Single Phase Over-the-Side Heaters

41 Results
Over-the-Side Drum Heater, Direct Immersion -- DT Series
from Backer Hotwatt Inc.

Features: Designed for direct immersion thru 2 ” bung opening in 55 gallon drums. Incoloy sheath for long life in most materials. 60-250 ̊F integral thermostat. Manual reset thermostat protects against overheating. Adjustable mounting bracket. Low watt density (1000w - 120w - 8w watts per... [See More]

  • Phase: Single Phase AC Voltage
  • AC Voltage Required: 120 to 240
  • Maximum Operating (Sheath) Temperature: 60 to 250
  • Watts: 1.00 to 4.00
(PTFE) 1-Element Coil Heater
from Tempco Electric Heater Corporation

Typical Applications. Compatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190 °F (88 °C). Replaces more expensive alumina or graphite heaters. T1 thermal fuse protection standard; T2 bi-metal switch optional. Grounded internal metal element for... [See More]

  • Phase: Single Phase AC Voltage
  • AC Voltage Required: 120 to 480
  • Maximum Operating (Sheath) Temperature: 190
  • Watts: 0.50 to 6.00
Over The Side Heaters
from WATTCO

Over the Side Heaters are a popular industrial heating product for economic and practical uses. Using a water-resistant terminal housing, these industrial heaters come in many shapes and sizes to fit within your tank dimensions and specifications. Wattco over the side immersion heaters are custom... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • Watt Density: 14 to 60
  • AC Voltage Required: 208 to 600
  • Applications: Clean Water Heating; Process Waters; Lightweight Oils & Degreasing Solutions; Medium Weight Oils; Heavy Weight Oils; Caustic Solutions; Liquid Paraffin; Solvents, Salts, Freeze Protection
(PTFE) 1-Element L-Shaped Coil Heater
from Tempco Electric Heater Corporation

Typical Applications. Compatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190 °F (88 °C). Replaces more expensive alumina or graphite heaters. T1 thermal fuse protection standard; T2 bi-metal switch optional. Grounded internal metal element for... [See More]

  • Phase: Single Phase AC Voltage
  • AC Voltage Required: 120 to 480
  • Maximum Operating (Sheath) Temperature: 190
  • Watts: 0.50 to 6.00
(PTFE) 1-Element L-Shaped Round Heater
from Tempco Electric Heater Corporation

Typical Applications. Compatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190 °F (88 °C). Replaces more expensive alumina or graphite heaters. T1 thermal fuse protection standard; T2 bi-metal switch optional. Grounded internal metal element for... [See More]

  • Phase: Single Phase AC Voltage
  • AC Voltage Required: 120 to 480
  • Maximum Operating (Sheath) Temperature: 190
  • Watts: 0.50 to 6.00
(PTFE) 1-Element Round Heater
from Tempco Electric Heater Corporation

Typical Applications. Compatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190 °F (88 °C). Replaces more expensive alumina or graphite heaters. T1 thermal fuse protection standard; T2 bi-metal switch optional. Grounded internal metal element for... [See More]

  • Phase: Single Phase AC Voltage
  • AC Voltage Required: 120 to 480
  • Maximum Operating (Sheath) Temperature: 190
  • Watts: 0.50 to 6.00
(PTFE) 3-Element OTS Heater
from Tempco Electric Heater Corporation

Typical Applications. Compatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190 °F (88 °C). Replaces more expensive alumina or graphite heaters. T1 thermal fuse protection standard; T2 bi-metal switch optional. Grounded internal metal element for... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • AC Voltage Required: 120 to 480
  • Maximum Operating (Sheath) Temperature: 190
  • Watts: 1.00 to 6.00
(PTFE) 6-Element OTS Heater
from Tempco Electric Heater Corporation

Typical Applications. Compatible with most plating tank solutions; inert to acids, anodizing and pickling solutions up to 190 °F (88 °C). Replaces more expensive alumina or graphite heaters. T1 thermal fuse protection standard; T2 bi-metal switch optional. Grounded internal metal element for... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • AC Voltage Required: 120 to 480
  • Maximum Operating (Sheath) Temperature: 190
  • Watts: 2.00 to 12.00
?3-Tube Vertical Stack L-Shape Heater
from Tempco Electric Heater Corporation

Typical Applications. For plating tanks, rinse tanks and other non-sludging aqueous solutions. T1 thermal fuse protection standard; T2 bi-metal switch optional. Grounded for safety. Vapor-tight polypropylene terminal enclosure. Standard 3-ft. flexible PVC liquid-tight conduit. 240, 480 volts... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • AC Voltage Required: 240 to 480
  • Maximum Operating (Sheath) Temperature: 180 to 300
  • Watts: 3.00 to 36.00
?Metal Single-Tube L-Shaped Heater
from Tempco Electric Heater Corporation

Typical Applications. For plating tanks, rinse tanks and other non-sludging aqueous solutions. T1 thermal fuse protection standard; T2 bi-metal switch optional. Grounded for safety. Vapor-tight polypropylene terminal enclosure. Standard 3-ft. flexible PVC liquid-tight conduit. 120, 240, 480 volts... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • AC Voltage Required: 120 to 480
  • Maximum Operating (Sheath) Temperature: 180 to 300
  • Watts: 1.00 to 12.00
?Metal Single-Tube Style Heater
from Tempco Electric Heater Corporation

Typical Applications. For plating tanks, rinse tanks and other acidic aqueous solutions. T1 thermal fuse protection standard; T2 bi-metal switch optional. Grounded for safety. Vapor-tight polypropylene terminal enclosure with universal mounting flange. Standard 3-ft. flexible PVC liquid-tight... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • AC Voltage Required: 120 to 480
  • Maximum Operating (Sheath) Temperature: 180 to 300
  • Watts: 5.00 to 12.00
?Metal Triple-Tube L-Shaped Heater
from Tempco Electric Heater Corporation

Typical Applications. For plating tanks, rinse tanks and other non-sludging aqueous solutions. T1 thermal fuse protection standard; T2 bi-metal switch optional. Grounded for safety. Vapor-tight polypropylene terminal enclosure. Standard 3-ft. flexible PVC liquid-tight conduit. 240, 480 volts... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • AC Voltage Required: 240 to 480
  • Maximum Operating (Sheath) Temperature: 180 to 300
  • Watts: 3.00 to 36.00
1 or 3 Phase Derated Single Metal Bottom Heater -- DLMOTS
from Process Technology

Durable, efficient chemical heater. FEATURES. Heavy wall metal sheaths available in steel, 304 stainless steel, 316 stainless steel and titanium. Low watt densities of 18 watts/square inch (2.8 w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • AC Voltage Required: 120 to 600
  • Maximum Operating (Sheath) Temperature: 180
  • Watts: 0.50 to 6.00
Over The Side Immersion Heater -- TLO & KTLO
from OMEGA Engineering, Inc.

Tubular heating elements are brazed into a junction box. All wetted parts of TLO & KTLO Series heaters are steel. Sludge legs (to keep heated portion of the unit off the bottom of the tank) are standard. [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • Watts: 2.00 to 10.00
  • AC Voltage Required: 120 to 480
  • Watt Density: 20
Immersion Heater - Over-the-side - Deep Tank Blade Heater -- BLCK-MH
from Chromalox

Circular Blades. Steel Sheath Elements. Low Watt Density (12 and 18 W/In ²). 7.5 - 24 kW. 240 and 480 Volt, 1 and 3 Phase. Moisture Resistant Terminal Enclosure. 12 ft. Riser (Other Lengths Available) [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • Watts: 7.50 to 24.00
  • AC Voltage Required: 240 to 480
  • Watt Density: 12 to 18
1 or 3 Phase Over the Side Phosphate Application Heater -- DAS
from Process Technology

Customer designed specifically for phosphate coating applications. FEATURES. For use in iron, zinc and manganese phosphate tanks. Schedule 40, heavy wall, 316 stainless steel sheath withstands scaling better than traditional heaters. Low watt densities up to 23 watts/square inch (3.5 w/cm ²)... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • AC Voltage Required: 120 to 600
  • Maximum Operating (Sheath) Temperature: 230
  • Watts: 1.00 to 10.00
Over the Side Immersion Heaters -- PTH
from OMEGA Engineering, Inc.

e PTH series models are heavy duty general purpose heaters for heating plating tanks, rinse tanks and other aqueous solutions. The Type 316 Stainless Steel is passivated to provide additional corrosion resistance. These heaters are equipped with a vapor tight terminal enclosure and a 3 foot long... [See More]

  • Phase: Single Phase AC Voltage
  • Watts: 5.00 to 7.50
  • AC Voltage Required: 120 to 480
  • Watt Density: 25 to 44
Immersion Heater - Over-the-side - Deep Tank Blade Heater -- BLCS
from Chromalox

Straight Blade. Steel Sheath Elements. Low Watt Density (12 and 18 W/In ²). 7.5 - 24 kW. 240 and 480 Volt, 1 and 3 Phase. Moisture Resistant Terminal Enclosure. 12 ft. Riser (Other Lengths Available). Third-party certifications: UL Listed, CSA [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • Watts: 7.50 to 24.00
  • AC Voltage Required: 240 to 480
  • Watt Density: 12 to 18
Aquaculture Heater -- EasyPlug™ Series
from Process Technology

Quick plug in system for aquaculture applications. 316 stainless steel for fresh water or titanium for salt water applications. Watt densities up to 40 watts/square inch (6.5 w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 8.5 flexible cord/plug. P1 thermal... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage (optional feature)
  • Watts: 1.00 to 5.60
  • AC Voltage Required: 100 to 480
  • Watt Density: 40
Over the Side Immersion Heaters -- PTHF
from OMEGA Engineering, Inc.

• Corrosion Resistant. • Solutions up to 212 °F (100 °C). • Thin Blade Heating Element. • 1 or 3 Phase Design. • Overtemperature Protection [See More]

  • Phase: Single Phase AC Voltage
  • AC Voltage Required: 240
  • Maximum Operating (Sheath) Temperature: 950
  • Watts: 3.00 to 10.00
Immersion Heater - Over-the-side - Fluoropolymer Covered Heater -- GTF
from Chromalox

Side Mount. Fluoropolymer Covered Stainless Steel Elements. 10 W/in ². 1 - 6 kW. 120, 240 and 480 Volt, Single Phase. Moisture Resistant Terminal Enclosure. Third-party certifications: UL Listed, cUL [See More]

  • Phase: Single Phase AC Voltage
  • AC Voltage Required: 120 to 480
  • Maximum Operating (Sheath) Temperature: 180 to 219
  • Watts: 1.00 to 6.00
Derated Single Metal Over The Side Heater For Concentrated Alkaline Or Caustic Solutions -- DMOTS
from Process Technology

Durable, efficient chemical heater. FEATURES. Heavy wall metal sheaths available in steel, 304 stainless steel, 316 stainless steel and titanium. Low watt densities of 18 watts/square inch (2.8 w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage (optional feature)
  • AC Voltage Required: 120 to 600
  • Maximum Operating (Sheath) Temperature: 180
  • Watts: 0.50 to 6.00
Over-the Side Immersion Heater -- TLI & KTLI
from OMEGA Engineering, Inc.

These over-the-side immersion heaters are designed for vessels where through the side immersion heaters cannot be conveniently installed. These heaters are installed through the top of the vessel with the heated portion of the unit along the side or at the bottom of the tank. Natural circulation of... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • Watts: 2.00 to 18.00
  • AC Voltage Required: 120 to 480
  • Watt Density: 40
Immersion Heater - Over-the-side - Fluoropolymer Covered Heater -- GTFL
from Chromalox

L-Shaped. Fluoropolymer Covered Stainless Steel Elements. 10 W/in ². 1 - 6 kW. 120, 240 and 480 Volt, Single Phase. Moisture Resistant Terminal Enclosure. Third-party certifications: UL Listed, cUL [See More]

  • Phase: Single Phase AC Voltage
  • AC Voltage Required: 120 to 480
  • Maximum Operating (Sheath) Temperature: 180 to 219
  • Watts: 1.00 to 6.00
Derated Triple Metal Over the Side Chemical Heater -- 3DMOTS
from Process Technology

Durable, efficient chemical heater. FEATURES. Heavy wall metal sheaths available in steel, 304 stainless steel, 316 stainless steel and titanium. Low watt densities of 18 watts/square inch (2.8 w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • AC Voltage Required: 120 to 600
  • Maximum Operating (Sheath) Temperature: 180
  • Watts: 1.50 to 18.00
Over-the Side Immersion Heater -- TLS & KTLS
from OMEGA Engineering, Inc.

These over-the -side immersion heaters are designed for installing in the top of a tank with the heated portion directly immersed along the side or at the bottom. This provides easy removal of the heater and ample working space inside the tank. [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • Watts: 2.00 to 18.00
  • AC Voltage Required: 120 to 480
  • Watt Density: 40
Immersion Heater - Over-the-side - Fluoropolymer Covered Heater -- GXF
from Chromalox

Side Mount. Fluoropolymer Covered Stainless Steel Elements. 10 W/in ². Third-party certifications: UL Listed, CSA, CE. 1 - 6 kW. 120, 240 and 480 Volt, Single Phase. Moisture/Corrosion Resistant Terminal Enclosure. Third-party certifications: UL Listed, CSA, CE [See More]

  • Phase: Single Phase AC Voltage
  • AC Voltage Required: 120 to 480
  • Maximum Operating (Sheath) Temperature: 180 to 219
  • Watts: 1.00 to 6.00
EasyPlug, Aquaculture Heater -- SmartOne®
from Process Technology

Designed for safety and low maintenance. FEATURES. Automatic temperature protection is built in. Won't burn out due to air or scale exposure. 316 stainless steel for fresh water or titanium for salt water applications. Available in Over the Side, L Shaped and Axial Styles. Watt densities up to 40... [See More]

  • Phase: Single Phase AC Voltage
  • Watts: 1.00 to 1.70
  • AC Voltage Required: 100 to 240
  • Watt Density: 40
Over-the Side Immersion Heater -- TPR and TPF
from OMEGA Engineering, Inc.

1. Corrosion Resistan- Thermoplastic fluoropolymer coated stainless steel sheath for long life in almost all types of corrosive solutions for operating temperatures up to 212F. Pin hole free, durable coating, 100% tested at factory. 2. Overtemperature Shutoff- Standard on all units. A manual reset... [See More]

  • Phase: Single Phase AC Voltage
  • AC Voltage Required: 120 to 480
  • Maximum Operating (Sheath) Temperature: 212
  • Watts: 1.00 to 8.00
Immersion Heater - Over-the-side - Fluoropolymer Covered Heater -- GXFL
from Chromalox

L-Shaped. Fluoropolymer Covered Stainless Steel Elements. 10 W/in ². 1 - 6 kW. 120, 240 and 480 Volt, Single Phase. Moisture/Corrosion Resistant Terminal Enclosure. Third-party certifications: UL Listed, CSA, CE [See More]

  • Phase: Single Phase AC Voltage
  • AC Voltage Required: 120 to 480
  • Maximum Operating (Sheath) Temperature: 180 to 219
  • Watts: 1.00 to 6.00
Fluoropolymer 3 Phase Over the Side Heater -- 3HX Style
from Process Technology

Excellent chemical resistance to aggressive acids. FEATURES. PTFE sleeved 304 stainless elements inert to most solutions up to 212 °F (100 °C). Low watt density design 10 watts/square inch (1.5w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m)... [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • AC Voltage Required: 120 to 600
  • Maximum Operating (Sheath) Temperature: 212
  • Watts: 1.00 to 6.00
Over-the-side Immersion Heater -- TL & KTL
from OMEGA Engineering, Inc.

Lightweight, portable, easy to install L-shape construction, puts the heat at the bottom of the tank and the terminal enclosure at the top of the tank. These heaters are convenient answers for many immersion heating applications. Capacities, dimensions and sheaths fit a wide range of heating... [See More]

  • Phase: Single Phase AC Voltage
  • Insertion Length: 36 to 48
  • Watt Density: 20 to 40
  • Applications: Clean Water Heating
Immersion Heater - Over-the-side - L-Shaped Metal Heater -- TLI
from Chromalox

INCOLOY ® Sheath Elements W/In ²). Stainless Steel Riser (36 and 48"). 120, 240 and 480 Volt, 1 and 3 Phase. Moisture Resistant Terminal Enclosure. For Corrosive Fluids. 2 Element 2 - 12 kW. 3 Element 3 - 18 kW. Third-party certifications: UL Listed, CSA [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • Watts: 2.00 to 18.00
  • AC Voltage Required: 120 to 480
  • Watt Density: 40
Fluoropolymer Low Profile Over the Side Single Phase Heater -- HXF Style
from Process Technology

Excellent chemical resistance to aggressive acids. FEATURES. PTFE sleeved 304 stainless elements inert to most solutions up to 212 °F (100 °C). Low watt density design 10 watts/square inch (1.5w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m)... [See More]

  • Phase: Single Phase AC Voltage
  • AC Voltage Required: 120 to 600
  • Maximum Operating (Sheath) Temperature: 212
  • Watts: 0.50 to 6.00
Over-the-side Immersion Heater -- TLC and KTLC
from OMEGA Engineering, Inc.

These heaters are lightweight and portable and provide convenient solutions to many heating applications. TLC Series heaters have two or three straight heating elements, while KTLC Series heaters have two or three curved heating elements. [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • Watts: 2.00 to 18.00
  • AC Voltage Required: 120 to 480
  • Watt Density: 40
Immersion Heater - Over-the-side - L-Shaped Metal Sheath Heater -- KTLC
from Chromalox

Copper Sheath Elements (40 W/In ²). 304 SS Riser. 120, 240 and 480V, 1 and 3 Phase. Moisture Resistant Terminal Enclosure. For Clean Water. 2 Element 2 - 12 kW. 3 Element 3 - 18 kW. Third-party certifications: UL Listed, CSA [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • Watts: 2.00 to 18.00
  • AC Voltage Required: 120 to 480
  • Sleeve (Sheath) Material: Copper
Fluoropolymer Open Fluid Path Single Phase Heater -- HXO Style
from Process Technology

Excellent chemical resistance to aggressive acids. FEATURES. PTFE sleeved 304 stainless elements inert to most solutions up to 212 °F (100 °C). Low watt density design 10 watts/square inch (1.5w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m)... [See More]

  • Phase: Single Phase AC Voltage
  • AC Voltage Required: 120 to 600
  • Maximum Operating (Sheath) Temperature: 212
  • Watts: 0.50 to 9.00
Over-the-side Immersion Heaters -- KBLC & KBLS
from OMEGA Engineering, Inc.

Light weight and easy to use. Heater is set atop the mass and then melts its way to the bottom. Steel terminal housing protected by acid and heat resistant paint. Standard with built-in controls on most models. [See More]

  • Phase: Single Phase AC Voltage
  • Watts: 2.20 to 4.40
  • AC Voltage Required: 240
  • Watt Density: 11
Immersion Heater - Over-the-side - L-Shaped Metal Sheath Heater -- KTLI
from Chromalox

INCOLOY ® Sheath Elements (40W/In ²). Stainless Steel Riser (36 and 48"). 120, 240 and 480 Volt, 1 and 3 Phase. Moisture Resistant Terminal Enclosure. For Corrosive Fluids. 2 Element 2 - 12 kW. 3 Element 3 - 18 kW. Third-party certifications: UL Listed, CSA [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • Watts: 2.00 to 18.00
  • AC Voltage Required: 120 to 480
  • Watt Density: 40
Fluoropolymer Spiral Over the Side Single Phase Heater -- HX Style
from Process Technology

Excellent chemical resistance to aggressive acids. FEATURES. PTFE sleeved 304 stainless elements inert to most solutions up to 212 °F (100 °C). Low watt density design 10 watts/square inch (1.5w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m)... [See More]

  • Phase: Single Phase AC Voltage
  • AC Voltage Required: 120 to 600
  • Maximum Operating (Sheath) Temperature: 212
  • Watts: 0.50 to 9.00
Immersion Heater - Over-the-side - L-Shaped Metal Sheath Heater -- KTLO
from Chromalox

Steel Sheath Elements (20 W/In ²). Steel Riser (36 and 48"). 120, 240 and 480V, 1 and 3 Phase. Moisture Resistant terminal Enclosure. For Medium Weight Oils & Degreasing Solutions. 2 Element 2 - 7 kW. 3 Element 3 - 10 kW. Third-party certifications: UL Listed, CSA [See More]

  • Phase: Single Phase AC Voltage; Three Phase AC Voltage
  • Watts: 2.00 to 10.00
  • AC Voltage Required: 120 to 480
  • Watt Density: 20