Stainless Steel Over-the-Side Heaters
from WATTCO
Over the Side Heaters are a popular industrial heating product for economic and practical uses. Using a water-resistant terminal housing, these industrial heaters come in many shapes and sizes to fit within your tank dimensions and specifications. Wattco over the side immersion heaters are custom... [See More]
- Sleeve (Sheath) Material: Nickel Alloy; Stainless Steel; Steel; Titanium
- AC Voltage Required: 208 to 600
- Phase: Single Phase AC Voltage; Three Phase AC Voltage
- Watt Density: 14 to 60
from Tempco Electric Heater Corporation
Typical Applications. For plating tanks, rinse tanks and other non-sludging aqueous solutions. T1 thermal fuse protection standard; T2 bi-metal switch optional. Grounded for safety. Vapor-tight polypropylene terminal enclosure. Standard 3-ft. flexible PVC liquid-tight conduit. 240, 480 volts... [See More]
- Sleeve (Sheath) Material: Stainless Steel; Steel; Titanium
- Phase: Single Phase AC Voltage; Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 180 to 300
- AC Voltage Required: 240 to 480
from Tempco Electric Heater Corporation
Typical Applications. For plating tanks, rinse tanks and other non-sludging aqueous solutions. T1 thermal fuse protection standard; T2 bi-metal switch optional. Grounded for safety. Vapor-tight polypropylene terminal enclosure. Standard 3-ft. flexible PVC liquid-tight conduit. 120, 240, 480 volts... [See More]
- Sleeve (Sheath) Material: Stainless Steel; Steel; Titanium
- Phase: Single Phase AC Voltage; Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 180 to 300
- AC Voltage Required: 120 to 480
from Tempco Electric Heater Corporation
Typical Applications. For plating tanks, rinse tanks and other acidic aqueous solutions. T1 thermal fuse protection standard; T2 bi-metal switch optional. Grounded for safety. Vapor-tight polypropylene terminal enclosure with universal mounting flange. Standard 3-ft. flexible PVC liquid-tight... [See More]
- Sleeve (Sheath) Material: Stainless Steel; Steel; Titanium
- Phase: Single Phase AC Voltage; Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 180 to 300
- AC Voltage Required: 120 to 480
from Tempco Electric Heater Corporation
Typical Applications. For plating tanks, rinse tanks and other non-sludging aqueous solutions. T1 thermal fuse protection standard; T2 bi-metal switch optional. Grounded for safety. Vapor-tight polypropylene terminal enclosure. Standard 3-ft. flexible PVC liquid-tight conduit. 240, 480 volts... [See More]
- Sleeve (Sheath) Material: Stainless Steel; Steel; Titanium
- Phase: Single Phase AC Voltage; Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 180 to 300
- AC Voltage Required: 240 to 480
from Tempco Electric Heater Corporation
Typical Applications. For plating tanks, phosphatizing and concentrated aqueous solutions. T1 thermal fuse protection standard; T2 bi-metal switch optional. Grounded for safety. Vapor-tight polypropylene terminal enclosure with universal mounting flange. Standard 3-ft. flexible PVC liquid-tight... [See More]
- Sleeve (Sheath) Material: Stainless Steel; Steel; Titanium
- Phase: Single Phase AC Voltage; Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 180 to 300
- AC Voltage Required: 120 to 480
from Tempco Electric Heater Corporation
General Purpose Over-the-Side Immersion Heaters, Vertical Loop Low-Profile Immersion Heaters, Sanitzing Sink Immersion Heaters and Deep Tank/Sump Immersion Heaters are manufactured with Incoloy ®, Stainless Steel, Steel or Copper heating elements and NEMA 4 Terminal Housings. [See More]
- Sleeve (Sheath) Material: Stainless Steel
- AC Voltage Required: 240 to 480
- Phase: Single Phase AC Voltage (optional feature); Three Phase AC Voltage
- Watts: 3.00 to 18.00
from Process Technology
Durable, efficient chemical heater. FEATURES. Heavy wall metal sheaths available in steel, 304 stainless steel, 316 stainless steel and titanium. Low watt densities of 18 watts/square inch (2.8 w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible... [See More]
- Sleeve (Sheath) Material: Stainless Steel; Steel; Titanium
- Phase: Single Phase AC Voltage; Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 180
- AC Voltage Required: 120 to 600
from OMEGA Engineering, Inc.
Tubular heating elements are brazed into a junction box. All wetted parts of TLO & KTLO Series heaters are steel. Sludge legs (to keep heated portion of the unit off the bottom of the tank) are standard. [See More]
- Sleeve (Sheath) Material: Stainless Steel
- AC Voltage Required: 120 to 480
- Phase: Single Phase AC Voltage; Three Phase AC Voltage
- Watts: 2.00 to 10.00
from Chromalox
Side Mount. Fluoropolymer Covered Stainless Steel Elements. 10 W/in ². 1 - 6 kW. 120, 240 and 480 Volt, Single Phase. Moisture Resistant Terminal Enclosure. Third-party certifications: UL Listed, cUL [See More]
- Sleeve (Sheath) Material: Stainless Steel; Fluoropolymer Covered
- Phase: Single Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 180 to 219
- AC Voltage Required: 120 to 480
from Process Technology
Customer designed specifically for phosphate coating applications. FEATURES. For use in iron, zinc and manganese phosphate tanks. Schedule 40, heavy wall, 316 stainless steel sheath withstands scaling better than traditional heaters. Low watt densities up to 23 watts/square inch (3.5 w/cm ²)... [See More]
- Sleeve (Sheath) Material: Stainless Steel
- Phase: Single Phase AC Voltage; Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 230
- AC Voltage Required: 120 to 600
from OMEGA Engineering, Inc.
e PTH series models are heavy duty general purpose heaters for heating plating tanks, rinse tanks and other aqueous solutions. The Type 316 Stainless Steel is passivated to provide additional corrosion resistance. These heaters are equipped with a vapor tight terminal enclosure and a 3 foot long... [See More]
- Sleeve (Sheath) Material: Stainless Steel
- AC Voltage Required: 120 to 480
- Phase: Single Phase AC Voltage
- Watts: 5.00 to 7.50
from Chromalox
L-Shaped. Fluoropolymer Covered Stainless Steel Elements. 10 W/in ². 1 - 6 kW. 120, 240 and 480 Volt, Single Phase. Moisture Resistant Terminal Enclosure. Third-party certifications: UL Listed, cUL [See More]
- Sleeve (Sheath) Material: Stainless Steel; Fluoropolymer Covered
- Phase: Single Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 180 to 219
- AC Voltage Required: 120 to 480
from Process Technology
Durable, efficient chemical heater. FEATURES. Heavy wall metal sheaths available in steel, 304 stainless steel, 316 stainless steel and titanium. Watt densities up to 40 watts/square inch (6.2 w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible... [See More]
- Sleeve (Sheath) Material: Stainless Steel
- Phase: Single Phase AC Voltage (optional feature); Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 180
- AC Voltage Required: 200 to 600
from OMEGA Engineering, Inc.
These over-the -side immersion heaters are designed for installing in the top of a tank with the heated portion directly immersed along the side or at the bottom. This provides easy removal of the heater and ample working space inside the tank. [See More]
- Sleeve (Sheath) Material: Stainless Steel
- AC Voltage Required: 120 to 480
- Phase: Single Phase AC Voltage; Three Phase AC Voltage
- Watts: 2.00 to 18.00
from Chromalox
Side Mount. Fluoropolymer Covered Stainless Steel Elements. 10 W/in ². Third-party certifications: UL Listed, CSA, CE. 1 - 6 kW. 120, 240 and 480 Volt, Single Phase. Moisture/Corrosion Resistant Terminal Enclosure. Third-party certifications: UL Listed, CSA, CE [See More]
- Sleeve (Sheath) Material: Stainless Steel; Fluoropolymer Covered
- Phase: Single Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 180 to 219
- AC Voltage Required: 120 to 480
from Process Technology
Durable, efficient chemical heater. FEATURES. Heavy wall metal sheaths available in steel, 304 stainless steel, 316 stainless steel and titanium. Watt densities up to 35 watts/square inch (5.4 w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible... [See More]
- Sleeve (Sheath) Material: Stainless Steel; Titanium
- Phase: Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 180
- AC Voltage Required: 240 to 600
from OMEGA Engineering, Inc.
1. Corrosion Resistan- Thermoplastic fluoropolymer coated stainless steel sheath for long life in almost all types of corrosive solutions for operating temperatures up to 212F. Pin hole free, durable coating, 100% tested at factory. 2. Overtemperature Shutoff- Standard on all units. A manual reset... [See More]
- Sleeve (Sheath) Material: Stainless Steel
- Phase: Single Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 212
- AC Voltage Required: 120 to 480
from Chromalox
L-Shaped. Fluoropolymer Covered Stainless Steel Elements. 10 W/in ². 1 - 6 kW. 120, 240 and 480 Volt, Single Phase. Moisture/Corrosion Resistant Terminal Enclosure. Third-party certifications: UL Listed, CSA, CE [See More]
- Sleeve (Sheath) Material: Stainless Steel; Fluoropolymer Covered
- Phase: Single Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 180 to 219
- AC Voltage Required: 120 to 480
from Process Technology
Durable, efficient chemical heater. FEATURES. Heavy wall metal sheaths available in 316 stainless steel. Watt densities up to 40 watts/square inch (6.2 w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit. Grounded... [See More]
- Sleeve (Sheath) Material: Stainless Steel
- Phase: Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 180
- AC Voltage Required: 200 to 600
from Chromalox
Fluoropolymer Covered Stainless Steel Elements. 10 W/in ². 3 - 18 kW. 240 and 480 Volt, Three Phase. Moisture Resistant Terminal Enclosure. Third-party certifications: UL Listed, cUL [See More]
- Sleeve (Sheath) Material: Stainless Steel; Fluoropolymer Covered
- Phase: Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 180 to 219
- AC Voltage Required: 240 to 480
from Process Technology
Quick plug in system for aquaculture applications. 316 stainless steel for fresh water or titanium for salt water applications. Watt densities up to 40 watts/square inch (6.5 w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 8.5 flexible cord/plug. P1 thermal... [See More]
- Sleeve (Sheath) Material: Stainless Steel; Titanium
- AC Voltage Required: 100 to 480
- Phase: Single Phase AC Voltage; Three Phase AC Voltage (optional feature)
- Watts: 1.00 to 5.60
from Chromalox
Stainless Steel Sheath Elements (40 W/In ²). Stainless Steel Riser (36 and 48"). 120, 240 and 480V, 1 and 3 Phase. Moisture Resistant Terminal Enclosure. For Mildly Corrosive Fluids. 2 Element 2 - 12 kW. 3 Element 3 - 18 kW. Third-party certifications: UL Listed, CSA [See More]
- Sleeve (Sheath) Material: Stainless Steel
- AC Voltage Required: 120 to 480
- Phase: Single Phase AC Voltage; Three Phase AC Voltage
- Watts: 2.00 to 18.00
from Process Technology
Durable, efficient chemical heater. FEATURES. Heavy wall metal sheaths available in steel, 304 stainless steel, 316 stainless steel and titanium. Low watt densities of 18 watts/square inch (2.8 w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible... [See More]
- Sleeve (Sheath) Material: Stainless Steel; Steel; Titanium
- Phase: Single Phase AC Voltage; Three Phase AC Voltage (optional feature)
- Maximum Operating (Sheath) Temperature: 180
- AC Voltage Required: 120 to 600
from Chromalox
Stainless Steel Sheath Elements (40 W/In ²). Stainless Steel Riser (36 and 48"). 120, 240 and 480V, 1 and 3 Phase. Moisture Resistant Terminal Enclosure. For Mildly Corrosive Fluids. 2 Element 2 - 12 kW. 3 Element 3 - 18 kW. Third-party certifications: UL Listed, CSA [See More]
- Sleeve (Sheath) Material: Stainless Steel
- AC Voltage Required: 120 to 480
- Phase: Single Phase AC Voltage; Three Phase AC Voltage
- Watts: 2.00 to 18.00
from Process Technology
Durable, efficient chemical heater. FEATURES. Heavy wall metal sheaths available in steel, 304 stainless steel, 316 stainless steel and titanium. Low watt densities of 18 watts/square inch (2.8 w/cm ²). Vapor resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible... [See More]
- Sleeve (Sheath) Material: Stainless Steel; Titanium
- Phase: Single Phase AC Voltage; Three Phase AC Voltage
- Maximum Operating (Sheath) Temperature: 180
- AC Voltage Required: 120 to 600
from Chromalox
Flat Elements. Fluoropolymer Coated Stainless Steel Elements. 20 W/In ². 3 - 10 kW. 240 and 480 Volt, Three Phase. Moisture Resistant Terminal Enclosure. Third-party certifications: UL Listed, CSA [See More]
- Sleeve (Sheath) Material: Stainless Steel; Fluoropolymer Covered
- AC Voltage Required: 240 to 480
- Phase: Three Phase AC Voltage
- Watts: 3.00 to 10.00
from Process Technology
Designed for safety and low maintenance. FEATURES. Automatic temperature protection is built in. Won't burn out due to air or scale exposure. 316 stainless steel for fresh water or titanium for salt water applications. Available in Over the Side, L Shaped and Axial Styles. Watt densities up to 40... [See More]
- Sleeve (Sheath) Material: Stainless Steel; Titanium
- AC Voltage Required: 100 to 240
- Phase: Single Phase AC Voltage
- Watts: 1.00 to 1.70
from Chromalox
Round Cross Section Elements. Fluoropolymer Coated Stainless Steel Elements. 20 W/In ². 1 - 8 kW. 120, 240 and 480 Volt, Single Phase. Moisture Resistant Terminal Enclosure. Third-party certifications: UL Listed, CSA [See More]
- Sleeve (Sheath) Material: Stainless Steel; Fluoropolymer Covered
- AC Voltage Required: 120 to 480
- Phase: Single Phase AC Voltage
- Watts: 1.00 to 8.00