-
Supplier: Chicago Blower Corporation
Description: Chicago Blower's Direct Drive Industrial fan is a high performance, trouble free fan proven in a multitude of industrial applications. The fan eliminates belt slippage and power loss. Also, there is no belt noise or troublesome belt maintenance. Direct drive
- Air Flow Rate: 15,000 SCFM
- Static Pressure: 432.7871674924572 in H2O
- Media Temperature: 180 F
- Maximum Diameter (Fan or Blower Wheel): 5 to 17 inch
-
Supplier: ASTM International
Description: 1.1 This guide is intended to provide a simple and consistent procedure for the in-situ field measurement of in-duct sound pressure levels in large low pressure industrial air ducts, such as for gas turbines or fans, where considerations such as flow velocity, turbulence or
-
Supplier: Howden
Description: Mixed Flow Fans The mixed flow (or axial impulse) fan is a cost-effective alternative to an axial flow fan in situations where capital cost and resistance to erosion are as important as power consumption. Key benefits A mixed flow fan combines the features of an axial and
- Design: Centrifugal
- Environment: Corrosive Gases, Dirty Air / Gas, Light Solids / Powder / Dust
- Applications / Use: Exhaust Ventilation
- Product Form: Packaged (Complete System)
-
-
Supplier: Howden
Description: Tellus Fans Howden Tellus Variable Pitch Axial Flow Fans - A uniquely designed axial fan providing operating economy, low sound power levels and reliability. When reliability and adaptability are paramount, the Tellus fan is the preferred choice for the most demanding
- Applications / Use: Air Handling Units / HVAC, Exhaust Ventilation
- Design: Axial
- Environment: Clean Air / Gas, Corrosive Gases, Dirty Air / Gas
- Product Form: Packaged (Complete System)
-
Supplier: Central Marine Diesel
Description: This smooth, quiet 1800 RPM LP/Natural Gas set has plenty of power to run your house, business or off-the-grid hunting cabin. This unit includes a V-8 General Motors Industrial 5.0 L 8 cylinder engine, electronic governor (0.5% frequency control), electronic ignition control module,
- Wattage: 49,000 watts
- Voltage: 120 V, 240 V
- Fuel Type: Natural Gas
-
Supplier: AirPro Fan & Blower Co.
Description: The AirPro backward curved centrifugal fan (BCHS) is designed to handle high air volumes at high static pressures. Used to move mostly clean air, our BCHS industrial fan can be used as a forced draft or induced draft fan for a wide range of industrial applications.
- Air Flow Rate: 300,000 SCFM
- Static Pressure: 40 in H2O
- Media Temperature: 1,000 F
- Design: Centrifugal
-
Supplier: Howden
Description: Wind tunnel fans Howden Ventilatoren wind tunnel fans - State of the art wind tunnel fans providing efficiency, control and reliability. From 400 mm diameter fans up to the most modern and biggest axial fans for tunnel ventilation, our delivery program always
- Maximum Diameter (Fan or Blower Wheel): 19.68505 to 366.14193 inch
- Design: Axial
- Environment: Clean Air / Gas, Dirty Air / Gas
- Applications / Use: Exhaust Ventilation
-
Supplier: AirPro Fan & Blower Co.
Description: heat exchangers, and other industrial equipment in the dust collection, power boiler, waste incineration, odor control, paper and pulp, and other air pollution industries. AirPro’s RTHS industrial fans focus on a design that provides a strong, durable product that performs with
- Air Flow Rate: 250,000 SCFM
- Static Pressure: 36 in H2O
- Media Temperature: 1,000 F
- Design: Centrifugal
-
Supplier: AirPro Fan & Blower Co.
Description: impeller and housing widths. As a highly efficient model, the AirPro BIHS industrial fans offer lower sound levels and energy costs than many other fan types. The fan impeller has been designed with a focus on high operating efficiency without compromising high mechanical
- Air Flow Rate: 350,000 SCFM
- Static Pressure: 25 in H2O
- Media Temperature: 1,000 F
- Design: Centrifugal
-
Supplier: Allegro Industries
Description: Perfect for remote locations where electricity is unavailable, this gasoline-powered, 5.7 hp blower offers high flow rates. The 8"ports and steel guards provide safety and the polyethylene housing with built-in handle offers durability and convenience. It is designed with a sturdy metal base
-
Supplier: Chicago Blower Corporation
Description: Leave it to Chicago Blower to take a perfectly reliable fan and offer a quieter, more efficient, less costly alternative. It's the new Design 5120 plenum fan that widens the performance envelope. It simply packs more power in a smaller footprint. The Design 5120 plenum is a rugged
- Air Flow Rate: 190,000 SCFM
- Static Pressure: 424.7871674924572 in H2O
- Media Temperature: 150 F
- Maximum Diameter (Fan or Blower Wheel): 135 to 807 inch
-
Supplier: Ziehl-Abegg Inc.
Description: Specification: Plug fan without housing for medium temperatures up to +250 °C. High efficiency impeller with backward curved blades and rotating diffuser. Square or rectangular fan supporting plates and troughs are available, both with 100mm thermal insulation. Compact construction,
- Air Flow Rate: 34,123.14 SCFM
- Static Pressure: 10.839523521588594 in H2O
- Maximum Diameter (Fan or Blower Wheel): 40.551203 inch
- Design: Centrifugal
-
Supplier: Chicago Blower Corporation
Description: pressure requirements have risen significantly. As these requirements increase, greater levels of energy are needed to force the air or gas through the system. Operating efficiency of the fan has become much more critical. Every dollar saved on the purchase of a less efficient
- Applications / Use: Air Handling Units / HVAC
- Design: Centrifugal
- Environment: Clean Air / Gas, Corrosive Gases
- Product Form: Packaged (Complete System)
-
Supplier: Howden
Description: Straight aerofoil design – the D-Series fan rotates clockwise in the horizontal plane –20°C to +65°C operation – the D-Series fan works in hot and cool industrial environments Polyurethane-coated steel hub – the D-Series fan also has aluminium blade supports and stainless
- Media Temperature: -4 to 149 F
- Maximum Diameter (Fan or Blower Wheel): 312 to 432 inch
- Design: Axial
- Product Form: Bare (No Motor, Controls)
-
Supplier: Chicago Blower Corporation
Description: Direct Drive SQAD/SQBD fans combine the performance and efficiency of Chicago's versatile "Square" Fans with the advantages of a compact directly driven arrangement. With the fan wheel mounted directly onto the motor shaft maximum efficiency is constantly maintained. Belt noise,
- Air Flow Rate: 27,366 SCFM
- Static Pressure: 427.7871674924572 in H2O
- Media Temperature: 180 F
- Maximum Diameter (Fan or Blower Wheel): 8.75 to 30 inch
-
Supplier: Eagle Eye Power Solutions, LLC
Description: The VS-12 explosive and toxic gas ventilation system is a 850 CFM forced fan system used in battery charging rooms and other locations where motive power and stationary batteries are present. The VS-12 can also be used where there is a possibility of other flammable or toxic gasses
- Air Flow Rate: 850 SCFM
- Material of Construction: Aluminum
- Design: Axial
- AMCA Class: Class I
-
Supplier: ebm-papst Inc.
Description: conveying air through heat exchangers. With axial fans, which function similarly to a propeller, the air is conveyed in axial direction in parallel with the rotating motor shaft. The ebm-papst external rotor motor is integrated directly into the axial impeller, forming a compact axial
- Air Flow Rate: 53.53803 SCFM
- Static Pressure: 0.18868800204246813 in H2O
- Media Temperature: 158 F
- Applications / Use: Air Handling Units / HVAC
-
Supplier: Greenheck
Description: Utility Centrifugal Fans The Utility Fans include both direct and belt driven fans. They are self contained units consisting of the fan, motor and drive. Model SWB The SWB is a belt driven fan and features a backward-inclined centrifugal wheel. This fan is
- Air Flow Rate: 70 to 69,000 SCFM
- Static Pressure: 2.5 to 8.5 in H2O
- Applications / Use: Air Handling Units / HVAC, Exhaust Ventilation
- Drive Type: Belt Drive, Direct Drive
-
Supplier: ebm-papst Inc.
Description: Highly efficient fan expertise ebm-papst axial fans are suitable for high air performance with medium pressure increase. The air flows through the fan blades in parallel with the axis of rotation. ebm-papst can supply a wide range of AC and DC fans: from 25 to 280 mm with
- Air Flow Rate: 44.12475 SCFM
- Media Temperature: 14 to 131 F
- Applications / Use: Air Handling Units / HVAC
- Design: Axial
-
Supplier: ebm-papst Inc.
Description: Highly efficient fan expertise ebm-papst axial fans are suitable for high air performance with medium pressure increase. The air flows through the fan blades in parallel with the axis of rotation. ebm-papst can supply a wide range of AC and DC fans: from 25 to 280 mm with
- Air Flow Rate: 5.8833 SCFM
- Media Temperature: -4 to 158 F
- Applications / Use: Air Handling Units / HVAC
- Design: Axial
-
Supplier: Fläkt Woods Group SA
Description: Due to its size and motor power, Ropera fans are suitable for most low volume low to medium pressure ducted applications. These are typically found as boost fans within long duct runs and trickle extract fans due to the nature of them moving the air inline with the axis of the
- Air Flow Rate: 1,186.57392 to 1,377.2733 SCFM
- Static Pressure: 3.613174507196197 in H2O
- Maximum Diameter (Fan or Blower Wheel): 3.93701 to 12.4015815 inch
- Applications / Use: Air Handling Units / HVAC
-
Supplier: Berner International Corporation
Description: fan directs a high velocity stream of heated air towards the door opening. The hot air mixes with the incoming cold air providing a warm comfortable environment. The door heater is activated through a limit switch. When the door is opened there is a brief pre-purge and safety function check.
- AC Voltage Required: 208 to 480 volts
- Maximum Air Flow: 6,500 to 7,900 SCFM
- Heater Type: Air Heater
- Features: Electric, Natural Gas / Propane
-
Supplier: Safran Electrical & Power
Description: Weight (kg): 2 Noise (dBA): Acoustic pressure input: 74 Acoustic pressure output: 77 Radiated acoustic pressure: 64 Current (A): 15 Flow rate (l/s): 70 Pressure (hPa): 15 Max. operating temperature (°C): -40°C / +70°C Electrical power (W): 420 Speed regulation: Multi-speed Voltage (V): 28 Frequency
- Air Flow Rate: 148.321600230252 SCFM
- Static Pressure: 6.021957511993689 in H2O
- Media Temperature: -40 to 185 F
- Applications / Use: Air Handling Units / HVAC
-
Supplier: LTG Incorporated
Description: squirrel cage impellers. Fans in the VRK series are generally used at pressures of up to 8.03 'wg, and achieve volumetric flows of up to 58 858 cfm. These fans too are available with either single or double-sided intake, various drive types and a wide range of accessories.
- Air Flow Rate: 2,060 to 32,372 SCFM
- Static Pressure: 8.029276682658205 to 8.832204350924044 in H2O
- Maximum Diameter (Fan or Blower Wheel): 11.02 inch
- Applications / Use: Air Handling Units / HVAC
-
Supplier: Robinson Fans
Description: Robinson Backward Curve (BC) industrial fans represent a versatile fan series for quiet, high efficiency service. The Backward Curve design, for forced or induced-draft service, is used for a wide range of applications in many industries. BC fans are engineered and built
- Air Flow Rate: 1,000,000 SCFM
- Static Pressure: 120 in H2O
- Maximum Diameter (Fan or Blower Wheel): 180 inch
- Applications / Use: Air Handling Units / HVAC, Exhaust Ventilation, Materials Handling / Pneumatics
-
Supplier: Rosenberg USA
Description: GKHM 560-CEG.160.6NA IE ULH Ultra-Low Harmonics (ULH) EC fans with active Power Factor Correction (PFC). 560-mm backward curved module Part no.: N88-56605; 8,000 CFM @ 4 inWG.
- Air Flow Rate: 11,000 SCFM
- Maximum Diameter (Fan or Blower Wheel): 22.047256 inch
- Applications / Use: Air Handling Units / HVAC
- Environment: Clean Air / Gas
-
Supplier: Caterpillar Oil & Gas
Description: Cooling System Radiators Non-sparking blower fan Blower fans for customer supplied radiators Fan drives for customer supplied radiators ATAAC conversion Aftercooler Expansion tank Heat exchangers Exhaust System Flexible fittings Elbow Flange Pipe Rain cap Muffler Fuel System
- Horse Power: 215 to 325 HP
- Displacement: 14.600862316975304 liters
- Fuel Type: CNG
- Application: Industrial
-
Supplier: Caterpillar Oil & Gas
Description: lift, gas gathering, and wellhead gas compression. Cat G3408 gas engine. Ratings: 190-298 bkW (255-400 bhp) @ 1800 rpm are NSPS site compliant capable with customer-provided air-fuel ratio control and aftertreatment or available for non-regulated areas. Engine Design - Improved
- Horse Power: 255 to 400 HP
- Displacement: 18.009368896022288 liters
- Fuel Type: CNG
- Application: Industrial
-
Supplier: Ziehl-Abegg Inc.
Description: Specification: Single and double inlet A series motorised impellers are designed for use in standard scrolls. The impeller diameters and power ranges correspond to the respective RG/RD..A scroll housed fan data. Attributes and special features: Optimal motor cooling and a compact construction
- Design: Centrifugal
- Environment: Clean Air / Gas
- Drive Type: Direct Drive
- Applications / Use: Exhaust Ventilation
-
Supplier: LTG Incorporated
Description: fans are available in galvanised steel or optionally in stainless steel. The fans of the TM series come with motors that are flange-mounted on the left or right. The fans in the TW series have a free shaft end that can be driven by a belt drive or as a direct drive with an
- Air Flow Rate: 2,825 to 8,240 SCFM
- Static Pressure: 0.5419761760794308 to 2.4087830047974648 in H2O
- Media Temperature: -40 to 482 F
- Maximum Diameter (Fan or Blower Wheel): 15.75 to 57.54 inch
-
Supplier: Johnson Controls, Inc.
Description: YORK® WALL MOUNTED PROP FANS, incorporating deep-spun inlet scrolls to minimize losses due to fan inlet conditions, perform at a high efficiency. Rugged construction insures long life even in the severest industrial application. Panel Fans, which are capable of moving
- Air Flow Rate: 323,000 SCFM
- Static Pressure: 1.8000000000000003 in H2O
- Applications / Use: Air Handling Units / HVAC, Exhaust Ventilation
- Design: Axial
-
Supplier: Caterpillar Oil & Gas
Description: Producing oil and gas is a complex task that requires specialized power generation equipment. Cat 3500 generator sets with Dynamic Gas Blending offer the lowest owning and operating cost by displacing diesel with low cost gas. They are specifically designed for the oilfield and
- Wattage: 1,600 watts
- Volt-Ampere: 2,000,000 VA
- Frequency: 50 Hz
- Applications: Industrial
-
Supplier: Ziehl-Abegg Inc.
Description: integrating the voltage controllable external rotor motor into the impeller. High power density. Applications: Duct, tube and roof fans, air conditioning units, heat pumps, and for cooling and ventilation purposes
- Air Flow Rate: 9,413.28 SCFM
- Maximum Diameter (Fan or Blower Wheel): 24.803163 inch
- Applications / Use: Air Handling Units / HVAC, Exhaust Ventilation, Product / Process Cooling
- Design: Centrifugal
-
Supplier: Air Control Industries Inc.
Description: Performance Figures Flow Up to 50cfm (85m³/hr) Pressure Up to 23”Wg (57mBar) Noise 53.3 to 64.8dB(A) 1M Free Air Weight 3.5 to 12Kgs Power 37 - 120W Supply Options See attached data sheets for details.
- Air Flow Rate: 56 SCFM
- Static Pressure: 25.693837849807622 in H2O
- Material of Construction: Aluminum
- Design: Centrifugal
-
Supplier: Air Control Industries Inc.
Description: Performance Figures Flow 942cfm (1600M³/hr) Pressure 3.25”WG (8.09mBar) Noise 87dB(A) 1M Free Air Weight 10 Kg Power 0.55 kW Supply Options Various supply options available. Please see attached data sheets for details.
- Air Flow Rate: 942 SCFM
- Static Pressure: 3.247861690702245 in H2O
- Material of Construction: Aluminum
- Design: Centrifugal
Find Suppliers by Category Top
Featured Products Top
-
New York Blower AF Fans extend the pressure capabilities of backward inclined fan designs to the higher pressures found in heavy industrial-process applications such as boiler forced-draft, combustion air, solvent recovery and recirculating air. The AF wheel design has been in production (read more)
Browse Fans and Blowers (industrial) Datasheets for New York Blower Company (The) -
New York Blower's custom-engineered products are designed to exacting specifications. Designs meet specific flow, pressure, temperature, leak integrity, and configuration requirements. Specialty areas include: Configurations - choices range from fan wheels mounted directly on motor (read more)
Browse Fans and Blowers (industrial) Datasheets for New York Blower Company (The) -
New York Blower Duct Fans are designed and constructed for low pressure ventilating and industrial exhaust applications requiring the compactness of an axial fan. In applications where equipment space is at a premium, the compact flow-through design of the Duct Fan can reduce system space (read more)
Browse Fans and Blowers (industrial) Datasheets for New York Blower Company (The) -
New York Blower Plug Fans can be used for a wide variety of OEM applications. Typically, they are used in applications where the system plenum acts as the fan housing, combining versatility with compact design to reduce overall system costs. This is achieved while maintaining operating (read more)
Browse Fans and Blowers (industrial) Datasheets for New York Blower Company (The) -
Avoid making the wrong fan selection for your application by understanding these centrifugal fan (read more)
Browse Fans and Blowers (industrial) Datasheets for New York Blower Company (The) -
The BC fan line has four designs to choose from: BC-15: for applications to 15"WG, wheel diameter 24" to 73" BC-20: for applications to 21"WG, wheel diameter 24" to 89" BC-30: for applications to 31"WG, wheel diameter 24" to 89" BC-40: for (read more)
Browse Fans and Blowers (industrial) Datasheets for New York Blower Company (The) -
New York Blower Vaneaxial Fans are designed for high-pressure ventilation and industrial-process applications where axial flow is desirable and space is at a premium. Uses include heat, smoke, and fume removal; process drying; comfort and process cooling; and general ventilation (read more)
Browse Fans and Blowers (industrial) Datasheets for New York Blower Company (The) -
Square fans come in three backward inclined wheel designs: airfoil, curved blade, and single thickness. They are ideally suited for a wide range of clean-air applications requiring a tight footprint. Typical uses include pneumatic conveying, product drying, product cooling, supply air, and (read more)
Browse Fans and Blowers (industrial) Datasheets for New York Blower Company (The) -
Qualtek AC centrifugal fans are commonly used in HVAC systems, air handling units, and industrial applications where high airflow rates and static pressures are required. They are typically more powerful and efficient than AC axial fans and are better suited for applications that require (read more)
Browse Fans and Blowers (industrial) Datasheets for Qualtek Electronics Corp. -
Systems that generate heat require cooling fans to avoid overheating and subsequent breakdowns. This typically means choosing between a centrifugal fan vs. axial fan. To make the best choice, it’s important to understand how each fan type works and the differences between them. Here (read more)
Browse Fans and Blowers (industrial) Datasheets for Pelonis Technologies, Inc.
More Information Top
-
Fluid Dynamics and Heat Transfer of Turbomachinery Complete Document
Similar arguments are valid for turbo fan , turbo prop, and industrial and power gas turbines.
-
Handbook of Air Conditioning and Refrigeration, 2/e > AIR SYSTEMS: COMPONENTS—FANS, COILS, FILTERS, AND HUMIDIFIERS
Some large industrial fans in power plants are driven by steam or gas turbines.
-
Bookshelf and Unified Agenda > Environmental Protection Agency > Office of Air Quality Planning and Standards > Emission Inventory Improvement Program - Techni...
… 3553 Woodworking Machinery 3554 Paper Industries Machinery 3559 Special Industry Machinery, Nec 3561 Pumps And Pumping Equipment 3562 Ball And Roller Bearings 3563 Air And Gas Compressors 3564 Blowers And Fans 3567 Industrial Furnaces And Ovens 3568 Power Transmission Equipment, Nec 3569 …
-
Electrostatic Precipitation
The medium industrial application experiment was held in Xiang Fan power plant by taking out flue gas from the NO. 6 coal burning boiler.
-
http://dspace.mit.edu/bitstream/handle/1721.1/44700/297407259-MIT.pdf?sequence=2
gas generator core with an industrial low pressure spool that includes the fan and the power .
Indicates content that may require registration and/or purchase.