Current Transformers - (399 companies)Current transformers are used to step down current in a very predictable fashion with respect to current and phase. They are generally used as inputs to current instruments. Current transformers measure power flow and provide electrical inputs...Type / Applications -
Current Sense Transformers - (123 companies)Current sense transformers are used to detect and measure current. There are two basic types of products: switch-mode transformers for power conversion applications, and precision-measurement transformers for instrumentation applications. Current... -
Transformers - (2112 companies)...applications for signal isolation and impedance matching. Current sense transformers detect and measure current. Some of these products are designed to precisely measure current in instrumentation applications, while others are used in switch-mode...
-
Power Transformers - (1025 companies)...to potentially remote locations, they generate high voltages to transmit the current to these areas. Multiple power transformers must be incorporated into to the system in order to gradually step down the voltage for safe residential use. Transformers may... -
Instrument Transformers - (372 companies)Instrument transformers are used to step-down current or voltage to measurable values. They provide standardized, useable levels of current or voltage in a variety of power monitoring and measurement applications. There are two basic types... -
RF Transformers - (127 companies)DC current. DCR. operating temperature. The operating frequency is the frequency range for which the transformer will meet all guaranteed specifications. Three dB bandwidth is the frequency range for over which the insertion loss is less than 3 dB...
-
Signal Transformers - (433 companies)...step-down, isolating, or impedance matching component in electronic devices. Power transformers, which carry current, are generally not suited for use as signal transformers and vice versa. Signal transformers are used in typical electronics applications...
-
Electronic Transformers - (35 companies)...of the load to the PFN, they maximize power-transfer efficiency. Rectifier transformers produce a DC voltage or current and are used to drive a diode or thyristor. RF transformers are used for impedance matching over the RF spectrum. Switch mode...
-
Distribution Transformers - (88 companies)Distribution transformers are pole-type transformers that supply relatively small amounts of power to residences. They are used at the end of an electrical utility 's delivery system. Distribution transformers are pole-type transformers that supply...
-
Transformer Winding Services - (151 companies)...buck boost transformers, control transformers, current transformers, distribution transformers, ferroresonant transformers, filament transformers, flyback transformers, high frequency transformers, isolation transformers, laminated transformers...
Product News
-
Triad Magnetics
Current Transformers Triad Magnetics' pioneering design process promotes innovation. There are thousands of Triad Magnetics designs providing application solutions throughout the world, from data processing to telecommunications to power conversion. Our engineers are experienced in all styles, Thru-hole, SMD, Leaded, Planar, Toroidal, Potted, Flat Wire, Litz Wire, Bobbin Wound, Edge Wound, Section Wound, Low Frequency, High Frequency, Low Voltage and High Voltage. If you need it, we can design and manufacture it. (read more) -
Majestic Transformer Co.
What is the transformer inrush current Transformer inrush current is the temporary surge of current that occurs when a transformer is first switched on. It can be several times higher than the normal operating current, even when the transformer is working correctly. (read more)Browse Three Phase Transformers Datasheets for Majestic Transformer Co. -
Triad Magnetics
Looking for Current Sense Transformers Current sense transformers "transform " AC electrical currents from larger-current values into smaller currents that are better suited for instruments, protective relays, and control circuits. This is achieved by developing a current in the secondary winding that is proportional to that of the primary. The isolation aspect of the transformer keeps the high voltage of the primary system separate from the instrument, safety circuit, or control circuit on the other side, thereby protecting them... (read more)Browse Current Sense Transformers Datasheets for Triad Magnetics -
Triad Magnetics
Custom Current Sense Transformers Triad Magnetics' pioneering design process promotes innovation. There are thousands of Triad Magnetics designs providing application solutions throughout the world, from data processing to telecommunications to power conversion. Our engineers are experienced in all styles, Thru-hole, SMD, Leaded, Planar, Toroidal, Potted, Flat Wire, Litz Wire, Bobbin Wound, Edge Wound, Section Wound, Low Frequency, High Frequency, Low Voltage and High Voltage. If you need it, we can design and manufacture it. (read more)Browse Current Sense Transformers Datasheets for Triad Magnetics -
Coilcraft, Inc.
Current Sense Transformers Sensed current up to 40 Amps. For use between 400 Hz to 1 MHz. Very low primary resistance. AEC-Q200 Grade 1 ( -40°C to +125°C). Meets Reinforced Insulation per UL 60950-1. 4000 Vrms, one minute isolation (hipot) winding to winding. RoHS-compliant. 260°C compatible. Tin-silver-copper over tin over copper over steel (pins 1 - 3); Tin-silver-copper over tin over nickel over copper (pins 4 - 5) terminations (read more) -
Triad Magnetics
Designing Effective Current Sense Transformers Design Considerations for Current Sense Transformers. Current sense transformers are instrument transformers designed to detect (i.e., sense) electrical current and convert (i.e., transform) it into a more usable and safe form for the connected device(s). They perform this function by measuring the current flow in the primary winding and producing a proportional current in the secondary winding, enabling the reduction of high-voltage current in the primary winding to a lower value... (read more)Browse Current Sense Transformers Datasheets for Triad Magnetics -
Triad Magnetics
Current Sense Transformers from Triad Magnetics Current Sense Transformers. As their name implies, current sense transformers "sense, " or detect, an electrical current (typically AC), accurately measure it based on Ohm 's Law, and/or "transform " it into more usable voltages for various instruments and devices. When only current sensing is needed, the primary winding is a conductor integral to the application that passes directly through the resistor. If the electrical current needs to be transformed, the current sense transformer may have... (read more)Browse Current Sense Transformers Datasheets for Triad Magnetics -
WAGO
Split-Core Current Transfers WAGO's compact split-core current transformers are ideal for retrofitting existing systems. They are perfect for applications in which the current path must not be disrupted. The transformer's accuracy permits extremely precise current measurements. The split-core current transformers are capable of supplying the specified rated power at the end of the secondary cable. All transformers are supplied with color-coded cables. Two UV-resistant cable ties are also included for secure and easy (read more)Browse Signal Conditioners Datasheets for WAGO -
Majestic Transformer Co.
Guide to Transformer kVA Ratings Guide to Transformer kVA Ratings: Choose the Right One for Your Needs. Understanding the rating of a transformer is essential when choosing a device that handles both voltage and current effectively. Whether you 're working with a high insulation class-rated transformer for a critical industrial application or simply need a reliable unit for your home, knowing how transformers are rated is the first step in ensuring your equipment can handle the required power capacity. Keep Reading (read more)Browse Transformers Datasheets for Majestic Transformer Co. -
Majestic Transformer Co.
Low Inrush Transformers We were approached by a client who was experiencing problems with inrush start up currents on conventional transformers. On long cable runs these high inrush currents (typically 10 - 15 times the full load current of the transformer can be experienced) were causing excessive cable voltage drops and causing other equipment on the supply to drop out. After some discussion with the client, it was decided that the options of offering some form of inrush suppression were not suitable... (read more)Browse Transformers Datasheets for Majestic Transformer Co.
-
States > New York > State > Register > 2011 > [2011 NY Register 629] 06/29/2011
Whether to Permit the Use of RITZ Instrument Grade Current and Voltage Transformers .
-
Simulation of power stations and wärmetechnischen installations
… 75 Finite- Differenzen- method, 171, 578 Finite- element-method, 173 Galerkin methods, 174 Ritz'sches method, 174 Finite … … two-phase flow, 118 gas phase, 128 gas radiations 503, 603 Gaus, 585 compensation account, 586 normal distribution, 254 gas turbine, 587, 594 fan 200, 505 countercurrent heat transmitters 603, 507 generator, speed … … grid, 167, 198 same Joule heat transmitters, 507 systems …
-
Spotlight on Modern Transformer Design
1992) Numerical calculation of 3-D transient eddy current field and short circuit electromagnetic force in large transformers . IEEE Transactions on Magnetics 28(2):1418–1421 Ritz W .
-
2012 T and D Technical Program [Technical Program]
Leibniz Universität Hannover C. REESE, Leibniz Universität Hannover L. HOFMANN, Leibniz Universität Hannover H. DÄUMLING, Ritz Instrument Transformers GmbH 2012TD0416 Application of an Optical Current Transformer for Cable Head Station of Hokkaido-Honshu HVDC LinkApplication of …
-
3-D non-linear eddy current analysis using the time-periodic finite element method
By solving simultaneously the Rayleigh- Ritz matrix equations at respective steps in half a period taking into … AN EXAMPLE OF APPLICATION The currents in the primary and the secondary windings of a loaded transformer shown in Fig.2 are analyzed.
-
The torque on cold-rolled Trafo sheet metal discs in the strong magnetic field
The erw / ihnte contribution of the voltage energy becomes vernach-1 / issigt because of following ~ of berlegungen in this work: Becomes through the insulating layer of the transformer sheet metals by a … … to reduce abnormal eddy current losses. … and reduced k6nnen through a refinement of the dome / inenstruktur by means of tension or scratches .
-
Examples of ferroresonance in a high voltage power system
However, the IT is designed to handle twice rated current for up to 30 seconds which is … Ritz instrument transformers recommend installing an inductor in parallel with a resistor.
-
Harmonic distortion in power stations due to ferroresonance
IEEE Standard for AC High-Voltage Generator Circuit Breakers Rated on a Symmetrical Current Basis - Amendment I … Instrument transformers - Part 3: Additional requirements for inductive voltage transformers, IEC 61869-3, Edition 1.0, [4] "Damping Inductance Device DE6 data sheet", Ritz Messwandler GmbH, Germany, .
-
Frequency Responses of MV voltage transformers in the range of 50 Hz to 10 kHz
… are with Institute of Electrical Power Systems and High Voltage Engineering, Technische Universitaet Dresden, 0- 01062 Dresden, Germany (e-mail: jan.meyer@tu-dresden.de) M. Elst is with RITZ Instrument Transformers GmbH, location Dresden, Bergener … … mail: mi chael.elst@ ritz -intemational.com Harmonic currents cause harmonic voltages at the network harmonic impedance.
-
ENERGYCON2012 - ICT for Energy
Christoph Buchhagen (Leibniz Universität Hannover, Germany); Constantin Reese (Leibniz Universität Hannover, Germany); Lutz Hofmann (Leibniz Universität Hannover, Germany); Holger Däumling ( RITZ Instrument Transformers GmbH, Germany Metrological characterization of a current sensor for Smart Grids .