Supplier: Fischer Technology, Inc.
Description: SIGMASCOPE SMP350 is a compact handheld device for determining the electrical conductivity of non-ferrous metals such as aluminum or copper. The measured conductivity further enables you to draw conclusions about the hardness and strength of heat-treated materials. Evidence of
- Form Factor: Portable
- Measuring Range: 5.00E6 to 6.50E8 mS/cm
-
Supplier: HORIBA Instruments, Inc.
Description: Compact conductivity meter for measurement of low concentration which have glass carbon sensor. A glass carbon sensor is not contaminated by metal elution and is chemically resistant. Wide range compatibility: 0 - 9999 µS/cm Chemical resistant carbon sensor Compact size
- Conductivity / Dissolved Solids Range: 0.0 to 9999 µS/cm
- Display Type: Digital Display
- Measures Conductivity / Dissolved Solids: Yes
- Mounting / Environment: In-Situ / Field
-
Supplier: Centurion NDT
Description: The FM-140XL meter is useful for sorting a wide variety of non-ferrous metals and alloys, as well as for measuring changes in physical properties reflecting conductivity. Such changes include hardening, annealing, variations in alloy, heat treating corrosion and /or aging. The
- Measures Conductivity / Dissolved Solids: Yes
-
-
Supplier: Madison Company
Description: The M3850 is a small, low-cost stainless steel-polypropylene conductivity sensor probe designed for conductive liquids or water applications. When installed into a metal tank the probe or probes act as single point level conductors between each probe tip and the surrounding tank
- Display Type: None
- Extreme Environment: Yes
- Measures Conductivity / Dissolved Solids: Yes
- Mounting / Environment: In-Situ / Field
-
Supplier: PCE Instruments / PCE Americas Inc.
Description: -destructive conductivity tester for metals. This non-destructive testing (NDT) device uses eddy current to determine the electrical conductivity of non-ferrous metals such as aluminum and copper. Featuring an operating frequency of 60 kHz, the conductivity
- Battery Powered: Yes
- Display Type: Digital Display
- Mounting / Environment: Hand Held, Portable
- Temperature Compensation: Yes
-
Supplier: HORIBA Instruments, Inc.
Description: The HE-960R-GC(W) is resistivity meter to use glass carbon for its sensor. A glass carbon sensor is not contaminated by metal elution and is chemically resistant to such wet cleaning solutions as hydrofluoric acid and hydrogen peroxide. This is especially effective for resistivity
- Display Type: Digital Display
- Measures Resistivity: Yes
- Mounting / Environment: In-Situ / Field
- Resistivity Range: 0.0 to 100000 kohm-cm
-
Supplier: FineTek
Description: The very FIRST EPD Electromagnetic Flow Meter to be certified by OIML in Asia. EPD30 offers the industry’s widest range of liners, electrodes and sizes to meet the needs of even the most demanding process applications in sectors as diverse as chemical, power, oil & gas and metals
- Velocity Flow Rate: 0.3281 to 32.81 ft/sec
- Electrical Output: Analog Current
- Features: Audible or Visual Alarms
- Interface Options: Serial / Digital
-
Supplier: Sierra Instruments, Inc.
Description: of fluid conductivity to allow a wider applicability compared to magnetic meters. Common applications include: Cooling and heating fluid measurements Water and wastewater measurements Leak detection in piping systems Monitoring and
- Velocity Flow Rate: 0.3000 to 40 ft/sec
- Electrical Output: Analog Current
- End Fittings: Clamp
- Features: Recorder / Totalizer Functions
-
Supplier: PCE Instruments / PCE Americas Inc.
Description: -destructive material tester for metals. This non-destructive testing (NDT) device uses eddy current to determine the electrical conductivity of non-ferrous metals such as aluminum and copper. Featuring an operating frequency of 60 kHz, the conductivity meter has a
- Accuracy: 0.5000 to 1 ±% Full Scale
- Form Factor: Portable
- Measuring Range: 3.00E6 to 6.50E8 mS/cm
-
Supplier: Fischer Technology, Inc.
Description: SIGMASCOPE SMP350 is a compact handheld device for determining the electrical conductivity of non-ferrous metals such as aluminum or copper. The measured conductivity further enables you to draw conclusions about the hardness and strength of heat-treated materials. Evidence of
- Battery Powered: Yes
- Conductivity / Dissolved Solids Range: 5.00E9 to 6.50E11 µS/cm
- Conductivity Accuracy: 0.5000 ±% Full Scale
- Display Type: Digital Display
-
Description: provides extraordinary flexibility; the same controller can be used with almost any type of sensor needed; conductivity (contacting and electrodeless), amplified pH/ORP, or disinfection Two pH/ORP models available for use with non-amplified electrodes with or without a BNC connector
- Control Signal Output: Current Loop, Switch / Relay Output, Pulse / Frequency
- Control Technique: Limit / Set Point Control, PID Control
- Controller Inputs: Serial / Digital Input
- Form Factor: DIN Rail
-
Supplier: HORIBA Instruments, Inc.
Description: The CM-200A/210A hydrofluoric acid monitors have been developed specifically to meet the stringent demands of semiconductor manufacturing. The CM-200A/210A provides a real time read-out of hydrofluoric acid concentration by measuring the electric conductivity of the sample solution. These
- Conductivity / Dissolved Solids Range: 0.0 to 1.00E6 µS/cm
- Display Type: Digital Display
- Measures Conductivity / Dissolved Solids: Yes
- Mounting / Environment: Hand Held, Portable
-
Supplier: HORIBA Instruments, Inc.
Description: solutions (H2SO4/H2O2/H2O) used to remove metal ions and organic substances. Feedback control based on the monitor output is used to keep the concentrations of the SPM solutions within the allowable ranges and to eliminate unnecessary replacement of chemicals. A short measuring cycle allows
- Display Type: Digital Display
- Electrical Output: Analog Current Output, Switch / Alarm Relay Output
- Measures Conductivity / Dissolved Solids: Yes
- Mounting / Environment: In-Situ / Field
-
Supplier: Fischer Technology, Inc.
Description: With its GOLDSCOPE series, Fischer offers a tailored solution for the non-destructive testing of gold and precious metals. The hardware and software of these robust X-ray fluorescence instruments is adapted to the unique requirements of the jewelry and gold sector. Focusing on the most
- Form Factor: Bench / Rack
-
Supplier: ASTM International
Description: 1.1 This test method covers a procedure for determining the electrical conductivity of nonmagnetic metals using the electromagnetic (eddy current) method. The procedure has been written primarily for use with commercially available direct reading electrical conductivity
-
Supplier: ASTM International
Description: 1.1 This test method covers a procedure for determining the electrical conductivity of nonmagnetic materials, typically nonmagnetic metals, using the electromagnetic (eddy current) method. The procedure has been written primarily for use with commercially available direct reading
-
Supplier: Micromeritics
Description: information about the physical properties of your catalyst, catalyst support, or other materials. It can determine catalytic properties such as percent of metal dispersion, active metal surface area, acid strength, surface acidity, distribution of strength of active sites, BET surface
- Display & Special Features: Analog Meter, Laboratory / Batch
- Property Analyzed: Surface Area - Total
- Test Media / Material: Chemicals, Metals, Other
-
Supplier: Cole-Parmer
Description: readings when appropriate • Rugged vinyl clad metal enclosure withstands harsh environments The Model 276 vacuum gauge incorporates two different sensors: thermocouple and piezoresistive. The thermocouple sensor reading is automatically taken by the meter below 5 Torr, and the
-
Supplier: Micromeritics
Description: the sample or released from the sample surface is monitored by a Thermal Conductivity Detector (TCD). Data obtained by the instruments can be used to calculate key parameters for catalyst characterization: metal dispersion, active surface area, BET surface area, average crystallite
- Display & Special Features: Digital Readout, Laboratory / Batch
- Property Analyzed: Surface Area - Specific, Surface Area - Total
- Specific Surface Area Range: Over 0.0200
- Test Media / Material: Chemicals, Metals, Other
-
Supplier: Visual Sound, Inc.
Description: below the top plate to improve gap flux symmetry and increase thermal conductivity from the voice coil to the pole piece. In addition to the benefits of JBL's Symmetrical Field GeometryTM, the 2242H also incorporates a copper shorting ring that is imbedded in the pole piece at the precise
-
Supplier: 3X Ceramic Parts Company Limited
Description: metal plunger is much lower than that of the ceramic plunger. The ceramic plunger has high temperature resistance, wear resistance, corrosion resistance and impact resistance, which guarantees a longer service life. It is widely used in various liquid pumps, metering pumps, high
- Applications: Dielectric / Electrical Insulation
- Density: 2.4 to 3.95 g/cc
- Dielectric Strength: 7.87E6 to 8.86E6 V/m
- Material Type: Alumina / Aluminum Oxide, Zirconia, Specialty Ceramic
-
Supplier: Plansee SE
Description: CIGS solar cells. But how to produce molybdenum thin films? In the magnetron sputtering method tiny metal particles are vaporized from the sputtering targets and are then deposited as a thin film on the glass substrate. In this fast, economical coating process, all the
- Type: Sputtering Target
-
Supplier: 3X Ceramic Parts Company Limited
Description: Machinable Glass Ceramic Parts Machining Instruction: Machinable ceramics is a new kind of ceramic material, the material the use of metal processing tools and equipment can usually work out precision tolerance of the products, here is a brief introduction of its processing technology and
- Applications: Dielectric / Electrical Insulation
- Compressive / Crushing Strength: 73679 psi
- Density: 2.48 g/cc
- MOR / Flexural Strength: 15664 psi
-
Supplier: FX PCB Co., Ltd.
Description: of various electrical and electronic devices. Therefore, you will see metal PCBs, Ceramic PCBs, and even transparent glass PCBs. Believe it or not, transparent glass PCB technology has brought revolutionary changes in the printed circuit board industry. The transparent glass PCB is used in
- Materials of Construction: Specialty / Other
- Thickness: 0.0197 to 0.1575 inches
Find Suppliers by Category Top
Featured Products Top
-
PCE-COM 20 is a portable handheld non-destructive conductivity tester for metals. This non-destructive testing (NDT) device uses eddy current to determine the electrical conductivity of non-ferrous metals such as aluminum and copper (read more)
Browse Conductivity and Resistivity Meters Datasheets for PCE Instruments / PCE Americas Inc. -
-power LEDs, and advanced heat dissipation components. Features • High thermal conductivity (170~230W/m.K), up to 9.5 times than alumina; • Thermal expansion coefficient close to silicon wafer, achieve high reliability of Silicon chip and thermal (read more)
Browse Ceramic Sheets and Boards Datasheets for Xiamen Innovacera Advanced Materials Co., Ltd. -
. Thermal conductivity ranges between 120 and 200 watts per meter-kelvin, allowing for excellent heat transfer in high-temperature environments. The tube operates stably at temperatures up to 1600 degrees Celsius (2912 degrees (read more)
Browse Industrial Ceramic Materials Datasheets for Shenzhen Great Precision Ceramic CO., LTD. -
Dexmet® Corporation, a part of PPG’s engineered materials division
MicroGrid® Materials for Wind Applications
on desired weight, conductivity, or open area to meet exact application requirements. Dexmet MicroGrid® Advantages Lightning protection materials are available in either copper or aluminum in a wide range of (read more)
Browse Lightning Protection Systems Datasheets for Dexmet® Corporation, a part of PPG’s engineered materials division -
reliability, and reducing their vendor/supplier count. In the latest concept vehicles, multi-alloy bus bars—created as a single unit and as long as one meter – are being custom fabricated by welding aluminum and copper. This answers the need for increasing capacity, conductivity and (read more)
Browse Busbars and Busways Datasheets for Isabellenhutte USA -
. Reduced Response Times and Immersion Depth Utilizing a special, thermally conductive metallization construction encased in thin wall tubing, IST’s RealProbeTemp provides an unequaled probe assembly with a fast response time and reduced (read more)
Browse Resistive Temperature Devices (RTD) Elements Datasheets for Innovative Sensor Technology IST USA Division -
high hardness, wear resistance, chemical stability and dimensional reliability. Great Ceramic supplies custom ZTA components for applications where metal, polymer or monolithic ceramic parts may be limited by abrasion, corrosion, cyclic loading or high-temperature service. Typical (read more)
Browse Zirconium Oxide and Zirconia Ceramics Datasheets for Shenzhen Great Precision Ceramic CO., LTD.
Conduct Research Top
-
A Microfluidic System for Biological Particle Enrichment Using Contactless Dielectrophoresis
of the buffer was. 130 mS/cm and was measured with a Mettler-Toledo SevenGo. pro conductivity meter (Mettler-Toledo, Inc., Columbus,. OH) to ensure that its conductivity was 130 ms/cm. These cells were observed to be spherical, with a diameter. of w13 mm when in suspension. Carboxylate-modified polystyrene
More Information Top
-
Test trainer physics
Compression 278 multiple beam interferences on the grid 344 on optical coatings 346 measuring regions by electrical meters 201 metal , conductivity 366 Metallic bond 361 MetaStable intermediate state 464 Michelson-Morley experiment 398 Miller'sche indices 350 Millikan attempt 168 minimum of the…
-
Test trainer physics
Compression 276 multiple beam interferences on the grid 342 on optical coatings 344 measuring regions by electrical meters 199 metal , conductivity 364 Metallic bond 359 MetaStable intermediate state 462 Michelson-Morley experiment 396 Miller'sche indices 348 Millikan attempt 166 minimum of the…
-
AIAA Journal > Optimal Functionally Graded Metallic Foam Thermal Insulation
For titanium foam used in our study, the temperature-dependent metal conductivity (watts per me- ter per degree Kelvin) is given by12 .
-
A positioning and data logging system for surface geophysical surveys
While the magnetometer responds only to the total mass of ferrous metal , the terrain conductivity meter responds .
-
Model-based characterization of homogeneous metal plates by four-point alternating current potential drop measurements
This conductivity measurement method yields more accurate results for low-conductivity metals than measurements using standard conductivity meters , such as a MIZ-21A eddy current instrument.
-
Test plan for dig-face characterization performance testing
In the prototype system, magnetometers will be used to detect ferrous metals , and an electromagnetic conductivity meter will be used to detect all types of conductive metals.
-
Electronic system packaging: the search for manufacturing the optimum in a sea of constraints
…Y is the signal attenuation (decibels per meter) possible with a solid plane, f is the continuous wave (or pulse design) frequency (hertz), p is the magnetic permeabil- ity (henrys per meter), and U is the metal plane conductivity (mhos per meter ).
-
Oxygen diffusion through a developing biofilm of pseudomonas fluorescens
The second terminal of the conductivity meter was connected to the metal base.
-
Guidelines for the Application of Geophysics to Onshore E and P Environmental Studies
Also, metal detectors, a form of conductivity meter , can also be useful 27.
-
SOAR: An extensible suite of codes for weld analysis and optimal weld schedules
where the following are input by the user via the GUZ-driven application, T = contour temperature of interest (deg C) To = base metal temperature k, =thermal conductivity of metal (Joules/( meter -sec-deg C)) t .