Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: ABB Measurement & Analytics
Description: The FPD190 restriction plate has an orifice bore (and plate thickness) that is calculated to achieve the required restriction to the flow rate or pressure drop whilst maintaining plate integrity. A multi-restriction assembly, consisting of several plates in series,
- Applications and Industry: Flow Measurement
- Material: Steel - Stainless
- Media Type: Hydraulic Fluids, Other Gas
-
Supplier: Transcat, Inc.
Description: Product Highlights Excellent chemical resistance Weather resistant Flame retardant (without factory gaskets) Low friction (minimum wear) Orifice plate thickness 1/4" offering greater stability
- Operating Pressure: 3.61 psi
- Pipe Diameter: 16 inch
- Type: Orifice Plate
-
Supplier: Transcat, Inc.
Description: Product Highlights Excellent chemical resistance Weather resistant Flame retardant (without factory gaskets) Low friction (minimum wear) Orifice plate thickness 1/4" offering greater stability
- Operating Pressure: 0.7225 psi
- Pipe Diameter: 14 inch
- Type: Orifice Plate
-
-
Supplier: Transcat, Inc.
Description: Product Highlights Excellent chemical resistance Weather resistant Flame retardant (without factory gaskets) Low friction (minimum wear) Orifice plate thickness 1/4" offering greater stability
- Operating Pressure: 11.56 psi
- Pipe Diameter: 12 inch
- Type: Orifice Plate
-
Supplier: Transcat, Inc.
Description: Product Highlights Excellent chemical resistance Weather resistant Flame retardant (without factory gaskets) Low friction (minimum wear) Orifice plate thickness 1/4" offering greater stability
- Operating Pressure: 3.61 psi
- Pipe Diameter: 12 inch
- Type: Orifice Plate
-
Supplier: Daniel Measurement and Control Inc.
Description: Daniel orifice plates conform to the most stringent manufacturing processes to achieve optimum accuracy standards in the industry. They are the most commonly used method of differential pressure flow measurement due to their simplicity, predictable and reliable performance, ease of
- End Fittings: Plain End
- Process Media Type: Gas
- Type: Orifice Plate
-
Supplier: ABB Measurement & Analytics
Description: Each assembly comprises an orifice plate mounted in (or integral with) a carrier that already has the correct tapping points fitted.
- Applications and Industry: Flow Measurement
- Material: Steel - Carbon and Alloy, Steel - Stainless
- Media Type: Hydraulic Fluids, Other Gas
-
Supplier: Madden Manufacturing, Inc.
Description: The Madden Orifice Meter gives the boiler operator precise repeatable control of the continuous blowdown flow rate. 17 different hole sizes are drilled in the stainless steel orifice plate. Each hole is precision drilled to a diameter that will produce the flow shown on he flow
- Type: Orifice Plate
-
Supplier: ABB Measurement & Analytics
Description: in two versions – one for volumetric flow and one for mass (or corrected volume) flow. Versatile metering package for low flowrates and small pipelines – Available with or without upstream/downstream pipework; wide choice of orifice plate bores gives a range of DP
- Electrical Output: Analog Current
- End Fittings: Flanged
- Features: Averaging / Multi-Insertion
- Mounting Type: In-line
-
Supplier: ABB Measurement & Analytics
Description: operation associated with impulse line leakage – as well as installation errors – are virtually eliminated. Low cost maintenance – Pressure-tested in the factory for leak prevention – Removable orifice plates for on site, low cost solutions to changes in process data or element
- Electrical Output: Analog Current
- End Fittings: Flanged
- Features: Measures Temperature, Audible or Visual Alarms
- Media Temperature Range: -382 to -4 F
-
Supplier: Bell & Gossett, a xylem brand
Description: The Circuit Sensor Flow Meter is a precision machined wafer-type orifice insert that is installed between standard 125, 150, 250 or 300 psi ANSI flanges, to monitor system flow with a minimum friction head loss. System flow is determined by obtaining a differential pressure across the flow
- End Fittings: Flanged, Other
- Operating Temperature: 250 F
- Pipe Diameter: 2.5 to 12 inch
- Process Media Type: Liquid
-
Supplier: Clark Solutions
Description: Use the 7000/8000 series flow meters for measuring the flow rate of liquids, gases, compressed air and steam in closed pipes. We also make indicating flow switches and flow transmitters for process indication and control. Meters feature a large easy to read analog dial with 270 degree pointer
- Liquid Volumetric Flow Rate: 2 to 500 GPM
- Electrical Output: Analog Current, Frequency, Switch
- End Fittings: Threaded, Other
- Features: Recorder / Totalizer Functions
-
Supplier: Accuris
Description: Orifice Plate Installation Details
-
Supplier: SAE International
Description: This part of SAE J968 specifies the flow measuring system, including the fixture, to be used for flow testing the single hole orifice plates used in an orifice plate type nozzle and holder assembly (described in SAE J968-1) which is intended for testing and setting diesel
-
Supplier: Victaulic Co. of America
Description: ORIFICE TYPE 406 C FLOW RATE 12 INCH NOMINAL SIZE 12 NOMINAL SIZE - DECIMAL 12 NOMINAL SIZE - FRACTIONAL CARBON STEEL BODY MATERIAL 250 PSI WATER AT 230 DEG F PRESSURE RATING 12 INCH IPS GROOVED X 12 INCH IPS GROOVED END CONNECTION 5 INCH END TO END DISTANCE APPROXIMATE WEIGHT 21.2 LB NOMINAL
- Operating Pressure: 250 psi
- Pipe Diameter: 12 inch
- Type: Orifice Plate
-
Description: The described system and fixture ensure accurate flow-testing of the entire range of orifices from 0,4 mm to 0,8 mm diameter. This second edition cancels and replaces the first edition (1985). Annexes A and B are for information only.
-
Supplier: Chonghong Industries(Microwork)Ltd.
Description: hydraulics and high-pressure applications. Brass threaded orifices are finding use in many deep bore applications and cylinder mount orifice designs. These inserts are available in our complete line of orifices from .0004? thru .081? Plated Stainless Orifice
- Material: Brass, Steel - Stainless
- Orifice Diameter: 4.00E-4 to 0.0810 inch
-
Supplier: IHS ESDU
Description: ESDU 81039 provides basic data for use in the calculation of pressure losses for incompressible flow (generally liquid flow) in ducts containing orifice plates, perforated plates and thick orifice plates or in the determination of a suitable geometry for a pressure
-
Supplier: Spirax-Sarco
Description: The M410 orifice plate and carrier assembly is a primary flow element consisting of a tab handled square edged orifice plate and optional carrier. The orifice plate is designed and manufactured to meet the requirements of British Standard BS 1042 and
- End Fittings: Flanged
- Mounting Type: In-line
- Pipe Diameter: 2.87 to 29.53 inch
-
Supplier: Oil-Rite Corp.
Description: component in lubricating systems and in a multitude of applications involving fluid transfer. The body of the flow sight is plated steel. Viton seals are used. The Lexan (plastic) sight features a pressure-tight, solid gasket design. The orifice diameter is 1/8". The hex size is 13/16”
- Body / Housing: Steel
- Connection Type: Threaded - NPT
- Optical / Window: Other
- Pressure Rating: 125 psi
-
Supplier: Daniel Measurement and Control Inc.
Description: Daniel offers a complete line of reliable orifice flange unions. These flange unions are simple devices used for securely holding an orifice plate in a line, providing accurate and economical differential measurement with little or no maintenance. A slotted jackscrew separates
- English Size: 1 to 16 inch
- Material: Carbon & Alloy Steel
- Size: English
- Type: Pipe Fitting
-
Supplier: ASME
Description: This Standard specifies the geometry and method of use (installation and flowing conditions) for pressure differential devices (including, but not limited to, orifice plates, nozzles, and venturi tubes) when installed in a closed conduit running full and use to determine the flow-rate
-
Supplier: ASME Standards and Certification
Description: This Standard specifies the geometry and method of use (installation and flowing conditions) for pressure differential devices (including, but not limited to, orifice plates, nozzles, and venturi tubes) when installed in a closed conduit running full and use to determine the flow-rate
-
Supplier: CSA Group
Description: The described system and fixture ensure accurate flow-testing of the entire range of orifices from 0,4 mm to 0,8 mm diameter. This second edition cancels and replaces the first edition (1985). Annexes A and B are for information only.
-
Supplier: Cole-Parmer
Description: fluids'' compatibility. Body is PEEK. Port type of valve is a pad mount to blanking plate (not included). Two-way normally open and three-way universal operation, as well as different port type valves are also available—contact an Application Specialist.
- Power: 24 volts
- Pressure Rating: 29 psi
-
Supplier: RS Components, Ltd.
Description: AS series inline speed controllers from SMC. This series is lightweight and has the benefit of index plates to help identify points when multiple controllers are installed. AS inline flow controllers can be mounted in four different ways so can be used in various installations. Manufacturer
- Connection: Other
- Maximum Pressure: 14.5 to 145 psi
-
Supplier: AENOR
Description: Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 2: Orifice plates (ISO 5167-2:2022)
-
Supplier: Radwell International
Description: DISCONTINUED BY MANUFACTURER, ORIFICE PLATE AND GASKET REPLACEMENT FOR THERMOSTAT. FREE 2 YEAR RADWELL WARRANTY
-
Supplier: Fläkt Woods Group SA
Description: Ideal solution for the exact and quick air flow measuring and regulation. Composed of regulation plates, regulating nut or handle and regulation scale. Regulation plates form a virtually ideal measuring orifice which enables an easy and reliable measurement of the air flow.
-
Supplier: Watts
Description: Designed to automatically limit flow rate to a constant, adjustable, maximum by sensing differential pressure across a remote mounted orifice plate (field installed). The Orifice Plate is factory calibrated based upon minimum, maximum, and continuous flow rate
- Primary Material of Construction: Stainless Steel
- Valve Size: 4 to 16 inch
- Valve Type: Control Valves
-
Supplier: Watts
Description: Designed to automatically limit flow rate to a constant, adjustable, maximum by sensing differential pressure across a remote mounted orifice plate (field installed). The Orifice Plate is factory calibrated based upon minimum, maximum, and continuous flow rate
- Material: Ductile Iron
- Valve Size: 1.25 to 16 inch
-
Supplier: ASTM International
Description: following components: plenum chamber assembly; orifice plate; orifice plate holder and assembly; manometer connection; and acceptable machined edges for orifice plates.
-
Supplier: Cole-Parmer
Description: These gauges are used to measure fan and blower pressures, filter resistance, air velocity, furnace draft, pressure drop across orifice plates, liquid level with bubbler systems. They can be flush or surface mounted. The gauge has a 4'' dial and requires 4-9/16'' hole for flush, panel
- Type: Differential
-
Supplier: Radwell International
Description: WIRELESS COMPACT CONDITIONING ORIFICE PLATE FLOW METER, UP TO 200:1 (14:1 FLOW TURNDOWN), 2000 PSI, 50-300MM, 316 SST. FREE 2 YEAR RADWELL WARRANTY
-
Supplier: Victaulic Co. of America
Description: Pressures up to 365psi | 2517 kPa | 25bar Rated from -4°F to 250°F | -20°C to 120°C Series 76T, 76B, 76K, 76V Sizes from ½-2? | DN15-DN50 Contains an automatic cartridge with a replaceable orifice plate
- Media Temperature: -4 to 250 F
- Pressure Rating: 365 psi
- Primary Material of Construction: Brass / Bronze, Ductile Iron
- Valve Size: 0.5000 to 6 inch
Find Suppliers by Category Top
Featured Products Top
-
The most popular Densometer sold for measuring porosity and air permeability in materials of average values. With options such as smaller orifice plates, materials of lower permeability may be effectively tested. By using a 5 oz. cylinder, materials of a higher permeability can be tested (Model (read more)
Browse Property Testing Equipment Datasheets for Gurley Precision Instruments -
applications including natural gas wellheads, burners or ovens, cooling systems, HVAC and more. Wafer-Cone technology requires virtually no maintenance, offering cost-of-ownership advantages over traditional DP technologies such as the orifice plate. The beta edge of an orifice place wears down (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
-Cone reduces permanent pressure loss by 75% compared to a traditional orifice plate. In addition, steam flooding requires multiple meters to monitor the process that must operate over the life of the field with low maintenance requirements to make the operation cost-effective. The V-Cone Flow Meter (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
welding. INNOVACERA’s welding processes include brazing and glass welding to meet the different needs of our customers. Orifice Plates INNOVACERA’s many years of experience in metallization and ceramic-to-metal production enable us to provide solutions according to your requirements. Our ceramic-to-metal components are ideal for use in high vacuum, High voltage, and high-pressure applications. (read more)
Browse Aluminum Oxide and Alumina Ceramics Datasheets for Xiamen Innovacera Advanced Materials Co., Ltd. -
sizes from 0.5 to 120 inches. With its unique ability to self-condition flow, the V-Cone Flow Meter is a real space-saver, eliminating the need for up/down stream straight pipe runs required by other DP technologies, such as orifice plates and venturi tubes. It can be installed virtually (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
technologies, such as orifice plates and Venturi tubes. It can be installed virtually anywhere in a piping system or be easily retrofit into an existing piping layout, resulting in significant installation flexibility and initial cost savings. Unlike traditional DP instruments such as orifice plates (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
self-condition flow, the V-Cone Subsea Flow Meter is a real space-saver, eliminating the need for long up/down stream straight pipe runs required by other DP technologies, such as orifice plates and venturi tubes. It can be installed virtually anywhere in a piping system or be easily retrofit into (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
unique ability to self-condition flow, the V-Cone Flow Meter is a real space-saver, eliminating the need for up/down stream straight pipe runs required by other DP technologies, such as orifice plates and venturi tubes. It can be installed virtually anywhere in a piping system or be easily retrofit into an existing piping layout, resulting in significant installation flexibility and initial cost savings. (read more)
Browse Flow Meters Datasheets for McCrometer, Inc. -
. Vooner uses the orifice plate method for measuring actual airflow at vacuum levels for a pump. The performance test results are put into a report which shows the total wasted energy and the seal water included in the lifetime cost of ownership. From this report, Vooner’s engineering staff is (read more)
Browse Dewatering Equipment Datasheets for Vooner FloGard LLC -
Vooner FloGard liquid ring cone ported vacuum pumps. To insure economic performance Vooner offers performance testing of dewatering equipment such as vacuum boxes, showers, piping, and vacuum pumps. Vooner uses the orifice plate (read more)
Browse Dewatering Equipment Datasheets for Vooner FloGard LLC
Conduct Research Top
-
Flow Measurement
devices are there to choose from? There are types that create an obstruction in the pipe and measure the differential pressure across this obstruction. This includes the age-old orifice plate and venturi meter. Does your customer really want to pay for this pressure drop for the life
-
Flow Energy Management Part 3: Three Successful Flow Energy Management Case Studies
quality crab and maximizing the efficiency of the plant's process. Previously, the plant used volumetric orifice plates for their steam measurement, which had three key disadvantages: The orifice plates did not measure pressure and temperature at the same point, which led to errors in mass flow
-
Bringing Energy Efficiency and Cost Savings to Veteran's Facilities
in the system. Now the question become what technology provides the most accurate steam flow measurement?Traditionally, steam flow has been measured with a differential pressure device. This is typically an orifice plate. However, such devices are inherently volumetric flow measurements. Changes in pressure
More Information Top
-
ISA IND FLW MEASRMNT - Industrial Flow Measurement
Orifice Plate Flowmeters, 117 .
Indicates content that may require registration and/or purchase.