Products/Services for Interphase Transformer Winding
-
Power Transformers - (1025 companies)...do not provide electrical isolation, but are smaller, lighter, and cheaper than dual winding transformers. These devices are often used to step voltages up from 220-240 V to 110-120 V for residential use. Variable autotransformers (or variacs) provide...Transformer Type / ApplicationCooling MethodMounting / Form Factor -
Single Phase Transformers - (86 companies)...of primary (input) windings to secondary (output) windings determines the change in current. Single-phase transformers with a 1:1 ratio can be used to isolate circuits. Single-phase transformers abide by Ohm's law, and outside of minor inherent loss due...
-
Transformer Winding Services - (151 companies)Transformer winding services design transformers and other magnetics products for application-specific and OEM usage in a variety of industrial, medical, military, aerospace, telecommunications, commercial and specialty applications. Transformer... -
Electrical Coil Winding Machines - (61 companies)Electrical coil winding machines are used to wind coils for motors, transformers, inductors and chokes. Electrical coil winding machines are used to wind coils for motors, transformers, inductors, and chokes. Coil winding equipment is used...
-
Transformers - (2112 companies)...case or enclosure is ventilated to allow airflow, which cools the windings. Encapsulated transformers are special types of dry transformers that utilize a solid resin to encase and seal the core and coils. Fluid-filled transformers immerse the coils...
-
Electrical Winding Services - (357 companies)...winding services fabricate custom-wound assemblies for a wide range of applications, including: automotive. avionics. motor. transformer. medical instrumentation. power generation. An electrical winding service is the first basic step for the generation...
-
Metal Coil Winding and Unwinding Equipment - (121 companies)...transformer coils. choke coils. inductor coils. generator coils. Metal coil unwinders are also used with a variety of products, and may be incorporated into a coil coating line that includes a web unwind or feed section. Metal coil winding...
-
RF Transformers - (127 companies)...from one circuit to another by electromagnetic induction. RF transformers are typically used to increase or decrease the voltage from one side of the transformer to the other. The turn ratio, or the number of windings on the primary and secondary...
-
Flyback Transformers - (32 companies)Flyback transformers (FBT) or line output transformers (LOPT) are designed to produce a very high voltage by storing energy in their magnetic windings. Flyback transformers (FBT), or line output transformers (LOPT), are designed to produce a very...
-
Cast Coil Transformers - (34 companies)Cast coil transformers have windings that are solidly-cast in resin under a vacuum in a mold. This manufacturing process covers the transformer windings in a strong epoxy resin with a high dielectric strength. Cast coil transformers have windings...
Product News
-
New England Wire Technologies Corporation
Double and Triple Insulated Winding Wires and the ground. NEWind (R) Specialty Winding Wire solves this problem by insulating the conductors with thin layers of insulation. Cable insulation layers are extruded in either two layers (Supplementary) or three layers (Reinforced). This design ensures that defects in any one layer will not reduce the insulating ability. The result is motors and transformers that can be manufactured without additional insulation, thus reducing their cost and size. Insulation Colors: Clear. White. Black. Red. Green... (read more)Browse Hookup Wires Datasheets for New England Wire Technologies Corporation -
New England Wire Technologies Corporation
NEWind Double and Triple Insulated Winding Wires . NEWind (R) multi-layer insulated winding wire solves this problem by insulating the conductors with multiple thin layers of insulation. NEWind (R) wire insulation layers are commonly extruded in single, double (supplementary), or triple (reinforced) layers that can reduce creepage and clearing distances. The result is motors and transformers that can be manufactured without additional insulation, thus reducing their cost and size. Common usage/industries: Power conversion. Motors. Domestic... (read more)Browse Litz Wire Datasheets for New England Wire Technologies Corporation -
TPS Elektronik GmbH
Transformers - Three Phase Pad Mounted Transformer The Three Phase Pad Mounted Transformer is a factory direct,American standard (ANSI/IEEE) distribution solution built for safe,stable and efficient power conversion in demanding field installations. Featuring an isolated HV/LV compartment design inside a lockable,outdoor ready cabinet with radiator cooling,it supports a wide rated capacity range from 75 kVA to 3735 kVA. Primary (HV) voltage is customizable from 34.5 kV to 13.8 kV (and other common utility ratings),while secondary (LV) output... (read more)Browse Transformers Datasheets for TPS Elektronik GmbH -
Triad Magnetics
Autotransformer Power Transformers Autotransformer Power Transformers. Triad Magnetics ' autotransformer power transformers are available in single winding step-up transformer models, in which the primary coil is a fraction of the entire winding, and step-down transformer models, in which the secondary coil is a fraction of the entire winding. Standard double wound power transformers feature isolated primary and secondary coils, so all power transfer is conducted by induction. Autotransformers transfer power in between coils... (read more)Browse Power Transformers Datasheets for Triad Magnetics -
Triad Magnetics
Looking for Current Sense Transformers Current sense transformers "transform " AC electrical currents from larger-current values into smaller currents that are better suited for instruments, protective relays, and control circuits. This is achieved by developing a current in the secondary winding that is proportional to that of the primary. The isolation aspect of the transformer keeps the high voltage of the primary system separate from the instrument, safety circuit, or control circuit on the other side, thereby protecting them... (read more)Browse Current Sense Transformers Datasheets for Triad Magnetics -
Coilcraft, Inc.
Current Sense Transformers Sensed current up to 40 Amps. For use between 400 Hz to 1 MHz. Very low primary resistance. AEC-Q200 Grade 1 ( -40°C to +125°C). Meets Reinforced Insulation per UL 60950-1. 4000 Vrms, one minute isolation (hipot) winding to winding. RoHS-compliant. 260°C compatible. Tin-silver-copper over tin over copper over steel (pins 1 - 3); Tin-silver-copper over tin over nickel over copper (pins 4 - 5) terminations (read more) -
Fuji Electric Corp. of America
New Oil Immersed Transformers exceptional reliability. Fuji Electric designs transformers to ensure the highest efficiency without sacrificing cost-effectiveness. Through carefully engineered core construction, we minimize no-load loss. Additionally, by utilizing transposed conductors, preventing magnetization of metal adjacent to the winding, and incorporating magnetic shielding in the tank 's inner wall, we have significantly reduced stray-load loss. As a result, Fuji Electric transformers deliver superior efficiency... (read more) -
Triad Magnetics
Why Transformer Insulation Ratings Matter How Does Temperature Influence the Lifespan of a Transformer?. All electrical devices produce heat as an operational byproduct. In transformers, normal operation causes an internal temperature increase or temperature rise. When the transformer is at its nameplate rating, the transformer temperature rise is the average temperature increase of the windings above the ambient temperature. This increase in temperature has the potential to shorten the transformer 's lifespan. As a result, proper... (read more)Browse Transformers Datasheets for Triad Magnetics -
Triad Magnetics
Designing Effective Current Sense Transformers Design Considerations for Current Sense Transformers. Current sense transformers are instrument transformers designed to detect (i.e., sense) electrical current and convert (i.e., transform) it into a more usable and safe form for the connected device(s). They perform this function by measuring the current flow in the primary winding and producing a proportional current in the secondary winding, enabling the reduction of high-voltage current in the primary winding to a lower value... (read more)Browse Current Sense Transformers Datasheets for Triad Magnetics -
Majestic Transformer Co.
Auto Transformers for Use with American Equipment Majestic Transformer Company's transformers for this application are AUTO-WOUND with a secondary voltage of 110 - 120V and will suit most American domestic appliances. The transformers are enclosed in portable silver grey cases with standard American socket outlets and UK standard cable & plug input, (other European plugs available to order). All units are fused on the input winding. All units have rubber feet and those rated 500VA and above have a carrying handle for convenience. The input... (read more)Browse Autotransformers Datasheets for Majestic Transformer Co.
-
An optimized active interphase transformer for auto-connected 12-pulse rectifiers results in clean input power
Furthermore, in multipulse vstems careful attention to practical aspects such as leakage reactance's in series with each rectifier bridge, interphase transformer winding design and preexisting utility voltage distortion is important for equal current sharing and elimination of harmonics in the input line …
-
Design and Performance Evaluation of a 10-kW Interleaved Boost Converter for a Fuel Cell Electric Vehicle
In addition to the common mode component of current in the interphase transformer windings , equal to I'n(1)2, a second component of current, Id, will flow due to the voltage V,:f, across the total transformer winding.
-
Journal of Energy > Frequency Converter Technology for Aircraft Power Systems
This allows each group to operate in the 3-pulse mode, with the third harmonic component of voltage ripple appearing across the interphase transformer windings .
-
Design and Development of Autotransformer Based 24-Pulse AC-DC Converter fed Induction Motor Drive
TABLE I Interphase transformer winding details Winding Nii .
-
Comparative evaluation of three-phase high-power-factor AC-DC converter concepts for application in future More Electric Aircraft
of the corresponding interphase transformer windings .
-
Comparative evaluation of three-phase high power factor AC-DC converter concepts for application in future more electric aircrafts
… component uMN of the output voltage; (d) mains phase voltage uaN and corresponding input phase voltage ua´N of the line interphase transformer; (e) mains phase current ia and input currents i1a, i2a of the corresponding interphase transformer windings ; (f) output currents i1 …
-
Analysis and simulation of a six-phase generator/rectifier system
where r and L, are the resistance and leakage inductance, respec- tively, of one winding of the two- winding interphase transformer while L, is the magnetizing inductance.
-
Parameter measurement of a six-phase synchronous machine for simulation of machine/converter systems
where r and L, are the resistance and leakage inductance, respec- tively, of one winding of the two winding interphase transformer while L, is the magnetizing inductance.
-
24-pulse ac-dc converter for harmonic mitigation
The interphase transformer is wound using a core of size no. 3 with E-I laminations of size (76 mm  127 mm) and (127 mm  19 mm), respectively.
-
A Novel Polygon Based 18-Pulse AC–DC Converter for Vector Controlled Induction Motor Drives
The interphase transformer is wound using core of size no.3 with E-I laminations of size (76 mm 127 mm) and (127 mm .
Indicates content that may require registration and/or purchase.