Supplier: Mobile Air, Inc.
Description: The Mobile Steam Fan Coil 362 fits perfectly into a small or medium sized office, computer, or server room. It includes a mechanical thermostat, a 2hp fan motor, and is rated up to 200 psig stream supply. The 362 is an ideal portable heating unit for small office
- Maximum Air Flow: 12,160 SCFM
- Heater Type: Air Heater, Space Heater
- Fuel / Energy Source: Hot Water / Steam
- Phase: Single Phase
-
Supplier: Johnson Controls, Inc.
Description: Johnson Controls FN Series horizontal, high-performance, fan-coil units provide maximum performance while the unit’s array of options and number of available sizes render unparalleled flexibility. FEATURES AND BENEFITS Optimized performance – ARI-440 certified and labeled;
- Heating Capacity: 5.12925 to 47.39427 kW
- Maximum Air Flow: 600 to 2,000 SCFM
- Heater Type: Air Heater, Forced Air Heater, Space Heater
- Fuel / Energy Source: Hot Water / Steam
-
Supplier: Johnson Controls, Inc.
Description: chilled-water coil for cooling, hot-water or electric coil for heating. Flexible design – Exposed or concealed cabinet; 2- or 4-pipe coils. Piping packages - Factory-assembled piping packages available. Choice of controls – Thermostats can be analog, digital display, or
- Heating Capacity: 2,302.5936 to 18,232.5786 kW
- Maximum Air Flow: 230 to 920 SCFM
- Heater Type: Air Heater, Forced Air Heater, Space Heater
- Fuel / Energy Source: Hot Water / Steam
-
-
Supplier: Johnson Controls, Inc.
Description: Low profile vertical fan-coil units offer optimized performance, flexible design, choice of controls and more, to offer excellent performance and indoor air quality. FEATURES AND BENEFITS Optimized performance – ARI-440 certified and labeled; chilled-water coil for cooling,
- Heating Capacity: 3.45858 to 22.09974 kW
- Maximum Air Flow: 250 to 1,200 SCFM
- Heater Type: Air Heater, Forced Air Heater, Space Heater
- Fuel / Energy Source: Hot Water / Steam
-
Supplier: Johnson Controls, Inc.
Description: An extensive variety of components provide a flexible and versatile fan coil unit to meet the needs of any building. Plus, the variety of options available with FCC units is where you find the versatility to fit any heating, ventilating, and air-conditioning need. FEATURES AND BENEFITS
- Heating Capacity: 3.66375 to 29.57379 kW
- Maximum Air Flow: 400 to 2,000 SCFM
- Heater Type: Air Heater, Forced Air Heater, Space Heater
- Fuel / Energy Source: Hot Water / Steam
-
Supplier: Mobile Air, Inc.
Description: The Mobile Hot Water Coil 271 fits perfectly into a small or medium sized office, computer, or server room. It includes a 1/2 hp fan motor, a supply of 1 1/4" outlet and has a return 1 1/4" outlet. The HWC271 is an ideal portable heating unit for small office environments.
- Maximum Air Flow: 5,130 SCFM
- Heater Type: Air Heater, Space Heater
- Fuel / Energy Source: Hot Water / Steam
- Phase: Single Phase
-
Supplier: Thermon, Inc
Description: Caloritech™ Air Duct Heaters are designed for use in comfort heating applications such as makeup air heating, air preheating, air handling equipment, fan coils, terminal reheating, multizone reheating, heat pump auxiliary systems and return air heating. Unlike open coil
- AC Voltage Required: 120 to 600 volts
- Heater Type: Air Heater
- Features: Electric, Hot Water / Steam
- Phase: Single Phase
-
Supplier: Thermocold Costruzioni Srl
Description: antifreeze protection electric heater. • Condenser coils with seamless copper tubes and alluminium .ns. • Anti-legionella measures. • Condensing and evaporating pressure control with variable fan speed modulation for external temperature up to -25°C. • Hot sanitary water
- Heating Capacity: 50.64 to 67.02 kW
- AC Voltage Required: 400 volts
- Fuel / Energy Source: Hot Water / Steam
- Sleeve (Sheath) Material: None
-
Supplier: Thermocold Costruzioni Srl
Description: pressure switch and antifreeze protection electric heater. • Hot sanitary water evaporator stainless steel AISI 316 brazed plate type externally insulated complete of differential pressure switch and antifreeze protection electric heater. • Condenser coils with seamless copper
- Heating Capacity: 50.5 to 963.3 kW
- AC Voltage Required: 400 volts
- Fuel / Energy Source: Hot Water / Steam
- Sleeve (Sheath) Material: None
-
Supplier: CSA Group
Description: combinations of these functions. 1.5 A fan coil unit is intended to be piped to a remote source of the heating and/or cooling mediums. A unit that includes an electric resistance heater is considered to be a fan coil unit if a water or refrigerant coil for
-
Supplier: UL Standards & Engagement
Description: includes an electric resistance heater is considered to be a fan coil unit if a water or refrigerant coil for comfort cooling and/or a water or steam coil for comfort heating is provided in the unit. 1.6 A room fan heater unit is intended for
Find Suppliers by Category Top
Featured Products Top
-
(VFD), wind power generators and power converters, solar inverters, uninterruptable power supplies (UPS), transformers, heat sinks, fan coils, telecom racks and other industrial equipment; in air handling units and fan filter units (FFU); and in data center, railway, marine, military and avionics (read more)
Browse Electronic Cooling Fans Datasheets for Rosenberg USA -
variable frequency drives (VFD), wind power generators and power converters, solar inverters, uninterruptable power supplies (UPS), transformers, heat sinks, fan coils, telecom racks and other industrial equipment; in air handling units and fan filter units (FFU); and in railway, marine, military and (read more)
Browse HVAC Fans and Blowers Datasheets for Rosenberg USA -
configurations for forced air heaters, heat pumps, condensers, cooling units, evaporators, chillers, electronics cooling, air handling and other applications. Rosenberg’s simple Modbus interface allows multiple networked fans to operate separately and at variable speeds to better balance (read more)
Browse HVAC Fans and Blowers Datasheets for Rosenberg USA -
Caloritech™ Air Duct Heaters are designed for use in comfort heating applications such as makeup air heating, air preheating, air handling equipment, fan coils, terminal reheating, multizone reheating, heat pump auxiliary systems and return air heating. Unlike open coil designs, duct (read more)
Browse Duct Heaters Datasheets for Thermon, Inc -
the aerospace industry Sanitizing and sterilizing a wide range of products in the bio-pharmaceutical industry Solutions for providing electrical input If you need to provide electrical input to a fan, motor, heater or other AC or DC powered device (read more)
Browse Feedthroughs Datasheets for Conax Technologies -
environmentally friendly refrigerants to ensure rapid cooling. The refrigeration system includes an evaporator, condenser, and expansion valve, achieving cooling through refrigerant circulation. Heating System: The environmental chamber is equipped with a heater (such as an electric (read more)
Browse Environmental Test Chambers and Rooms Datasheets for Guangdong Atmars Industry Co., Limited -
, like a relay, it permits a small signal to handle a large load. Even a small DC signal from a MCU or PLC can activate a 240V AC heater or motor. However, SSRs can do this without wearing out and (read more)
Browse Solid State Relays Datasheets for ODG (Origin Data Global)
More Information Top
-
Perry's Chemical Engineers' Handbook, Eighth Edition > SOLIDS-DRYING FUNDAMENTALS
Table 12-23 gives approximate purchase costs for equipment with type 304 stainless-steel hinged conveyor screens and includes steam - coil heaters , fans , motors, and a variable-speed conveyor drive.
-
Spray Dryers: A Guide to Performance Evaluation 2nd Edition
Obtain all burner, fan , heater , steam coil , and product collection equipment performance data from the manufacturers.
-
Gasification Plant Cost and Performance Optimization
• Crushed Coal Feeder – Transfer Coal to Elevator,40 tph capacity • Kinergy Fluidized Bed Dryer - 40 tph capacity, with steam coil heater , FD and ID fans , dryer, cyclone separator, dust collector, ductwork, motors with 15, 40 and 50 hp.
-
Better Combustion Airflow Monitoring at the Hunan Yiyang Power Plant
Primary air is pulled in from the atmosphere by the fan and passed through a steam coil heater to heat the gas to the operating temperature of approximately 400F.
-
Micronized coal-fired retrofit system for SO{sub x} reduction. Technical progress report No. 1, [April--June 1996]
Babcock & Wilcolt FM-Series Package Boiler, equipped with B&W XCL Low NOx burner (w/. auxiliary oil gun), steam - coil air heater , FD fan , sootblowing syitem, and %n-floorlt pneumatic puffer system, Breeching and insulation between B&W economizer outlet and inlet to…
-
Krakow clean fossil fuels and energy efficiency program. Final report: Initial site investigation
Including economizers, micron-coal burners/oil lighter, FD fans , boiler trim, steam coil air heater , sootblowers, furnace floor "steam-puffer" system, spare part package, shipping, field service/start-up.
-
Rules of Thumb in Engineering Practice
Rotary roto louvre: (continuous, indirect or direct convection) atmospheric, c/s including heater or steam coil , dust collection, fans , motors, derives and controls.
Indicates content that may require registration and/or purchase.