Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Newark, An Avnet Company
Description: COMMUNICATION MODULE; MODBUS RTU; RJ45; COMMUNICATION CAPABILITY
-
Supplier: Willowglen Systems Inc.
Description: The Willowglen FloLink™ Micro RTU provides a cellular communication link for various process sensors. With its hazardous area certification and low power consumption, the FloLink™ Micro RTU is the perfect choice for communicating with remote locations.
- Number of Serial Ports: 2
- Features: Battery Back Up
- Communications: Serial - RS-232 / 422 / 485
-
Supplier: Gefran
Description: The GFX4-MOD module can be installed inside GFX4/GFXTERMO4 products and expands communication by means of the Modvus RTU protocol. The module has two communication channels: • the first channel is a serial port with Modbus RTU protocol, and connects 32 GFX4/GFXTERMO4
-
-
Supplier: Shenzhen Wlink Technology Co., Limited
Description: WLINK rugged RT600 series RTU (Remote Terminal Unit) is a cellular communication device installed at a remote location that collect data, codes the data into a format that is transmittable and transmit the data back to a central station or master, it's been developed especially for
- Number of Serial Ports: 2
- Number of Analog I/O Points: 2
- Number of Digital I/O Points: 2
- Features: Other
-
Supplier: Sichuan Odot Automation System Co., Ltd.
Description: CN-8011 Modbus-RTU Bus Adapter Module Overview CN-8011 Modbus-RTU network adapter supports standard Modbus-RTU communication, it supports function code of 01/02/03/04/05/06/15/16/23, and this device could monitor the IO module communication state in real time.
-
Supplier: Gefran
Description: The GFX4-CAN module can be installed inside GFX4/GFXTERMO4 products and expands communication by means of the CANopen protocol. The module has two communication channels: • the first channel is a serial port with Modbus RTU protocol, and lets you connect a maximum of four
-
Network Cards and Network Controllers - Intergrated Control Modbus-RTU COMM Board IO Card -- BN-8011Supplier: Sichuan Odot Automation System Co., Ltd.
Description: The BN-8011 Modbus-RTU network adapter supports standard Modbus-RTU communication 01/02/03/04/05/06/15/16/23 function code. This device could monitor the IO module communication state in real time.
- Data Rate: 2.4 to 115.2 kbps
- Operating Temperature: -30 to 75 C
- Features: Other
-
Supplier: Pepperl+Fuchs SE
Description: Interface between the I/O modules and the PCS/PLC Com unit for 80 analog or 184 digital channels Installation in Zone 2, Div. 2 or safe area Communication via MODBUS RTU HART communication via service bus Configuration via FDT 1.2 DTM Non-volatile memory for configuration and
-
Supplier: Gefran
Description: The GFX4-DEV module can be installed inside GFX4/GFXTERMO4 products and expands communication by means of the DeviceNet protocol. The module has two communication channels: • the first channel is a serial port with Modbus RTU protocol, and lets you connect a maximum of four
-
Supplier: Gefran
Description: The GFX4-ETH module can be installed inside GFX4/GFXTERMO4 products and expands communication by means of the Modbus/TCP protocol. The module has two communication channels: • the first channel is a serial port with Modbus RTU protocol, and connects a maximum of four
-
Supplier: Delta Electronics (Americas)
Description: ‧A PROFIBUS DP remote communication module ‧Supports PROFIBUS DPV0 cyclic data transmission ‧Auto-detects baudrate, diagnosis ‧Max. baudrate: 12M bps ‧Connectable to 8 DVP-S series analog I/O modules ‧Connectable to 256 points of digital I/O modules ‧RS-485 port is connectable to max. 16
- Number of Ports: 3 #
- Network Equipment: Gateway
- Area Network Type: Local Area Network (LAN)
- Form Factor: Rack Mount
-
Supplier: DigiKey
Description: Serial to Serial Adapter Card RS-485
- Serial Protocol: RS485
- Features: Serial/Device Server
-
Supplier: Fieldbus International AS
Description: DIN rail mounted gateway for connecting Modbus RTU instruments to a HART network General information: The T310 is a three-wire DIN rail mounted module for interfacing Modbus transmitters to a HART network. The T310 is a complete transmitter module; it generates a Primary Variable (PV)
-
Supplier: Shenyang Vhandy Technology Co., Ltd.
Description: Application: The serial communication device is connected to CAN-bus; PLC connection CAN-bus; Modbus RTU and CAN communication; CAN-bus and serial bus gateway; Monitor industrial site network data; Beginners learn CAN; CAN industrial automation control system; Collect low-speed
- Operating Temperature: -40 to 185 F
- Features: DC Current, DC Voltage
- Form Factor: DIN Rail
-
Supplier: Advantech
Description: Modbus RTU/TCP to EtherCAT Fieldbus Gateway, Wide Temperature Seamless integrate Modbus RTU/TCP and EtherCAT communication Built-in real time diagnostic to increase highly efficiency of device management Designed for protocol extensibility and adaption Modbus TCP client mode
- Network Equipment: Gateway
-
Supplier: Shenyang Vhandy Technology Co., Ltd.
Description: Modbus TCP, Modbus RTU communication (corresponding to two kinds of style) Ethernet interface is compatible with the SOCKET working mode (TCP Server, TCP Client,UDP, etc.). The upper computer communication GC- series 1008~8012--with digital&analog and special IO modules Please
- Transmission Rate: 115,200 kbps
- Operating Temperature: -40 to 185 F
- Features: DC Voltage Input
-
Supplier: BinMaster, Inc.
Description: dielectric materials down to 1.3. It has 4 -20 mA and Modbus RTU communication options, making it compatible with your HMI or PLC, as well as BinMaster's Binventory LAN-based software program or BinView cloud-based monitoring.
- Measuring Range: 1,200 inch
- Material Temperature Range: 392 F
- Features: Analog Current, Top mount
- Level Measurement Type: Continuous Level
-
Supplier: Apix, Inc.
Description: DESCRIPTION The ISODIN Series DIN Modules feature 8 independent Analog channels and conform to the Industry Standard Modbus RTU Communications Protocol. They are fully isolated with 3000 Vrms between Input, Power, RS-485 ser
- Analog Input Channels: 12 #
- Accuracy: 0.01 % FS
- Common Mode Rejection Ratio: 140 dB
- Operating Temperature: -40 to 185 F
-
Supplier: Fieldbus International AS
Description: The T810 is a built-in board. It supports the Modbus CMOS protocol (with adaptive logical level) for communication with the instrument. The Modbus communication needs to be configured to allow T810 to fetch Device Variables and Device Status from the correct registers within the
-
Supplier: Sichuan Odot Automation System Co., Ltd.
Description: 1.Reliable, compact, easy to expansion IO, can support up to 32 I/O modules. 2. It could be applied to multiple industries and scenarios such as mechanical processing equipment, sewage treatment, textile, non-standard automation, etc. 3. Seamless communication with reliable connection. Modbus
- Maximum Number of Channels: 10
- Operating Temperature: -22 to 158 F
- Program Languages: IEC 61131-3
- Features: Other, Other / Proprietary
-
Supplier: WAGO
Description: Communication module; Modbus RTU; RJ45; communication capability
- Operating Temperature: -13 to 158 F
- Data Acquisition: I/O Module
-
Supplier: Fieldbus International AS
Description: T710 is a complete transmitter module. It allows interfacing up to 4 Modbus instruments. It generates a measured variable including a status variable indicating the quality of the measurement. T710 includes a Modbus master in order to communicate with a Modbus RTU instrument. The module reads
- Network Equipment: Gateway
-
Supplier: Newark, An Avnet Company
Description: MODBUS, RTU/TCP-ETHERCAT GATEWAY, 6PORT; No. of Ethernet Ports:4Ports; No. of Serial Communication Ports:2 Port; Network Speeds:10Mbps, 100Mbps; Port Types:RJ45 x 4, DB9 Male x 2; Gateway Server Mounting:DIN Rail / Wall RoHS Compliant: Yes
-
Supplier: Newark, An Avnet Company
Description: MODBUS, RTU/TCP-PROFINET GATEWAY, 6PORT; No. of Ethernet Ports:4Ports; No. of Serial Communication Ports:2 Port; Network Speeds:10Mbps, 100Mbps; Port Types:RJ45 x 4, DB9 Male x 2; Gateway Server Mounting:DIN Rail / Wall RoHS Compliant: Yes
-
Supplier: Newark, An Avnet Company
Description: DIGITAL INDICATING CONTROLLER, 30 PROGRAMS / 300 SEGMENTS, 8 DIS, 8 DOS, POWER SUPPLY 100 -240 V AC, RS485 COMMUNICATIONS (MODBUS RTU & ASCII, PC-LINK, LADDER,MASTER -SECONDARY, PEER TO PEER, ENGLISH, BLACK/GREY
-
Supplier: Tri-Tronics Company, Inc.
Description: For documentation and other X-PRO XPC models, please see our X-PRO XPC Marketing Page. Technical Features Model Specific Communication Type: RS-485 MODBUS RTU Optical Block: None LED Light Source Red = 660nm Visible red LED light source recommended for sensing transparent/translucent
- Operating Temperature: 32 to 158 F
- Electrical Output: Current
- Features: DC Powered, Photoelectric Sensors
- Interface: Serial
-
Supplier: Tri-Tronics Company, Inc.
Description: For documentation and other X-PRO XPC models, please see our X-PRO XPC Marketing Page. Technical Features Model Specific Communication Type: RS-232 MODBUS RTU Optical Block: None LED Light Source Red = 660nm Visible red LED light source recommended for sensing transparent/translucent
- Operating Temperature: 32 to 158 F
- Electrical Output: Current
- Features: DC Powered, Photoelectric Sensors
- Interface: Serial
-
Supplier: Viconics Technologies Inc.
Description: network systems. Our Network Ready "standalone" versions can be field retrofit with optional communication modules that enable the VT7600F to be integrated into virtually any building automation system as budgets allow or as the building requirements change. No previous building automation
- Interface: Digital Front Panel
- Media: Gas / Air
- Controller Type: HVAC Controller
- Form Factor: Panel / Chassis Mount
-
Supplier: Define Instruments
Description: to your compatible device. The kit contains: 1x USB Bridge Key 1x Interface cable 1x Head-mount adaptor (for head-mount transmitters only) 1x USB extension cable Compatible with: Merlin Zen Datalogger Zen RTU/U and Zen RTU/R ZEN-16 (superseded) Wireless Gateways (including Twin Link
- Agency Approvals: CE Conformity Marks
- Network / Bus: USB
-
Supplier: Advantech
Description: Modbus RTU/TCP to 3-in-1 EtherNet/IP or PROFINET or OPC UA Protocol Gateway, Wide Temperature Seamless integrate Modbus RTU/TCP and EtherNet/IP or PROFINET or OPC UA communication Built-in real time diagnostic to increase high efficiency of device management Designed for
- Form Factor: Ceiling / Wall Mount
- Network Equipment: Gateway
-
Supplier: PR electronics
Description: Application The 4511 detachable display adds Modbus RTU RS-485 serial communications to all current and future 4000/9000 units. The unit converts a wide array of sensors and analog device signals measured by the system 4000 like uni- and bipolar mA and voltage signals, potentiometer,
- Operating Temperature: -4 to 140 F
-
Supplier: Tri-Tronics Company, Inc.
Description: For documentation and other X-PRO XPC models, please see our X-PRO XPC Marketing Page. Technical Features Model Specific Communication Type: RS-232 MODBUS RTU Optical Block: Type R4, Retroreflective Very narrow beam optics designed to sense reflectors or reflective materials at long
- Operating Distance: 216.53555 inch
- Operating Temperature: 32 to 158 F
- Electrical Output: Current
- Features: DC Powered, Photoelectric Sensors
-
Supplier: Tri-Tronics Company, Inc.
Description: For documentation and other X-PRO XPC models, please see our X-PRO XPC Marketing Page. Technical Features Model Specific Communication Type: RS-485 MODBUS RTU Optical Block: Type R4, Retroreflective Very narrow beam optics designed to sense reflectors or reflective materials at long
- Operating Distance: 181.10246 inch
- Operating Temperature: 32 to 158 F
- Electrical Output: Current
- Features: DC Powered, Photoelectric Sensors
-
Supplier: Shenyang Vhandy Technology Co., Ltd.
Description: Modbus TCP, Modbus RTU communication (corresponding to two kinds of style) Ethernet interface is compatible with the SOCKET working mode (TCP Server, TCP Client,UDP, etc.). The upper computer communication GC- series 1008~8012--with digital&analog and special IO modules Please
- Operating Temperature: -40 to 185 F
Find Suppliers by Category Top
Featured Products Top
-
Experience advanced digital measurement with the AcuDew Modbus RTU dewpoint transmitter. The AcuDew Modbus RTU dewpoint transmitter combines SHAW’s proven ultra-high capacitance, aluminium oxide, dewpoint sensing technology with modern digital communication capability. Designed for (read more)
Browse Hygrometers and Humidity Measurement Instruments Datasheets for Shaw Moisture Meters -
with reduced noise and vibration. The newest CVD RS-485 Communication type driver allows for operational and parameter setting directly to the driver via RS-458 (Modbus RTU) communications. This driver also works with our MEXE02 Support Software and allows for programs to be stored and called (read more)
Browse Stepper Motors (rotary) Datasheets for Oriental Motor USA -
Oriental Motor USA Corporation is pleased to announce the launch of the RS-485 Communication Type Driver for the BLS Series Brushless Motors. Designed to meet the growing demands of the Factory Automation (FA) market, this new driver utilizes Modbus (RTU) protocol, enabling seamless data (read more)
Browse Brushless Motors Datasheets for Oriental Motor USA -
software are also available in most configurations. Seamless Integration with Modbus RTU All sensors support Modbus RTU communication, providing streamlined integration, remote configuration, and advanced diagnostics. (read more)
Browse Gas Sensors Datasheets for Dynament -
as the ability to control permanent magnet motors. Modbus RTU communication and generous built-in I/O, including analog, digital (with one 10kHz pulse train input), and relay, are standard. NEMA 1 conduit boxes, DIN rail mounting kits, braking resistors, and more are offered (read more)
Browse AC Motor Drives Datasheets for Automationdirect.com -
functions. Energy Meter: Universal 1-phase and 3-phase energy meter with Modbus RTU/RS485 communication, 1 x digital input, 2 x digital outputs, and measured values for system and energy monitoring. (read more)
Browse Electromechanical Relays Datasheets for Altech Corp. -
. It can be set in degrees Centigrade or Fahrenheit and provided with various data highway communication capabilities. (Standard communication port RS485-MODBUS RTU protocol) These characteristics make the Terminator ECM the most versatile and affordable local to application (or ‘pipe (read more)
Browse Temperature Controllers Datasheets for Thermon, Inc -
adjustment, diagnostics, and data logging through dedicated PC software. Manual calibration can also be performed without digital communications, offering additional flexibility during installation and field servicing. The platform supports Modbus RTU communication for straightforward (read more)
Browse Gas Sensors Datasheets for Dynament -
requirements. For seamless integration into control and monitoring systems, the platform supports Modbus RTU communication, enabling efficient configuration, diagnostics, and data exchange. Suitable for oil and gas operations, industrial safety systems, mining equipment, process control (read more)
Browse Gas Sensors Datasheets for Dynament -
The SmartTrax Remote Telemetry Unit (RTU) provides battery operated wireless telemetry of flow and sensor data. It can be used with mechanical or digital registers and can be mounted remotely for best positioning to transmit the signal. The unit uses cellular radio communication and features (read more)
Browse Flow Meters Datasheets for McCrometer, Inc.
Conduct Research Top
-
RTUs-A New Type of Controller with Versatile Programmability
Programmability empowers system integrators to build their own programs for certain demands, making it an indispensable feature for a controller in today's remote monitoring and control applications. A Remote Terminal Unit (RTU) features more versatile programmability and broader communication
-
Cloud Connectivity for Industrial IoT Applications
A hardware communication hub such as an RTU or a gateway is often the best tool to collect, format, and forward industrial automation system big data to the cloud.
-
Quantum Case Study
For this specific project, a municipality operates an 11-mile pipeline, which crosses two other cities to deliver water to a treatment facility. Four pump station RTU cabinets sit along the pipeline, controlling and monitoring the flow of water. Inconsistent and unreliable communication made
More Information Top
-
ISA SCADA - SCADA: Supervisory Control and Data Acquisition
Field/ RTU Communications ...
-
Cryptographic Key Management for SCADA System: An Architectural Framework
RTU to RTU communication is not possible in this mechanism.
-
IEEE Standard for SCADA and Automation Systems
97 C.2 Specify the performance of a master station to RTU communication channel .................................
-
IEEE Standard Definition, Specification, and Analysis of Systems Used for Supervisory Control, Data Acquisition, and Automatic Control
The communication interface portion of figures 2 and 3 are used to interface the RTU communication channels to the master station computer system.
-
IEEE Trial-Use Recommended Practice for Data Communications Between Intelligent Electronic Devices and Remote Terminal Units in a Substation
Description of IED-to- RTU communications needs...........................................................................................6 .
-
Oil and Gas Pipelines: Integrity and Safety Handbook
In this way, if one SCADA server should fail, the RTU communication lines can be swung over to the other SCADA server to continue the essential service of retrieving RTU data.
-
Computer Networks and Information Technologies
Proposed scheme categorizes the communication into three categories as follows A RTU to RTU communication B MTU to RTU communication C RTU to MTU communication .
-
Flow Measurement
Modbus RS 485 RTU communication for direct integration into skids, OEM and pre-assembled plant packages Flowmeters FC410 (Dual tube design) .
-
RTUs slave for supervisory systems [power systems]
The RTU communication sub- system is responsible for interpreting messages from the master and formatting messages to be sent to the mas- ter.
-
Computer Safety, Reliability, and Security
The industrial protocols used are Modbus/TCP for RTU-CC communication, Modbus/RTU for inter-RTUs communication and WirelessHART for sensor- RTU communication .
Indicates content that may require registration and/or purchase.