Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Victrex PLC
Description: enhanced ductility. Chemically resistant to aggressive environments, suitable for sterilization for medical and food contact applications.
- Deflection Temperature (@ 264 psi, 1.8 MPa): 152 F
- Thermal Conductivity: 0.32 W/m-K
- Tensile Strength (Break): 95 psi
- Tensile Modulus: 3.6 ksi
-
Supplier: Eastman Chemical Company
Description: DuraStar™ Polymer MN621 has been tested for FDA/ISO 10993 and USP Class VI Biological Evaluation testing after Gamma and EtO sterilization. It contains a mold release to improve ejection. It processes easily and requires minimal drying time. It has superior toughness, high clarity and
- Deflection Temperature (@ 264 psi, 1.8 MPa): 149 F
- Tensile Strength (Break): 7,686.95248593144 psi
- Elongation: 5 %
- Industry: Medical / Food (FDA)
-
Supplier: Eastman Chemical Company
Description: Durastar™ Polymer MN611 has been tested for FDA/ISO 10993 and USP Class VI Biological Evaluation testing after Gamma and EtO sterilization. It contains a mold release to improve ejection. It has excellent appearance and is nearly water-clear. Its most outstanding features are
- Deflection Temperature (@ 264 psi, 1.8 MPa): 149 F
- Tensile Strength (Break): 7,396.87880721705 psi
- Elongation: 5 %
- Industry: Medical / Food (FDA)
-
-
Supplier: Eastman Chemical Company
Description: DuraStar™ Polymer MN631 has been tested for FDA/ISO 10993 and USP Class VI Biological Evaluation testing after Gamma and EtO sterilization. It contains a mold release. It has excellent appearance and is nearly water-clear. Its most outstanding features are toughness, chemical
- Deflection Temperature (@ 264 psi, 1.8 MPa): 150.8 F
- Tensile Strength (Break): 6,236.58409235947 psi
- Elongation: 5 %
- Industry: Medical / Food (FDA)
-
Supplier: SCHOTT AG
Description: prefillable syringes are available from 1 ml to 50 ml. SCHOTT TopPac® syringes show excellent barrier properties, no ion or heavy metal release, and a lower particle level than glass. The high moisture barrier enables the long-term storage of drugs – even in small containers. Terminal
-
Supplier: ASTM International
Description: of surgical or dental devices. The PEEK polymer in the scope of this specification is a pure semicrystalline homopolymer consisting of phenylene rings connected by ether (E) and carbonyl (or ketone, K) groups along the polymer chain. Its polymeric structure is defined by the repeating
-
Supplier: ASTM International
Description: This specification covers virgin polyetherketoneketone (PEKK) polymer resin as supplied by a vendor (for example, in pellets, powder, and fabricated forms). It provides requirements and associated test methods for these thermoplastics when they are to be used in the manufacture of
-
Supplier: ASTM International
Description: properties of fabricated forms of these polymers should be evaluated using test methods that are appropriate to ensure safety and efficacy as agreed upon by the vendor, purchaser, and regulating bodies. 1.3 The properties included in this specification are those applicable for PAEK
-
Supplier: ASTM International
Description: PDS as it is the polymer of composition of PDS suture (Ethicon, Inc.), representing an early and widely used application of polydioxanone polymer. 1.3 This specification covers virgin polydioxanone resins able to be fully solvated at 30 °C by fluorinated solvents such as
-
Autoclaves and Sterilizers - Saniclave 50 Top Loading Benchtop Autoclave, 8L, 120 VAC -- GO-10776-01Supplier: Cole-Parmer
Description: sterilizer effortless to use. Durable construction with a thermally protective polymer exterior and corrosion-resistant stainless steel interior eliminate burn risk and provides easy-to-clean convenience. Additional features include a low water and under/over temperature alarms, ensuring
- Capacity: 0.27999999999999997 cubic feet
- Application: Laboratory
-
Supplier: Cole-Parmer
Description: • Dry mode to sterilize wrapped or unwrappd instruments • Simple and efficient horizontal loading • Simple one-button automatic operation starts the fast 30-minute sterilization cycle • Compact enough to sit on your benchtop Lightweight, portable yet robust steam autoclave is perfect for all
- Capacity: 0.36999999999999994 cubic feet
- Application: Laboratory
-
Description: The cleanliness of Ethylene Oxide (EtO) typically varies from supplier to supplier and from delivery to delivery. In addition, EtO inherently polymerizes, causing valves to clog and regulators to malfunction. Filtering EtO at the point of use assures the delivery of clean EtO to the sterilizers,
- Maximum Pressure: 250 psi
- Application / Industry: Medical
- Features: Other
- Housing Material: Steel - Stainless
-
Supplier: Teknor Apex Company
Description: Material Status Commercial: Active Availability Asia Pacific Features Ethylene Oxide Sterilizable Non-Phthalate Plasticizer Radiation Sterilizable Uses Medical/Healthcare Applications Forms Pellets Processing Method Injection Molding
- Tensile Strength (Break): 4,270 psi
- Industry: Medical / Food (FDA)
- Type: Molding Resin, Thermoplastic
- Form / Shape: Pellets
-
Supplier: Teknor Apex Company
Description: Material Status Commercial: Active Availability Asia Pacific Features Ethylene Oxide Sterilizable Uses Medical/Healthcare Applications Forms Granules
- Tensile Strength (Break): 1,710 psi
- Industry: Medical / Food (FDA)
- Form / Shape: Pellets
- Chemical System: PolyVinyl Chloride (PVC)
-
Supplier: Parco Scientific Company
Description: thick blended polymer, autoclavable to 138°C (280°F) and feature a sterilization indicator patch that darkens when exposed to steam sterilization. p>
- Volume Capacity: 10 to 12 gallons
- Length: 35.039389 inch
- Width / Diameter: 25.196864 inch
- Container Type: Bag / Sack
-
Supplier: Sartorius Lab Instruments GmbH & Co. KG
Description: PESU polyethersulfone membranes are membrane polymers that are well established in the biotechnological and pharmaceutical industries. The PESU membrane is a stable polymer that features a broad pH and temperature range. Its wide temperature range makes it possible to sterilize some of
- Pressure: 58.01508 psi
- Operating Temperature: 122 F
- Configuration: Filter Element Only
- Sample Type: Liquid
-
Supplier: Electro Optical Components, Inc.
Description: Sterilizable ATR Fiber Probe is a new product of art photonics’ FlexiSpec® product line. This ATR Probes are produced with any type of ATR element and for any type of FTIR spectrometers. Unique Shaft-in-Shaft design enables use of Flexispec® ATR Probe in Bioprocess where sterilization is
- Wavelength: 1,500 to 17,000 nm
- Bending Radius: 130 mm
- Operating Temperature: -150 to 140 C
- Cable Type: Duplex
-
Supplier: Matexcel
Description: Storage: Dark, Dry, Room temperature Usage: 1.The recommended final concentration is 0.1-0.5%. Dissove temperation is 40-60℃. The solution can be sterilized with a 0.22um filter. 2.It is recommended to use this solution for immediate use 3.LAP crosslinks within the visible light spectrum of 365-405
-
Supplier: Ensinger North America
Description: Offering a level of performance above polysulfones, Ensinger's industrial grade TECASON P has increased temperature, impact and chemical resistance properties, as well as excellent resistance to repeated steam sterilization (autoclave) cycles. Main Features: High strength High thermal and
- Deflection Temperature (@ 264 psi, 1.8 MPa): 405 F
- Thermal Conductivity: 0.250956546 W/m-K
- Coeff. of Thermal Expansion (CTE): 30.999999999999996 µin/in-F
- Tensile Strength (Break): 11,500 psi
-
Description: Features Soft and conformable for maximum versatility and patient comfort High tack adhesive bonds well to various materials Stable to ETO and gamma sterilization Good dimensional stability and lay flat Applications Electrode manufacturing including ECG, EKG, TENS, and AED defibrillator pads
- Thickness: 0.0388 inches
- Peel Strength / Adhesion: 4.6875 lbs/in
- Temperature Resistance: 15.555555555555555 to 26.666666666666664 C
- Adhesive: Acrylic
-
Supplier: Grayline, Inc.
Description: Grayline medical tubing is available in a variety of polymer materials and constructions, including phthalate-free and DEHP-free medical tubing. Various Grayline medical tubing products are designed to be sterilized using Gamma radiation, ETO (ethylene oxide), or autoclave processes.
- Temperature Range: -58 to 140 F
- Color / Clarity: Clear, Multi-colored
- Application: Medical / Pharmaceutical
- Features: PVC
-
Supplier: Grayline, Inc.
Description: Grayline medical tubing is available in a variety of polymer materials and constructions, including phthalate-free and DEHP-free medical tubing. Various Grayline medical tubing products are designed to be sterilized using Gamma radiation, ETO (ethylene oxide), or autoclave processes.
- Temperature Range: -99.4 to 399.2 F
- Application: Medical / Pharmaceutical
- Color / Clarity: Multi-colored, Translucent
- Type: Plastic Tubing
-
Supplier: Grayline, Inc.
Description: Grayline medical tubing is available in a variety of polymer materials and constructions, including phthalate-free and DEHP-free medical tubing. Various Grayline medical tubing products are designed to be sterilized using Gamma radiation, ETO (ethylene oxide), or autoclave processes.
- Temperature Range: -40 to 176 F
- Color / Clarity: Clear, Multi-colored
- Application: Medical / Pharmaceutical
- Type: Plastic Tubing
-
Supplier: Malema Sensors
Description: Covol volumetric counter is ideal meter for viscous fluids such as oils, waxes and polymers. The sensor is constructed in SS-316, PVC, PP and PTFE material options to suit corrosive applications. It can be easily cleaned and sterilized. Features Viscosity up to 120,000 mPa.s It will work in
- Media Temperature Range: -40 to 302 F
- Liquid Volumetric Flow Rate: 0.044 to 264.17205234 GPM
- Electrical Output: Analog Current
- End Fittings: Flanged, Threaded
-
Supplier: Eastman Chemical Company
Description: Eastar™ Copolyester MN021 Natural has been tested for FDA/ISO 10993 and USP Class VI Biological Evaluation testing after Gamma and EtO sterilization. It is a thermoplastic condensation copolymer produced by a continuous melt-phase polymerization process followed by a solid-state
- Deflection Temperature (@ 264 psi, 1.8 MPa): 149 F
- Tensile Strength (Break): 3,625.92098392993 psi
- Industry: Medical / Food (FDA)
- Chemical System: Polyester (PET, PBT)
-
Supplier: Master Bond, Inc.
Description: plastics is excellent. The cured system is a superb electrical insulator. The color of Part A is clear and part B is amber. Master Bond Polymer System EP45HTMed is widely used in the manufacturing of medical devices where resistance to repeated sterilization is required. The cured
- Viscosity: 50,000 to 60,000 cP
- Use Temperature: -80 to 500 F
- Tensile Strength (Break): 12,400 psi
- Industry: Aerospace, Automotive, Electrical Power / HV, Electronics, Marine, Medical / Food (Sanitary / FDA), OEM / Industrial, Semiconductors / IC Packaging, Tooling / Mold Material
-
Supplier: Matexcel
Description: LAP Photoinitiator (lithium phenyl-2,4,6-trimethylbenzoylphosphinate or LAP) is designed to cross-link photocurable hydrogels and bioinks with cells photocuring module. The key to printing with your Allevi bioprinter. Storage: Dark, Dry, Room temperature Usage: 1.The recommended final concentration
-
Supplier: MCG - Performance Polymers Division
Description: TECHNOLOGIES ZELAS™ polymers product range is comprised of 4 groups covering a wide range of properties, designed for film, tube and injected components for medical applications: R-TPO: Reactor TPO for film manufacturing or injection molding TPE: Modified elastomer with rubber/PVC like
- Features: Elastomer / Rubber, Thermoplastic / TPE
- Type: Extrusion Grade Resin, Film Grade Resin, Molding Resin
- Industry: Medical / Food (FDA)
-
Supplier: Qosina Corp.
Description: Qosina offers an extensive line of syringes in a variety of volumes and configurations that are in stock and ready for immediate delivery. Sold by the box, Qosina pn#C1150 is COP (Cyclo Olefin Polymer) syringe that feature a bold, blue handle and fixed male luer lock connection. COP syringes
- Syringe Volume: 10 cc
- Features: Other
- Configuration: Syringe
-
Supplier: CSA Group
Description: ISO 6877:2006 specifies the dimensions and compositional requirements for prefabricated metal or polymeric points or cones suitable for use in the obturation of the dental root-canal, but not for support of a coronal restoration. It also specifies numerical systems and a colour coding system for
-
Description: ISO 6877:2006 specifies the dimensions and compositional requirements for prefabricated metal or polymeric points or cones suitable for use in the obturation of the dental root-canal, but not for support of a coronal restoration. It also specifies numerical systems and a colour coding system for
-
Supplier: Fluoro-Plastics, Inc.
Description: Film is available in thicknesses from one mil (.001") up to 20 mils (.020"). Because Fluoro-Plastics uses the most modern skiving technology in the world, interim thicknesses are available; widths from ½" to 60 inches are available in long lengths. Thin film is a versatile, unsupported hydrophobic
- Dielectric Strength: 19,685,039.3700787 V/m
- Features: Abrasion / Scratch Resistant, Dielectric / Insulating
- Backing: Fluoropolymer, Plastic / Polymer
-
Supplier: Ensinger North America
Description: Celcon M-25 (TECAFORM MT) yellow is Ensinger's specially formulated acetal, suitable for medical applications. The POM-C material is resistant to multiple cleaning and disinfection agents, and to a number of solvents. It can be steam sterilized by medical industry's usual methods, and will maintain
- Deflection Temperature (@ 264 psi, 1.8 MPa): 230 F
- Coeff. of Thermal Expansion (CTE): 55 to 550,000,000,000 µin/in-F
- Tensile Strength (Break): 10,000 psi
- Tensile Modulus: 390 ksi
-
Supplier: Cambridge Polymer Group, Inc.
Description: device cleanliness studies, failure analysis, sterilization procedures, oxygen content, Vitamin E characterization Mechanical Analysis Dynamic mechanical analysis (DMA), tensile testing, compression testing, creep testing For a partial list of ASTM standards performed by Cambridge
- Standards (Test / Certify To): ASTM, NIST, OEM Specific
- Materials: Adhesives / Sealants, Coatings, Cosmetics (Creams, Sunblocks, etc.), Plastic / Rubber, Polymers / Organics, Powders, Textiles, Wafers / Surfaces
- Industry: Aerospace / Aviation, Automotive, Food / Beverage, Health Care / Medical, Legal / Forensics, Marine, Packaging, Pharmaceutical / Biotech
- Capabilities: Assays / Quantitative, Cleanliness Monitoring / Testing, Deformulation / Reverse Engineering, Failure Analysis, Quality / Purity (Contamination - Alloys, Polymers, etc.), Report Preparation, Standards Testing / Certification, Umpire Testing
Find Suppliers by Category Top
Featured Products Top
-
Gamma radiation is a common sterilization technique for medical products. Generally, polypropylene (PP) resins exposed to gamma or other high-energy radiation sources lose physical and mechanical properties after exposure. Vistamaxx performance polymers can enhance the flexibility and toughness of polymers, improving the performance of PP resins after gamma sterilization. (read more)
Browse Polymers and Plastic Resins Datasheets for ExxonMobil - Polypropylene Products -
Engineered as a PFAS-free1 alternative to film-cast PTFE, PFX Flex™ Sub-Lite-Wall™ is a next-gen catheter liner that delivers proven lubricity, enhanced bond strength, and expanded sterilization options. (read more)
Browse Medical Tubing Datasheets for Zeus -
ESPEC North America Inc | Qualmark Products and Services
HAST - Highly Accelerated Stress Test Chambers
insights, mitigating costly failures and enabling rapid design iteration. Medical Devices & Sterile Equipment Devices exposed to autoclaving, steam sterilization, or high humidity environments, like surgical instruments, implants, and diagnostic sensors- must withstand repeated (read more)
Browse Environmental Test Chambers and Rooms Datasheets for ESPEC North America Inc | Qualmark Products and Services -
encapsulation applications. EP21LSCL-2Med is specially formulated to have minimal non-yellowing tendencies. This system features a high glass transition temperature (Tg), good resistance to steam and water, liquid sterilants and EtO sterilization. The service temperature range is from -60°F to (read more)
Browse Industrial Adhesives Datasheets for Master Bond, Inc. -
. Durability of plastic composites allows them to withstand increased friction and heavy loads better than other types of material, including metals. Easier to clean and sterilize than metal, plastic composites play (read more)
Browse Plastic Molding Services Datasheets for Osborne Industries, Inc. -
temperature exposure or experience Clean-in-Place (CIP), Steam-in-Place (SIP) and Stage II sterilization. Perlast® perfluoroelastomer medical seals provide the ultimate in thermal and (read more)
Browse O-rings Datasheets for Precision Polymer Engineering Ltd. -
Isothermal chambers for controlled environments Cleanroom sealing solutions Sliding or quick-locking doors for autoclaves, sterilizers, dryers, and reactors Centrifugal filters (e.g., access doors and drainage hoppers) Industrial (read more)
Browse Dynamic Seals Datasheets for Technetics Group -
environments Cleanroom sealing solutions Sliding or quick-locking doors for autoclaves, sterilizers, dryers, and reactors Centrifugal filters (e.g., access doors and drainage hoppers) Industrial Applications Cofferdams for (read more)
Browse Inflatable Seals Datasheets for Technetics Group
Conduct Research Top
-
Sterilisation of Polymer Healthcare Products
Sterilisation of Polymer Healthcare Products. With the many possible ways to sterilize healthcare products, and new techniques being developed all the time, this book identifies the variety of factors that must be taken into account and offers a thorough description of the conventional methods.
-
Autoclaving Resistance of Medical Adhesives
Resistance to steam sterilization is an important consideration for the selection of polymeric adhesives, sealants and potting compounds for use in medical applications. Autoclaving is one of the most rigorous and widely employed sterilization methods for medical devices. With this in mind, Master
-
Application Development in the Medical Industry
for a medical device that includes the working environment the device will be used in. This is the case for instance when considering magnetic resonance (MR) assisted surgery. There are also questions as to potential changes in the polymer when it is exposed to traditional and new sterilization methods
-
Which to Choose-Stainless Steel or Single Use Technology (SUT)?
high-performance polymers for disposable components that have been sterilized using gamma irradiation. Over time, companies have sifted through the pros and cons of both types of technologies, SUTs and stainless steel, to determine the best options for business operations.
-
How to Size an Indirect Paddle Thermal Processor for Drying
a process mass. A paddle thermal processor can be used to dry, heat, sterilize, cool, react, torrefy, melt, pasteurize, strip solvents, calcine, roast, cook, or crystallize a wide variety of materials such as chemicals, pharmaceuticals, biosolids, food, waste, minerals, polymers, metals, and more.
-
Low-Risk Lyophilization
By Brian Bucur, Associate Director, Lyophilization & Sterilization and Timothy Smith, Director, Product & Process Development - Ben Venue Laboratories, Inc. An important consideration for the development stage of a lyophilized product is to consider selection of a stopper that has a coating or film
-
A Closer Look at Form-Fill-Seal Technology
technologies to minimize operator intervention and contamination risk in the filling and packaging of liquid parenteral drugs. One of these technologies is form-fill-seal (FFS), in which a polymeric material is formed and sealed inline to a container of choice, while the container is being filled. FFS offers
More Information Top
-
Handbook on Advanced Design and Manufacturing Technologies for Biomedical Devices
In some cases the method can produce a certain oxidation of the polymers sterilised by this method, as has been recorded in some “UHMWPE” implants.
-
Human pathogens, nosocomial infections, heat-sensitive textile implants, and an innovative approach to deal with them
Accordingly, dense gaseous, liquid or supercritical carbon dioxide (scCO2) (T [ 31°C, P [ 74 bar) is generally suitable, but has not been investi- gated in detail for (bio) polymer sterilization yet [36].
-
Methods for the Preparation and Manufacture of Polymeric Nanoparticles
Gamma irradiation is another effective method of polymer sterilization accepted by European Pharmacopeia which can be applied on heat-sensitive materials.
-
Aeration of ethylene oxide-sterilized polymers.
The ethylene oxide (EO) content of 17 polymers sterilized with 100% EO under conditions normally used in practice was determined as a function of aeration time, and for some polymers also as a function of sample thickness.
-
Cellular Transplantation-Based Evolving Treatment Options in Spinal Cord Injury
Although the synthetic polymers could be sterilized quite safely, there is some concern associated with the reliability of the natural polymer sterilization .
-
Polyethylene terephthalate membrane grafted with peptidomimetics: endothelial cell compatibility and retention under shear stress.
Cells were lost on non-grafted PET whereas cells on grafted polymers sterilized by γ-ray irradiation withstood forces with no significant difference in focal contacts.
-
Resorbable and Nonresorbable Hydroxyapatite Granules as Bone Graft Substitutes in Rabbit Cortical Defects
Immediately prior to surgery, the implants were placed in polymer sterilizing bags and were steam ster- ilized (prevacuum cycle, 120°C,20 min).
-
The Chemistry of Medical and Dental Materials
The effects of polymer cross – linking to enhance wear resistance, biological effects of wear particles and polymer debris, methacrylate monomer cytotoxicity as well as methods of polymer sterilization are also considered.
-
Studies of the healing of bone grafts, and the incorporation of titanium implants in grafted bone: an experimental animal model
Immediately before surgery, the implants were placed in polymer sterilizing bags and steam sterilized.
Indicates content that may require registration and/or purchase.