Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Det-Tronics
Description: The evolution continues with the new X2200 UV Flame Detector. Approved to FM 3260 (2000), the X2200 meets the most stringent requirements worldwide with advanced detection capabilities and immunity to extraneous sources, combined with a superior mechanical design. The detector
- Maximum Response Time: 1 seconds
- Maximum Detector Range (Sensitivity): 85 ft
- Operating Temperature: -40 to 167 F
- Features: Adjustable Time Delay, Automatic Self-test, Explosion Proof, NEMA 4 Rated Enclosure, Other
-
Supplier: Det-Tronics
Description: FM, CSA, CENELEC, CE, VDS, CNBOP Approvals EN54-10 Certified Output Options include: Relays, 4-20 mA, EQP Addressable, and Pulse Output* *When pulse output is specified, the infrared (IR) flame detector is for use in controller based systems. The pulse-output model can replace existing
- Maximum Response Time: 0.04 to 15 seconds
- Maximum Detector Range (Sensitivity): 2 to 85 ft
- Operating Temperature: -40 to 167 F
- Features: Adjustable Time Delay, Automatic Self-test, Explosion Proof, NEMA 4 Rated Enclosure, Other
-
Supplier: Det-Tronics
Description: a 90-degree cone of vision. When both sensors simultaneously detect the presence of a flame, an alarm signal is generated. The detector has Division and Zone explosion-proof ratings and is suitable for use in indoor and outdoor applications. Automatic, manual or magnetic optical
- Maximum Response Time: 15 seconds
- Maximum Detector Range (Sensitivity): 85 ft
- Operating Temperature: -40 to 167 F
- Features: Adjustable Time Delay, Automatic Self-test, Explosion Proof, NEMA 4 Rated Enclosure, Other
-
-
Supplier: MSA Safety
Description: The General Monitors® FL500 UV/IR Flame Detector by MSA delivers fast, dependable flame detection with enhanced false alarm immunity-all in a compact, industrial-grade design. By monitoring both ultraviolet (UV) and infrared (IR) radiation, the FL500 provides rapid response to
- Maximum Response Time: 3 seconds
- Maximum Detector Range (Sensitivity): 45 to 90 ft
- Operating Temperature: -67 to 185 F
- Features: Adjustable Time Delay, Automatic Self-test, Explosion Proof, Other
-
Supplier: Honeywell Analytics, Inc.
Description: Fire Sentry SS3 Multi-Spectrum Optical Fire and Flame Detectors are fast reacting, digital, reprogrammable, computerized — smart technology. The Fire Sentry SS3 fast-reacting, Ultraviolet (UV), Wide Band Infrared (IR) and Visible spectral brand electro-optical digital fire and
- Maximum Response Time: 2 to 5 seconds
- Maximum Detector Range (Sensitivity): 30 ft
- Operating Temperature: 32 to 170 F
- Device Classification: Sensor
-
Supplier: Global Detection Systems Corp.
Description: No Description Provided
- Maximum Response Time: 5 seconds
- Maximum Detector Range (Sensitivity): 200 ft
- Operating Temperature: -40 to 185 F
- Output Options: Analog Current, Switch or Alarm
-
Supplier: MSA Safety
Description: The MSA General Monitors® FL5000 MSIR Flame Detector sets a high standard in industrial fire protection with advanced multi-spectrum IR sensing and AI-driven flame recognition. It detects fires up to 310 feet away while minimizing false alarms from sources like sunlight or
- Maximum Response Time: 10 seconds
- Maximum Detector Range (Sensitivity): 70 to 310 ft
- Operating Temperature: -67 to 176 F
- Features: Adjustable Time Delay, Automatic Self-test, Explosion Proof, Other
-
Supplier: Det-Tronics
Description: highest level in false alarm rejection. With multiple sensitivity levels and output options, the X3301 is the logical choice for flame detection in a wide range of hazardous applications. From refineries to turbines, offshore exploration/production to hangars, FPSO’s to fuel storage, let the
- Maximum Response Time: 18 seconds
- Maximum Detector Range (Sensitivity): 210 ft
- Operating Temperature: -40 to 167 F
- Features: Adjustable Time Delay, Automatic Self-test, Explosion Proof, NEMA 4 Rated Enclosure, Other
-
Supplier: Emerson Automation Solutions – Rosemount
Description: Highly efficient dual band detector that is sensitive to UV and IR radiation, can be used indoors and outdoors to detect hydrocarbon-based flames with robust false alarm immunity. Maximize Asset Coverage Eliminate “blind spots” and cost-effectively cover more of your facility Identify
- Maximum Response Time: 5 seconds
- Maximum Detector Range (Sensitivity): 215 ft
- Operating Temperature: -67 to 185 F
- Features: Adjustable Time Delay, Automatic Self-test, Other
-
Supplier: Accuris
Description: Electronic flame safeguards and flame detectors
-
Supplier: Accuris
Description: SWITCH, FLAME DETECTOR
-
Supplier: Accuris
Description: Flame Detectors
-
Supplier: Accuris
Description: FLAME DETECTORS
-
Supplier: Emerson Automation Solutions – Rosemount
Description: field with accurate, real-time flame detection Operate at your full potential Enhanced false alarm immunity helps you reduce downtime and increases efficiency Specifications and Features Multi-spectrum Design: Monitor broad range of hydrocarbon gases Highest immunity to false alarms Multiple
- Maximum Response Time: 5 seconds
- Maximum Detector Range (Sensitivity): 215 ft
- Operating Temperature: -67 to 185 F
- Features: Adjustable Time Delay, Automatic Self-test, Other
-
Supplier: Emerson Automation Solutions – Rosemount
Description: Reliable flame detection coverage in any hazardous area provides a more holistic view of your facility Specifications and Features Ultraviolet Infrared Design Monitor broad range of hydrocarbon and hydrogen gases Dual-band sensor for enhanced false alarm immunity Multiple output options for
- Maximum Response Time: 3 seconds
- Maximum Detector Range (Sensitivity): 66 ft
- Operating Temperature: -67 to 185 F
- Features: Adjustable Time Delay, Automatic Self-test, Other
-
Supplier: Emerson Automation Solutions – Rosemount
Description: Multi-spectrum infrared sensing technology detects ‘invisible’ hydrogen fires at long distances with high false alarm immunity. Optimize Safety Coverage Long range detection of hydrogen based fires Operate at your full potential Enhanced false alarm immunity helps you reduce downtime and increase
- Maximum Response Time: 3 seconds
- Maximum Detector Range (Sensitivity): 66 ft
- Operating Temperature: -67 to 185 F
- Features: Adjustable Time Delay, Automatic Self-test, Other
-
Supplier: Siemens Analytical Products
Description: Gas analyzers with an FID (flame ionization detector) are well suited for the continuous total hydrocarbon measurement. In the first approach, the measuring result is proportional to the number of C-atoms in the relevant molecule. The FIDAMAT versions cover a wide range of
- Operating Temperature: 41 to 113 F
- Measurement Type: %Volume
- Electrical Outputs: Analog Current, Switch
- Features: Audible or Visual Alarms, Self Calibration
-
Supplier: Control Instruments Corp.
Description: For parts-per-million or mg/NM3 measurement of VOC's from oxidizer exhausts, stacks, adsorption beds, and process vents. Direct mount design eliminates heat-traced lines Heated to 200C to prevent sample condensation Stand-alone design with built-in alarms and relays Reliable air-aspirated
- Response Time: 1.2 seconds
- Operating Temperature: -40 to 149 F
- Operating Humidity: 0 to 100 %
- Application: Ambient Air Monitoring, Continuous Emissions Monitoring, Process Gas
-
Supplier: Spectrex, Inc.
Description: The 20/20R Single IR Flame Detector detects hydrocarbon-based fuel and gas fires using advanced flame analysis tools. The detector provides early warning of flaming fires working at 4.4 µm for maximum sensitivity and immunity to false alarms from IR sources such as
-
Description: imaging-based flame detectors). This PAS is applicable to the type selection, design, installation, commissioning, inspection, maintenance and acceptance of the radiant energy sensing flame detectors, which monitor the flame status of burners
-
Supplier: Electro Optical Components, Inc.
Description: Micro-Hybrid Electronic GmbH produces high performance pyroelectric detectors and NDIR gas sensors, as well as thermopile infrared detectors and IR sources. View the Micro-Hybrid video at the bottom of this page. Pyroelectric detectors are available in voltage and in current
- Responsivity: 2 to 275 mV/µW
- Detectivity: 2.2 to 4.32 10^8cmHz^(½)/W
- Category: Sensor / Transducer
-
Supplier: Newark, An Avnet Company
Description: IR2 FLAME DETECTOR SST STEELTALENTUM STAINLESS STEEL
-
Supplier: Newark, An Avnet Company
Description: IR2 FLAME DETECTOR BLUETALENTUM DIE CAST ALLOY
-
Supplier: Newark, An Avnet Company
Description: UV/IR2 FLAME DETECTOR SSTTALENTUM STAINLESS STEEL
-
Supplier: Newark, An Avnet Company
Description: IR3 FLAME DETECTOR BLUETALENTUM DIE CAST ALLOY
-
Description: Fire detection and alarm systems -- Part 10: Point-type flame detectors
-
Supplier: ASTM International
Description: This practice is intended as a guide for the use of a flame photometric detector (FPD) as the detection component of a gas chromatographic system. The different principles of flame photometric detectors, and detector construction are presented in details. The
-
Supplier: Hamamatsu Photonics Europe
Description: The UVTRON ultraviolet ON/OFF detector that makes use of the photoelectric effect of metal and the gas multiplication effect. It has a narrow spectral sensitivity of 185 nm to 300 nm, being completely insensitive to visible light. Unlike semiconductor detectors, it dose not require
- Operating Temperature: -40 to 257 F
- Device Classification: Sensor
- Sensor Technology: UV Detector Only
-
Supplier: CSA Group
Description: ISO 19292:2014 specifies requirements, test methods, and performance criteria for point-type, resettable flame detectors that operate using radiation from a flame, for use in fire detection systems installed on ships. ISO 19292:2014 references ISO 7240-10 for requirements common
-
Supplier: Takex America, Inc.
Description: Description 30m (66ft) Outdoor Battery Operated Flame Sensor for Wireless Systems Wires are no longer necessary - substantially reduce installation costs! High sensitivity flame sensor with ultra-low current consumption plays a crucial role for wireless fire-watching systems. Features
- Maximum Detector Range (Sensitivity): 33 ft
- Device Classification: Sensor
- Sensor Technology: UV Detector Only
-
Description: because there are no background radiation effects that could provide a false flame on condition. All of the functionality of the SPECTRA PRO is easily programmable using AMETEK's AmFlame PC interface software. In addition to configuration, AmFlame provides real time monitoring of the
-
Supplier: ASTM International
Description: flame burner and a dc biased electrode system. 1.3 This recommended practice covers the performance of the detector itself, independently of the chromatographic column, the column-to-detector interface (if any), and other system components, in terms that the analyst can use to
-
Supplier: Takex America, Inc.
Description: Flame sensor FS-6000 immediately detects ultraviolet rays contained in flames and outputs a warning message and activates an external output. The sensor and speaker combined body can be installed either indoors or outdoors.
- Maximum Detector Range (Sensitivity): 33 ft
- Device Classification: Sensor
- Output Options: Switch or Alarm
- Sensor Technology: UV Detector Only
-
Supplier: Radwell International
Description: DISCONTINUED BY MANUFACTURER, DETECTOR FLAME, SHARPEYE, .15AMP, 18-32VDC. FREE 2 YEAR RADWELL WARRANTY
-
Supplier: Radwell International
Description: FLAME DETECTOR, SINGLE FREQUENCY IR. FREE 2 YEAR RADWELL WARRANTY
Find Suppliers by Category Top
Featured Products Top
-
. Observe how MSA's flame detectors are designed to respond to the presence of flame, demonstrating their intended functionality under controlled conditions. Topics Covered Include: Review of facility (read more)
Browse Flame Detectors Datasheets for MSA Safety -
When timing matters, MSA’s Need It Now Program is designed to help meet demanding project schedules. A selection of our most widely used gas and flame detectors is available with reduced lead times, including commonly specified models of the ULTIMA® X5000 Gas Monitor (read more)
Browse Flame Detectors Datasheets for MSA Safety -
The FieldServer FGFD ProtoAir Gateway gives you the flexibility to stay connected to your fixed gas and flame detectors when you’re away from the facility or (read more)
Browse Gas Instruments Datasheets for MSA Safety -
(hydrocarbons) burn with very high flame temperatures, an external fire detection system that can rapidly sound an alarm in the event of a fire is essential to protect human lives and valuable equipment. As a safety professional, you want to purchase flame detectors that best meet your (read more)
Browse Flame Detectors Datasheets for MSA Safety -
-made components on more than 1.600 m² of clean room space – especially pyroelectrical infrared detectors – for clients worldwide. The product range includes analogue single and multi-channel detectors as well as digital multi-channel detectors (PyrIQ). The detectors are used, for example, in gas analysis, fire and flame sensors and spectroscopy. (read more)
Browse Gas Sensors Datasheets for InfraTec GmbH -
The FL500 UVIR Flame Detector delivers high speed flame detection with increased false alarm immunity in a compact design. The FL500 UV/IR Flame Detector monitors for radiation emitted by a flame in both the ultraviolet (UV) and infrared (IR) spectral ranges. By (read more)
Browse Flame Detectors Datasheets for MSA Safety -
to Control Instruments for a solution and decided on the Model SNR650, Flame Ionization Detector. (read more)
Browse Gas Instruments Datasheets for Control Instruments Corp. -
-of-the-art Observer-i Ultrasonic Gas Leak Detector sets a new global industry standard in highly reliable ultrasonic gas leak detection with unprecedented suppression of false alarms. With the incorporation of ANN technology, the breakthrough Observer-i Detector makes (read more)
Browse Gas Instruments Datasheets for MSA Safety -
control platform is compatible with multiple bus communication interfaces: Modbus TCP/IP, HART, EtherNet/IP and optional Modbus RTU. The powerful SENTRY io Controller automatically recognizes MSA’s HART-enabled gas and flame sensing detectors: ULTIMA® X5000 Gas (read more)
Browse Gas Instruments Datasheets for MSA Safety -
The IR5500 open path gas detector continuously monitors for flammable gas leaks over large open areas. It monitors in both the LEL-m and ppm-m ranges to detect both small and large leaks. The IR5500 offers the benefits of early detection with its high sensitivity to gas concentrations at the ppm (read more)
Browse Gas Instruments Datasheets for MSA Safety
Conduct Research Top
-
Flame Detector Maintenance
Precaution - Flame detector installation and maintenance
-
Selecting a Flame Detector
Process and plant engineers working in hazardous environments require continuous flame monitoring equipment to prevent catastrophic fires. In order to select such detection equipment, users should endeavor to understand the principles of flame detection and review the types of detectors available
-
Applying Neural Network Technology To Next Generation Flame Detectors
Accurate and reliable industrial flame monitoring has always represented a technical challenge. The main flame monitoring concern lies in the requirement to differentiate spectral radiation emitted by flames from that of background radiation, which is always present in the industrial environment
-
Safety Monitoring
flame detectors and gas monitoring systems
-
Flame Test
Detectors testing method
-
Flammability Analyzers Versus Flame Ionization Detectors for Process Applications
Why have so many fires and explosions occurred in industrial processes that were believed to have adequate protection against such hazards?
-
Flare Gas Monitoring Systems (.pdf)
automated remote monitoring on a 24/7 basis in virtually any weather. In addition, IR cameras avoid many of the technical and cost-related problems associated with other technologies such as ultraviolet (UV) flame detectors, flame ionization spectrometers, thermocouples, and pyrometers.
-
Solvent Recovery Case History (.pdf)
This case history describes how a customer used the SNR650 Flame Ionization Detector to monitor the switching of its carbon beds in a solvent recovery system for optimum performance.
-
Electrical Barrier Material - Voltoid (R) D-100 FR
Voltoid (R) D-100 FR is a flame-resistant electrical and mechanical barrier material. It has good physical strength and electrical insulating characteristics and is intended for formed or flat parts that require resistance to flame, such as smoke detector insulation, microwave oven air duct
More Information Top
-
https://customer.honeywell.com/resources/techlit/TechLitDocuments/95-0000s/95-8269.pdf
C7076A,D Adjustable Sensitivity Ultraviolet Flame Detectors .
-
Countries > México > Nacional > Traducciones Inglesas / English Translations > English Translations > Secretary of Labor and Social Welfare > STANDARDS > ...
The collected vinyl chloride is then desadsorbido with disulfuro of carbon and the resulting solutions are analyzed by gas chromatography with an ionized flame detector .
-
https://customer.honeywell.com/resources/techlit/TechLitDocuments/60-0000s/60-2398.pdf
C7012A,C,E,F,G Solid State Purple Peeper® Ultraviolet Flame Detectors .
-
https://customer.honeywell.com/resources/techlit/TechLitDocuments/60-0000s/60-0770.pdf
Do not connect more than two C7012E,F or C7076A Ultraviolet Flame Detectors (with self-checking shutter) in parallel to the same terminals.
-
https://customer.honeywell.com/resources/techlit/TechLitDocuments/65-0000s/65-0156.pdf
C7024E,F 24 Vdc Solid State Purple Peeper® Ultraviolet Flame Detectors .
-
https://customer.honeywell.com/resources/techlit/TechLitDocuments/60-0000s/60-2026.pdf
The C7027A, C7035A, C7044A and C7927A Minipeeper® Ultraviolet Flame Detectors detect the ultraviolet radiation emitted by combustion flames.
-
https://customer.honeywell.com/resources/techlit/TechLitDocuments/70-0000s/70-8313.pdf
9 Use with existing Honeywell Flame Detectors .
Indicates content that may require registration and/or purchase.