Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: Cole-Parmer
Description: These labels offer a highly reliable and irreversible indication of exposure to low temperatures. Labels clearly indicate when the product to which it is attached to has been subjected to harsh temperatures, which could have detrimental effects on refrigerated pharmaceuticals,
- Type: Film / Label
-
Supplier: Cole-Parmer
Description: These labels offer a highly reliable and irreversible indication of exposure to low temperatures. Labels clearly indicate when the product to which it is attached to has been subjected to harsh temperatures, which could have detrimental effects on refrigerated pharmaceuticals,
- Type: Film / Label
-
Supplier: Cole-Parmer
Description: These labels offer a highly reliable and irreversible indication of exposure to low temperatures. Labels clearly indicate when the product to which it is attached to has been subjected to harsh temperatures, which could have detrimental effects on refrigerated pharmaceuticals,
- Type: Film / Label
-
-
Supplier: Cole-Parmer
Description: These labels offer a highly reliable and irreversible indication of exposure to low temperatures. Labels clearly indicate when the product to which it is attached to has been subjected to harsh temperatures, which could have detrimental effects on refrigerated pharmaceuticals,
- Type: Film / Label
-
Supplier: ASTM International
Description: salts. 1.2 Many water-based paints contain pigments and organic colorants that lose water of hydration or decompose at this temperature. The residual ash should be carefully inspected for changes in color or texture that could indicate a pigment alteration and hence lead to
-
Supplier: ASTM International
Description: salts. 1.2 Many water-based paints contain pigments and organic colorants that lose water of hydration or decompose at this temperature. The residual ash should be carefully inspected for changes in color or texture that could indicate a pigment alteration and hence lead to
-
Supplier: ASTM International
Description: salts. 1.2 Many water-based paints contain pigments and organic colorants that lose water of hydration or decompose at this temperature. The residual ash should be carefully inspected for changes in color or texture that could indicate a pigment alteration and hence lead to
-
Supplier: ASTM International
Description: salts. 1.2 Many water-based paints contain pigments and organic colorants that lose water of hydration or decompose at this temperature. The residual ash should be carefully inspected for changes in color or texture that could indicate a pigment alteration and hence lead to
-
Supplier: SAE International
Description: ergonomics and Aircraft operating procedures. Various handheld methods of temperature sensing or readouts, as these are not associated with transport aircraft during normal operation. Temperature sensitive paints as a means to indicate exceedance of a landing gear axle
-
Description: . Conforms to AWWA D102-03, OCS # 1 System Tested: (unless otherwise indicated) Substrate: Steel Surface Preparation: SSPC-SP6 1 ct. KEM® Kromik® Universal @ 3.0 mils dft 1 ct. Industrial Enamel VOC @ 3.0 mils dft Abrasion Resistance: Method: ASTM D4060, CS17 wheel, 1000 cycles, 1 kg
- Chemistry: Alkyd / Oil Based, Resin Base / Polymer Binder
- Cure / Dry Temperature: 50 to 110 F
- Features: Heat Resistant / High Temperature, Other
- Form: Liquid
-
Supplier: Hapco, Inc.
Description: easier to clean and perfect to use with our Food & Drug Grade materials Easy to Fill Tanks The MiniFIL’s tank lids are twist on/off and color coded to indicate which side you are filling. When closed properly, the covers are air tight and leak proof. Tank Fluid Level Gauge
- Application: Adhesive / Silicone, Coatings / Paint
- Container Size: 22712 to 45425 cc
- Container Type: Can / Pail / Drum
- Dispensing Type: Fill ("Potting")
-
Supplier: SAE International
Description: thermal exposure on residual stresses and relaxation in a high pressure die cast magnesium (AM60) alloy. The goal was to characterize relaxation of residual stresses at temperatures that are commonly experienced by body components during a typical paint bake cycle. A residual stress
-
Supplier: RS Components, Ltd.
Description: results indicate that the top solar shields for the COMLINE series cuts temperature rise by 25% due to solar heat load. Temperature & solar radiation protection is achieved thanks to ventilation on the top of the enclosure to absorb any heating effects. Finished in a grey RAL
-
Supplier: RS Components, Ltd.
Description: results indicate that the top solar shields for the COMLINE series cuts temperature rise by 25% due to solar heat load. Temperature & solar radiation protection is achieved thanks to ventilation on the top of the enclosure to absorb any heating effects. Finished in a grey RAL
-
Supplier: RS Components, Ltd.
Description: results indicate that the top solar shields for the COMLINE series cuts temperature rise by 25% due to solar heat load. Temperature & solar radiation protection is achieved thanks to ventilation on the top of the enclosure to absorb any heating effects. Finished in a grey RAL
-
Supplier: RS Components, Ltd.
Description: results indicate that the top solar shields for the COMLINE series cuts temperature rise by 25% due to solar heat load. Temperature & solar radiation protection is achieved thanks to ventilation on the top of the enclosure to absorb any heating effects. Finished in a grey RAL
-
Supplier: Hammond Manufacturing Company Inc.
Description: Features Designed for power distribution for the front or the rear of the unit. 1U horizontal 19" rackmount installation. Available with lighted on/off switch or red pilot light to indicate power on. Available in black powder coat finish
- Current Rating: 15 amps
- Nominal Voltage: Other
- Number of Electrical Outlets: 6
- Outlet Configuration: NEMA, Other
-
Supplier: Hammond Manufacturing Company Inc.
Description: Features Designed for power distribution for the front or the rear of the unit. 1U horizontal 19" rackmount installation. Available with lighted on/off switch or red pilot light to indicate power on. Available in black powder coat finish
- Current Rating: 15 amps
- Nominal Voltage: Other
- Number of Electrical Outlets: 6
- Outlet Configuration: NEMA, Other
-
Supplier: Gilson Company, Inc.
Description: indicating pyrometer with a needle temperature indicator accurate to ±2% of reading. The pyrometer is supplied with a chromel-alumel thermocouple. These furnaces are ideal for single-point operation or where manual adjustments to temperature are acceptable. The percent input
-
Supplier: Gilson Company, Inc.
Description: indicating pyrometer with a needle temperature indicator accurate to ±2% of reading. The pyrometer is supplied with a chromel-alumel thermocouple. These furnaces are ideal for single-point operation or where manual adjustments to temperature are acceptable. The percent input
-
Supplier: Gilson Company, Inc.
Description: indicating pyrometer with a needle temperature indicator accurate to ±2% of reading. The pyrometer is supplied with a chromel-alumel thermocouple. These furnaces are ideal for single-point operation or where manual adjustments to temperature are acceptable. The percent input
-
Supplier: Gilson Company, Inc.
Description: indicating pyrometer with a needle temperature indicator accurate to ±2% of reading. The pyrometer is supplied with a chromel-alumel thermocouple. These furnaces are ideal for single-point operation or where manual adjustments to temperature are acceptable. The percent input
-
Supplier: Rees, Inc.
Description: quality die-cast aluminum and painted with a yellow dry powder paint. The independently operating red indicating flag rotates 90 degrees when tripped. Manually returning the flag to its normal position resets the switch. Switches with less than 6 terminals are provided with two
- Actuation Type: Trip Wire (Rope Pull)
- Minimum Operating Force (Trip Force): 26.69 N
- Normally Closed Contacts: 2 #
- Normally Open Contacts: 2 #
-
Supplier: Rees, Inc.
Description: quality die-cast aluminum and painted with a yellow dry powder paint. The independently operating red indicating flag rotates 90 degrees when tripped. Manually returning the flag to its normal position resets the switch. Switch enclosures are provided with two 1/2" NPT conduit
- Actuation Type: Trip Wire (Rope Pull)
- Minimum Operating Force (Trip Force): 26.69 N
- Normally Closed Contacts: 1 #
-
Supplier: Rees, Inc.
Description: quality die-cast aluminum and painted with a yellow dry powder paint. The independently operating red indicating flag rotates 90 degrees when tripped. Manually returning the flag to its normal position resets the switch. Switches with less than 6 terminals are provided with two
- Actuation Type: Trip Wire (Rope Pull)
- Minimum Operating Force (Trip Force): 26.69 N
- Normally Closed Contacts: 2 #
- Normally Open Contacts: 2 #
-
Supplier: Rees, Inc.
Description: quality die-cast aluminum and painted with a yellow dry powder paint. The independently operating red indicating flag rotates 90 degrees when tripped. Manually returning the flag to its normal position resets the switch. Switches with less than 6 terminals are provided with two
- Actuation Type: Trip Wire (Rope Pull)
- Minimum Operating Force (Trip Force): 26.69 N
- Normally Closed Contacts: 2 #
- Normally Open Contacts: 2 #
-
Supplier: Hammond Manufacturing Company Inc.
Description: Features Designed for power distribution from front or rear of the unit. 1U horizontal 19" rackmount installation. Available with on/off switch or red pilot light to indicate power on. Specifications Heavy duty 12 gauge wire cord - 12
- Current Rating: 20 amps
- Nominal Voltage: Other
- Number of Electrical Outlets: 6
- Outlet Configuration: NEMA, Other
-
Supplier: Hammond Manufacturing Company Inc.
Description: ammeter (1.38" x 0.88" display). Digital ammeter accuracy +/- 0.1 Amps UL/cUL recognized Standard UL1363 file No. E166039 & CSA C22.2 No. 308-14 Operating temperature is from -20 degrees C to +60 degrees C Finished in textured RAL9005 black powder paint
- Current Rating: 20 amps
- Nominal Voltage: Other
- Number of Electrical Outlets: 6
- Outlet Configuration: NEMA, Other
-
Supplier: International Thermal Systems LLC.
Description: buttons, indicating lights and temperature controls are also included. We can also provide special electrical controls such as programmable logic control (PLC) systems including programming and documentation. Approaching each project as a partnership, the goal of our Engineering Staff
- Application / Operation: General Cleaning / Surface Prep
- Cleaning Process / Operation: Hot Water Cleaning
- Machine Mounting: Floor / Skid
- Power Source: Electric, Gas / Oil, Steam, Other
-
Supplier: FineTek
Description: corrosive & toxic liquids, hydrocarbons and slurries. ?Measurement unaffected by specific gravity,temperature, viscosity or foam. ?Echo wave display – resulting in accurate adjustment and parameter setting. ?Measuring range scanning, background noise
- Features: Handles Slurries / Suspended Solids
- Media Type: Liquid
- Output Options: Analog Current Signal (e.g., 4-20 mA)
-
Supplier: CSC Scientific Company, Inc.
Description: sensor which indicates temperatures between -50 °C to + 300 °C Accuracy: +/- 1 % of the full scale Repeatability: +/- 0.2% Display: Viscosity – Speed – Torque – Time –Temperature - Choice of viscosity units: cP/Poises or
- Display & Special Features: Computer Interface / Networkable, Laboratory / Benchtop (Batch)
-
Supplier: CSC Scientific Company, Inc.
Description: .05 to 13 mNm LR Version : 0.005 to 0.8 mNm Temperature: The FIRST PRO has a PT100 sensor which indicates temperatures between -50 °C to + 300 °C. Accuracy: +/- 1 % of the full scale Repeatability: +/- 0.2 % Display: Viscosity
- Display & Special Features: Computer Interface / Networkable, Laboratory / Benchtop (Batch)
- Technology Type: Vibratory / Oscillating Viscometry
-
Supplier: Konica Minolta Sensing Americas, Inc.
Description: size/distribution, overspray, improper flash/recoat time, inter coat compatibility, incorrect cure times and cure temperature. Measurement Scale: 0-100, 100 is a perfect smooth surface. REFLECTED IMAGE QUALITY (RIQ) Same as DOI, Reflected Image Quality (RIQ) is used to detect
- Property Measured: Gloss, Haze, Other
-
Supplier: Larson Electronics LLC
Description: Pan and Tilt: 370 degrees rotation with hard stop. 140 degrees tilt to direct upward beam position Mount: Magnetic - water tight 100 pound grip base - tested to 60mph - Magnetic base encapsulated in soft rubber to adapt to uneven vehicle surfaces and prevent scratches on vehicle paint
-
Supplier: Larson Electronics LLC
Description: on vehicle paint. - Wrap around base seal prevents dirt from entering the base of the light. Includes rubber cord grip. Voltage: 12 Volts DC appropriate for most consumer vehicles, off road vehicles and small boats Lamp Wattage: 35 Watts HID Amp Draw: 7.2 cold start, 3 amps
-
Supplier: Larson Electronics LLC
Description: on vehicle paint. - Wrap around base seal prevents dirt from entering the base of the light. Includes rubber cord grip. Voltage: 12 Volts DC appropriate for most consumer vehicles, off road vehicles and small boats Lamp Wattage: 35 Watt High Intensity Discharge Bulb - 3000 Lumens
Find Suppliers by Category Top
Featured Products Top
-
indicating paints were used to determine the time to temperature. A solder wire preform was placed on the part to allow for repeatable placement of solder in every joint. Four tops or four bottom joints can be heated at one time within 2-3 minutes for this soldering application. Full article... (read more)
Browse Datasheets for Ambrell Induction Heating Solutions -
temperate for this brazing application was 1200 °F (649 °C). Initial tests were conducted to optimize the power delivered to the assembly. Temperature indicating paint was then applied to the assembly, which dissolves when the assembly reaches the target temperature. It took 70 (read more)
Browse Industrial Heaters Datasheets for Ambrell Induction Heating Solutions -
°C). The LAB used temperature indicating paint for testing, which dissolves when the part reaches temperature. It took about 120 seconds to heat the part to temperature. The speed and end-product met the client’s objectives. There are numerous benefits to induction when (read more)
Browse Industrial Heaters Datasheets for Ambrell Induction Heating Solutions -
-designed multiple-turn helical coil was built to generate the required heating for the application. Temperature indicating paint was then applied to the part, which dissolves when the part reaches temperature. It took about 50 seconds to heat the part to temperature, which met the client's objectives (read more)
Browse Industrial Heaters Datasheets for Ambrell Induction Heating Solutions -
would be the right solution for their process requirements. Temperature indicating paint was applied to the part, which dissolves when the part reaches the target temperature. It took 2.5 seconds to heat the part to temperature with the EASYHEAT system set to a frequency of 325 kHz. This result met (read more)
Browse Industrial Heaters Datasheets for Ambrell Induction Heating Solutions -
-400 kHz induction heating system equipped with a remote workhead was ideal for the application. For testing, temperature indicating paint was applied to the part, which melts when the part reaches the targeted temperature. It took 30-40 seconds to heat one end of the sample to (read more)
Browse Industrial Heaters Datasheets for Ambrell Induction Heating Solutions -
6 kW, 150-400 kHz induction heating system was the right solution based on their application requirements. They also designed a single position multiple-turn helical coil for the testing. Temperature indicating paint was then applied to the part which dissolves when the part (read more)
Browse Datasheets for Ambrell Induction Heating Solutions -
helical coil would be the right fit for this desoldering application. Initial tests were conducted to optimize the power delivered to the assemblies. Temperature indicating paints were used to determine the heating time. It took 90 seconds or less to heat the samples (read more)
Browse Industrial Heaters Datasheets for Ambrell Induction Heating Solutions -
, temperature indicating paint was then applied. A thermocouple was also used to monitor temperature. The power was turned on for 0.5 seconds, which simulates the client's run rate. It was observed that the wire heated well to maintain the target temperature after three seconds, which is the time required for (read more)
Browse Industrial Heaters Datasheets for Ambrell Induction Heating Solutions -
temperate for this brazing application was 1200 °F (649 °C). Initial tests were conducted to optimize the power delivered to the assembly. Temperature indicating paint was then applied to the assembly, which dissolves when the assembly reaches the target temperature. It took 70 (read more)
Browse Industrial Heaters Datasheets for Ambrell Induction Heating Solutions
Conduct Research Top
-
Preheating an automotive transaxle (welding) [MEC]
The steel axle was painted with temperature indicating paint and a thermocouple was attached to the part...
-
Heating cylinder liners for insertion into aluminum engine blocks [PFS]
Temperature indicating paint was applied to the part for testing purposes. The part was then placed into the induction heating coil and the power was turned on. In just under 30 seconds, the part achieved temperature...
-
Emissivity of Most Common Materials
Emissivity is the measure of an object's ability to emit infrared energy. Emitted energy indicates the temperature of the object. Emissivity can have a value from 0 (shiny mirror) to 1.0 (blackbody). Most organic, painted, or oxidized surfaces have emissivity values close to 0.95. Majority
More Information Top
-
Thermal history paints - principles and progress
Keywords: Thermal paints, Phosphorescence, Thermal History sensor, Temperature measurement, Temperature indicating paint .
-
Handbook of Measurement in Science and Engineering, 2 Volume Set
Temperature indicating paints can be applied very readily to provide an indication of the temperatures that are being encountered.
-
A simple method for the estimation of laser absorptivity using heat-sensitive paints
Temperature indicating paint strips: (a) before and (b) after laser irradiation. . plane of symmetry . heat source . X . Y .
-
Melt Infiltrated Ceramic Composites (Hipercomp) for Gas Turbine Engine Applications
Photographic montage of the outer surface of the metallic combustor segments after rig test 4 showing the changes in color of the temperature indicating paint .
-
Power systems development facility. Quarterly technical progress report, July 1--September 30, 1993
Temperature Indicating Paint .
-
Surface temperature measurement on engine components by means of irreversible thermal coatings
A thermal paint, or temperature indicating paint , typically comprises solvents (≈60 wt%), binding agents (≈30 wt%), pigments (≈8 wt%) and mineral fillers. .
-
Temperature Measurement 2nd Edition
A typical example of multiple temperature indicating paint is the No. 69 paint manufactured by Synthetic and Industrial Finishes Ltd.
-
Advanced Turbine Technology Applications Project (ATTAP) and Hybrid Vehicle Turbine Engine Technology Support project (HVTE-TS): Final summary report
The outer walls of the ceramic were painted with temperature indi- cating paints .
-
Color coding orifices
ature paints, ceramic paints, temperature indicating paints , and cements were investigated.
-
Fault Location in SF6 Insulated Substations Using Thermal Techniques
Since most commercially available temperature indicat- ing paints are of proprietary nature, the exact formu- lation of these paints are not readily available.
Indicates content that may require registration and/or purchase.