Three Phase Over-the-Side Heaters

36 Results
Over The Side Heaters
from WATTCO

Over the Side Heaters are a popular industrial heating product for economic and practical uses. Using a water-resistant terminal housing, these industrial heaters come in many shapes and sizes to fit within your tank dimensions and specifications. Wattco over the side immersion heaters are custom... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • Watt Density: 14 to 60
  • AC Voltage Required: 208 to 600
  • Applications: Clean Water Heating; Process Waters; Lightweight Oils & Degreasing Solutions; Medium Weight Oils; Heavy Weight Oils; Caustic Solutions; Liquid Paraffin; Solvents, Salts, Freeze Protection
(PTFE) 3-Element L-Shaped Heater
from Tempco Electric Heater Corporation

Typical Applications. Compatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190 °F (88 °C). Replaces more expensive alumina or graphite heaters. T1 thermal fuse protection standard; T2 bi-metal switch optional. Grounded internal metal element for... [See More]

  • Phase: Three Phase AC Voltage
  • AC Voltage Required: 240 to 480
  • Maximum Operating (Sheath) Temperature: 190
  • Watts: 3.00 to 18.00
(PTFE) 3-Element OTS Heater
from Tempco Electric Heater Corporation

Typical Applications. Compatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190 °F (88 °C). Replaces more expensive alumina or graphite heaters. T1 thermal fuse protection standard; T2 bi-metal switch optional. Grounded internal metal element for... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • AC Voltage Required: 120 to 480
  • Maximum Operating (Sheath) Temperature: 190
  • Watts: 1.00 to 6.00
(PTFE) 6-Element OTS Heater
from Tempco Electric Heater Corporation

Typical Applications. Compatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190 °F (88 °C). Replaces more expensive alumina or graphite heaters. T1 thermal fuse protection standard; T2 bi-metal switch optional. Grounded internal metal element for... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • AC Voltage Required: 120 to 480
  • Maximum Operating (Sheath) Temperature: 190
  • Watts: 2.00 to 12.00
(PTFE) 9-Element OTS Heater
from Tempco Electric Heater Corporation

Typical Applications. Compatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190 °F (88 °C). Replaces more expensive alumina or graphite heaters. T1 thermal fuse protection standard; T2 bi-metal switch optional. Grounded internal metal element for... [See More]

  • Phase: Three Phase AC Voltage
  • AC Voltage Required: 240 to 480
  • Maximum Operating (Sheath) Temperature: 190
  • Watts: 3.00 to 18.00
?3-Tube Vertical Stack L-Shape Heater
from Tempco Electric Heater Corporation

Typical Applications. For plating tanks, rinse tanks and other non-sludging aqueous solutions. T1 thermal fuse protection standard; T2 bi-metal switch optional. Grounded for safety. Vapor-tight polypropylene terminal enclosure. Standard 3-ft. flexible PVC liquid-tight conduit. 240, 480 volts... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • AC Voltage Required: 240 to 480
  • Maximum Operating (Sheath) Temperature: 180 to 300
  • Watts: 3.00 to 36.00
?Metal Single-Tube L-Shaped Heater
from Tempco Electric Heater Corporation

Typical Applications. For plating tanks, rinse tanks and other non-sludging aqueous solutions. T1 thermal fuse protection standard; T2 bi-metal switch optional. Grounded for safety. Vapor-tight polypropylene terminal enclosure. Standard 3-ft. flexible PVC liquid-tight conduit. 120, 240, 480 volts... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • AC Voltage Required: 120 to 480
  • Maximum Operating (Sheath) Temperature: 180 to 300
  • Watts: 1.00 to 12.00
?Metal Single-Tube Style Heater
from Tempco Electric Heater Corporation

Typical Applications. For plating tanks, rinse tanks and other acidic aqueous solutions. T1 thermal fuse protection standard; T2 bi-metal switch optional. Grounded for safety. Vapor-tight polypropylene terminal enclosure with universal mounting flange. Standard 3-ft. flexible PVC liquid-tight... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • AC Voltage Required: 120 to 480
  • Maximum Operating (Sheath) Temperature: 180 to 300
  • Watts: 5.00 to 12.00
?Metal Triple-Tube L-Shaped Heater
from Tempco Electric Heater Corporation

Typical Applications. For plating tanks, rinse tanks and other non-sludging aqueous solutions. T1 thermal fuse protection standard; T2 bi-metal switch optional. Grounded for safety. Vapor-tight polypropylene terminal enclosure. Standard 3-ft. flexible PVC liquid-tight conduit. 240, 480 volts... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • AC Voltage Required: 240 to 480
  • Maximum Operating (Sheath) Temperature: 180 to 300
  • Watts: 3.00 to 36.00
?Metal Triple-Tube Style Heater
from Tempco Electric Heater Corporation

Typical Applications. For plating tanks, phosphatizing and concentrated aqueous solutions. T1 thermal fuse protection standard; T2 bi-metal switch optional. Grounded for safety. Vapor-tight polypropylene terminal enclosure with universal mounting flange. Standard 3-ft. flexible PVC liquid-tight... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • AC Voltage Required: 120 to 480
  • Maximum Operating (Sheath) Temperature: 180 to 300
  • Watts: 3.00 to 18.00
?Quartz 1- and 3-Tube Style Heaters
from Tempco Electric Heater Corporation

Standard guards are made of polypropylene. Fluoropolymer (PTFE) guards are available for chromic acid and temperatures above 180 °F (82 °C). T1 thermal fuse protection standard; T2 bi-metal switch optional. Grounded for safety. Vapor-tight polypropylene terminal enclosure with universal. [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • AC Voltage Required: 120 to 480
  • Maximum Operating (Sheath) Temperature: 180 to 220
  • Watts: 0.50 to 30.00
1 or 3 Phase Derated Single Metal Bottom Heater -- DLMOTS
from Process Technology

Durable, efficient chemical heater. FEATURES. Heavy wall metal sheaths available in steel, 304 stainless steel, 316 stainless steel and titanium. Low watt densities of 18 watts/square inch (2.8 w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • AC Voltage Required: 120 to 600
  • Maximum Operating (Sheath) Temperature: 180
  • Watts: 0.50 to 6.00
Over The Side Immersion Heater -- TLO & KTLO
from OMEGA Engineering, Inc.

Tubular heating elements are brazed into a junction box. All wetted parts of TLO & KTLO Series heaters are steel. Sludge legs (to keep heated portion of the unit off the bottom of the tank) are standard. [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • Watts: 2.00 to 10.00
  • AC Voltage Required: 120 to 480
  • Watt Density: 20
Immersion Heater - Over-the-side - Deep Tank Blade Heater -- BLCK-MH
from Chromalox

Circular Blades. Steel Sheath Elements. Low Watt Density (12 and 18 W/In ²). 7.5 - 24 kW. 240 and 480 Volt, 1 and 3 Phase. Moisture Resistant Terminal Enclosure. 12 ft. Riser (Other Lengths Available) [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • Watts: 7.50 to 24.00
  • AC Voltage Required: 240 to 480
  • Watt Density: 12 to 18
1 or 3 Phase Over the Side Phosphate Application Heater -- DAS
from Process Technology

Customer designed specifically for phosphate coating applications. FEATURES. For use in iron, zinc and manganese phosphate tanks. Schedule 40, heavy wall, 316 stainless steel sheath withstands scaling better than traditional heaters. Low watt densities up to 23 watts/square inch (3.5 w/cm ²)... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • AC Voltage Required: 120 to 600
  • Maximum Operating (Sheath) Temperature: 230
  • Watts: 1.00 to 10.00
Over-the Side Immersion Heater -- TLI & KTLI
from OMEGA Engineering, Inc.

These over-the-side immersion heaters are designed for vessels where through the side immersion heaters cannot be conveniently installed. These heaters are installed through the top of the vessel with the heated portion of the unit along the side or at the bottom of the tank. Natural circulation of... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • Watts: 2.00 to 18.00
  • AC Voltage Required: 120 to 480
  • Watt Density: 40
Immersion Heater - Over-the-side - Deep Tank Blade Heater -- BLCS
from Chromalox

Straight Blade. Steel Sheath Elements. Low Watt Density (12 and 18 W/In ²). 7.5 - 24 kW. 240 and 480 Volt, 1 and 3 Phase. Moisture Resistant Terminal Enclosure. 12 ft. Riser (Other Lengths Available). Third-party certifications: UL Listed, CSA [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • Watts: 7.50 to 24.00
  • AC Voltage Required: 240 to 480
  • Watt Density: 12 to 18
3 Element Tubular 3 Phase Over the Side Heater -- 3HS
from Process Technology

Durable, efficient chemical heater. FEATURES. Heavy wall metal sheaths available in steel, 304 stainless steel, 316 stainless steel and titanium. Watt densities up to 40 watts/square inch (6.2 w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible... [See More]

  • Phase: Single Phase AC Voltage (optional feature); Three Phase AC Voltage
  • AC Voltage Required: 200 to 600
  • Maximum Operating (Sheath) Temperature: 180
  • Watts: 3.00 to 10.50
Over-the Side Immersion Heater -- TLS & KTLS
from OMEGA Engineering, Inc.

These over-the -side immersion heaters are designed for installing in the top of a tank with the heated portion directly immersed along the side or at the bottom. This provides easy removal of the heater and ample working space inside the tank. [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • Watts: 2.00 to 18.00
  • AC Voltage Required: 120 to 480
  • Watt Density: 40
Immersion Heater - Over-the-side - L-Shaped Fluoropolymer Covered Heater -- GTFL3
from Chromalox

Fluoropolymer Covered Stainless Steel Elements. 10 W/in ². 3 - 18 kW. 240 and 480 Volt, Three Phase. Moisture Resistant Terminal Enclosure. Third-party certifications: UL Listed, cUL [See More]

  • Phase: Three Phase AC Voltage
  • AC Voltage Required: 240 to 480
  • Maximum Operating (Sheath) Temperature: 180 to 219
  • Watts: 3.00 to 18.00
3 Phase Over the Side Triple Metal Deep Tank Heater -- 3V
from Process Technology

Durable, efficient chemical heater. FEATURES. Heavy wall metal sheaths available in steel, 304 stainless steel, 316 stainless steel and titanium. Watt densities up to 35 watts/square inch (5.4 w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible... [See More]

  • Phase: Three Phase AC Voltage
  • AC Voltage Required: 240 to 600
  • Maximum Operating (Sheath) Temperature: 180
  • Watts: 18.00 to 54.00
Over-the-side Immersion Heater -- TLC and KTLC
from OMEGA Engineering, Inc.

These heaters are lightweight and portable and provide convenient solutions to many heating applications. TLC Series heaters have two or three straight heating elements, while KTLC Series heaters have two or three curved heating elements. [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • Watts: 2.00 to 18.00
  • AC Voltage Required: 120 to 480
  • Watt Density: 40
Immersion Heater - Over-the-side - L-Shaped Metal Heater -- TLI
from Chromalox

INCOLOY ® Sheath Elements W/In ²). Stainless Steel Riser (36 and 48"). 120, 240 and 480 Volt, 1 and 3 Phase. Moisture Resistant Terminal Enclosure. For Corrosive Fluids. 2 Element 2 - 12 kW. 3 Element 3 - 18 kW. Third-party certifications: UL Listed, CSA [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • Watts: 2.00 to 18.00
  • AC Voltage Required: 120 to 480
  • Watt Density: 40
6 Element Tubular 3 Phase Over the Side Heater -- 6HS
from Process Technology

Durable, efficient chemical heater. FEATURES. Heavy wall metal sheaths available in 316 stainless steel. Watt densities up to 40 watts/square inch (6.2 w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit. Grounded... [See More]

  • Phase: Three Phase AC Voltage
  • AC Voltage Required: 200 to 600
  • Maximum Operating (Sheath) Temperature: 180
  • Watts: 6.00 to 21.00
Side Mount Fluoropolymer Covered Heaters -- GTF6 and GTF9 Styles
from OMEGA Engineering, Inc.

FEATURES. • Moisture Resistant Terminal Enclosure. • Side Mounted Construction with Mounting Flange. • Overtemperature Protection One Time Use Thermal Fuse (260 °F), Field Replaceable. • Polypropylene Guard, Order Separately. • Custom Vertical Heights and Other... [See More]

  • Phase: Three Phase AC Voltage
  • AC Voltage Required: 240 to 480
  • Maximum Operating (Sheath) Temperature: 260
  • Watts: 2.00 to 12.00
Immersion Heater - Over-the-side - L-Shaped Metal Sheath Heater -- KTLC
from Chromalox

Copper Sheath Elements (40 W/In ²). 304 SS Riser. 120, 240 and 480V, 1 and 3 Phase. Moisture Resistant Terminal Enclosure. For Clean Water. 2 Element 2 - 12 kW. 3 Element 3 - 18 kW. Third-party certifications: UL Listed, CSA [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • Watts: 2.00 to 18.00
  • AC Voltage Required: 120 to 480
  • Sleeve (Sheath) Material: Copper
Derated Triple Metal Over the Side Chemical Heater -- 3DMOTS
from Process Technology

Durable, efficient chemical heater. FEATURES. Heavy wall metal sheaths available in steel, 304 stainless steel, 316 stainless steel and titanium. Low watt densities of 18 watts/square inch (2.8 w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • AC Voltage Required: 120 to 600
  • Maximum Operating (Sheath) Temperature: 180
  • Watts: 1.50 to 18.00
Immersion Heater - Over-the-side - L-Shaped Metal Sheath Heater -- KTLI
from Chromalox

INCOLOY ® Sheath Elements (40W/In ²). Stainless Steel Riser (36 and 48"). 120, 240 and 480 Volt, 1 and 3 Phase. Moisture Resistant Terminal Enclosure. For Corrosive Fluids. 2 Element 2 - 12 kW. 3 Element 3 - 18 kW. Third-party certifications: UL Listed, CSA [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • Watts: 2.00 to 18.00
  • AC Voltage Required: 120 to 480
  • Watt Density: 40
Fluoropolymer 3 Phase Over the Side Heater -- 3HX Style
from Process Technology

Excellent chemical resistance to aggressive acids. FEATURES. PTFE sleeved 304 stainless elements inert to most solutions up to 212 °F (100 °C). Low watt density design 10 watts/square inch (1.5w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m)... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • AC Voltage Required: 120 to 600
  • Maximum Operating (Sheath) Temperature: 212
  • Watts: 1.00 to 6.00
Immersion Heater - Over-the-side - L-Shaped Metal Sheath Heater -- KTLO
from Chromalox

Steel Sheath Elements (20 W/In ²). Steel Riser (36 and 48"). 120, 240 and 480V, 1 and 3 Phase. Moisture Resistant terminal Enclosure. For Medium Weight Oils & Degreasing Solutions. 2 Element 2 - 7 kW. 3 Element 3 - 10 kW. Third-party certifications: UL Listed, CSA [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • Watts: 2.00 to 10.00
  • AC Voltage Required: 120 to 480
  • Watt Density: 20
Fluoropolymer 3 Phase Over the Side Heater -- 6HX Style
from Process Technology

Excellent chemical resistance to aggressive acids. FEATURES. PTFE sleeved 304 stainless elements inert to most solutions up to 212 °F (100 °C). Low watt density design 10 watts/square inch (1.5w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m)... [See More]

  • Phase: Single Phase AC Voltage (optional feature); Three Phase AC Voltage
  • AC Voltage Required: 120 to 600
  • Maximum Operating (Sheath) Temperature: 212
  • Watts: 2.00 to 12.00
Immersion Heater - Over-the-side - L-Shaped Metal Sheath Heater -- KTLS
from Chromalox

Stainless Steel Sheath Elements (40 W/In ²). Stainless Steel Riser (36 and 48"). 120, 240 and 480V, 1 and 3 Phase. Moisture Resistant Terminal Enclosure. For Mildly Corrosive Fluids. 2 Element 2 - 12 kW. 3 Element 3 - 18 kW. Third-party certifications: UL Listed, CSA [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • Watts: 2.00 to 18.00
  • AC Voltage Required: 120 to 480
  • Watt Density: 40
Fluoropolymer 3 Phase Over the Side Heater -- 9HX Style
from Process Technology

Excellent chemical resistance to aggressive acids. FEATURES. PTFE sleeved 304 stainless elements inert to most solutions up to 212 °F (100 °C). Low watt density design 10 watts/square inch (1.5w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m)... [See More]

  • Phase: Single Phase AC Voltage (optional feature); Three Phase AC Voltage
  • AC Voltage Required: 120 to 600
  • Maximum Operating (Sheath) Temperature: 212
  • Watts: 3.00 to 18.00
Immersion Heater - Over-the-side - L-Shaped Metal Sheath Heater -- TLC
from Chromalox

Copper Sheath Elements (40 W/In ²). 304 Stainless Steel Riser. 120, 240 and 480V, 1 and 3 Phase. Moisture Resistant Terminal Enclosure. For Clean Water. 2 Element 2 - 12 kW. 3 Element 3 - 18 kW. Third-party certifications: UL Listed, CSA [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • Watts: 12.00 to 18.00
  • AC Voltage Required: 120 to 480
  • Watt Density: 40
Quartz Single or Triple Over the Side Heater -- QM/QM3
from Process Technology

Compatible with many aggressive chemistries. FEATURES. Heavy wall quartz sheath with replaceable metal element and polypropylene guards (complete assembly) . For use in most aqueous acidic plating solutions and pickling tanks. Watt densities up to 25 watts/square inch (4 w/cm ²). Vapor... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • AC Voltage Required: 120 to 600
  • Maximum Operating (Sheath) Temperature: 230
  • Watts: 0.50 to 10.00
Immersion Heater - Over-the-side - L-Shaped Metal Sheath Heater -- TLO
from Chromalox

Steel Sheath Elements (20 W/In ²). Steel Riser (36 and 48"). 120, 240 and 480V, 1 and 3 Phase. Moisture Resistant Terminal Enclosure. For Medium Weight Oils & Degreasing Solutions. 2 Element 2 - 7 kW. 3 Element 3 - 10 kW. Third-party certifications: UL Listed, CSA [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • Watts: 2.00 to 10.00
  • AC Voltage Required: 120 to 480
  • Watt Density: 20