Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: CHINO Works America Inc.
Description: These testing equipment are for the fields of performance/evaluati on tests of fuel cells, and are applicable to from fundamental research such as element research, material research and single-cell/module research to practical application test. CHINO offers
- Energy Storage Products Tested: Fuel Cells, Materials / Components
- Features: Alarm / Relay, Automated Operation, Specialty / Other
- Form: Test Station / System
- Functions / Module Types: Test Controller / Control Panel, Data Collection / IO, Electronic Load / Load Bank, Gas Supply Module, Monitor / Meter (Measure), Moisture / Humidity Module, Temperature Controller (Oven / Chiller)
-
Supplier: Marposs Corp
Description: DESCRIPTION The OCV Test Bench is designed and conceived to carry out performance tests on fuel cell stacks. It consists in letting the DUT off (no external load is connected to its busbar), but feeding it with reactants: hydrogen at the anode side, air at the cathode
- Energy Storage Products Tested: Fuel Cells
- Form: Test Station / System
- Test Capability: Performance / Functional Test
-
Supplier: Marposs Corp
Description: Easy access to process circuit by way of front doors Configurable HMI touch screen interface Push button panel and light signals for easiness of the operator High accuracy of the system RFID System and Datamatrix reader for traceability purposes Test
- Energy Storage Products Tested: Fuel Cells
- Form: Test Station / System
- Test Capability: Performance / Functional Test
-
-
Supplier: Marposs Corp
Description: DESCRIPTION Double station Emptying/Filling test for PEMFC SAM (Stack Assembly Module), Single Stack and Two Single Stacks, with manual loading/unloading (a console provided by the customer allows the integration of the DUT with the test bench) Principle of measurement
- Energy Storage Products Tested: Fuel Cells
- Form: Test Station / System
- Test Capability: Performance / Functional Test
-
Supplier: Marposs Corp
Description: DESCRIPTION The machine provides one station assembled on aluminium profile frames, covered by removable panels. It is mainly composed of a furnace, which main body slides horizontally in order to manually enclose the stack to be tested. Automatic closing (by pneumatic or
- Energy Storage Products Tested: Fuel Cells
- Form: Test Station / System
- Test Capability: Performance / Functional Test
-
Supplier: CHINO Works America Inc.
Description: The equipment is PEFC type short stack evaluation test equipment consisted of gas supply line, moisturizing line, cooling line, cell performance line and safety line.
- Current: 0.0 to 1560 amps
- Energy Storage Products Tested: Fuel Cells
- Features: Test Software / Computer Interface, Specialty / Other
- Form: Test Station / System
-
Supplier: BTECH, Inc.
Description: The CellQ 2 is a Battery Monitoring System designed for use in Enterprise, Government and Industrial markets which rely on mission critical DC plants to ensure uninterrupted back up power to critical equipment. The CellQ2 is designed for both vented lead acid and valve regulated
- Form: Test Module / Sub-system
- Test Capability: Charge / Condition, Impedance / AC Testing
- Voltage: 2 to 480 volts
-
Supplier: BTECH, Inc.
Description: Remote Telecommunications, UPS systems, Station Battery systems and Switchgear and is competitively priced while offering increased sensitivity, accuracy and repeatability. Key System Features The CellQ 1 will record and trend unit voltage, unit impedance, pilot
- Form: Test Station / System
- Test Capability: Charge / Condition, Impedance / AC Testing
- Voltage: 2 to 60 volts
-
Supplier: SAE International
Description: fuel cell system (FCS) are provided. Fuel processor subsystems (FPS) include all components required in the conversion of input fuel and oxidizer into a hydrogen-rich product gas stream suitable for use in fuel cells. Performance of the fuel
-
Supplier: SAE International
Description: fuel cell system (FCS) are provided. Fuel processor subsystems (FPS) include all components required in the conversion of input fuel and oxidizer into a hydrogen-rich product gas stream suitable for use in fuel cells. Performance of the fuel
-
Description: Provides test methods which are required for the performance evaluation of micro fuel cell power systems for laptop computers, mobile phones, personal digital assistants, etc. Describes the performance test methods for power characteristics, fuel consumption
-
Description: IEC 62282-3-201:2013 provides test methods for the electric/thermal and environmental performance of small stationary fuel cell power systems that meet the following criteria: - output: nominal electric power output of less than 10 kW; - output mode: grid-connected/indep
-
Description: IEC 62282-3-201:2017 provides test methods for the electrical, thermal and environmental performance of small stationary fuel cell power systems that meet the following criteria: - rated electric power output of less than 10 kW; - grid-connected/indep endent operation or
-
Description: IEC 62282-6-200:2012 provides test methods which are required for the performance evaluation of micro fuel cell power systems for laptop computers, mobile phones, personal digital assistants, cordless home appliances, TV broadcast cameras, autonomous robots, etc.
-
Supplier: Venable Instruments
Description: ambient temperature range of 0°C to 50°C, making them ideal for use in harsh environments Scalable system Scalability Test multiple cells simultaneously in a multi-node environment, easily upgrade to increase testing capacity as your application needs evolve Advanced
- Energy Storage Products Tested: Specialty / Other
- Form: Test Station / System
- Test Capability: Charge / Condition, Impedance / AC Testing, Other
-
Supplier: ASME
Description: This Code provides test procedures, methods and definitions for the performance characterization of fuel cell power systems. Fuel cell power systems include all components required in the conversion of input fuel and oxidizer into output
-
Supplier: ASME Standards and Certification
Description: This Code provides test procedures, methods and definitions for the performance characterization of fuel cell power systems. Fuel cell power systems include all components required in the conversion of input fuel and oxidizer into output
-
Supplier: Intepro Systems
Description: recycled. This significantly reduces large energy bills associated with testing using conventional system loads. With multi-drop interfaces, the software can control and monitor up to 32 LoadSaver units and hence up to 320 individual load channels, managed and displayed to a user
- Features: Automated Operation, Power Management / Control, Test Software / Computer Interface
- Form: Test Station / System
- Functions / Module Types: Data Collection / IO, Electronic Load / Load Bank
- Test Capability: Endurance / Life Testing, Other
-
Supplier: SAE International
Description: This paper focuses on the virtual integration and test approach used for the evaluation of an automation system developed for the multifunctional operation of fuel cells in commercial aircraft. In order to accomplish the virtual integration a model of the overall
-
Supplier: SAE International
Description: This recommended practice is intended to provide a framework for performance testing of fuel cell systems (FCS's) designed for automotive applications with direct current (DC) output. The procedures described allow for measurement of performance relative to claims by
-
Supplier: BTECH, Inc.
Description: BTECH Monitors Key Battery Parameters in Real Time: System Voltage, Float, Charge and Discharge Current, plus ambient and pilot cell temperatures Programmed Cell Impedance Measurement: Up to 24x / Day Programmable Test & Out-of-Limits Alarms Battery Discharge Data
- Form: Test Station / System
- Test Capability: Charge / Condition
-
Supplier: Kikusui America, Inc.
Description: measurement with AC impedance method, KFM2150 system provides IR measurement with current interrupt method. Application software enables test for each characteristic of fuel cell such as I-V characteristics, Constant Current characteristics, Current Interrupt method and
- Current: 132 amps
- Energy Storage Products Tested: Fuel Cells
- Features: Test Software / Computer Interface
- Form: Portable / Handheld Tester
-
Supplier: Accuris
Description: Fuel cell technologies - Part 3-201: Stationary fuel cell power systems - Performance test methods for small fuel cell power systems
-
Supplier: Accuris
Description: Fuel cell technologies Part 3-201: Stationary fuel cell power systems - Performance test methods for small fuel cell power systems
-
Supplier: Accuris
Description: Fuel cell technologies \x96 Part 3-201: Stationary fuel cell power systems \x96 Performance test methods for small fuel cell power systems
-
Supplier: Accuris
Description: Fuel cell technologies Part 3-201: Stationary fuel cell power systems \x97 Performance test methods for small fuel cell power systems
-
Supplier: CSA Group
Description: IEC 62282-3-201:2017 provides test methods for the electrical, thermal and environmental performance of small stationary fuel cell power systems that meet the following criteria: - rated electric power output of less than 10 kW; - grid-connected/indep endent operation or
-
Supplier: Venable Instruments
Description: ambient temperature range of 0°C to 50°C, making them ideal for use in harsh environments Scalable system Scalability Test multiple cells simultaneously in a multi-node environment, easily upgrade to increase testing capacity as your application needs evolve Advanced
- Current Test Range: 1 to 5 amps
- Form Factor: Test Station / System
- Input Current: 2.50E-8 milliamps
- Test Capability: Voltage, Current, Other
-
Description: ISO 16110-2:2010 provides test procedures for determining the performance of packaged, self-contained or factory matched hydrogen generation systems with a capacity less than 400 m3/h at 0 °C and 101,325 kPa, referred to as hydrogen generators, that convert a fuel to a
-
Supplier: CANNON Instrument Company
Description: includes maintenance-free, self-lubricating gears and the continuously monitored lubrication of the piston. Since ERAVAP ONLINE measures according to the latest vapor pressure standards and its measurement cell is based on eralytic's laboratory systems, results from ERAVAP ONLINE are
- Tested Fuel: Fuel Oil
-
Supplier: Froude, Inc.
Description: application. It is normally bolted permanently to the test cell floor and has a machined top surface to accept the various components common to all 2000 systems. 2000 Skid The 2000 Skid comprises a fabrication 1.5m wide and up to 3m long depending on the application. It has two
- Test Applications: Specialty / Other
- Type: Test Stand
-
Supplier: DigiKey
Description: SINGLE-CELL BATTERY FUEL GAUGE W
- Form Factor: Test Module / Sub-system
-
Supplier: HORIBA Instruments, Inc.
Description: VETS ONE consists of three major components: Test Request Computer (Windows-based operating system) to request and evaluate emission tests. The VETS ONE application running on this computer contains a complete representation of the test-cell devices and options.
-
Supplier: Oneida Research Services, Inc.
Description: Oneida Research Services offers advanced analytical testing services for the microelectronics, telecommunications, aerospace, automotive, medical and defense industries. Throughout our 40 years of providing materials analysis services to the electronics industry, Oneida Research Services
- Capabilities: Assays / Quantitative, Cleanliness Monitoring / Testing, Environmental Exposure Testing, Environmental Testing and Analysis Services, Failure Analysis, Field Sampling, Quality / Purity (Contamination - Alloys, Polymers, etc.), Report Preparation, Standards Testing /
- Industry Applications: Aerospace / Aviation, Automotive, Chemical / Material Processing, Food / Beverage, Health Care / Medical, Marine, Military, Nuclear / Utility, Pharmaceutical / Biotech, Packaging, Piping / Pressure Vessel, Semiconductors / Electronics, Specialty / Other
- Materials: Adhesives / Sealants, Ceramics / Glass, Chemicals, Coatings, Composites, Concrete / Mortar, Fuel Cell / Battery Materials, Gases, Inorganics, Metals, Nanomaterials, Paper, Plastic / Rubber, Polymers / Organics, Powders, Thin Films / Plating, Wafers / Surfaces, Welds / Joints
- Regional Preference: North America, United States Only, Northeast US Only, Europe Only
-
Supplier: Zotefoams, Inc.
Description: ZOTEK® F Insulation Construction & Electronics Grades F35 F40 HT (High Temperature resistance up to 160?C / 320?F) F75 HT F40 HT LS (High Temperature, Low Smoke) (listed to UL 723/ ASTM E-84 “Standard Method of Test of Surface Burning Characteristics of Building Materials”)F42 HT LS Used in
- Features: Chemical / Fuel Resistant, Electrical Insulation / Dielectric, Flame Retardant, Thermal Insulation
- Foam Type: Closed Cellular
- Form / Shape: Fabricated Shapes
Find Suppliers by Category Top
Featured Products Top
-
design and development; Flexibility and the ability to perform on-demand testing as required, prior to purchasing high productivity systems. Marposs' full testing service package not only helps customers validate their fuel cell component (read more)
Browse Fuel Cell and Solar Test Equipment Datasheets for Marposs Corp -
Download Brochure E-MOBILITY & ENERGY INDUSTRY Testing Of Fuel Cells and Electrolyzers Top (read more)
Browse Leak Testing Equipment Datasheets for Marposs Corp -
Technologies’ high-performance solutions are used both within the fuel cell stack and in the balance of the plant, including energy storage systems, to improve efficiency and profitability. And fuel cell developers rely on Conax solutions to help get their products to market faster. Wind and (read more)
Browse Feedthroughs Datasheets for Conax Technologies -
Electrical Test ELECTRICAL TEST BENCH FOR PEM FUEL CELLS STACK ASSEMBLY HeTECH/Marposs, thanks to its long-term experience in industrial quality control, proposes many customized solutions in order to verify the correct (read more)
Browse Fuel Cell and Solar Test Equipment Datasheets for Marposs Corp -
(on a weighbridge) to measuring the force required to insert one component into another. Load cells (or force sensors) are very often used in conjunction with LVDT displacement transduccers so that the properties of a test sample can be measured (so how far it extends for a given force (read more)
Browse Load Cells Datasheets for RDP Electrosense -
-leading experts. As the world’s largest independent testing company to the global Aerospace sector, Element is unrivaled in our scale, complexity and flexibility of test systems, rigs and test cells. Indoor and outdoor facilities dedicated to Aerospace Product Qualification Testing (PQT) are (read more)
Browse Certification Services Datasheets for Element Materials Technology -
sources such as wind power or solar cells instead of fossil fuels allows CO2-free Energy production. Testing in a hydrogen environment Hydrogen-related technologies (read more)
Browse Environmental Exposure (Climatics) Testing Services Datasheets for Element Materials Technology -
input and output ranges | Isolation up to 1000 V Isolation is also critical in applications requiring sensitive measurements, such as battery monitoring or hydrogen fuel cell systems. In these contexts, isolation ensures that noise and interference do not corrupt data (read more)
Browse Signal Conditioners Datasheets for Knick Interface LLC -
-scale wind, solar and fuel cell systems. Other applications include UPS, switching power supplies and large motor drives. The series consists of 12 values in 4 case sizes, is RoHS compliant, and meets IEC 61071 and UL94V-0. Each unit passes through CDE's industry-leading 100% burn-in testing. (read more)
Browse Datasheets for Cornell Dubilier -
studies like catalyst testing, atmospheric chemistry, and fuel cell evaluation. Core Components of a Custom Permeation System Every permeation system contains a few essential components, which can be tailored depending on research needs (read more)
Browse Permeation Instruments Datasheets for Environics, Inc.
Conduct Research Top
-
The Advantages of Mass Flow Meters & Controllers in Fuel Cell Test Stands (.pdf)
Fuel cell engineers use test stands to simulate the performance of fuel cells. The challenge is to mimic reality and determine the optimum fuel mixture and temperature, while also examining failure mechanisms. Another objective is to test the performance of anode/cathode materials, catalysts
-
Case Study: Organization Chooses Water-Cooled Electronic Loads for Hydrogen Fuel-Cell Test
A government-funded research organization based in Asia addresses renewable energy technology, energy efficiency, climate change, and energy policy. Specific areas of focus for the organization include fuel cells and energy storage systems (ESS). For fuel cells, the organization develops core
-
Case Study: Automotive Parts Manufacturer Chooses PLW Series of Electronic Loads for Fuel-Cell Test
An automotive parts manufacturer based in Asia anticipates a future of fuel-cell electric vehicles (FCEVs) that emit zero toxic pollution -- only water. The company is even looking beyond the automobile. In addition to making automotive modules, core parts, and aftermarket service parts as well
-
Efficiently and Easily Test Fuel Cells
Designing and manufacturing quality fuel cells requires characterizing the device and testing device performance
-
Testing Hydrogen Fuel Cell Performance
Researchers at Charles University in Prague, Czech Republic, have successfully used an Equilibar (R) Back Pressure Regulator combined with a Proportion-Air electronic pressure regulator to provide precise control of fuel cell anode and cathode pressure across a wide range of test conditions
-
Turbo Compressors for Fuel Cell Vehicles
The Swiss fuel cell company Swiss Hydrogen is already testing the Celeroton air bearing turbo compressor CT-17.1000.GB with converter CC-120-1000 for the air supply of a 10kW range extender in a Fiat 500.
-
Fuel cell research collaboration with UTBM
Since 2007, a research team at ETH Zurich, from which Celeroton AG spun out of, has been part of a scientific collaboration in the area of fuel cells with the University of Technology of Belfort-Montbéliard (UTBM). This collaboration has lead to the development of a 10 kW fuel cell model coupled
-
Case Study: System Integrator Incorporates Electronic Loads Into Fuel-Cell ATE
fuel cell) technologies, the company offers a variety of ATE systems and related test and measurement equipment.
More Information Top
-
2009 Annual Progress Report: DOE Hydrogen Program, November 2009 (Book)
Stand-alone Hydrogen Generation and Fuel Cell Test System With Water Recirculation Capability Under Development .
-
Hydrogen, Fuel Cells and Infrastructure Technologies Program, 2002 Annual Progress Report
The electronics developed for the project have found dual use with other fuel cell testing systems .
-
Fuel cells seminar
… GORE-CARBEL Carbon Composite Electrodes; GORE-SELECT Fluoroionomer Composite Products 800th # 1 ALPHABETICAL EXOITOR LISTWG Lynntech, Inc. 7610 Eastmark Drive, Suite 105 College Station, 'I'X 77840 409-693-0017 FAx 409-764-7479 Fuel Cell Test System , Model 2110 800th # …
-
Switching and linear power stages evaluation for PEM fuel cell emulation
The PEMFC power system have humidifiers for the oxidant and fuel, and a MTS-150 fuel cell test system [18] that regulates the stack temperature and allows to control the anode–cathode pressure ratio according to the manufacturer specifications.
-
The R&D of Portable PEMFC Test Systems
Abstract—A portable 20W PEMFC fuel cell testing system is designed and reported in this paper.
-
Fuel Cells
WFCTS - Custom made Fuel Cell Test System .
-
Evaluation of Ultra Clean Fuels from Natural Gas
A diagram of the experimental set-up is shown in Figure 3.2.1.2, with the entire fuel cell testing system and measurement equipment shown in Figure 3.2.1.3.
-
http://qspace.library.queensu.ca/jspui/bitstream/1974/7594/3/Allward_Todd_201210_MASc.pdf
29 Figure 15: Thermally regenerative fuel cell testing system .
Indicates content that may require registration and/or purchase.