Supplier: Allied Electronics, Inc.
Description: This range of LCD and LED instruments includes a 31⁄2 digit ±200 mVDC full scale reading LCD voltmeter, a 500 VAC voltmeter, a graphics module, a 4-20 mA loop powered meter and a bi-color LED backlit, LCD Voltmeter. Optional NEMA 4X rated alloy bezels fit all
-
Supplier: Allied Electronics, Inc.
Description: Hour Meter (EMC 1500), Thermometer (EMT 1900), 2-wire 3 digit DC Voltmeter (EMV 1200 and EMV 1200-40) and 31⁄2 digit DC Voltmeters (EMV 1125 and EMV 1025S-01).
-
Supplier: RS Components, Ltd.
Description: Indicator current and voltage PA419
- Display Digits: 5 Digits
- Standards and Certifications: RoHS Compliant
-
-
Supplier: Allied Electronics, Inc.
Description: A range of snap-in, sub-miniature digital panel instruments with LED backlighting for low light conditions and single or dual rail operation for ease of use. LED and 4-20 mA versions of the range are also available.
-
Supplier: Allied Electronics, Inc.
Description: A range of snap-in, sub-miniature digital panel instruments with LED backlighting for low light conditions and single or dual rail operation for ease of use. LED and 4-20 mA versions of the range are also available.
-
Supplier: Trumeter Company, Inc.
Description: The APM Analogue Effect Digital Panel Meters from Trumeter are both unique and flexible, with a wide range of back light colour options available and a custom curved 40 segment analogue display making it as easy to read as any analogue moving coil or moving iron instrument with
- Operating Temperature: -10 to 50 C
- Display Digits: 4 Digits
- Measurement Type: AC, AC / DC, DC
- Features: Digital
-
Supplier: RS Components, Ltd.
Description: DIGITAL DISPLAY DC AMMETER AND VOLTMETER
- Number of Digits: 3
- Width: 96 mm
- Height: 48 mm
- Depth: 48 mm
-
Supplier: Cole-Parmer
Description: Two precision instruments in one, meets IEC 1010 CAT III 1000V
- DC Voltage Range: 1,000 volts
- AC Voltage Range: 1,000 volts
- AC Current Range: 2,000 amps
- Form Factor: Clamp Meter
-
Supplier: Transcat, Inc.
Description: Product Highlights Resolution: 6000 digits (3 6/7 place) and analog bar graph TRMS measuremnts VAC and IAC Basic accuracy: 0.5% VDC Patented automatic blocking sockets (ABS) Voltage: VDC 100µ to 600 V and VAC 100µ to 600 V Current: IDC 10µ to 10 A (16 A 30 sec.) and IAC
-
Supplier: DigiKey
Description: Current (Ammeter), Voltage (Voltmeter) TFT - Color (Touch) Display Panel Mount
- Voltage Range: 40 volts
- Current Range: 0.004 amps
- Width: 117 mm
- Height: 78 mm
-
Supplier: SOCOMEC
Description: The DIRIS Digiware system is a hub of technological innovations that revolutionises the world of measurements, bringing a high degree of flexibility to installations and making connection and configuration easy. These innovations, together with unrivaled performance in terms of
- AC Voltage Range: 50 to 520 volts
- Frequency Range: 45 to 65 Hz
- Operating Temperature: -10 to 55 C
- Measurement Type: AC
-
Supplier: Hoyt Electrical Instrument Works, Inc.
Description: Full auto range for V.A and Ω functions. Data hold function freezes the reading in dimly lit or hard to reach places. Low battery indication. Built-in buzzer for continuity test. Safety design throughout with no exposed metal parts. Shielded banana plugs and recessed input terminals.
- DC Voltage Range: 400 to 600 volts
- AC Voltage Range: 400 to 600 volts
- DC Current Range: 400 to 1,000 amps
- AC Current Range: 400 to 1,000 amps
-
Supplier: Lake Shore Cryotronics, Inc.
Description: of multiple function-specific instrumentation setups, combining the convenience of DC and AC sourcing with DC and AC measurement, including a lock-in's sensitivity and measurement performance.
- Form Factor: Bench / Free-Standing
- Measurement Type: DC
- Features: Digital
-
Supplier: OMEGA Engineering, Inc.
Description: The Omega® CA450 Process Multimeter is a portable test instrument to combine a digital RMS multimeter and a loop calibrator to give process technicians the same functionality in one tool. The model CA450 provides 24V loop power, reducing the need for carrying a separate power supply
- DC Voltage Range: 0 to 1,000 volts
- AC Voltage Range: 0 to 1,000 volts
- DC Current Range: 0.1 to 180 amps
- AC Current Range: 0.1 to 3,000 amps
-
Supplier: Panel Components & Systems, Inc.
Description: meters designed for single-phase and 3-phase systems. These include Mains measurement analyzers, power meters, AC ammeters, voltmeters and frequency meters, as well as a combination voltmeter/frequency meter. Features: True RMS measurements AC RMS voltage, AC RMS
- Display Colors: Aqua
- Display Technology: LED
- Display Type: Numeric Display
-
Supplier: Transcat, Inc.
Description: Overview Versatile meters for field service or bench repair. The Fluke 77 IV digital multimeter has the features needed to repair most electrical and electronic problems. This meter is simple to use and has significant improvements over Fluke's original 70 Series with more
-
Supplier: SOCOMEC
Description: stored. All data, ie. total and partial meters and load curves (available for all logical and analogue inputs) can be centralised via RS485 communication using MODBUS protocol. Advantages Up to 7 multi-utility meters and 2 analogue sensors • 7 logical inputs + 2 analogue
- DC Voltage Range: 10 to 30 volts
- Operating Temperature: -10 to 55 C
- Measurement Type: DC
- Features: Digital
-
Supplier: SOCOMEC
Description: The COUNTIS E4x is a modular active and reactive electrical energy meter displaying the energies and active power consumed (kWh, kvarh and kW) directly on its backlit LCD display. It is designed for three-phase load metering with connection via CT and is suitable for
- Operating Temperature: -10 to 55 C
- Measurement Type: AC
- Features: Digital
- Form Factor: Rack-Mounted
-
Supplier: SOCOMEC
Description: solution. Advantages Easy to use Thanks to its large backlit LCD display and its multiple viewing screens with direct pushbutton access, DIRIS A20 provide clear readings and are easy to use. They directly display a number of multimeasurement and metering values : + kWh, + kvarh,
- AC Voltage Range: 28 to 500 volts
- AC Current Range: 0 to 11,000 amps
- Operating Temperature: -10 to 55 C
- Measurement Type: AC
-
Supplier: OMEGA Engineering, Inc.
Description: The HHM250 is a clamp on multifunction meter that provides high accuracy and reliability in a low cost portable package. The clamp allows for measurement of AC current to 660 amps and AC voltage to 600 volts. Ideal for monitoring electrical power sources to troubleshoot or evaluate.
- AC Voltage Range: 600 volts
- Operating Temperature: 0 to 40 C
- AC Current Range: 660 amps
- Resistance / Impedance Range: 0 to 0.6 kohms
-
Supplier: Transcat, Inc.
Description: Product Highlights Triple display with a resolution of ±310,000 digits Intrinsic error: ± (0.02% rdg. + 20 digits) Measuring functions: 1 µV to 600 VDC and 10 µV to 600 VAC/AC+DC TRMS (bandwidth: 15 Hz to 100 kHz) 1 nA to 10 ADC and 10 nA to 10 AAC/AC+DC TRMS (bandwidth: 15 Hz to 10
-
Supplier: Hoyt Electrical Instrument Works, Inc.
Description: Designed for AC current and AC voltage. AC testing has 5 ranges. The minimum resolution of leakage current is 0.1mA., Frequency selection: 50/60 Hz and Wide. Data hold function and low battery indication.0-200MAAC, 2/20/200, 1000AAC, up to 600 VAC.
- AC Voltage Range: 200 to 600 volts
- Operating Temperature: -20 to 60 C
- AC Current Range: 0 to 1,000 amps
- Display Digits: 3 Digits, Plus 1/2 Digit
-
Supplier: Teledyne LeCroy
Description: Temperature: Support for TC and RTD sensor Main Features and Functions of the T3DMM6-5 4.3” TFT-LCD, 480*272 Real 6½ digits readings resolution (2,200,000 counts) True-RMS AC Voltage and AC Current measuring File management (support for U-disc and local storage) Built-in
- DC Voltage Range: 0.6 to 1,000 volts
- AC Voltage Range: 0.6 to 750 volts
- DC Current Range: 0.0006 to 10 amps
- AC Current Range: 0.0006 to 10 amps
-
Supplier: OMEGA Engineering, Inc.
Description: The Model HHM59 is a lightweight completely portable digital clamp meter with a 3 1 /2 digit LCD display. This meter is well suited for use by electricians and technicians who require a portable instrument that is accurate and reliable and that has full digital
- DC Voltage Range: 1,000 volts
- AC Voltage Range: 750 volts
- AC Current Range: 1,000 amps
- Resistance / Impedance Range: 2,000 kohms
-
Supplier: OMEGA Engineering, Inc.
Description: The HHM61 combination DMM/ac current clamp meter/digital thermometer is a compact, lightweight, multi-function test and measurement instrument at an economical price. The HHM61 is ideal for electrician’s and technicians who need a portable test instrument that is both accurate
- DC Voltage Range: 400 volts
- AC Voltage Range: 750 volts
- AC Current Range: 400 amps
- Display Digits: 3 Digits, Plus 1/2 Digit
-
Supplier: Hoyt Electrical Instrument Works, Inc.
Description: Using electrical parameters means using several analog or digital single-function products such as ammeters, voltmeters or watt meters. DIRIS A20, with its four direct access keys and LCD displays, helps you use all the parameters in an LV installation. These parameters
- Operating Temperature: 14 to 131 F
- Input Type: AC Current, AC Voltage, DC Current, DC Voltage
- Display Type: Alphanumeric Display
- Outputs: Analog, Relay, Serial
-
Supplier: Greenlee Textron, Inc.
Description: DIGITAL TYPE LCD DISPLAY TYPE UL (CANADA AND US), CE APPROVAL 3 V STANDARD BUTTON BATTERY TYPE TEST LEAD INCLUSION AC CURRENT, AC/DC VOLTAGE, RESISTANCE PARAMETER MEASURED 1.02 INCH JAW OPENING 400 OHM, 4/40/400 KILO OHM, 4/40 MEGA OHM RESISTANCE RANGE 40/400/600 AMPERE AC CURRENT
- DC Voltage Range: 4 to 600 volts
- AC Voltage Range: 4 to 600 volts
- AC Current Range: 40 to 600 amps
- Resistance / Impedance Range: 0.4 to 40,000 kohms
-
Supplier: DigiKey
Description: MULTIMETER MANUAL RANGING DMM
- Form Factor: Handheld
-
Supplier: Radwell International
Description: ELECTRONIC LOAD, 4-60VDC, 0-60AMP, 300W, DIGITAL VOLTMETER AND AMMETER, 3.5 DIGIT, 10-TURN MULTI-DIAL, BUILT IN OSCILLATOR FOR SWITCHING FUNCTIONS. FREE 2 YEAR RADWELL WARRANTY
-
Supplier: REED-Direct
Description: Touch Zero and Data Hold functions Polarity and overload indications Continuity test Auto or manual ranging Auto power-off Low battery indication Include test leads, soft carrying case and batteries Ce EN61010 600V CAT lll 300V CAT lll SPECIFICATIONS: AC/DC Current Range: 40A,
- DC Voltage Range: 0 to 600 volts
- AC Voltage Range: 0 to 600 volts
- DC Current Range: 0 to 400 amps
- AC Current Range: 0 to 400 amps
-
Supplier: Lincoln Electric Co. (The)
Description: Top Features Two output connectors - Allow you to connect to high or low inductance for optimal arc control. Digital Ammeter/Voltmeter - Display allows presets for added convenience and accuracy. Seven-year warranty on power rectifier. Input Power 208/230/460/3/60
- Duty Cycle: 100 %
- Output Current Range: 50 to 400 amps
- Output Voltage Range: 7 to 37 volts
- Output Power Capability: DC Output
Find Suppliers by Category Top
Featured Products Top
-
Abundant data analysis functions such as Search, Navigate, Digital Voltmeter, Counter, Waveform Histogram, Bode plot, Power Analysis and Eye/Jitter Analysis High-Speed hardware-based Average, Hi-Res; High Speed hardware-based Mask Test function, with Mask Editor tool for creating user (read more)
Browse Power Supplies Datasheets for Siglent Technologies NA, Inc. -
, and other values from the test circuits These values are monitored via ammeters, voltmeters, or automated test equipment to determine whether the circuits are working properly. This principle forms the foundation for subsequent testing methods, including ICT (in-circuit test) and FCT (read more)
Browse Printed Circuit Substrate Materials (PCB / PWB) Datasheets for FX PCB Co., Ltd. -
/Arbitrary Waveform Generator Spectrum Analyzer Digital Voltmeter High-Precision Frequency Counter Protocol Analyzer Jitter/Eye Analyzer Power Analyzer (read more)
Browse Oscilloscopes Datasheets for Uni-Trend US -
. A Nine-in-One powerhouse, the UNI-T MSO3000HD series offers instruments with functions that include a Real 12-bit, High-Definition Digital Oscilloscope, Logic Analyzer, Function/Arbitrary Waveform Generator, Spectrum Analyzer, Digital Voltmeter, High-Precision Frequency (read more)
Browse Oscilloscopes Datasheets for Uni-Trend US -
-Definition Digital Oscilloscope, Logic Analyzer, Function/Arbitrary Waveform Generator, Spectrum Analyzer, Digital Voltmeter, High (read more)
Browse Oscilloscopes Datasheets for Uni-Trend US -
, Function/Arbitrary Waveform Generator, Spectrum Analyzer, Digital Voltmeter, High-Precision Frequency Counter, Protocol Analyzer, Jitter/Eye Analyzer and Power Analyzer. This oscilloscope offers a cost-effective solution for advanced users. Main Features of the MSO7000X Series (read more)
Browse Oscilloscopes Datasheets for Uni-Trend US -
potentiometer connected to the module’s 5.2 V reference voltage source. The control voltage is monitored by a programmable volt-meter and converted to the output voltage by the stored calibration. Alternatively, the control voltage can be read by a multimeter on corresponding test points. A (read more)
Browse Power Supplies Datasheets for Daitron Co., Ltd. -
2-Wire vs. 4-Wire Terminal Connection for Resistance Testing Precision digital multimeters (DMMs) and source measurement units (SMUs) offer two (read more)
Browse Power Transformers Datasheets for Triad Magnetics
More Information Top
-
http://www.ijera.com/papers/Vol4_issue1/Version 1/AS4101256260.pdf
The voltage and current across the heater is measured by a digital voltmeter ammeter .
-
Nitrate removal from drinking water in a packed‐bed bioreactor coupled by a methanol‐based electrochemical gas generator
Numerical items: (1) variable AC transformer, (2) rectifier, (3) capacitor, (4) digital voltmeter and ammeter , (5) electrolyte solution (methanol/water and KOH), (6) graphite plate (EK20), (7) carbon dioxide collector, (8) hydrogen col- lector, (9) gas flow meter, (10) gas injection isolated compressor …
-
The Role of Renewable Energy Technology in Holistic Community Development
The lamp was driven using a power supply with regulated voltage (3) (Keithley 2430 SourceMeter), which is equipped with digital voltmeter and ammeter .
-
Performance of Photovoltaic Module for Different Sites in Iraq
The system consists of PV module connected to digital voltmeter / ammeter device and DC load.
-
Buoyancy and cross flow effects on heat transfer of multiple impinging slot air jets cooling a flat plate at different orientations
Voltage and current supplied to the heater were measured by digital voltmeter and ammeter of accuracy 0.025%.
-
Modeling of Linear Gas Tungsten Arc Welding of Stainless Steel
Welding current and voltage were measured using a digital voltmeter and ammeter , provided in the welding machine.
-
Experimental investigation of natural convection heat transfer in horizontal and inclined annular fluid layers
The voltage and current supplied to the heater were measured by digital voltmeter and ammeter of accuracy 0.025%.
-
Salinity Gradient - Source of Energy In the Coastal Zone of Ocean
Experimental electrodialysis battery 1 - frames, 2 - crimped grid, 3 – outer load, 4, 5 – top and bottom pressure plates respectively, 6 – digital voltmeter and ammeter , 7 – recording voltmeter and ammeter, 8 – fresh water, 9 – sea water, 10 …
-
Influence of Lead Oxide Introduction into the Composition of Phase-Separated Alkali Borosilicate Glasses on the Electrosurface Characteristics of Porous Produc...
The current was mea- sured using a V7-27A digital voltmeter – ammeter .
Indicates content that may require registration and/or purchase.