Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Hamilton Company
Description: The Microlab 600 is available as a standalone pump with single and dual syringe configurations. The standalone pump offers two communication capabilities—Ethernet and RS-232. Why Choose a Standalone Syringe Pump? Take full command of your diluting and dispensing applications with the Microlab 600
- Capacity: 0.0001000105612969727 to 50 ml
- Accuracy: 1 (+/-%)
- Reproducibility CV: 0.2 (%)
- Operating Temperature: 41 to 104 F
-
Supplier: LabChem Inc.
Description: DILUTING FLUID FOR CSF-500ML LabChem's products consist of aqueous solutions prepared to exact quality standards and certified for use in laboratories performing specified standard methods of analysis. These solutions are often specified by State, Federal, or Commercial Industrial Societies to
-
Supplier: LabChem Inc.
Description: DILUTING FLUID FOR SPERM-500ML LabChem's products consist of aqueous solutions prepared to exact quality standards and certified for use in laboratories performing specified standard methods of analysis. These solutions are often specified by State, Federal, or Commercial Industrial Societies to
-
-
Supplier: Spectrum Chemical Mfg. Corp.
Description: range of ACS chemicals and reagents will always fulfill all your needs, whether you purchase for a laboratory, research institution, pilot plant or full-scale manufacturing facility, we have the quantities you need with the quality you demand.
- Applications: Pharmaceuticals / Drugs
-
Supplier: SAE International
Description: diluted with B20 fuel, where the B20 was prepared with soy methyl ester (SME) B100 with high Rancimat oxidative stability, SME B100 with low oxidative stability, and lard methyl ester (LME). The oils were then subjected to laboratory aging simulating severe drive cycles. At intermediate aging
-
Supplier: CSA Group
Description: Test methods for determining the service performance of enamels are specified, i.e. for determining whether an enamel resists the specified treatment. The procedure insolve treatment for specified periods with an alkine detergent at 80 degrees centigrade and a dilute acid solution at room
-
Description: Test methods for determining the service performance of enamels are specified, i.e. for determining whether an enamel resists the specified treatment. The procedure insolve treatment for specified periods with an alkine detergent at 80 degrees centigrade and a dilute acid solution at room
-
Supplier: ASTM International
Description: 1.1 This guide covers procedures for obtaining laboratory data to evaluate the adverse effects of chemicals associated with soil to nematodes from soil toxicity tests. This standard is based on a modification to Guide E 1676. The methods are designed to assess lethal or sublethal toxic
-
Supplier: ASTM International
Description: 1.1 This guide covers procedures for obtaining laboratory data to evaluate the adverse effects of contaminants associated with soil on earthworms (Family Lumbricidae) from soil toxicity tests. The methods are designed to assess lethal or sublethal toxic effects on earthworms in short-term
-
Supplier: ASTM International
Description: or other fluids whose physical properties would be modified by dilution. 1.2 These test methods are designed and intended for use as a research standard to develop data on the efficacy of repellents applied to the skin of humans against laboratory-reared or field-collected mosquitoes. The use
-
Supplier: ASTM International
Description: or other fluids whose physical properties would be modified by dilution. 1.2 These test methods are designed and intended for use as a research standard to develop data on the efficacy of repellents applied to the skin of humans against laboratory-reared or field-collected mosquitoes. The use
-
Supplier: Cole-Parmer
Description: For use as diluting or rinsing fluid for sterility testing.
-
Supplier: Cole-Parmer
Description: For use as diluting or rinsing fluid for sterility testing.
-
Supplier: Cole-Parmer
Description: Keep your flame photometer system running smoothly with these replacement parts. Parts are for the flame photometers, along with the automatic diluter and autosampler.
-
Supplier: Cole-Parmer
Description: Keep your flame photometer system running smoothly with these replacement parts. Parts are for the flame photometers, along with the automatic diluter and autosampler.
-
Supplier: Advanced Technical Services GmbH
Description: The model ATS LabAssistant™ is designed for the modern and demanding laboratory: it offers simple operation routines increase in analysis quality and productivity lowers the per analysis cost enables laboratories to meet Good Laboratory Practice protocols The ATS LabAssistant™ has
- Injection Volume Range: 5 ml
- Vial/Well Capacity: 80 ml
- Remote Interface: Application Software Included
- Injection Mechanism: Syringes
-
Supplier: Sartorius Lab Instruments GmbH & Co. KG
Description: Vivacon® 500 centrifugal concentrators have been designed for concentration of DNA or proteins and buffer exchange applications with samples up to 500 μl. For optimal performance with very dilute samples, e.g. forensic specimens, Vivacon® 500 is equipped with the patented Hydrosart® regenerated
- Sample Size: 0.5 cc
- Filtration Area: 0.000032 mm²
- Hold Up Volume: 0.005000528064848634 cc
- Filter Medium Material: Cellulose - Regenerated
-
Supplier: Sartorius Lab Instruments GmbH & Co. KG
Description: Vivacon® 2 centrifugal concentrators have been designed for DNA concentration and buffer exchange applications with samples up to 2 ml. For optimal performance with very dilute samples, e.g. forensic specimens, Vivacon® 2 is equipped with the patented Hydrosart® regenerated cellulose membrane that
- Sample Size: 2 cc
- Filtration Area: 0.000095 mm²
- Hold Up Volume: 0.010001056129697268 cc
- Filter Medium Material: Cellulose - Regenerated
-
Supplier: Sartorius Lab Instruments GmbH & Co. KG
Description: Sartobind® Jumbo capsules are ion exchange chromatography devices based on macroporous membranes. They can be used for chromatographic separations in the downstream processing of proteins. The ion exchange ligands are coupled to a membrane which is fitted into a plastic housing for quick handling,
- Pore Size: 3 to 5 µm
- Filtration Area: 550,000 mm²
- Pressure: 58.01508 psi
- Filter Shape: Disc (Circular)
-
Supplier: Sartorius Lab Instruments GmbH & Co. KG
Description: Vivaspin concentrators are disposable ultrafiltration devices for the concentration of biological samples. Vivaspin 2 bridges the gap between the 500 µl and 4 ml centrifugal concentrators. They can effectively be used in swing bucket or fixed angle rotors accepting 15 ml centrifuge tubes. The
- Sample Size: 0.39999999999999997 to 2 cc
- Filtration Area: 0.00012 mm²
- Hold Up Volume: 0.010001056129697268 cc
- Filter Medium Material: Cellulose - Regenerated
-
Supplier: GFS Chemicals, Inc.
Description: ITEM#:99 H2WO4 CAS#:7783-03-1 F.W.:249.86 NFPA#:1-0-0 Specific Gravity: 0.000 DOT:NR Descriptions: Specification TEST 1. Lead 0.005% 2. Insoluble in dilute NH4OH 0.05% 3. Iron 0.003% Properties No properties.
- Function: Reagent
-
Supplier: Alconox, Inc.
Description: Concentrated, anionic detergent for manual and ultrasonic cleaning. Free rinsing to give you reliable results without interfering residues. Extremely mild and completely soluble in hard and soft water. USDA authorized. Dilute 1:100. pH 8.5
- Concentration (As Used, by Volume): 1 %
- Type: Aqueous / Water-based, Cleaner / Cleaning Agent, Degreaser, Detergent / Surfactant, Mild Alkaline Cleaner / Agent (8.5 to 11 pH), Surface Treatment
- Features: Biodegradable, VOC Compliant
- Industry Applications: Biotech (Pharmaceutical / Medical), Critical Cleaning / Cleanroom (Residue Free), Laboratory / Labware
-
Supplier: Restek
Description: Faster and easier than SPE and liquid-liquid extraction: just load, wait 5 minutes, then elute. Effective removal of proteins, phospholipids, and salts. Quick concentration step increases sensitivity. Easy to automate for high-throughput laboratories. Suitable for a wide range of sample matrices
-
Supplier: GFS Chemicals, Inc.
Description: ITEM#:5617 CAS#: F.W.: NFPA#: Specific Gravity: DOT: Descriptions: Kit contains Mehlich III Stock Solution A and Mehlich III Concentrate B. Mix the two solutions with deionized or reverse osmosis water and dilute to the specified volume with water. Specification TEST Properties No properties.
- Function: Reagent, Reference / Chemical Standard
-
Supplier: Twin City Fan & Blower
Description: Application The BCIFE Induced Flow, Centrifugal Exhaust Fan is intended for use in exhausting laboratory fumes and hazardous chemicals in such a manner that diminishes the likelihood of concentrated, contaminant-laden air from being re-entrained into the building's intake or make-up air. This
- Air Flow Rate: 132,000 SCFM
- Static Pressure: 421.7871674924572 in H2O
- Maximum Diameter (Fan or Blower Wheel): 12.25 to 66 inch
- Applications / Use: Air Handling Units / HVAC, Exhaust Ventilation
-
Supplier: Twin City Fan & Blower
Description: Application The QIFE Induced Flow Mixed Flow Exhaust Fan is intended for use in exhausting laboratory fumes and hazardous chemicals in such a manner that diminishes the likelihood of concentrated, contaminant-laden air from being re-entrained into the building's intake or makeup air. This
- Air Flow Rate: 600 to 71,000 SCFM
- Static Pressure: 414.7871674924572 in H2O
- Maximum Diameter (Fan or Blower Wheel): 12.25 to 66 inch
- Applications / Use: Air Handling Units / HVAC, Exhaust Ventilation
-
Supplier: CANNON Instrument Company
Description: For Dilute Solution Viscosity of Polymers in Aggressive/Corrosive Solvents miniPV®-H is a fully automated, single sample, benchtop viscometer for testing polymer dilute solutions in aggressive solvents and corrosive acids. The Ubbelohde-style tube covers a 100-fold viscosity range between 0.3 cSt
- Kinematic Viscosity Range: 0.3 to 5,000 cSt
- Accuracy: 0.01 ±% Full Scale
- Display & Special Features: Computer Interface / Networkable, Laboratory / Benchtop (Batch)
- Features: Specialty / Other
-
Supplier: SKS Science Products
Description: The Azlon® break resistant transparent acrylic burets are screen printed in black to Class B accuracy. They are suitable for use in education, research or industrial laboratories, particularly when labware breakage is a concern. This series of burets is unaffected by most dilute aqueous solutions
- Features: Other
-
Supplier: Alconox, Inc.
Description: Nonionic, low foaming cleaner for use in labware washers, parts washers, power-spray systems, manual and ultrasonic cleaning. Corrosion inhibited formula recommended for glassware, metals, plastic, ceramic, porcelain, rubber and fiberglass. Free rinsing for reliable results and no interfering
- Concentration (As Used, by Volume): 0.5 %
- Type: Alkaline Cleaner (11 to 12.5 pH), Cleaner / Cleaning Agent, Degreaser, Detergent / Surfactant, Surface Treatment
- Features: Biodegradable, Contains Phosphate, Foam Free / Low Foaming
- Industry Applications: Biotech (Pharmaceutical / Medical), Critical Cleaning / Cleanroom (Residue Free), Laboratory / Labware
-
Description: Diluent buffer/blocker for use in Poly-HRP enhanced enzymatic labelling of antibodies and antigens Background: Conjugate Diluent/Blockers prolong the shelf-life of conjugated proteins and enhance their utility in laboratory applications. Conjugate diluents can be used to reconstitute
-
Supplier: Alconox, Inc.
Description: Concentrated, anionic detergent or manual and ultrasonic cleaning. Free rinsing to give you reliable results without interfering residues. Ideal for cleaning contaminants from glassware, metals, plastics, ceramic, porcelain, rubber and fiberglass. Excellent replacement for corrosive acids and
- Concentration (As Used, by Volume): 1 %
- Features: Biodegradable, Contains Phosphate, VOC Compliant
- Industry Applications: Biotech (Pharmaceutical / Medical), Critical Cleaning / Cleanroom (Residue Free), Laboratory / Labware
- Type: Cleaner / Cleaning Agent, Degreaser, Detergent / Surfactant, Mild Alkaline Cleaner / Agent (8.5 to 11 pH), Surface Treatment
-
Supplier: GFS Chemicals, Inc.
Description: ITEM#:A1539 Ca10(OH)2(PO4)6 CAS#:1306-06-5 F.W.:1004.62 NFPA#:0-0-0 Specific Gravity: 0.000 DOT:NR Descriptions: Hydroxyapatite Specification TEST 1. Insoluble in dilute HCl 0.07% 2. Chloride 0.05% 3. Nitrogen compounds (as N) 0.05% 4. Sulfate 0.3% 5. Heavy metals (as Pb) 0.002% 6. Iron 0.03%
- Function: Reagent
-
Supplier: Alconox, Inc.
Description: Nonionic, detergent for labware washers, PC board washers, power-spray systems, ultrasonic and manual cleaning. Removes oils, resins rosins, and fluxes from PC circuit boards, electronic parts, phosphate sensitive labware and nuclear contaminated equipment with no interfering conductive residues.
- Concentration (As Used, by Volume): 3 %
- Type: Alkaline Cleaner (11 to 12.5 pH), Aqueous / Water-based, Cleaner / Cleaning Agent, Detergent / Surfactant, Surface Treatment
- Features: Biodegradable, Foam Free / Low Foaming
- Industry Applications: Critical Cleaning / Cleanroom (Residue Free), Electrical / Electronics, Laboratory / Labware
-
Supplier: GFS Chemicals, Inc.
Description: ITEM#:696 MoO3 CAS#:1313-27-5 F.W.:143.94 NFPA#:2-0-0 Specific Gravity: 0.000 DOT:NR Descriptions: Specification TEST 1. Assay 99.5% min 2. Insoluble in dilute NH4OH 0.01% 3. Chloride 0.002% 4. Nitrate - Pass Test 5. Arsenate, phosphate, and silicate 0.001% 6. Phosphate 0.0005% 7. Sulfate 0.02% 8.
- Function: Reagent
-
Supplier: GF Piping Systems
Description: waste mixtures of acids, bases and solvents present in laboratory, industrial or food and beverage processing DWV applications.
- Maximum Pressure: 50 psi
- Temperature Range: 32 to 212 F
- Diameter: 1 1/2", 10", 12", 14", 16", 18", 2 1/2", 2", 3 1/2", 3", 4", 5", 6", 8"
- Material: Polypropylene (PP)
Find Suppliers by Category Top
Featured Products Top
-
Semi-Automated Liquid Handler, Diluter, & Dispenser Dilute • Dispense • Pipette • Aliquot • Titrate • Serial Dispense With unmatched versatility (read more)
Browse Laboratory Dispensers Datasheets for Hamilton Company -
utilizing a graphical user interface designed to quickly and easily dilute and dispense liquids. Every laboratory has tasks that are too small to automate and too large to reliably accomplish by hand. The Microlab 600 is a semi-automated liquid handler designed specifically for these "in-between" applications. The Microlab 600 increases throughput and consistency while reducing cost and wasted reagent. (read more)
Browse Pipettes and Tips Datasheets for Hamilton Company -
Diluters and Dispensers Laboratory & Portable Sensors Process Sensors (read more)
Browse Syringe Pumps Datasheets for Hamilton Company -
Accessories) Diluters and Dispensers (read more)
Browse Valve Positioners Datasheets for Hamilton Company -
. Gasoline and oils harden standard PVC over periods of intermittent use, but Clearflo Fuel & Oil is specially formulated to prevent hardening. Clearflo is generally unaffected by most oxidizing and reducing agents. Diluted acids and alkalies have little effect, though if highly concentrated they tend to (read more)
Browse Industrial Hose Datasheets for NewAge Performance Products | NAPP -
The MICROLAB 600 from Hamilton is a highly precise syringe pump with a graphical user interface designed to quickly and easily dispense and dilute liquids. The inert fluid path minimizes sample carry over and (read more)
Browse Diluters Datasheets for Hamilton Company -
good resistance to dilute mineral and organic acids, but in cases where Nylotube is being used in critical applications or aggressive environments, in-plant tests are always recommended. Nylotube is manufactured from heat-and light-stabilized materials. Nylon brittleness is usually caused by (read more)
Browse Tubing Datasheets for NewAge Performance Products | NAPP -
research specifications, the exceptional accuracy makes them the preferred choice for laboratories and research settings requiring reliable and repeatable gas control. For example, Environics Biological Atmosphere (read more)
Browse Mixing and Blending Controllers Datasheets for Environics, Inc. -
calibrated, while also considering measurement uncertainty, can validate their results and verify their quality. For laboratories, calibration can be used to enhance the lifespans of their apparatus. This is because it can help to uncover any issues with the instruments and ensure fewer replacements are (read more)
Browse Calibration Instruments Datasheets for Environics, Inc. -
to precisely dilute breathing air with nitrogen, they deliver repeatable physiological stress and avoid decompression risk. Although each system relies on the same normobaric hypoxia principles, they were developed to serve different training priorities. The ROBD2 established a stable, standardized (read more)
Browse Technical Training Equipment Datasheets for Environics, Inc.
Conduct Research Top
-
A Microfluidic System for Biological Particle Enrichment Using Contactless Dielectrophoresis
. Bioelectromechanical Systems Laboratory, Institute for Critical Technology and Applied. Science (ICTAS), Virginia Polytechnic Institute and State University, Blacksburg, VA 3. Bradley Department of Electrical and Computer Engineering, Virginia Polytechnic. Institute and State University, Blacksburg, VA 4
More Information Top
-
The body ion loss biomarker. 1. Interactions between trace metals and low pH in reconstituted coal mine‐polluted water
Net sodium loss rates of brook charr in the laboratory diluter system in severe RCMW containing all metals were signifi- cantly greater than net changes measured in the field after 1 h of exposure.
-
Index
Laboratory diluter , 381 Largemouth bass, 381, 383 Lemna minor, 122, 259-265 Lepomis macrochirus, 107, 196, 199, 246, 250, 381, 383 Linear alkylbenzene sulfonate (LAS), 120-125, 127-135 .
-
Development of Water Quality Criteria for Ammonia and Total Residual Chlorine for the Protection of Aquatic Life in Two Johnson County, Kansas, Streams
KEY WORDS: water quality criteria, ammonia, total residual chlorine, bioassays, orangethroat darter, red shiner, bluegill sunfish, largemouth bass, channel catfish, crayfish, riffle beetle, 96-h median lethal concentration (LC50), acute toxicity, labora- tory diluter , field study, application factors, aquatic life, drift, benthos …
-
An Approach to Laboratory Data Management: The Applications Generating Programmable Data Base
CNFRL receives samples either from internal groups (for example, laboratory diluter exposure studies), from actual field collections, or from other sources (for example, round-robin samples from other laboratories).
-
Composition of Semi-volatile Particles from Diesel Exhaust
Thus the laboratory diluter represents very well the real-atmospheric dilution process.
-
Road Transportable Analytical Laboratory (RTAL) system: Volume I. Final report
… Automated Liquid-Liquid Extractor Organic Chemical Analysis Laboratory Sample Analysis Room ICP Spectrometer in Aquatic Biomonitoring Chemical Analysis Laboratory Ventilatory Monitoring for Real-Time Acute Toxicity Measurement Aquatic Biomonitoring Laboratory Analytical/Operational Control Room Aquatic Biomonitoring Laboratory Main Diluter Room Operations Control Center …
-
Lithium Chloride: A Flow-Through Embryo-Larval Toxicity Test with the Fathead Minnow, Pimephales promelas Rafinesque
Diluter and laboratory lighting provided a 16h light/8 h dark transitional photoperiod during .
-
Serological Detection of Equid Herpesvirus1 Infections of the Respiratory Tract
A multiple diluter (Flow Laboratories , Scotland) was then ehpldyed to produce doubling dilutions of the serum through 7 wells; the last well in each row was used as a cell control.
-
In vitro anti-plasmodial and in vivo anti-malarial activity of some plants traditionally used for the treatment of malaria by the Meru community in Kenya
Aliquots of the test solutions (25 ll) were added in duplicate to the first wells, and a Titertek motorized hand diluter (Flow laboratories , Uxbridge, UK) was used to make serial twofold dilutions of each sample over a 64-fold concentration range.
-
Antimalarial activity of some plants traditionally used in Meru district of Kenya
Aliquots (25 µL) of the test solutions were added, in triplicate, to the first wells, and a Titertek motorized hand diluter (Flow Laborato- ries , Uxbridge, UK) was used to make serial 2-fold .
Indicates content that may require registration and/or purchase.