Products/Services for NFPA Fire Hydrant Bollards
-
Bollards - (206 companies)...bike lanes, and fire lanes, or they can be used to restrict access to certain areas. Figure 8: Bollards. Source: Kenneth Allen/CC BY-SA 2.0 Security Anti-ram bollards can protect people, property, and infrastructure from vehicle-based attacks... -
Hydrants - (83 companies)Hydrants are valve devices that are used to dispense large volumes of liquid. Hydrants are valves made to deliver a large flow of water, hence its name "Hydrant " as it relates to water. Types of Hydrants. Fire Hydrants. The most common and visible... -
Fire Protection Services - (258 companies)...and nozzles. fire pump controllers. hydrants. non-water based chemical extinguishing systems. Some fire protection services install, monitor, and maintain pipe hangers, seismic sway-brace components for sprinkler systems, underground pipe and fittings...
-
Flammability and Fire Testing Services - (47 companies)...and 700 series of the National Fire Protection Agency (NFPA), as well combustibles standards issued by the American Society for Testing and Materials (ASTM) International, and the American National Standards Institute (ANSI). Lab-sized units can range... -
Fire Sprinkler Heads - (80 companies)...are covered by various National Fire Protection Association (NFPA) standards for a larger fire sprinkler system. Major standards include NFPA-13, NFPA-13D, and NFPA-13R. There are also a number of secondary standards for a fire sprinkler head... -
Fire Alarm Control Panels - (241 companies)...in the United States. National Building Code of Canada - Construction regulations in Canada. Approved Document B - Fire safety regulations for buildings in England, Wales. NFPA 72 - Regards all aspects of fire alarm performance (composed for North America). ISO...
-
Fire Suppression Systems - (269 companies)Fire suppression systems are used to suppress flames in the event of a fire. There are several types of suppression systems including wet sprinkler systems, dry sprinkler systems, deluge sprinkler systems and dry chemical suppression systems...
-
Heat Detectors - (104 companies)NFPA), a non-profit agency that publishes fire prevention codes and standards. Features. According to the National Fire Alarm Code (NFPA 72), heat detectors on smooth ceilings should be spaced 50 sq. ft. or 2500 sq. ft. apart. Otherwise, spacing...
-
Annunciators - (171 companies)Annunciators and graphic display panels disclose the layout and annunciate the status and measurement parameters of industrial processes, security and fire alarms of buildings and manufacturing facilities, power distribution networks, and other...
-
Traffic Safety Equipment - (375 companies)...vehicles or axles for traffic or traffic flow control. The sensor data would be fed into a traffic control or tolling system. Markers and indicators that are used in deep snow to locate fire hydrants and utility boxes are another example of traffic safety...
Product News
-
McGard Special Products Division
McGard Super Strength Fire Hydrant Lock McGard's Hydrant Lock is a super strength ultimate security solution. Features & Benefits: Controls water access and usage. Easy installation and operation. No modification needed to existing hydrants. Machined from alloy steel and ductile iron. Operating wrench comes equipped with a standard fireman 's tool and McGard operating key head. Environmentally sealed and electro-plated to resist the elements. Not affected by weather extremes. Heavy duty models available for most hydrant types... (read more) -
Lowell Corporation
Ratcheting Hydrant Wrenches When a hydrant has to be opened in a hurry, Lowell's three rugged, ratcheting hydrant wrenches make the job faster and easier. Mount a wrench on a pentagonal or square nut, tighten the thumb screw, and you're in business. Long bolts or worn or frozen nuts? No problem. The Model 52F has a 15" iron handle, the Model 53F has a 20" iron handle, and the Model 252F has a stamped double handle and is 32 1/2" long. All three feature Lowell's heavy duty ratcheting mechanisms. The long handles of the 52F... (read more)Browse Wrenches Datasheets for Lowell Corporation -
Control Instruments Corp.
Meet Requirements of NFPA 86 w/LFL Monitoring vapors in the atmosphere gets rich enough to ignite or explode. The severity of this threat, to protect your personnel and facility, is why it 's essential that these processes be continuously monitored. It 's also why the the National Fire Protection Association (NFPA) establishes fire safety standards, including standards for safe operation of processes. For these particular processes, the NFPA 86: Standard for Ovens & Furnaces, which addresses the safe operation of ovens, dryers, furnaces... (read more)Browse Gas Instruments Datasheets for Control Instruments Corp. -
InfraTec GmbH
Fire Prevention - FIRE-SCAN Fire Preven tion - FIRE-SCAN. Fire protection with thermography solutions for companies and the environment. Surveillance of open areas and warehouses with fire detection and prevention systems. Thermal imaging cameras timely detect and locate critical temperature conditions. Contactless, high-resolution temperature measurement at great distances for early fire detection and prevention. Automatic documentation and alerting. Monitoring objects and fire even in case of smoke and dusty air. follow... (read more)Browse Heat Detectors Datasheets for InfraTec GmbH -
MSA Safety
TriGas Monitor System Helps Comply with NFPA 820 The TriGas X5000 Monitoring System is an integrated gas monitoring solution that helps plant operators comply with NFPA 820. The system consists of up to three sensors to alert personnel of gas leak hazards with on-board alarming and communication interface to plant and remote location control stations. Achieving NFPA 820 compliance for pumping stations, lift stations, influent headworks and wet wells associated with wastewater treatment plants that are all subject to flooding is ideal... (read more)Browse Gas Instruments Datasheets for MSA Safety -
Kuriyama of America, Inc.
Gear Up with Top-Quality Fire Equipment! firefighters everywhere with the highest quality fire hose, nozzles and support equipment in a timely fashion. Kuriyama Fire Products welcomes the opportunity to demonstrate our commitment to providing quality products at competitive prices. Over the years, our fire hose, fire nozzles and fire accessories have gained a reputation of being second to none in safety and reliability. That 's why at Kuriyama Fire Products, all of our fire hose and fittings conform to NFPA standards and carry a ten-year... (read more)Browse Fire Suppression Systems Datasheets for Kuriyama of America, Inc. -
Kuriyama of America, Inc.
Fire Products for America’s Best Firefighters to providing quality products at competitive prices. Over the years, our fire hose, fire nozzles and fire accessories have gained a reputation of being second to none in safety and reliability. That 's why at Kuriyama Fire Products, all of our fire hose and fittings conform to NFPA standards and carry a ten-year warranty. With a variety of fire hose and nozzles, along with accessories such as fire backpacks, our extensive product line allows us to provide the best fire solutions for every situation. (read more)Browse Fire Suppression Systems Datasheets for Kuriyama of America, Inc. -
Kuriyama of America, Inc.
50 Years of Fire Hose and Nozzle Innovation with 50 years of manufacturing experience, you can rest assured our products are reliable and dependable, for when you need them the most. We offer equipment for a variety of firefighting needs, broken down into three categories: Municipal, Industrial, and Forestry. All Kuriyama Fire Products conform to NFPA standards and our ARMTEX (R) hoses carry a ten-year warranty. Kuriyama Fire Products is headquartered in Peterborough, NH. Our products are manufactured and fabricated at our four manufacturing... (read more)Browse Industrial Hose Datasheets for Kuriyama of America, Inc. -
Assured Automation
FM Fire-Safe Thermal Shutoff Ball Valves . Limit Switch: NEMA 4/4X , Weatherproof, Intrinsically safe, SPST , NO, Red LED. NEMA 4/4X /7 Weatherproof , Explosion proof, SPDT. Standards. National Fire Protection Association NFPA 58, (1979 Edition). OSHA 29 CFR 1910.106(b)(4)(iv)(c) Flammable Liquids. ANSI/API 607 Fire Test for Soft-Seated Quarter Turn Valves. The online configurator provides a part number and a quote, which can be saved, printed, emailed, or processed for purchase. More information on the FM Fire-Safe Shutoff... (read more) -
LAND
Prevent Battery Fires Protect Your People, Protect Your Profits, Prevent Battery Fires. The burgeoning adoption of lithium-ion batteries across industries has ushered in a new era of energy efficiency. However, this technological advancement comes with a significant caveat: the heightened risk of thermal runaway and subsequent fires. At AMETEK Land, we're committed to safeguarding lives and assets by offering cutting-edge solutions to mitigate these dangers. Our latest innovation, the LWIR-640 smart radiometric... (read more)
-
Facility Piping Systems Handbook: For Industrial, Commercial, and Healthcare Facilities, Third Edition > LIQUID FUEL STORAGE AND DISPENSING SYSTEMS
Bollards are the most often used and are similar to those used to protect fire hydrants . .... The principal code is NFPA -20, Fire Pumps.
-
States > Delaware > State > Regulations > Title 1 - Authorities‚ Boards and Commissions > 700 - Delaware State Fire Prevention Commission > [1 DE Admin C...
2.7 The steamer connection of all fire hydrants shall be positioned so as to be facing the edge of the street, or traffic lane. .... When required by the State Fire Marshal, minimum four inch (4") diameter steel bollards filled with concrete .... 3.7.1 Signs using NFPA international symbols shall be an acceptable alternative.
Indicates content that may require registration and/or purchase.