Supplier: Victrex PLC
Description: higher strength in a static system. Low coefficient of thermal expansion. Chemically resistant to aggressive environments, suitable for sterilization for medical and food contact applications.
- Chemical / Polymer System Type: PEEK
- Coeff. of Thermal Expansion (CTE): 50 to 125 µin/in-F
- Compound Type: Molding Resin
- Deflection Temperature (@ 264 psi, 1.8 MPa): 298 F
-
Supplier: Victrex PLC
Description: as well as good ductility at higher temperatures. Chemically resistant to aggressive environments, suitable for sterilization for medical and food contact applications.
- Chemical / Polymer System Type: PEEK
- Coeff. of Thermal Expansion (CTE): 45 to 130 µin/in-F
- Compound Type: Extrusion Grade Resin, Molding Resin
- Deflection Temperature (@ 264 psi, 1.8 MPa): 163 F
-
Supplier: Victrex PLC
Description: and stiffness as well as high ductility. Chemically resistant to aggressive environments, suitable for sterilization for medical and food contact applications.
- Chemical / Polymer System Type: PEEK
- Coeff. of Thermal Expansion (CTE): 45 to 140 µin/in-F
- Compound Type: Molding Resin
- Deflection Temperature (@ 264 psi, 1.8 MPa): 152 F
-
-
Supplier: Victrex PLC
Description: stiffness as well as high ductility. Chemically resistant to aggressive environments, suitable for sterilization for medical and food contact applications.
- Chemical / Polymer System Type: PEEK
- Coeff. of Thermal Expansion (CTE): 35 to 140 µin/in-F
- Compound Type: Extrusion Grade Resin, Molding Resin
- Deflection Temperature (@ 264 psi, 1.8 MPa): 152 F
-
Autoclaves and Sterilizers - Saniclave 50 Top Loading Benchtop Autoclave, 8L, 120 VAC -- GO-10776-01Supplier: Cole-Parmer
Description: temperature display makes this sterilizer effortless to use. Durable construction with a thermally protective polymer exterior and corrosion-resistant stainless steel interior eliminate burn risk and provides easy-to-clean convenience. Additional features include a low water and
- Application / Industry: Laboratory
- Capacity: 0.2800 cubic feet
-
Supplier: Cole-Parmer
Description: • Dry mode to sterilize wrapped or unwrappd instruments • Simple and efficient horizontal loading • Simple one-button automatic operation starts the fast 30-minute sterilization cycle • Compact enough to sit on your benchtop Lightweight, portable yet robust
- Application / Industry: Laboratory
- Capacity: 0.3700 cubic feet
-
Supplier: Eastman Chemical Company
Description: Durastar™ Polymer MN611 has been tested for FDA/ISO 10993 and USP Class VI Biological Evaluation testing after Gamma and EtO sterilization. It contains a mold release to improve ejection. It has excellent appearance and is nearly water-clear. Its most outstanding features are
- Deflection Temperature (@ 264 psi, 1.8 MPa): 149 F
- Elongation: 5 %
- Industry: Medical / Food (FDA)
- Tensile Strength (Break): 7397 psi
-
Supplier: Eastman Chemical Company
Description: DuraStar™ Polymer MN621 has been tested for FDA/ISO 10993 and USP Class VI Biological Evaluation testing after Gamma and EtO sterilization. It contains a mold release to improve ejection. It processes easily and requires minimal drying time. It has superior toughness, high clarity and
- Deflection Temperature (@ 264 psi, 1.8 MPa): 149 F
- Elongation: 5 %
- Industry: Medical / Food (FDA)
- Tensile Strength (Break): 7687 psi
-
Supplier: Eastman Chemical Company
Description: DuraStar™ Polymer MN631 has been tested for FDA/ISO 10993 and USP Class VI Biological Evaluation testing after Gamma and EtO sterilization. It contains a mold release. It has excellent appearance and is nearly water-clear. Its most outstanding features are toughness, chemical
- Deflection Temperature (@ 264 psi, 1.8 MPa): 151 F
- Elongation: 5 %
- Industry: Medical / Food (FDA)
- Tensile Strength (Break): 6237 psi
-
Supplier: MCG - Performance Polymers Division
Description: TECHNOLOGIES ZELAS™ polymers product range is comprised of 4 groups covering a wide range of properties, designed for film, tube and injected components for medical applications: R-TPO: Reactor TPO for film manufacturing or injection molding TPE: Modified
- Compound Type: Film Grade Resin, Extrusion Grade Resin, Molding Resin
- Industry: Medical / Food (FDA)
- Material Type / Grade: Thermoplastic
-
Supplier: ASTM International
Description: unit EEK. As with any material, some characteristics may be altered by the processing techniques (molding, extrusion, machining, assembly, sterilization, and so forth) required for the production of a specific part or device. Therefore, properties of fabricated forms of these polymers
-
Supplier: ASTM International
Description: This specification covers virgin polyetherketoneketon e (PEKK) polymer resin as supplied by a vendor (for example, in pellets, powder, and fabricated forms). It provides requirements and associated test methods for these thermoplastics when they are to be used in the manufacture of
-
Supplier: ASTM International
Description: 1.1 This specification covers polyaryletherketone (PAEK) polymers in virgin forms as supplied by a vendor (pellets, powder, and so forth). It provides requirements and associated test methods for these thermoplastics when they are to be used in the manufacture of intracorporeal devices such
-
Supplier: ASTM International
Description: 1.1 This specification covers polyetheretherketone (PEEK) polymer in virgin forms as supplied by a vendor (pellets, powder, and so forth). It provides requirements and associated test methods for these thermoplastics when they are to be used in the manufacture of intracorporeal devices
-
Supplier: Teknor Apex Company
Description: Material Status Commercial: Active Availability Asia Pacific Features Ethylene Oxide Sterilizable Non
- Chemical / Polymer System Type: PolyVinyl Chloride (PVC)
- Compound Type: Molding Resin
- Industry: Medical / Food (FDA)
- Material Type / Grade: Thermoplastic
-
Supplier: Teknor Apex Company
Description: Material Status Commercial: Active Availability Asia Pacific Features Ethylene Oxide Sterilizable Uses Medical
- Chemical / Polymer System Type: PolyVinyl Chloride (PVC)
- Compound Type: Extrusion Grade Resin
- Industry: Medical / Food (FDA)
- Material Type / Grade: Thermoplastic
-
Supplier: Teknor Apex Company
Description: Material Status Commercial: Active Availability Asia Pacific Features Ethylene Oxide Sterilizable Uses Medical
- Chemical / Polymer System Type: PolyVinyl Chloride (PVC)
- Compound Type: Extrusion Grade Resin
- Industry: Medical / Food (FDA)
- Material Type / Grade: Thermoplastic
-
Supplier: Teknor Apex Company
Description: Material Status Commercial: Active Availability Asia Pacific Features Ethylene Oxide Sterilizable Uses Medical/Healthcare Applications Forms Granules
- Chemical / Polymer System Type: PolyVinyl Chloride (PVC)
- Industry: Medical / Food (FDA)
- Material Type / Grade: Thermoplastic
- Resins & Compounds: Pellets
-
Supplier: Eastman Chemical Company
Description: Eastar™ Copolyester MN021 Natural has been tested for FDA/ISO 10993 and USP Class VI Biological Evaluation testing after Gamma and EtO sterilization. It is a thermoplastic condensation copolymer produced by a continuous melt-phase polymerization process followed by a solid
- Chemical / Polymer System Type: Polyester (PET, PBT)
- Deflection Temperature (@ 264 psi, 1.8 MPa): 149 F
- Industry: Medical / Food (FDA)
- Material Type / Grade: Thermoplastic
-
Supplier: Ensinger North America
Description: ?Offering a level of performance above polysulfones, Ensinger's industrial grade TECASON P has increased temperature, impact and chemical resistance properties, as well as excellent resistance to repeated steam sterilization (autoclave) cycles. Main Features: High
- Chemical / Polymer System Type: Specialty / Other
- Coeff. of Thermal Expansion (CTE): 31 µin/in-F
- Deflection Temperature (@ 264 psi, 1.8 MPa): 405 F
- Dielectric Constant: 3.44
-
Supplier: Polygon Company
Description: PolyMed® combines lightweight materials and strong physical characteristics, as well as radiolucent and dielectric properties, thin walls, rigidity and the ability to be sterilized. PolyMed® composite medical tubing meets this stringent criteria, while at the same
-
Description: Features Soft and conformable for maximum versatility and patient comfort High tack adhesive bonds well to various materials Stable to ETO and gamma sterilization Good dimensional stability and lay flat Applications Electrode manufacturing including ECG, EKG, TENS, and AED defibrillator pads
- Adhesive: Acrylic
- Backing: Plastic / Polymer, Specialty / Other
- Peel Strength / Adhesion: 5.62 lbs/in
- Temperature Resistance: 15.56 to 26.67 C
-
Description: The cleanliness of Ethylene Oxide (EtO) typically varies from supplier to supplier and from delivery to delivery. In addition, EtO inherently polymerizes, causing valves to clog and regulators to malfunction. Filtering EtO at the point of use assures the delivery of clean EtO to the
- Filter Media: Other
- Housing Material: Steel - Stainless
- Industry Use: Medical, Other
- Maximum Pressure: 250 psi
-
Supplier: Fluoro-Plastics, Inc.
Description: , unsupported hydrophobic membrane with broad chemical compatibility. It is compatible with various sterilizing methods (to 500 deg F, or 234 deg C). For these reasons it is extensively used as a barrier film in many applications. Thin film is widely used in the wire and cable industry as
- Carrier / Backing Material: Fluoropolymer, Plastic / Polymer
- Dielectric Strength: 1.97E7 V/m
- Features: Abrasion / Scratch Resistant, Dielectric / Insulating
-
Supplier: Valspar Corporation (The)
Description: sterilization (retort, pasteurization, and hot fill) Design for mild, medium, and aggressive food Non-PVC coatings Non-BPA* technologies Chemical and physical resistance/processin g -The next generation of closure technology Product Range
- Chemistry: Epoxy, Resin Base / Polymer Binder
- Form: Solvent Based
- Industry: Food and Beverage
- Substrate / Surface: Aluminum, Steel
-
Supplier: Parco Scientific Company
Description: .002") thick blended polymer, autoclavable to 138°C (280°F) and feature a sterilization indicator patch that darkens when exposed to steam sterilization. p>
- Length: 48.03 inch
- Type: Bag / Sack
- Volume Capacity: 40 to 50 gallons
- Width / Diameter: 37.01 inch
-
Description: ) in air and liquid filitration. Inert: UPE is stable under exposure to gamma radiation used for sterilization and has excellent resistance to most chemicals (including solvents). High strength and durability Excellent Abrasion and impact resistance
- Applications: Filtration
- Fabric Weight: 5 gsm
- Material Type: Synthetic / Polymer, Glass / Fiberglass
- Overall Thickness: 0.0016 inch
-
Supplier: Cambridge Polymer Group, Inc.
Description: , swelling analysis Biomedical Analysis Accelerated aging protocols, packaging analysis, device cleanliness studies, failure analysis, sterilization procedures, oxygen content, Vitamin E characterization Mechanical Analysis Dynamic mechanical
- Capabilities: Assays / Quantitative, Cleanliness Monitoring / Testing, Deformulation / Reverse Engineering, Failure Analysis, Quality / Purity (Contamination - Alloys, Polymers, etc.), Report Preparation, Standards Testing / Certification, Umpire Testing, Other
- Industry Applications: Aerospace / Aviation, Automotive, Food / Beverage, Health Care / Medical, Legal / Forensics, Marine, Pharmaceutical / Biotech, Packaging
- Materials: Adhesives / Sealants, Coatings, Cosmetics (Creams, Sunblocks, etc.), Plastic / Rubber, Polymers / Organics, Powders, Textiles, Wafers / Surfaces, Other
- Regional Preference: North America, United States Only, Northeast US Only
-
Supplier: Sartorius Lab Instruments GmbH & Co. KG
Description: PESU polyethersulfone membranes are membrane polymers that are well established in the biotechnological and pharmaceutical industries. The PESU membrane is a stable polymer that features a broad pH and temperature range. Its wide temperature range makes it possible to sterilize
- Configuration: Filter Element Only
- Filter Medium Material: Polyethersulfone (PES)
- Filter Shape: Sheet (Rectangular)
- Filter Type: Membrane Filter
-
Supplier: Malema Sensors
Description: Covol volumetric counter is ideal meter for viscous fluids such as oils, waxes and polymers. The sensor is constructed in SS-316, PVC, PP and PTFE material options to suit corrosive applications. It can be easily cleaned and sterilized. Features Viscosity up to 120,000 mPa.s It will
- Liquid Volumetric Flow Rate: 0.0440 to 264 GPM
- Electrical Output: Analog Current
- End Fittings: Flanged, Threaded
- Features: Recorder / Totalizer Functions
-
Supplier: Cambridge Polymer Group, Inc.
Description: , swelling analysis Biomedical Analysis Accelerated aging protocols, packaging analysis, device cleanliness studies, failure analysis, sterilization procedures, oxygen content, Vitamin E characterization Mechanical Analysis Dynamic mechanical analysis
- Industry Applications: Aerospace / Aviation, Food / Beverage, Automotive, Chemical / Material Processing, Health Care / Medical, Legal / Forensics, Marine, Military, Pharmaceutical / Biotech, Packaging, Semiconductors / Electronics, Structural / Construction, Specialty / Other
- Materials: Adhesives / Sealants, Chemicals, Coatings, Composites, Cosmetics (Creams, Sunblocks, etc.), Inorganics, Nanomaterials, Paper, Petroleum Fluids (Oil, Fuel, Distillates), Plastic / Rubber, Polymers / Organics, Powders, Textiles, Thin Films / Plating, Wafers / Surfaces, Water
- Regional Preference: North America, United States Only, Northeast US Only
- Services Offered: Assays / Quantitative, Cleanliness Monitoring / Testing, Deformulation / Reverse Engineering, Environmental Exposure Testing, Materials Testing Services, Quality / Purity (Contamination), Report Preparation, Standards Testing / Certification, Umpire Testing, Other
-
Supplier: Cambridge Polymer Group, Inc.
Description: studies, failure analysis, sterilization procedures, oxygen content, Vitamin E characterization Mechanical Analysis: Dynamic mechanical analysis (DMA), tensile testing, compression testing, creep testing For a partial list of ASTM standards performed by Cambridge Polymer Group
- Industry: Automotive, Chemical / Material Processing, Food / Beverage, Health Care / Medical, Legal / Forensics, Pharmaceutical / Biotech, Semiconductors / Electronics, Specialty / Other
- Laboratory Services Offered: Assays / Quantitative, Chemical Testing Services, Cleanliness Monitoring / Testing, Deformulation / Reverse Engineering, Failure Analysis, Materials Testing Services, Report Preparation, Standards Testing / Certification, Other
- Materials: Adhesives / Sealants, Chemicals, Coatings, Composites, Cosmetics (Creams, Sunblocks, etc.), Fuel Cell / Battery Materials, Nanomaterials, Paper, Petroleum Fluids (Oil, Fuel, Distillates), Plastic / Rubber, Polymers / Organics, Powders, Solid Waste, Textiles, Volatiles (VOCs) / Solvents,
- Regional Preference: North America, United States Only, Northeast US Only
-
Supplier: Matexcel
Description: Storage: Dark, Dry, Room temperature Usage: 1.The recommended final concentration is 0.1-0.5%. Dissove temperation is 40-60?. The solution can be sterilized with a 0.22um filter. 2.It is recommended to use this solution for immediate use 3.LAP crosslinks within the
-
Supplier: Electro Optical Components, Inc.
Description: sterilization is required without having to forgo the renown advantages of Mid-IR FTIR spectroscopy. Applications: Reaction Monitoring in real time Process Analytical Technologies (PAT) Remote Polymerization Control Crystallization Process Screening In-situ IR-Spectroscopy for PAT in
- Bending Radius: 130 mm
- Cable Type: Duplex
- Connector Type: SMA
- Operating Temperature: -150 to 140 C
-
Supplier: Kent Elastomer Products, Inc.
Description: Thermoplastic Elastomer (TPE) is a soft and flexible polymer with excellent physical properties, making it a good alternative for many latex or silicone tubing applications. FDA, NSF and USP Class VI material compounds are available for medical and food/beverage applications
- Application: Medical / Pharmaceutical
- Material Choices: Plastic Tubing
Find Suppliers by Category Top
Featured Products Top
-
Gamma radiation is a common sterilization technique for medical products. Generally, polypropylene (PP) resins exposed to gamma or other high-energy radiation sources lose physical and mechanical properties after exposure. Vistamaxx performance polymers can enhance the flexibility and toughness of polymers, improving the performance of PP resins after gamma sterilization. (read more)
Browse Polymers and Plastic Resins Datasheets for ExxonMobil - Polypropylene Products -
Nylon 66 Structure: The "66" designation refers to the polymer's molecular structure, derived from two monomers—a diamine and a diacid—each containing six carbon atoms. This configuration ensures high mechanical strength and chemical stability (read more)
Browse Filter Elements Datasheets for Harbory Filtration -
ESPEC North America Inc | Qualmark Products and Services
HAST - Highly Accelerated Stress Test Chambers
insights, mitigating costly failures and enabling rapid design iteration. Medical Devices & Sterile Equipment Devices exposed to autoclaving, steam sterilization, or high humidity environments, like surgical instruments, implants, and diagnostic sensors- must withstand repeated (read more)
Browse Environmental Test Chambers and Rooms Datasheets for ESPEC North America Inc | Qualmark Products and Services -
encapsulation applications. EP21LSCL-2Med is specially formulated to have minimal non-yellowing tendencies. This system features a high glass transition temperature (Tg), good resistance to steam and water, liquid sterilants and EtO sterilization. The service temperature range is from -60°F to (read more)
Browse Industrial Adhesives Datasheets for Master Bond, Inc. -
. Durability of plastic composites allows them to withstand increased friction and heavy loads better than other types of material, including metals. Easier to clean and sterilize than metal, plastic composites play (read more)
Browse Plastic Molding Services Datasheets for Osborne Industries, Inc. -
temperature exposure or experience Clean-in-Place (CIP), Steam-in-Place (SIP) and Stage II sterilization. Perlast® perfluoroelastomer medical seals provide the ultimate in thermal and (read more)
Browse O-rings Datasheets for Precision Polymer Engineering Ltd. -
environments Cleanroom sealing solutions Sliding or quick-locking doors for autoclaves, sterilizers, dryers, and reactors Centrifugal filters (e.g., access doors and drainage hoppers) Industrial Applications Cofferdams for (read more)
Browse Inflatable Seals Datasheets for Technetics Group -
Isothermal chambers for controlled environments Cleanroom sealing solutions Sliding or quick-locking doors for autoclaves, sterilizers, dryers, and reactors Centrifugal filters (e.g., access doors and drainage hoppers) Industrial (read more)
Browse Dynamic Seals Datasheets for Technetics Group
Conduct Research Top
-
Sterilisation of Polymer Healthcare Products
Sterilisation of Polymer Healthcare Products. With the many possible ways to sterilize healthcare products, and new techniques being developed all the time, this book identifies the variety of factors that must be taken into account and offers a thorough description of the conventional methods.
-
Autoclaving Resistance of Medical Adhesives
Resistance to steam sterilization is an important consideration for the selection of polymeric adhesives, sealants and potting compounds for use in medical applications. Autoclaving is one of the most rigorous and widely employed sterilization methods for medical devices. With this in mind, Master
-
Application Development in the Medical Industry
for a medical device that includes the working environment the device will be used in. This is the case for instance when considering magnetic resonance (MR) assisted surgery. There are also questions as to potential changes in the polymer when it is exposed to traditional and new sterilization methods
-
Which to Choose-Stainless Steel or Single Use Technology (SUT)?
high-performance polymers for disposable components that have been sterilized using gamma irradiation. Over time, companies have sifted through the pros and cons of both types of technologies, SUTs and stainless steel, to determine the best options for business operations.
-
How to Size an Indirect Paddle Thermal Processor for Drying
a process mass. A paddle thermal processor can be used to dry, heat, sterilize, cool, react, torrefy, melt, pasteurize, strip solvents, calcine, roast, cook, or crystallize a wide variety of materials such as chemicals, pharmaceuticals, biosolids, food, waste, minerals, polymers, metals, and more.
-
Low-Risk Lyophilization
By Brian Bucur, Associate Director, Lyophilization & Sterilization and Timothy Smith, Director, Product & Process Development - Ben Venue Laboratories, Inc. An important consideration for the development stage of a lyophilized product is to consider selection of a stopper that has a coating or film
-
A Closer Look at Form-Fill-Seal Technology
technologies to minimize operator intervention and contamination risk in the filling and packaging of liquid parenteral drugs. One of these technologies is form-fill-seal (FFS), in which a polymeric material is formed and sealed inline to a container of choice, while the container is being filled. FFS offers
More Information Top
-
Handbook on Advanced Design and Manufacturing Technologies for Biomedical Devices
In some cases the method can produce a certain oxidation of the polymers sterilised by this method, as has been recorded in some “UHMWPE” implants.
-
Human pathogens, nosocomial infections, heat-sensitive textile implants, and an innovative approach to deal with them
Accordingly, dense gaseous, liquid or supercritical carbon dioxide (scCO2) (T [ 31°C, P [ 74 bar) is generally suitable, but has not been investi- gated in detail for (bio) polymer sterilization yet [36].
-
Methods for the Preparation and Manufacture of Polymeric Nanoparticles
Gamma irradiation is another effective method of polymer sterilization accepted by European Pharmacopeia which can be applied on heat-sensitive materials.
-
Aeration of ethylene oxide-sterilized polymers.
The ethylene oxide (EO) content of 17 polymers sterilized with 100% EO under conditions normally used in practice was determined as a function of aeration time, and for some polymers also as a function of sample thickness.
-
Cellular Transplantation-Based Evolving Treatment Options in Spinal Cord Injury
Although the synthetic polymers could be sterilized quite safely, there is some concern associated with the reliability of the natural polymer sterilization .
-
Polyethylene terephthalate membrane grafted with peptidomimetics: endothelial cell compatibility and retention under shear stress.
Cells were lost on non-grafted PET whereas cells on grafted polymers sterilized by γ-ray irradiation withstood forces with no significant difference in focal contacts.
-
Resorbable and Nonresorbable Hydroxyapatite Granules as Bone Graft Substitutes in Rabbit Cortical Defects
Immediately prior to surgery, the implants were placed in polymer sterilizing bags and were steam ster- ilized (prevacuum cycle, 120°C,20 min).
-
The Chemistry of Medical and Dental Materials
The effects of polymer cross – linking to enhance wear resistance, biological effects of wear particles and polymer debris, methacrylate monomer cytotoxicity as well as methods of polymer sterilization are also considered.
-
Studies of the healing of bone grafts, and the incorporation of titanium implants in grafted bone: an experimental animal model
Immediately before surgery, the implants were placed in polymer sterilizing bags and steam sterilized.