Supplier: Arjay Engineering
Description: Reliable monitoring of oil/water interface and emulsions The sensing probe continuously monitors the capacitance of the inserted probe. As the interface or emulsion layer (rag layer) crosses over the probe, a proportional 4-20 mA output is provided. Typical applications
- Maximum Operating Pressure: 1,500 psi
- Material Temperature Range: -76 to 500 F
- Output Options: Analog Current Signal (e.g., 4-20 mA)
- Features: Built-in Alarm / Indicator, Controller Functions, Digital Front Panel, Instrument / Sensor System, Sensor-Only, Submersible, Transmitter
-
Supplier: FineTek
Description: The EG Series is a magnetostrictive level transmitter used to accurately measure the changing level of liquids. The EG magnetostrictive level transmitter uses the principles of buoyancy and magnetostriction. Single and two-float designs are available. EGX
- Output Options: Analog Current Signal (e.g., 4-20 mA)
- Media Type: Liquid
- Communication Interface Options: Serial Interface
- Features: Transmitter
-
Supplier: Burkert Fluid Control Systems
Description: measurement is also possible with the Type 8188, typically an oil/water interface.
- Level Measurement Type: Continuous Level
- Media Type: Liquid
- Meter Technology Type: Radar / Microwave
- Features: Transmitter
-
-
Supplier: Oil-Rite Corp.
Description: Oil-Rite manufactures Lubrication Systems specifically to customer requirements. All systems are engineered, designed, manufactured and fully tested at Oil-Rite. This is an example of a custom built Circulating Oil System. This Circulating Oil System is a dual,
- Features: Adjustable Volume
- Feed Type: Circulating Oil
-
Supplier: SSI Technologies, LLC
Description: The Acu-Trac® NEMA6 liquid level transmitter is a non-contact transmitter that is a direct replacement for level senders on tanks with depths up to ≤ 3.0 meters (118 inches). The NEMA6 liquid level transmitter offers a choice of outputs (analog current loop;
- Measuring Range: 118.1103 inch
- Material Temperature Range: -58 to 212 F
- Features: Analog Current, Analog Voltage, Programmable, Top mount
- User Interface: Computer Controllable
-
Supplier: Arjay Engineering
Description: capacitance changes and a proportional signal output is provided. The unique processor and oscillation frequency combination make the 2880-FCM ideal for foam suppression applications. These include oil/water knock-out and treater trains, bulk separators, coalescing chambers,
- Maximum Operating Pressure: 1,500 psi
- Material Temperature Range: -76 to 500 F
- Features: Analog Current, Built-in Alarm / Indicator, Controller Functions, Instrument / Sensor System
- Meter Technology Type: Capacitive / RF Admittance
-
Supplier: Oil-Rite Corp.
Description: plate heat exchanger maintains a constant oil supply temperature. The heat exchanger used with this Circulating Oil System removes approximately 55,000 BTU/HR, and requires 15 GPM of cooling water at a 104° F maximum. A temperature actuated modulating water control valve
- Features: Adjustable Volume
- Feed Type: Circulating Oil
-
Supplier: CAS DataLoggers
Description: options for measuring transducers. Applications Include: Agricultural monitoring Tank level monitoring Water/wastewater Oil & Gas Environmental monitoring Weather monitoring
- Analog Input Channels: 8 #
- Operating Temperature: -40 to 149 F
- Inputs / Channels: 8 #
- Features: Data Acquisition Instrument / System, Stand Alone
-
Supplier: Gefran
Description: Microprocessor controller, format 48x48 / 96x96 (1/8 DIN - 1/4 DIN) manufactured using SM Technology. The instrument provides a complete operator interface, protected by a Lexan membrane that ensures level IP65 faceplate protection. It has 4 keys, two green LED displays, each with 4
- Control Signal: Analog Voltage, Current Loop, Serial / Digital, Switch / Relay Output
- Temperature: Cooling Control, Heating Control, RTD / Thermistor Controller, Thermocouple Controller
- Type: Current Loop (Transmitter) Input, DC Voltage Input, Resistive / Potentiometer Input
- Form Factor: DIN Rail
-
Supplier: Gefran
Description: provided for different protection levels, ranging from maximum protection (allowing only the active setpoint to be changed) to a level giving access to all parameters. The data storage page lets you save both work parameters and HW configuration parameters in separate files. Saving the
- Number of Zones (if applicable): 4 to 16 zones
- Type: Current Loop (Transmitter) Input, Network / Fieldbus Input
- Features: Datalogger, Multi-Function Controller, Rate Indication / Control
- Interface: Digital Front Panel, Ethernet / Networkable
-
Supplier: Gefran
Description: variables. Various types of control are available: ON/OFF, P, PI, PID both only heat or cool and double-action heat+ cool. In addition, the cool action can be set via indication of the cooling fluid used: air, oil, water. Calculation of the most appropriate process parameters is
- Number of Zones (if applicable): 4 zones
- Type: Current Loop (Transmitter) Input, Network / Fieldbus Input
- Features: Datalogger, Multi-Function Controller, Rate Indication / Control
- Interface: Digital Front Panel, Ethernet / Networkable
Find Suppliers by Category Top
Featured Products Top
-
Manual. Drawing. Brochures. Sample Specifications. 2880-OWI Probe Mounted Transmitter. The 2880-OWI Probe Mounted Transmitter provides reliable monitoring of oil/water interface and emulsions. The 2880-OWI sensing probe continuously monitors the capacitance of the inserted probe. As the interface or emulstion layer (rag layer) crosses over the probe, a proportional 4-20 mA output is provided. Typical applications include oil water separators, oil/water knock-out tanks, treater trains... (read more)
Browse Level Sensors Datasheets for Arjay Engineering -
Manual. Drawing. Brochure. Sample Specifications. Continuous level monitoring that won't foul or fail you. The 2880-LT uses HF capacitance technology -- no moving parts, no routine cleaning. Probe-mounted electronics with 4-20 mA output. 2880-LT Probe Mounted Transmitter. The 2880-LT provides reliable monitoring of liquids and solids for a continuous level output. The probe continuously monitors product levels to provide a proportional level signal for pumps, alarms or control system interface... (read more)
Browse Liquid Level Sensors Datasheets for Arjay Engineering -
Manual. Drawing. Brochure. Sample Specifications. Continuous level monitoring that won't foul or fail you. The 2880-LT uses HF capacitance technology -- no moving parts, no routine cleaning. Probe-mounted electronics with 4-20 mA output. 2880-LT Probe Mounted Transmitter. The 2880-LT provides reliable monitoring of liquids and solids for a continuous level output. The probe continuously monitors product levels to provide a proportional level signal for pumps, alarms or control system interface... (read more)
Browse Level Sensors Datasheets for Arjay Engineering -
Transmitter provides reliable monitoring of liquids and solids for a continuous level output. The probe continuously monitors product levels to provide a proportional level signal for pumps, alarms or control system interface. The 2880-LT sensing probe monitors the capacitance field around the active probe. As the volume of product increases in the vessel, the probe capacitance changes. A 4-20 mA output signal is provided for interface with customer controls and systems. A quick calibration can... (read more)
Browse Level Sensors Datasheets for Arjay Engineering -
Manual. Drawing. Brochure. Sample Specifications. Application Briefs. 2880-OWI Probe Mounted Oil Water Interface Transmitter. The 2880-OWI Oil Water Interface Transmitter provides reliable monitoring of oil/water interface and emulsions. The 2880-OWI sensing probe continuously monitors the capacitance of the inserted probe. As the interface or emulsion layer (rag layer) crosses over the probe, a proportional 4-20 mA output is provided. Typical applications include oil water separators, oil... (read more)
Browse Level Transmitters Datasheets for Arjay Engineering -
. Two analog outputs. Three configurable relay outputs. Safe Torque Off inputs. Internal 24 VDC control supply. 10.5 V reference supply for a potentiometer. The analog inputs can be configured for 0 -10 VDC or 0 -20 mA signals. One input also supports a -10 to +10 VDC range. This flexibility allows the drive to receive speed references and feedback from pressure, flow, temperature, level, and other process transmitters. Two of the discrete inputs can operate as pulse inputs up to 30 kHz... (read more)
Browse Electric Rotary Actuators Datasheets for ERSAELECTRONICS PTE. LTD.
More Information Top
-
Distillation Troubleshooting Complete Document
Plugging of a tap on the boot oil – water interface level transmitter locked its .
-
CR4 - Thread: K-TEK Level Transmitter
Q1: We used level transmitter ( interface oil & water type:float), k-TEk suddenly the readings change fast from high reading then goes down to normal (like the pulse) why?
-
CR4 - Thread: Interface Level Transmitter
Dear Sir, can send Remote seal interface level transmitter calculation steps for oil water saperator Please.
-
Separator Profiling: Kuito FPSO Case Study
Existing Level InstrumentsOn Kuito, the production separator level measurement was designed with conventional separate, single point instrument transmitters for oil / water interface and bulk oil level .
-
Separator Profiling: Kuito FPSO Case Study
On Kuito, the production separator level measurement was designed with conventional separate, single point instrument transmitters for oil / water interface and bulk oil level .
-
Case Study: Quick Production Facility
A level in the separator is controlled by a guide wave radar level and interface transmitter , which automatically control water and oil discharge pumps.
-
A capacitance-based tomography system for interface measurement in separation vessels
Differential pressure transmitters are also used for interface level measurement in water / oil /gas separators [131.
-
Real-time estimation of oil quantity in crude oil tanks
In this system, magnetostriction instruments are used to measure the water – oil interfaces , oil level and the temperature at several sampling positions; also, pressure transmitters are used to measure the oil (containing water) densities and height.
-
Performance Testing of an Integrated, Subsea Compact Separation System with Electrocoalescence for Deepwater Applications
The oil - water interface level in the end section of the Pipe Separator was measured with guided wave radar transmitters and also by a nucleonic level detector (i.e., a Tracerco Profiler™).
-
Real-Time Production Optimization of Oil and Gas Production Systems: A Technology Survey
Level (the height of oil to water or gas to oil interface in a separator), pressure, and temperature transmitters are probably most common.