Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: HORIBA Instruments, Inc.
Description: Compact conductivity meter for measurement of low concentration which have glass carbon sensor. A glass carbon sensor is not contaminated by metal elution and is chemically resistant. Wide range compatibility: 0 - 9999 μS/cm Chemical resistant carbon sensor Compact size
- Conductivity / Dissolved Solids Range: 0 to 9,999 µS/cm
- Display Type: Digital Display
- User Controls: Digital Front Panel
- Form Factor: In-Situ / Field
-
Supplier: Centurion NDT
Description: The FM-140XL meter is useful for sorting a wide variety of non-ferrous metals and alloys, as well as for measuring changes in physical properties reflecting conductivity. Such changes include hardening, annealing, variations in alloy, heat treating corrosion and /or aging. The
- Water Quality Parameters: Measures Conductivity / Dissolved Solids
-
Supplier: PCE Instruments / PCE Americas Inc.
Description: for metals. This non-destructive testing (NDT) device uses eddy current to determine the electrical conductivity of non-ferrous metals such as aluminum and copper. Featuring an operating frequency of 60 kHz, the conductivity meter has a large measuring range of
- Features and Functionality: Battery Powered
- User Controls: Computer Interface, Digital Front Panel
- Display Type: Digital Display
- Form Factor: Hand Held, Portable
-
-
Supplier: Madison Company
Description: The M3850 is a small, low-cost stainless steel-polypropylene conductivity sensor probe designed for conductive liquids or water applications. When installed into a metal tank the probe or probes act as single point level conductors between each probe tip and the surrounding tank.
- Features and Functionality: Extreme Environment
- Form Factor: In-Situ / Field
- Water Quality Parameters: Measures Conductivity / Dissolved Solids
- User Controls: None
-
Supplier: Fischer Technology, Inc.
Description: SIGMASCOPE SMP350 is a compact handheld device for determining the electrical conductivity of non-ferrous metals such as aluminum or copper. The measured conductivity further enables you to draw conclusions about the hardness and strength of heat-treated materials. Evidence of
- Measuring Range: 5,000,000 to 650,000,000 mS/cm
- Features: Conductivity / Resistivity Instrument, Material Condition Tester
- Instrument Technology: Eddy Current / Electromagnetic
- Form Factor: Portable / Hand Held / Mobile
-
Supplier: FineTek
Description: documentation. EPD Electromagnetic Flow Meter, Water Flow Meter (OIML) The working principle of the electromagnetic flow meter is based on the Faraday law of electromagnetic induction. When the conducting liquid flows in the orthogonal direction of the magnetic line direction,
- Velocity Flow Rate: 0.328083989501312 to 32.8083989501312 ft/sec
- Velocity Flow Rate Range: 0.328083989501312 to 32.8083989501312 ft/sec
- Electrical Output: Analog Current
- Features: Audible or Visual Alarms
-
Description: be used with almost any type of sensor needed; conductivity (contacting and electrodeless), amplified pH/ORP, or disinfection Two pH/ORP models available for use with non-amplified electrodes with or without a BNC connector Multiple language support allows simple setup no matter where your
- Number of Inputs: 1 inputs
- Number of Control Outputs: 4 outputs
- Control Signal: Current Loop, Pulse / Frequency, Switch / Relay Output
- Form Factor: DIN Rail
-
Supplier: Sierra Instruments, Inc.
Description: 210 portable, hand-held flow meter measures the time it takes an ultrasonic signal to travel a known distance with the flow stream and another signal travelling against the flow stream, determining the velocity of the fluid being measured. The 210 measurement is independent of fluid
- Pipe Diameter: 2 to 236 inch
- Media Temperature Range: -40 to 176 F
- Velocity Flow Rate: 0.3 to 40 ft/sec
- Operating Temperature: 14 to 122 F
-
Supplier: HORIBA Instruments, Inc.
Description: The HE-960R-GC(W) is resistivity meter to use glass carbon for its sensor. A glass carbon sensor is not contaminated by metal elution and is chemically resistant to such wet cleaning solutions as hydrofluoric acid and hydrogen peroxide. This is especially effective for resistivity
- Resistivity Range: 0 to 100,000 kohm-cm
- Display Type: Digital Display
- User Controls: Digital Front Panel
- Form Factor: In-Situ / Field
-
Supplier: ASTM International
Description: 1.1 This test method covers a procedure for determining the electrical conductivity of nonmagnetic metals using the electromagnetic (eddy current) method. The procedure has been written primarily for use with commercially available direct reading electrical conductivity
-
Supplier: PCE Instruments / PCE Americas Inc.
Description: metals. This non-destructive testing (NDT) device uses eddy current to determine the electrical conductivity of non-ferrous metals such as aluminum and copper. Featuring an operating frequency of 60 kHz, the conductivity meter has a large measuring range of 0.51
- Measuring Range: 3,000,000 to 650,000,000 mS/cm
- Accuracy: 0.5 to 1 ±% Full Scale
- Features: Conductivity / Resistivity Instrument
- Instrument Technology: Eddy Current / Electromagnetic
-
Supplier: Fischer Technology, Inc.
Description: SIGMASCOPE SMP350 is a compact handheld device for determining the electrical conductivity of non-ferrous metals such as aluminum or copper. The measured conductivity further enables you to draw conclusions about the hardness and strength of heat-treated materials. Evidence of
- Conductivity / Dissolved Solids Range: 5,000,000,000 to 650,000,000,000 µS/cm
- Conductivity Accuracy: 0.5 ±% Full Scale
- Operating Temperature: 41 to 122 F
- Features and Functionality: Battery Powered, Temperature Compensation
-
Supplier: HORIBA Instruments, Inc.
Description: latest memory production lines. Sensor designed for stable measurement The CM-200A/210A feature sensors molded entirely of PFA resin. This eliminated the danger of the solution affecting metal parts, or of metal ions or other impurities leaking into the sample solution. Upper/lower
- Conductivity / Dissolved Solids Range: 0 to 1,000,000 µS/cm
- Process Media Temperature: 50 to 104 F
- Operating Temperature: 41 to 95 F
- Display Type: Digital Display
-
Supplier: HORIBA Instruments, Inc.
Description: (H2SO4/H2O2/H2O) used to remove metal ions and organic substances. Feedback control based on the monitor output is used to keep the concentrations of the SPM solutions within the allowable ranges and to eliminate unnecessary replacement of chemicals. A short measuring cycle allows the
- Process Media Temperature: 68 to 140 F
- Operating Temperature: 68 to 77 F
- Electrical Output: Analog Current Output, Switch / Alarm Relay Output
- Display Type: Digital Display
-
Supplier: Fischer Technology, Inc.
Description: detectors SDD devices have silicon drift detectors for higher resolution of elements that are similar to each other FISCHER WinFTM® software with predefined measurement tasks in analyzing precious metals Applications Non-destructive analysis of jewelry, coins and precious metals in
- Form Factor: Bench / Rack / Cabinet
- Features: Conductivity / Resistivity Instrument, Material Condition Tester
- Instrument Technology: Eddy Current / Electromagnetic, Radiographic / X-ray
-
Supplier: Cole-Parmer
Description: Rugged vinyl clad metal enclosure withstands harsh environments The Model 276 vacuum gauge incorporates two different sensors: thermocouple and piezoresistive. The thermocouple sensor reading is automatically taken by the meter below 5 Torr, and the piezoresistive sensor above 5 Torr.
-
Supplier: Micromeritics
Description: about the physical properties of your catalyst, catalyst support, or other materials. It can determine catalytic properties such as percent of metal dispersion, active metal surface area, acid strength, surface acidity, distribution of strength of active sites, BET surface area, and
- Properties Analyzed: Adsorption / Desorption (Chemisorption/ Physisorption), Surface Area - Total
- Display & Special Features: Analog Meter
- Test Media: Chemicals, Metals
- Mounting / Loading Options: Laboratory / Batch
-
Supplier: Micromeritics
Description: released from the sample surface is monitored by a Thermal Conductivity Detector (TCD). Data obtained by the instruments can be used to calculate key parameters for catalyst characterization: metal dispersion, active surface area, BET surface area, average crystallite size, surface
- Specific Surface Area Range: 0.02
- Total Surface Area Range: 0.02 to 199.9 m²
- Properties Analyzed: Adsorption / Desorption (Chemisorption/ Physisorption), Contamination (Shives, Dirt, Bacteria), Surface Area - Specific, Surface Area - Total
- Test Media: Chemicals, Metals
-
Supplier: 3X Ceramic Parts Company Limited
Description: Ceramic Plunger Description : Our ceramic plungers are made of high quality imported raw materials, cold isostatic pressing forming way , and assembled with stainless steel metal parts after high temperature sintering. As one of the main components of the plunger pump, the ceramic plunger is
- Density: 2.3999984852950598 to 3.9499975070481197 g/cc
- Dielectric Strength: 7,874,015.74803148 to 8,858,267.716535416 V/m
- Features: Alumina / Aluminum Oxide, Specialty Ceramic
- Applications: Dielectric / Electrical Insulation
-
Supplier: Visual Sound, Inc.
Description: plate to improve gap flux symmetry and increase thermal conductivity from the voice coil to the pole piece. In addition to the benefits of JBL's Symmetrical Field GeometryTM, the 2242H also incorporates a copper shorting ring that is imbedded in the pole piece at the precise center of the gap
-
Supplier: JiuJiang Ingiant Technology Co., Ltd.
Description: reliability. · Both the rotor and stator are equipped with aviation plugs · Easy to maintain and replace · IP51, IP65, IP68 optional · Using advanced precious metal cluster brush multi-point contact to ensure reliable contact under extremely low friction · Commonly used in high-end
- Number of Circuits: 47
- Operating Speed: 0 to 600 rpm
- Maximum Voltage: 0 to 240 volts
- Operating Temperature: -40 to 149 F
-
Supplier: Plansee SE
Description: cells. But how to produce molybdenum thin films? In the magnetron sputtering method tiny metal particles are vaporized from the sputtering targets and are then deposited as a thin film on the glass substrate. In this fast, economical coating process, all the materials must meet the highest
- Type: Sputtering Target
-
Supplier: 3X Ceramic Parts Company Limited
Description: pursuit of high efficiency . Thread Tapping: The tapping of machinable ceramics is somewhat different from the tapping of metal materials. The gaps between the holes and the holes to be tapped should be larger than those of the metal. When tapping, the sides of the buckles in the holes
- Density: 2.4799984348048953 g/cc
- Thermal Conductivity: 1.71 W/m-K
- MOR / Flexural Strength: 15,663.978650577275 psi
- Compressive / Crushing Strength: 73,678.71439345607 psi
-
Supplier: FX PCB Co., Ltd.
Description: like nothing else to meet the requirements of various electrical and electronic devices. Therefore, you will see metal PCBs, Ceramic PCBs, and even transparent glass PCBs. Believe it or not, transparent glass PCB technology has brought revolutionary changes in the printed circuit board
- Thickness: 0.01968503937007874 to 0.15748031496062992 inches
- Features: Specialty / Other
Find Suppliers by Category Top
Featured Products Top
-
PCE-COM 20 is a portable handheld non-destructive conductivity tester for metals. This non-destructive testing (NDT) device uses eddy current to determine the electrical conductivity of non-ferrous metals such as aluminum and copper (read more)
Browse Conductivity and Resistivity Meters Datasheets for PCE Instruments / PCE Americas Inc. -
-power LEDs, and advanced heat dissipation components. Features • High thermal conductivity (170~230W/m.K), up to 9.5 times than alumina; • Thermal expansion coefficient close to silicon wafer, achieve high reliability of Silicon chip and thermal (read more)
Browse Ceramic Sheets and Boards Datasheets for Xiamen Innovacera Advanced Materials Co., Ltd. -
. Thermal conductivity ranges between 120 and 200 watts per meter-kelvin, allowing for excellent heat transfer in high-temperature environments. The tube operates stably at temperatures up to 1600 degrees Celsius (2912 degrees (read more)
Browse Industrial Ceramic Materials Datasheets for Shenzhen Great Precision Ceramic CO., LTD. -
Dexmet® Corporation, a part of PPG’s engineered materials division
MicroGrid® Materials for Wind Applications
on desired weight, conductivity, or open area to meet exact application requirements. Dexmet MicroGrid® Advantages Lightning protection materials are available in either copper or aluminum in a wide range of (read more)
Browse Lightning Protection Systems Datasheets for Dexmet® Corporation, a part of PPG’s engineered materials division -
Silicon Nitride Ceramic Substrate INNOVACERA Silicon Nitride substrates, with a thermal conductivity rating of 90 Watts/meter Kelvin, at first (read more)
Browse Silicon Nitride and Silicon Nitride Ceramics Datasheets for Xiamen Innovacera Advanced Materials Co., Ltd. -
reliability, and reducing their vendor/supplier count. In the latest concept vehicles, multi-alloy bus bars—created as a single unit and as long as one meter – are being custom fabricated by welding aluminum and copper. This answers the need for increasing capacity, conductivity and (read more)
Browse Busbars and Busways Datasheets for Isabellenhutte USA -
. Reduced Response Times and Immersion Depth Utilizing a special, thermally conductive metallization construction encased in thin wall tubing, IST’s RealProbeTemp provides an unequaled probe assembly with a fast response time and reduced (read more)
Browse Resistive Temperature Devices (RTD) Elements Datasheets for Innovative Sensor Technology IST USA Division -
high hardness, wear resistance, chemical stability and dimensional reliability. Great Ceramic supplies custom ZTA components for applications where metal, polymer or monolithic ceramic parts may be limited by abrasion, corrosion, cyclic loading or high-temperature service. Typical (read more)
Browse Zirconium Oxide and Zirconia Ceramics Datasheets for Shenzhen Great Precision Ceramic CO., LTD.
Conduct Research Top
-
A Microfluidic System for Biological Particle Enrichment Using Contactless Dielectrophoresis
of the buffer was. 130 mS/cm and was measured with a Mettler-Toledo SevenGo. pro conductivity meter (Mettler-Toledo, Inc., Columbus,. OH) to ensure that its conductivity was 130 ms/cm. These cells were observed to be spherical, with a diameter. of w13 mm when in suspension. Carboxylate-modified polystyrene
More Information Top
-
Test trainer physics
Compression 278 multiple beam interferences on the grid 344 on optical coatings 346 measuring regions by electrical meters 201 metal , conductivity 366 Metallic bond 361 MetaStable intermediate state 464 Michelson-Morley experiment 398 Miller'sche indices 350 Millikan attempt 168 minimum of the…
-
Test trainer physics
Compression 276 multiple beam interferences on the grid 342 on optical coatings 344 measuring regions by electrical meters 199 metal , conductivity 364 Metallic bond 359 MetaStable intermediate state 462 Michelson-Morley experiment 396 Miller'sche indices 348 Millikan attempt 166 minimum of the…
-
AIAA Journal > Optimal Functionally Graded Metallic Foam Thermal Insulation
For titanium foam used in our study, the temperature-dependent metal conductivity (watts per me- ter per degree Kelvin) is given by12 .
-
A positioning and data logging system for surface geophysical surveys
While the magnetometer responds only to the total mass of ferrous metal , the terrain conductivity meter responds .
-
Model-based characterization of homogeneous metal plates by four-point alternating current potential drop measurements
This conductivity measurement method yields more accurate results for low-conductivity metals than measurements using standard conductivity meters , such as a MIZ-21A eddy current instrument.
-
Test plan for dig-face characterization performance testing
In the prototype system, magnetometers will be used to detect ferrous metals , and an electromagnetic conductivity meter will be used to detect all types of conductive metals.
-
Electronic system packaging: the search for manufacturing the optimum in a sea of constraints
…Y is the signal attenuation (decibels per meter) possible with a solid plane, f is the continuous wave (or pulse design) frequency (hertz), p is the magnetic permeabil- ity (henrys per meter), and U is the metal plane conductivity (mhos per meter ).
-
Oxygen diffusion through a developing biofilm of pseudomonas fluorescens
The second terminal of the conductivity meter was connected to the metal base.
-
Guidelines for the Application of Geophysics to Onshore E and P Environmental Studies
Also, metal detectors, a form of conductivity meter , can also be useful 27.
-
SOAR: An extensible suite of codes for weld analysis and optimal weld schedules
where the following are input by the user via the GUZ-driven application, T = contour temperature of interest (deg C) To = base metal temperature k, =thermal conductivity of metal (Joules/( meter -sec-deg C)) t .
Indicates content that may require registration and/or purchase.