-
Supplier: North Star Imaging, Inc.
Description: North Star Imaging offers nearly every type of industiral x-ray tube avaiable to meet your inspection needs. We offer: Nano-focus X-ray Tubes / Submicron X-ray Tubes Micro-focus X-ray Tubes Mini-focus
- X-ray Source: X-ray tube and Power Supply
-
Description: Thermo Scientific* MiniFocus Portable X-ray source 50kV side window is a constant potential, continuous duty portable X-ray source.The spot size is useful in radiographic and real-time applications that require good image quality.
- Voltage: 50 kilovolts
- X-ray Source: X-ray tube and Power Supply
-
Description: Thermo Scientific* PXS11-150-75, 75kV MiniFocus X-ray source displays 45 micron spot size with high resolution direct X-ray magnified images over the entire range of operation.Combines the X-ray tube, high voltage power supply and control circuitry in
- Voltage: 40 to 75 kilovolts
- Tube Current: 150 microamps
- Focal Spot Size: 45 µm
- X-ray Source: X-ray tube and Power Supply
-
-
Description: The PXS5-501SA is a constant potential, continuous duty portable x-ray source for use in field applications, or where a compact spot x-ray source is required. The 0.25mm spot size is useful in radiographic and real time applications that require good image quality. The
- X-ray Operating Voltage: 10 to 50 kilovolts
- Focal Spot Size: 100 µm
- Instrument Type: Flaw Detection
- Form Factor: Portable / Hand Held / Mobile
-
Supplier: Rigaku Corporation
Description: Specifically designed for rapid batch testing of low and ultra-low sulfur diesel (ULSD) and gasoline fuel samples, the compact benchtop Mini-Z Sulfur analyzer is designed for easy use by non-technical personnel. Whether at petroleum pipeline terminals, refineries, or testing laboratories, the
- Detection Limit: 0.26 ppm
- Operating Temperature: 59 to 82.4 F
- Operating Humidity: 0 to 75 %
- Optical System: Crystal
-
Supplier: Rigaku Corporation
Description: variations. Operating at 600 watts (X-ray tube), the MiniFlex 600 is twice as powerful as other benchtop models, enabling faster analysis and improved overall throughput. Running at 300 watts (X-ray tube), the new MiniFlex 300 does not require an external
- Angular Range: -3 to 145 degrees
- Features: Benchtop
- Diffracted Beam Optics: Collimators and Slits, K-Beta Absorption Filter, Monochromating Crystal
- Positioning System: Goniometer
-
Description: The Thermo Scientific Kevex PXS11-150-75 is a 75kV, 11.25W X-Ray Source for applications requiring high resolution. The compact package houses a side-window mini-focus sealed tube, high voltage power supply and control circuitry which besides controlling and monitoring
- X-ray Operating Voltage: 40 to 75 kilovolts
- Focal Spot Size: 45 µm
- Instrument Type: Flaw Detection
- Form Factor: Portable / Hand Held / Mobile
-
Supplier: Accuris
Description: Standard Test Method for Measurement of the Effective Focal Spot Size of Mini and Micro Focus X-ray Tubes
-
Supplier: Accuris
Description: Non-destructive testing \x97 Characteristics of focal spots in industrial X-ray systems \x97 Part 3: Measurement of the effective focal spot size of mini and micro focus X-ray tubes
-
Supplier: Accuris
Description: Method for Measurement of the Effective Focal Spot Size of Mini-Focus and Micro-Focus X-Ray Tubes Used for Industrial Radiography
-
Supplier: Accuris
Description: Non-destructive testing \x96 Characteristics of focal spots in industrial X-ray systems \x96 Part 3: Measurement of the effective focal spot size of mini and micro focus X-ray tubes (ISO/DIS 32543-3:2024)
-
Supplier: ASTM International
Description: focal spot size of mini and micro focus X-ray tubes. 1.3 This standard specifies a method for the measurement of effective focal spot dimensions from 5 up to 300 μm of X-ray systems up to and including 225 kV tube voltage, by means of radiographs of
-
Supplier: ASTM International
Description: the effective size (dimensions) of standard and mini focal spots of industrial x-ray tubes. This determination is based on the measurement of an image of a focal spot that has been radiographically recorded with a “pinhole” technique. 1.3 This standard specifies a method
-
Supplier: AENOR
Description: Non-destructive testing - Characteristics of focal spots in industrial X-ray systems - Part 3: Measurement of the effective focal spot size of mini and micro focus X-ray tubes (ISO 32543-3:2026)
-
Supplier: AENOR
Description: Non-destructive testing - Characteristics of focal spots in industrial X-ray systems for use in non-destructive testing - Part 5: Measurement of the effective focal spot size of mini and micro focus X-ray tubes
Find Suppliers by Category Top
Featured Products Top
-
50 degree total angle of adjustment so your nozzles can be in the best position for maximum effectiveness. The 1/8 MNPT Mini Swivel Fittings work with the M4x0.5 Atto Super Air Nozzle, the M5x0.5 Pico Super Air Nozzle, and the M6x0.75 Nano Super Air Nozzle. EXAIR’s mini swivel fittings (read more)
Browse Nozzles Datasheets for EXAIR -
today. Connect with Oriental Motor: Facebook, LinkedIn, X and YouTube (read more)
Browse Electric Rotary Actuators Datasheets for Oriental Motor USA -
cables assemblies. Shown is the 2620 Bantam Phone Plug to X100W Mini-Hook test connectors. The 2620 coaxial test cable assembly adapter features (read more)
Browse Datasheets for E-Z-HOOK, a division of Tektest, Inc. -
Facebook, LinkedIn, X and YouTube (read more)
Browse Stepper Motors (rotary) Datasheets for Oriental Motor USA -
1020 Male BNC Coaxial Test Cable RG58C/U to X100W Mini-Hooks. The 1020 coaxial test cable assembly adapter features a BNC Male coaxial test connector to an In-Line Y splicing block to a red X100W mini-hook (center) and a (read more)
Browse Cable Assemblies Datasheets for E-Z-HOOK, a division of Tektest, Inc. -
Guide to High Temperature Test Hook Connectors Both the X100W mini (read more)
Browse Electrical Connectors Datasheets for E-Z-HOOK, a division of Tektest, Inc. -
the external signal source with the controller, a custom cable was fabricated using: a 6-pin mini-DIN male connector for the controller side a BNC connector for the signal source side This configuration allowed the analog output of a function generator to be (read more)
Browse Datasheets for PI (Physik Instrumente) L.P.
More Information Top
-
Of the industry - new of the Montan university, personal messages, convention announcements
…to prevent manipulations, measuring protocol building simply and quickly-NEU, now possible to Mg- Al, Si- and P determination to achievable regions (LZX series) unites Innov-X of system ergonomic design with functional, safe mini - roentgen tube of technology integrated in a…
-
X-ray imaging with YSO scintillating crystal array
The X-ray energy test with Mini X - ray tube and Am241 source .
-
Laboratory tests of the Pulse Height Analysis system for
Wendelstein 7-X
In the PHA system a calibration port with mini X - ray tube from AMPTEK has been located between the main vacuum chamber and the detector .
-
X Ray Equipment - X Ray Equipment Manufacturers, Suppliers
Mini X - ray Tubes For High Frequency Dental X Ray Equipment , KL27-0.8-70, .
-
Analysis of the spectacular gold and silver from the Moche tomb ‘Señora de Cao’
For the measurements carried out in the Museum of Cao, the portable equipment was composed of a mini X - ray tube by AMPTEK (Bedford, MA, USA),[38] which is characterized by a Ag- anode and works at 40kV and 200 μA maximum…
-
Atoms, Molecules and Optical Physics 1
Top: Photo of a mini X - ray tube with side exit of the radiation.
-
Minimum detection time (MDT) for elemental EDXRF images
(1) PC: Control software and image processing, (2) processor pulse with multichannel amplifier (PX4), (3) platform with robotic arm, (4) SDD detector, (5) mini X - ray tube , (6) sample analysis.
-
In vivo EDXRF scanning analysis of human nail
EDXRF scan spectrometer, showing its various components: (1) DPP multiprocessor, (2) scan control, (3) robotic arm support table, (4) ro- botic arm, (5) X - Ray mini tube , (6) SDD Si(Li) detector, and (7) finger holder.
-
Multifunctional Yolk‐in‐Shell Nanoparticles for pH‐triggered Drug Release and Imaging
To measure radioluminescence, X-ray was gen- erated by a mini X - ray tube (Amptek Inc. MA, USA), the X-ray tube was operated with tube voltage of 40 kV and tube current of 99 µA.
-
Characteristics of a robust and portable large area X‐ray fluorescence imaging system
(1) Mini X - ray tube ; (2) Silicon Drift Detector; (3) Head Support; (4) Sample; (5) Robotic arm; (6) Stepper Motor Control; (7) Digital pulse pro- cessor, multichannel analyser and power supply.
Indicates content that may require registration and/or purchase.