 1 ml, 8.8 x 45 mm, unsterilized, autoclavable Titertube® 1 ml micro test tubes allow efficient preparation and storage of large numbers of samples in an 8 x 12 format. Tubes and racks are made of polypropylene; they are autoclavable to
- Volume: 1 cc
-
Supplier: Bio-Rad Laboratories, Inc.
Description: Pkg of 10 racks, 96 micro test tubes per rack (960 tubes), 1 ml, 8.8 x 45 mm, presterilized, not autoclavable Titertube® 1 ml micro test tubes allow efficient preparation and storage of large numbers of samples in an 8 x 12 format. Tubes and racks are made of polypropylene; they are autoclavable to
- Volume: 1 cc
-
Supplier: SKS Science Products
Description: These standard round-bottom culture tubes are manufactured from "300" borosilicate clear glass (meets ASTM Type I Class B and USP Type I standards). The tubes can be autoclaved and reused many times. The black caps have a white styrene-butadiene rubber liner which creates a tight seal, protecting
- Features: Other
-
Supplier: Cole-Parmer
Description: • High calibration accuracy with data logging capabilities • Power transmitters during testing using built-in 24 volt loop supply • Pressure switch test • HART® communication capability • Advanced temperature compensation • Backlight, dual readout display with six-digit resolution •
- Environmental Properties: Pressure / Vacuum
-
Supplier: Ralston Instruments, Inc.
Description: QTHA-2MS0-MP 1/4" male Medium Pressure x male Quick-test, S.S. Connect to any Medium Pressure connection Ideal for connecting to Autoclave Engineers, Butech, HIP or Parker Medium Pressure connections Connect to pressure calibrators or graphing pressure reference recorders with 1/4" Medium
- English Size: 0.25 inch
- Fitting Type: Adapter, Quick Coupler
- Features: English, Stainless Steel
-
Supplier: Ralston Instruments, Inc.
Description: XTHA-2MS0-MP 1/4" male Medium Pressure x male Quick-test XT, S.S. Connect to any female Medium Pressure adapter from HIP, Autoclave Engineers or Butech Connect to pressure calibrators or graphing pressure reference recorders with 1/4" Medium pressure connections Note that these are not
- English Size: 0.25 inch
- Fitting Type: Adapter, Quick Coupler
- Features: English, Stainless Steel
-
Supplier: Ralston Instruments, Inc.
Description: QTHA-2MSA-XH 1/4" male High Pressure x female Quick-test, no check-valve, S.S. Connect a Female High Pressure 60 degree coned and threaded pressure fitting to a Quick-test hose Excellent for connecting to Autoclave Engineers, Butech, HIP (High Pressure Equipment), Parker or equivalent High
- English Size: 0.25 inch
- Fitting Type: Adapter, Quick Coupler
- Features: English, Stainless Steel
-
Supplier: Ralston Instruments, Inc.
Description: XTHA-2MS0-XH 1/4" male High Pressure x male Quick-test XT, S.S. Connect a Female 60 degree coned and threaded pressure fitting to a Quick-test XT 10,000 psi hose Excellent for connecting to Autoclave Engineers, Butech, HIP (High Pressure Equipment), Parker or equivalent High Pressure coned
- English Size: 0.25 inch
- Fitting Type: Adapter, Quick Coupler
- Features: English, Stainless Steel
-
Supplier: AENOR
Description: TEST METHODS OF CEMENTS. PHYSICAL ANALYSIS. DETERMINATION OF THE AUTOCLAVE EXPANSION
-
Supplier: AENOR
Description: Test methods of cements. Physical analysis. Determination of the autoclave expansion
Find Suppliers by Category Top
Featured Products Top
-
to the steam. Portescap performs in-house autoclave durability testing on motors using hospital grade equipment. On most motors, the pressure, steam and temperature can lead to premature damage or destruction of bearings, sensors, magnets and stators resulting in either poor performance or motor (read more)
Browse Brushless Motors Datasheets for Portescap -
cable and harness assemblies, including solutions for large composite autoclave systems used in the aerospace industry and smaller (read more)
Browse Feedthroughs Datasheets for Conax Technologies -
ESPEC North America Inc | Qualmark Products and Services
HAST - Highly Accelerated Stress Test Chambers
HAST (Highly Accelerated Stress Test) chambers reduce the time it takes to complete humidity testing for semiconductors. By elevating temperatures above 100°C and increasing the pressure, simulation of normal humidity tests can be made while maintaining the same failure mechanisms. Tests can (read more)
Browse Environmental Test Chambers and Rooms Datasheets for ESPEC North America Inc | Qualmark Products and Services -
Douglas Electrical Components provides hermetic seals and high-voltage epoxy feedthroughs for a wide range of medical and laboratory equipment, including x-ray systems, hyperbaric chambers, lasers, autoclaves, lyophilizers, and centrifuges. These solutions are designed to reliably transmit power (read more)
Browse Military (MIL-SPEC) Connectors Datasheets for Douglas Electrical Components -
Customized Medical Solutions E-Z-Hook manufactures many of our standard hooks in high temperature resistant material to withstand the ongoing sterilization and autoclaving demands in the medical field. We also offer an (read more)
Browse Datasheets for E-Z-HOOK, a division of Tektest, Inc. -
emphasis on critical issues such as, selection of seals, bearings, and lubrication, encapsulation of windings, stators, and electronics, comprehensive electromechanical designs and, performing thorough in-house testing. These practices collectively result in proven designs capable of (read more)
Browse Brushless Motors Datasheets for Portescap -
.) > Passivation and plating (electroless nickel, gold, tin, etc.) > High temp molded parts for autoclaving and sterilization > Variable spring tension & specialized hook bends > Color coded connectors and test lead or cable assemblies > Test Reports, testing, and (read more)
Browse Electrical Test Probes Datasheets for E-Z-HOOK, a division of Tektest, Inc. -
. This offers customers the best in safe and dependable medical cables. To further ensure its biocompatibility in the most critical medical applications, Northwire completed laboratory testing to validate the compliance to ISO 10993-10:2021 irritation and skin sensitization requirements (read more)
Browse Medical Cable Assemblies Datasheets for Northwire, Inc. -
°C enabling processes like sterilization by autoclaving. The IST AG LFS1305 conductivity sensor is available with Pt/Ni wires as standard wires. LFS1505 The IST AG LFS1505 conductivity sensor (read more)
Browse Datasheets for Innovative Sensor Technology IST USA Division -
your application. To ensure your success, we offer a comprehensive suite of services, including: Custom formulation and material selection (Low volatile Silicone available) In-house and MAESTRAL laboratory testing and characterization Full quality assurance and (read more)
Browse Dynamic Seals Datasheets for Technetics Group
Conduct Research Top
-
Autoclaving Resistance of Medical Adhesives
Bond has developed a wide variety of products for this purpose. Many compounds have been successfully tested for the U.S. Pharmacopeia (USP) Class VI requirements, and some select systems among them can withstand repeated autoclaving exposure.
-
Multi-Conductor Compatibility with Steam (Autoclave) and Gas Plasma (STERRAD (R)) Sterilization
Medical electronics device designers require materials that can be expected to sustain repeated sterilization exposure. Steam sterilization through autoclave is a well-known method. Gas plasma sterilization through the STERRAD (R) system is more recently established but becoming more common
-
UV Curing Adhesives Compatible with Medical Sterilisation Processes
cure in seconds. In addition cured acrylates are compatible with common sterilisation processes such as autoclaving, gamma and ETO. They maintain high adhesion after sterilisation. Interestingly, in several tests electron beam sterilisation has even improved the adhesion.
-
GSK, Pall Speed Microbiological Contamination Detection
the user the opportunity to adopt the technology in a broad range of applications, including pharmaceutical product release, monitoring pharmaceutical water systems, environmental contamination monitoring, testing biological indicators used e.g. for autoclave validation and qualifying microbial
-
Chiron's Curse
to support manufacturing method deviations Stability program was inadequate re: thimersol effectiveness and final container testing Aseptic processing was inadequate re: media fills, requalification of in-process aseptic processes, and proper monitoring of air flow and pressure differentials Protocols
More Information Top
-
Development of an acoustic sensor for a geothermal borehole televiewer
Investigating Sources of Autoclave Test Problemsoooooooo.oooo111 .
-
History and Status of Performance Tests for Evaluation of Soundness of Cements
ABSTRACT: The history of the commonly used performance tests for sound- ness of cement and the evolution of the autoclave test are reviewed.
-
Fretting-Wear Behavior of Zircaloy-4, OPTIN™, and ZIRLO™ Fuel Rods and Grid Supports under Various Autoclave and Hydraulic Loop Endurance Test Conditions
During the autoclave tests , a proprietary software program was used to compute work-rate at any time.
-
CORROSION AND WEAR HANDBOOK FOR WATER COOLED REACTORS
Schematzc diagram of $ow type autoclave test .
-
A Rapid Autoclave Mortar Bar Method to Determine the Potential Alkali-Silica Reactivity of St. Lawrence Lowlands Carbonate Aggregates (Quebec, Canada)
the microstructure of the reaction products developed within the mortar bars tested through the autoclave test , made with non- reactive-to-highly expansive aggregates, was studied under the SEM (JEOL No. 25S3 equipped with an EDXA Tracor Northern 5500).
-
Reappraisal of the Autoclave Expansion Test
The case for such a reappraisal had been argued by Mehta in his paper "History and Status of Performance Tests for Evaluation of Soundness of Cements" (Mehta 1978), He summarized the evolution, status, and criticism of the autoclave test .
-
Enhancement of Aqueous Corrosion of Zircaloy-4 Due to Hydride Precipitation at the Metal-Oxide Interface
…oxidizing coolant conditions in the presence of neutron irradiation (e.g., in the boiling light water reactor [BWR] environment) has been observed to be significantly accelerated compared with the corrosion rate measured in the ex-reactor autoclave tests conducted at comparable temperatures…
-
In-situ Creep Testing Capability Development for Advanced Test Reactor
Overall Objective of Autoclave Testing Effort ...............................................................
-
Exploratory Research on Novel Coal
One-Liter Autoclave Tests .
-
Hydrogen generation by metal corrosion in simulated Waste Isolation Pilot Plant environments. Progress report for the period November 1989 through December 1992
5.1.2 Autoclave Test Method .................................
Indicates content that may require registration and/or purchase.