Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Accuris
Description: Standard Specification for Transportation Tunnel Structural Components and Passive Fire Protection Systems
-
Supplier: Accuris
Description: Determination of the resistance to jet fires of passive fire protection materials Part 1: General Requirements
-
Description: ISO 22899-1:2007 describes a method of determining the resistance to jet fires of passive fire protection materials and systems. It gives an indication of how passive fire protection materials behave in a jet fire and provides performance data
-
-
Supplier: CSA Group
Description: ISO 22899-1:2007 describes a method of determining the resistance to jet fires of passive fire protection materials and systems. It gives an indication of how passive fire protection materials behave in a jet fire and provides performance data
-
Supplier: Accuris
Description: Passive and Reactive Fire Protection to Structural Steel
-
Supplier: Accuris
Description: Determination of the resistance to jet fires of passive fire protection materials \x97 Part 1: General requirements
-
Supplier: IHS BRE Press
Description: Get up-to-date information on passive and reactive fire protection to structural steelwork. This Information Paper provides information on the options available to the designer, ranging from the use of unprotected steelwork to the selection of products for extreme events such as
-
Supplier: ASTM International
Description: 1.1 This specification is applicable to the fire resistance of concrete tunnel linings, fire-resistive materials, and structural tunnel members. 1.2 Concrete mix design, tunnel linings, and passive fire protection methods are specific to each tunnel project.
-
Description: The test specified in ISO 22899-1 is designed to give an indication of how passive fire protection materials will perform in a jet fire. ISO/TR 22899-2:2013 provides: background information on the applicability and validation of the jet fire test; further details
-
Supplier: CSA Group
Description: The test specified in ISO 22899-1 is designed to give an indication of how passive fire protection materials will perform in a jet fire. ISO/TR 22899-2:2013 provides: background information on the applicability and validation of the jet fire test; further details
-
Supplier: AkzoNobel N.V.
Description: requirement to ensure the wellbeing of people at work and at home. If appropriate fire safety provisions are not made, including passive fire protection, the economic and social effects of fire could be catastrophic. We offer protection of your assets from
- Features: Other
-
Description: Standard for Fire Testing of Passive Protection Materials for Use on LP-Gas Containers. Use this Standard to evaluate the fire performance characteristics of passive protection materials applied to the exterior of liquefied petroleum (LP) gas containers in a
-
Supplier: SAE International
Description: Fire protection, active and passive, has been, and is, an important area of concern during the design, development and deployment phases for all modern ground vehicles. All US military vehicles carry handheld fire extinguishers, and many tactical and all combat vehicles
-
Supplier: CSA Group
Description: correction factor and practical constraints on the use of the fire protection system (the physical performance), and b) on the basis of the temperature data derived from testing unloaded short steel specimens, the thermal properties of the fire protection material (the
-
Supplier: CSA Group
Description: (Annex G). ISO 834-10:2014 is applicable to both passive and reactive fire protection systems as defined in the terms and definitions, which are installed or applied in such a way that they remain in place for the intended duration of fire exposure. The fire test
-
Supplier: Thermal Ceramics
Description: underground construction Systems are tested to many international standards and have approvals valid worldwide for cellulosic, hydrocarbon and jet fire protection. FireMaster products offer fire, thermal and acoustical fire protection in a single product, and due
- Features: Specialty / Other
-
Supplier: UL Standards & Engagement
Description: Fire Tests of Fire-Protective Curtain Assemblies UL 10D 1.1 These requirements cover the evaluation of fire-protective curtain assemblies intended to provide supplemental, passive fire protection as part of an engineered fire protection system.
-
Supplier: Houghton International, Inc.
Description: Houghton’s Cosmolubric® B series fluids are vegetable oil derived, fire-resistant, and formulated with additives to enhance corrosion protection, metal passivation and oxidation inhibition. The naturally low Total Acid Number extends the service life of the fluid. Cosmolubric B series
- Type: Fluid / Oil
- Features: Specialty
-
Description: the other, especially when NFIRS are outside the scope of NFPA 921. Chapter 8, Fire Protection Systems, was renamed Active Fire Protection Systems since passive systems are addressed in Chapter 7, Building Systems. New images and illustrations were added based on
-
Supplier: SAE International
Description: This Aerospace Standard (AS) specifies the minimum design and performance criteria and testing methods of passive fire resistant containers (FRCs) used either: a In those cargo compartments of civil transport aircraft where they constitute one means of complying with applicable
-
Description: achieving cryogenic spill protection do not currently exist. But through extensive testing advanced by Sherwin-Williams, it is proven that FIRETEX M89/02syntactic epoxy insulant, in conjunction with the passive fire protection offered by the FIRETEX epoxy intumescent,
- Wet / Applied Thickness: 0.393701 inch
- Features: Coating
- Chemistry: Epoxy, Resin Base / Polymer Binder
- Location / Orientation: Exterior
-
Supplier: AENOR
Description: Test methods for determining the contribution to the fire resistance of structural members - Part 4: Applied passive protection to steel members
-
Supplier: CSD Sealing Systems, LLC
Description: RISE/NOFIRNO cable penetrations are the latest introduction to the CSD/Beele family of passive fire safety products. Based on revolutionary new NOFIRNO® technology, RISE/NOFIRNO offers ultimate flexibility for sealing cable penetrations. The system is comprised of just two simple
- Number of Cables: 1
- Cable Diameter: 0.1968505 to 2.4803163 inch
- Features: Accommodates Pre-terminated Cables, Firestop, Other
- Method: Adhesive / Compound
-
Description: environments and is rated to provide up to two hours of passive fire protection. FX5090 can be applied at the job site, at a steel fabricator’s facility, or at a fire protection applicator’s shop. It offers fire protection across an extensive range of
- Wet / Applied Thickness: 0.018 to 0.04 inch
- Cure / Dry Temperature: 41 to 73 F
- Operating / Use Temperature: 50 F
- Dispensing Method: Brush / Roll-on, Sprayable
-
Supplier: Legrand
Description: through firewalls and floors to ensure that the integrity of the fire rating is maintained. These fittings have been tested by Underwriters Laboratories Inc. to ASTM E814 UL1479, Fire Tests of Through-Penetration Firestops. The Flamestopper Thru-Wall/Floor Fittings offer a
- Features: Accommodates Pre-terminated Cables, Firestop
- Application: Fire Protection
- Shape: Square / Rectangular
-
Supplier: Aspen Aerogels, Inc.
Description: Pyrogel® XTF aerogel insulation provides superior thermal performance and passive fire protection (PFP) for pipes and vessels. As an all-in-one solution, Pyrogel XTF insulation reduces installation costs by eliminating the need for coatings and additional structural support
- Density: 12.5 lbs/ft³
- Thermal Conductivity: 0.14 to 0.62 BTU-in/hr-ft²-F
- Operating Temperature: 32 to 1,200 F
- Thickness: 0.4 inch
-
Supplier: Mid-Mountain Materials, Inc.
Description: Mid-Mountain has developed ARMATEX® ISF Coated Fabrics, which combine an intumescent coating on one side with a silicone coating on the other, resulting in a product that is excellent for use in passive fire protection. Originally developed for use as fire and smoke
- Overall Thickness: 0.028 inch
- Overall Width / OD: 60 inch
- Fabric Weight: 949.2 gsm
- Use Temperature: 449.6 F
-
Supplier: ASTM International
Description: This specification covers a method for evaluating insulation installed on steel or aluminium structural division as defined in IMO resolution A. 754 (18) to assure insulation is note degraded in the event of shock. The non-combustible passive fire protection insulation shall be
-
Supplier: ASTM International
Description: This specification covers a method for evaluating insulation installed on steel or aluminium structural division as defined in IMO resolution A. 754 (18) to assure insulation is note degraded in the event of shock. The non-combustible passive fire protection insulation shall be
-
Supplier: Aspen Aerogels, Inc.
Description: PyroThin helps increase battery packing density, lower weight, and have more efficient thermal management, all while meeting regulatory and manufacturer mandated battery safety requirements. As a direct descendent of our proven passive fire protection solution for the energy
- Thickness: 0.0787402 to 0.1181103 inch
-
Supplier: Houghton International, Inc.
Description: Cosmolubric® B-220 FMA is a vegetable oil based fire-resistant hydraulic fluid. The fluid is formulated with additives to enhance corrosion protection, metal passivation and oxidative inhibition. This fluid is a low-cost alternative to synthetic fire-resistant hydraulic fluids.
- Type / Function: Hydraulic Oil / Fluid
- Composition / Chemistry: Natural (Vegetable Oil / Animal Fat)
- Features: Specialty Oil / Fluid
-
Description: Under conditions like these, you can't afford anything less than safeguards provided by the world's leading anti-corrosive passive fire protection coatings for onshore and offshore hydrocarbon environments. Coatings that are performance tested to the widest range of fire
- Features: Coating, Flame Retardant / UL 94V-0 Rated, Heat Resistant / High Temperature, Other, Protective
- Location / Orientation: Exterior
- Industry: Marine, Process Equipment
- Substrate: Metal
-
Supplier: Mueller Company
Description: of fire hydrant tampering or by accident. They provide 24/7 protection and allow normal hydrant operation without any special tools, with virtually no effect on firefighters’ emergency use or normal hydrant maintenance. Level of Protection All hydrant security devices fall into
-
Supplier: Lydall Performance Materials
Description: Boilers Applications: Thermal/flame barrier for gas fired appliances Passive flame barrier system High temperature gaskets and seals Coated with PSA and slit into strips to be used as seals and thermal breaks Thermal insulation where space is at a premium Laminated or mechanically attached to
- Overall Thickness: 0.035 to 0.255 inch
- Overall Width / OD: 2 to 104 inch
- Fabric Weight: 176 to 780 gsm
- Use Temperature: 1,200 F
-
Supplier: Houghton International, Inc.
Description: Cosmolubric® HF-130 is a Factory Mutual approved high-quality synthetic polyol ester hydraulic fluid. Houghton formulated this chemically and thermally stable fluid for long life and dependable performance in areas where a fire-resistant hydraulic fluid is required. Besides having good
- Composition / Chemistry: Ester / Diester, Synthetic
- Type / Function: Hydraulic Oil / Fluid
- Features: Specialty Oil / Fluid
Find Suppliers by Category Top
Featured Products Top
-
Metal finishing for aerospace components requires meticulous processes to ensure the removal of contaminants and the highest quality results, including corrosion resistance for improved performance and longevity. What is Passivation? (read more)
Browse Corrosion Protection Services Datasheets for Able Electropolishing Company, Inc. -
Passivation is an essential finishing process enhancing the durability and efficacy of metal parts in industries with no room for error, such as (read more)
Browse Corrosion Protection Services Datasheets for Able Electropolishing Company, Inc. -
that ensures optimal fit, life cycle and corrosion resistance for these critical metal parts. In fact, electropolishing leaves parts 30 times more corrosion resistant than passivation alone, while also leaving parts in a passivated state. Learn more in our whitepaper, Electropolishing for Significantly Improved Corrosion Resistance, which includes three case studies. (read more)
Browse Corrosion Protection Services Datasheets for Able Electropolishing Company, Inc. -
can meet mechanical, thermal, and safety requirements without adding unnecessary complexity or volume. By combining insulation, chemical resistance, and passive fire protection at the component level, they provide durable, space-efficient protection inside increasingly dense rack environments (read more)
Browse Coated Fabrics Datasheets for Mid-Mountain Materials, Inc.
Conduct Research Top
-
3 Passive Fire Protections for Actuators
There are many dangers when extracting, transporting and refining oil & gas or any other dangerous materials. Two of the major ones are fires and explosions...
-
Passive or Active Grounding that is the Question?
For years now simple passive grounding has been used throughout industry as a low-cost safety measure and protection against fires and explosions caused by static electricity but is it as safe as you think?
More Information Top
-
SFPE Handbook of Fire Protection Engineering
Evaluation of Passive Fire Protection by Jet Fire Test Procedure, paper 4-d in 29th Loss Prevention Symp., American Institute of Chemical Engineers, New York (1995).
-
Offshore Risk Assessment
conditional probability of failure of the safety protective systems, such as ESD, blowdown, deluge, passive fire protection , etc., given that ignition has occurred pescal,n = .
-
Offshore Risk Assessment vol 2.
Passive Fire Protection .
Indicates content that may require registration and/or purchase.