-
Supplier: Milwaukee Cylinder
Description: Nitrogen-over-oil Accumulators are designed for use over a wide range of industrial applications. Built to the same high quality standards maintained on Milwaukee Cylinder Air and Hydraulic Cylinders, Series NA Accumulator can be applied to: • Simplify hydraulic circuit design •
- Capacity: 2,299.9999999999995 cubic inches
- Operating Pressure: 3,000 psi
- Technology Type: Piston
- Housing Material: Steel
-
Supplier: HydraCheck Inc.
Description: The HydraCheck accumulator nitrogen charging assembly is used for charging accumulators with a Schrader-style (Vg8, .305-32) valve connection. This 3000 PSI (207 bar) accumulator nitrogen precharge test consists of: Gauge Assembly Drain cock Tank valve 3000 PSI
- Features: Other
-
Supplier: Eaton Hydraulics Group
Description: utilize the compressibility of nitrogen to store hydraulic energy in even the harshest environments. Piston Featuring a lightweight metal piston and a finished internal surface, Eaton piston accumulators leverage nitrogen’s compressibility to the fullest.
- Technology Type: Bladder, Diaphragm, Piston
-
-
Description: General: Used for charging of Accumulators with gas as well as pressure checking and adjustment. When charging, the nitrogen bottles must be capable of delivering pressure higher than the desired accumulator gas pressure. Construction: Standard version comprises Valve body
- Operating Pressure: 5,801.508 psi
-
Supplier: Valcor Engineering Corporation
Description: Our positive displacement hydraulic accumulators are self contained sources of hydraulic power storing nitrogen gas and hydraulic oil under pressure (nominally 3000 PSI). The expansion of the pressurized gas serves to expel the oil from the unit upon demand. The accumulator
- Capacity: 6.1 to 659.9999999999999 cubic inches
- Operating Pressure: 3,000 to 4,200 psi
- Technology Type: Piston
-
Description: gas - nitrogen - is filled into the gas side through a pressure valve to a pressure. The piston moves to the bottom end, filling the entire volume of the accumulator. When the system pressure is higher than the gas precharge pressure, the liquid enters the accumulator and the
- Capacity: 15.255948255948256 to 91,535.68953568953 cubic inches
- Operating Pressure: 3,190.8294 to 11,603.016 psi
- Housing Material: Aluminum, Steel, Steel - Stainless
- Technology Type: Piston
-
Description: accumulator shell. An inert gas - nitrogen - is filled into the diaphragm through a pressure valve to a pressure. The diaphragm expands, filling the entire volume of the accumulator shell. When the system (circuit) pressure is higher than the gas precharge pressure, the liquid
- Capacity: 4.576784476784477 to 305.1189651189651 cubic inches
- Operating Pressure: 580.1508 to 5,076.3195 psi
- Technology Type: Diaphragm
- Housing Material: Steel, Steel - Stainless
-
Description: accumulator shell. An inert gas - nitrogen - is filled into the diaphragm through a pressure valve to a pressure. The diaphragm expands, filling the entire volume of the accumulator shell. When the system (circuit) pressure is higher than the gas precharge pressure, the liquid
- Capacity: 6.102379302379301 to 152.55948255948255 cubic inches
- Operating Pressure: 3,045.7917 psi
- Technology Type: Diaphragm
- Housing Material: Steel, Steel - Stainless
-
Description: At Frick® by Johnson Controls, we engineer our Vertical Accumulators to provide protection for refrigeration vapor compressors by preventing occasional liquid in the suction line from entering the suction of the compressors. Our high quality refrigeration accumulator features a 12-96
- Volume Capacity: 0.1496104 to 1,692.093624 gallons
- Diameter / Width: 12 to 96 inch
- Pressure Rating: 250 to 300 psi
- Diameter: 12 to 96 inch
-
Supplier: MAXPRO Technologies, Inc.
Description: nitrogen Features Available for plant air or nitrogen drive Nitrogen drive units include: high pressure regulator with gauge gas supply pressure switch to stop booster when supply bottle pressure is too low dry air spool modification on the booster for longer service life All
- Bore Size - LP Inlet: 0.25 inch
- Bore Size - HP Outlet: 0.25 inch
- Fluid Compatibility: Gas
- Technology Type: Pneumatic
-
Supplier: MAXPRO Technologies, Inc.
Description: nitrogen Features Available for plant air or nitrogen drive Nitrogen drive units include: high pressure regulator with gauge gas supply pressure switch to stop booster when supply bottle pressure is too low dry air spool modification on the booster for longer service life All
- Bore Size - LP Inlet: 0.25 inch
- Bore Size - HP Outlet: 0.25 inch
- Fluid Compatibility: Gas
- Technology Type: Pneumatic
-
Supplier: HydraCheck Inc.
Description: charging unit allows hydro-pneumatic accumulators to be charged with nitrogen. For this purpose, the charging kit is connected to a commercially available nitrogen bottle via a flexible charging hose (8 feet/2.44m). The units also allow maintenance personnel to check the current
- Features: Other
-
Supplier: HydraCheck Inc.
Description: gauging units allow hydro-pneumatic accumulators to be charged with dry nitrogen. For this purpose, a charging and gauging unit is connected to a commercially available nitrogen bottle via a flexible charging hose (8 feet/2.44m). These units allow maintenance personnel to check
- Features: Other
-
Supplier: MAXPRO Technologies, Inc.
Description: nitrogen Features Available for plant air or nitrogen drive Nitrogen drive units include: high pressure regulator with gauge gas supply pressure switch to stop booster when supply bottle pressure is too low dry air spool modification on the booster for longer service life All
- Bore Size - LP Inlet: 0.25 inch
- Bore Size - HP Outlet: 0.25 inch
- Fluid Compatibility: Gas
- Technology Type: Pneumatic
-
Supplier: MAXPRO Technologies, Inc.
Description: nitrogen Features Available for plant air or nitrogen drive Nitrogen drive units include: high pressure regulator with gauge gas supply pressure switch to stop booster when supply bottle pressure is too low dry air spool modification on the booster for longer service life All
- Bore Size - LP Inlet: 0.25 inch
- Bore Size - HP Outlet: 0.25 inch
- Fluid Compatibility: Gas
- Technology Type: Pneumatic
-
Supplier: SAE International
Description: provided. Nitrogen leakage from accumulators is also a source of gas in hydraulic systems and may compose a portion of the "air" in the hydraulic system. The term "air" in this report does not differentiate between a gas composed strictly of normal atmospheric air or one that includes
-
Supplier: Breaker Technology, Inc.
Description: material conditions. Oil regeneration system; increases bpm's wothout decreasing enery in harder matieral applications. High volume nitrogen charged accumulator; provides constant blow energy and recoil absorption. Extra-long stroke pressure balanced piston in conjunction with oil
-
Supplier: Jaygo, Inc.
Description: applications in the pharmaceutical, chemical, food and mining industries. The valve can be supplied with an optional full fail-safe system. In this case, the valve closes whenever there is a loss of electric power or compressed air/nitrogen. When a failure occurs, a pressurized
- Valve Size: 19.68505 inch
- Number of Ports: 2
- Media Temperature: 446 F
- Number of Ports/Ways: 2
-
Supplier: Jaygo, Inc.
Description: applications in the pharmaceutical, chemical, food and mining industries. The valve can be supplied with an optional full fail-safe system. In this case, the valve closes whenever there is a loss of electric power or compressed air/nitrogen. When a failure occurs, a pressurized
- Valve Size: 7.87402 inch
- Number of Ports: 2
- Media Temperature: 446 F
- Number of Ports/Ways: 2
-
Supplier: Jaygo, Inc.
Description: applications in the pharmaceutical, chemical, food and mining industries. The valve can be supplied with an optional full fail-safe system. In this case, the valve closes whenever there is a loss of electric power or compressed air/nitrogen. When a failure occurs, a pressurized
- Valve Size: 18 inch
- Number of Ports: 2
- Media Temperature: 400 F
- Number of Ports/Ways: 2
-
Supplier: Jaygo, Inc.
Description: applications in the pharmaceutical, chemical, food and mining industries. The valve can be supplied with an optional full fail-safe system. In this case, the valve closes whenever there is a loss of electric power or compressed air/nitrogen. When a failure occurs, a pressurized
- Valve Size: 8 inch
- Number of Ports: 2
- Media Temperature: 400 F
- Number of Ports/Ways: 2
-
Description: The Frick® Vertical Intercooler (VI) desuperheats booster compressor discharge gas prior to entering the high stage compressors. At times the intercooler may also serve as a suction accumulator for high temperature loads Features and Benefits The Frick® intercooler is designed and rated for
- Volume Capacity: 25.9574044 to 1,852.1019468 gallons
- Diameter / Width: 12.75 to 96 inch
- Diameter: 12.75 to 96 inch
- Type: Pressure Vessel
-
Supplier: H.O. Penn Machinery Company, Inc.
Description: hydraulics provide exceptional second gear hydraulic-to-rimpull match for better material handling. Ride Control System The optional Ride Control System provides a comfortable ride and excellent material retention. Nitrogen charged accumulator enables optimum cushioning over uneven
- Operating Weight: 24,180 lbs
- Travel Speed: 24.2 miles/hr
- Type: Wheel Loader
-
Supplier: H.O. Penn Machinery Company, Inc.
Description: power required to move loads at all engine speeds. Ride Control System The optional Ride Control System provides a comfortable ride and excellent material retention. Nitrogen charged accumulator enables optimum cushioning over uneven terrain for all loads and speeds. The system
- Operating Weight: 27,699 lbs
- Travel Speed: 23.400000000000002 miles/hr
- Type: Wheel Loader
Find Suppliers by Category Top
Featured Products Top
-
charging and gauging units allow hydro-pneumatic accumulators to be charged with dry nitrogen. For this purpose, a charging and gauging unit is connected to a commercially available nitrogen bottle via a flexible charging hose (8 feet/2.44m (read more)
Browse Hydraulic Accumulators Datasheets for HydraCheck Inc. -
charging and gauging units allow hydro-pneumatic accumulators to be charged with dry nitrogen. For this purpose, a charging and gauging unit is connected to a commercially available nitrogen bottle via a flexible charging hose (8 feet/2.44m). These units allow maintenance personnel to check the (read more)
Browse Hydraulic Accumulators Datasheets for HydraCheck Inc. -
by quick closing valves Inlet Stabilizer enhances pump performance and longevity Accumulator releases stored fluid during unwanted pressure drops Expansion Tank (read more)
Browse Pulsation Dampeners Datasheets for Plast-O-Matic Valves, Inc.
More Information Top
-
Bookshelf and Unified Agenda > Independent Agencies / Commissions > Nuclear Regulatory Commission > NUREG Series Publications > NUREG-1793 - Final Safety Evalu...
Note 21 on DCD Tier 2, Figure 10.3.2-1, specifies that the MSIVs and MFIVs are pneumatic-hydraulically actuated with a sealed nitrogen accumulator that provides the stored energy to close the valve.
-
Hydropneumatic storage technology for hybrid passenger cars
The engine is combined with a hydraulic hybrid system, storing energy in a nitrogen accumulator .
-
Bookshelf and Unified Agenda > Independent Agencies / Commissions > Nuclear Regulatory Commission > NUREG Series Publications > NUREG-1769 - Safety Evaluation ...
The instrument nitrogen system piping, valves, and flexible hoses that are part of the ADS valve nitrogen accumulator safety-related pressure boundary were realigned from the instrument nitrogen system to the backup instrument nitrogen to ADS.
-
Cryocoolers 10
For system N3, with a temperature level of 35-40 K, a solid nitrogen accumulator is used based on the crystalline lattice structure phase transition that occurs in solid nitrogen at 35 K.
-
CTD traction winch system and motion compensated crane
Primary system components include the a complete CTD Traction Winch System and Electro-Hydraulic Power Unit, nodding-boom crane assembly, two hydraulic cylinders and two hydraulic oil I nitrogen accumulators mounted within a single frame assembly.
-
Bookshelf and Unified Agenda > Independent Agencies / Commissions > Nuclear Regulatory Commission > NUREG Series Publications > NUREG-1785 - Safety Evaluation ...
Steam dump nitrogen accumulator and connecting piping is shown on the nitrogen supply system Flow Diagram HBR2-8606LR (sheet 2) as within the scope of components requiring an AMR.
-
Managing aging in nuclear power plants: Insights from NRC maintenance team inspection reports
for the nitrogen accumulator subsystems.
-
An Innovative Ultradeepwater Subsea Blowout Preventer (SSBOP) Control System Using Shape Memory Alloy Actuators
In this case the analog to the nitrogen accumulator is the battery pack which avoids the need to transmit at high voltage through the electric cable connecting master and slave controllers by providing sufficient power independently.
-
Downhole Blowout Preventer
The receiver unit consists of a pressure transducer and amplifier, analog to digital (AID) converter, single chip microcomputer (MCU), watch dog, power amplifier, battery power supply, oil/ nitrogen accumulator , solenoid-valve and a 3-way mud valve.
-
Force Modulator System
Nitrogen Accumulator Fill Port – This port is used to add or release nitrogen for the accumulator.
Indicates content that may require registration and/or purchase.