Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Supplier: PMC Engineering LLC
Description: . 0.1% & 0.25% accuracy 3/4" diameter welded Titanium 4-20 mA, 2 wire output Molded polyurethane cable Applications Ground Water Landfill and Remediation Dams and Rivers Shipboard Ballast Tanks Oceanographic Mapping Tsunami Early Warning Systems
- Features: Submersible
- Level Measurement Type: Continuous Level
- Material Temperature Range: -10 to 175 F
- Maximum Operating Pressure: 300 psi
-
Supplier: PCB Piezotronics, Inc.
Description: 4-20MA SENSOR
- Device Type: Sensor / Transducer, Transmitter
- Linear Velocity: 0.0 in/sec
- Sensor Mounting: Stud or Bolt-on
-
Supplier: PMC Engineering LLC
Description: SS or Titanium 4-20 mA, 2 wire output Molded polyurethane Applications Surface and Run-Off Water Process Plant Water Run-Off Monitoring Sewage Lift Stations – Ceramic Clog-Free Paper Making Machine
- Device Classification: Sensor-Only, Transmitter
- Level Measurement Type: Continuous Level
- Material Temperature Range: -10 to 175 F
- Maximum Operating Pressure: 150 psi
-
-
Supplier: PMC Engineering LLC
Description: The ATM/N series is part of a comprehensive range of pressure transmitters specifically designed for the long term monitoring of ground water and waste water. This series 24 provides a 4 to 20 mA Output. Features such as Kevlar strengthened cable, titanium, ballast
- Device Classification: Sensor-Only, Transmitter
- Level Measurement Type: Continuous Level
- Material Temperature Range: 25 to 175 F
- Maximum Operating Pressure: 360 psi
-
Supplier: PMC Engineering LLC
Description: The ATM.ECO/N series submersible is part of a comprehensive range of pressure transmitters specifically designed for the long term monitoring of ground water and waste water. This ECO series provides a 4 to 20 mA Output. Features such as Kevlar strengthened cable,
- Device Classification: Sensor-Only, Transmitter
- Level Measurement Type: Continuous Level
- Material Temperature Range: 25 to 175 F
- Maximum Operating Pressure: 360 psi
-
Supplier: FPI Sensors International
Description: Continuous level sensors provide continuous feedback and are available in both 0-5VDC and 4-20 ma outputs. Several options are available including temperature sensors, independent low or high level switch points, a variety of materials and mounting options. If you
- Material Temperature Range: 250 F
- Maximum Operating Pressure: 500 psi
- Measuring Range: 4 to 96 inch
- Media Type: Liquid
-
Sensor Transmitters - Javelin 2-Wire Isolated Transmitter, Universal Input, 4-20mA Output -- JavelinSupplier: Define Instruments
Description: What it does: The Javelin accepts one of several popular input signal types and outputs a 4-20mA signal. Input types: RTD, mA, V, Pot, TC The Javelin is a loop powered, isolated transmitter. One of its key features is its easy software setup using Define ToolBox.
- Features: Voltage Excitation Supply
- Form Factor: DIN Rail
- Inputs / Channels: 1 #
- Operating Temperature: -4 to 131 F
-
Supplier: PCB Piezotronics, Inc.
Description: Industrial vibration sensor, 4 to 20 mA output, 0 to 2.0 in/sec pk, 3 to 1k Hz, top exit, terminal block
- Device Type: Sensor / Transducer, Transmitter
- Linear Velocity: 0.0 in/sec
- Sensor Mounting: Stud or Bolt-on
-
Supplier: PCB Piezotronics, Inc.
Description: Industrial vibration sensor, 4 to 20 mA output, 0 to 2.0 in/sec pk, 3 to 1k Hz, top exit, 10-ft integral cable
- Device Type: Sensor / Transducer, Transmitter
- Linear Velocity: 0.0 in/sec
- Sensor Mounting: Stud or Bolt-on
-
Supplier: PCB Piezotronics, Inc.
Description: Industrial vibration sensor, 4 to 20 mA output, 0 to 1 in/sec RMS, 10 to 1k Hz, side exit, 2-pin conn.
- Device Type: Sensor / Transducer, Transmitter
- Linear Velocity: 0.0 in/sec
- Sensor Mounting: Stud or Bolt-on
-
Supplier: Define Instruments
Description: What it does: The TM-4DPI accepts one of several input signal types and generates one of four commonly required outputs: 4-20mA, 0-20mA, 0-10V, &plusm;10V. The TM-4DPI is designed for applications that have an auxiliary supply to power the
- Features: Voltage Excitation Supply
- Form Factor: DIN Rail
- Operating Temperature: -4 to 185 F
- Outputs: Current Loop (e.g., 4-20 mA), Voltage
-
Supplier: Burkert Fluid Control Systems
Description: holder previously mounted on a wall, and it must be associated with a remote temperature sensor. The switching points can be programmed with keys directly in the display or optionally with a 4...20 mA standard signal input from an external PLC. As an option, the process value
- Digital or Analog Display: Yes
- Output: Analog Current (e.g., 4-20 mA), Relay / Switch Output
- Reference Material: Platinum
- Reference Resistance: 100 Ohms
-
Supplier: PR electronics
Description: be programmed for voltage in the range -40...100 mVDC. The digital signal can be selected as either NPN or PNP. Taring can either be by way of the digital input or from the front interface. The analog output can be programmed to current in the range 0...20 mA or voltage in the
- Operating Temperature: -4 to 140 F
- Outputs: Current Loop (e.g., 4-20 mA), Voltage
- Signal Inputs: DC Voltage
-
Supplier: PR electronics
Description: configuration tool included in the PReset software has been developed specifically for the configuration of level applications. Among other things, it contains a function for "on line" measurement of input span as well as a linearization function for volume linear output from horizontal
- Operating Temperature: -40 to 185 F
- Outputs: Current Loop (e.g., 4-20 mA)
-
Supplier: PR electronics
Description: Application Conversion of resistance variation to standard analog current signals, e.g. from Ohmic level sensors or valve positions. User-defined linearization function can be activated. Technical characteristics Within a few seconds the user can program PR5343B to measure
- Operating Temperature: -40 to 185 F
- Outputs: Current Loop (e.g., 4-20 mA)
-
Supplier: Define Instruments
Description: This versatile 2-wire transmitter accepts a range of standard input types, and outputs a 4-20mA loop. USB programming is hassle free, and takes less than a minute using Define ToolBox. 2-wire universal transmitter (DIN-mount, isolated) Current, voltage,
- Features: Voltage Excitation Supply
- Form Factor: DIN Rail
- Operating Temperature: -4 to 185 F
- Sensor Inputs: Thermocouple, Thermistor, RTD
-
Supplier: PR electronics
Description: Advanced features The 5114 transmitter can be configured, with or without a power supply, using the PReset software and the Loop Link communications unit. Application Jumper selectable inputs for current/voltage or temperature. Programmable current (0...100 mA) and voltage (0
- Form Factor: DIN Rail
- Operating Temperature: -4 to 140 F
- Outputs: Current Loop (e.g., 4-20 mA), Voltage
- Sensor Inputs: Thermocouple, RTD
-
Supplier: Piezo-Metrics
Description: displays, analog outputs and base stations etc. Although this OEM wireless current (4-20 mA) sensor transmitter T24-IA can be used ‘as is’ for OEM solutions there are a number of enclosure options available. See ‘Related Products’ tab. The module is configured and
- Operating Temperature: -4 to 131 F
- Signal Inputs: DC Current
-
Supplier: Hayward Flow Control
Description: Dual, assignable 4-20mA outputs Dual 5A, 250 V programmable relays Dual programmable open collector outputs Mounting hardware included Hayward 2-year warranty
- Form Factor: DIN Rail
- Inputs / Channels: 2 #
- Operating Temperature: 4 to 122 F
- Outputs: Current Loop (e.g., 4-20 mA), Relay
-
Supplier: Instrumentation Northwest, Inc.
Description: Only slightly over 7" long, this rugged industry standard 4-20 mA pressure transmitter is great almost anywhere you need to measure pressure or level, whether it be in a lake, in a tank, or in a well. A 4-20 mA output device, the sensor measures up to
-
Supplier: tecsis LP
Description: Model XPI is a standard, industrially rugged pressure transducer available with mV/V, 0-5 V or 4-20 mA output. This medium range pressure sensor covers ranges from 0-25 to 0-10,000 psi and delivers ±0.15% linearity. Robust design, welded stainless steel construction, and
- Electrical Output: Analog Current
- Features: Temperature Compensation
- Media: Liquid, Gas
- Operating Temperature: -50 to 250 F
-
Supplier: Transcat, Inc.
Description: Product Highlights Humidity Range : 3% to 95% RH Humidity Accuracy : ± 2% Temperature Range : -20 °C to 75 °C Temperature Accuracy : ± 0.6°C Input : 6 V to 30 V DC supply Temperature and RH output : 4 mA to 20 mA Built-in sensor Small size One year
- Sensed Temperature: -4 to 167 F
-
Supplier: Electronic Sensors, Inc.
Description: , enabling the user to measure from the very top of the tank. The automatic profiling (tank mapping) eliminates interfering signals from agitators and other obstructions in the vessel without the need to empty the vessel. The level measurement output is a 4-20 mA current signal.
- Device Classification: Sensor-Only
- Meter Technology: Ultrasonic / Sonic
- Output Options: Analog Current Signal (e.g., 4-20 mA)
-
Supplier: Global Detection Systems Corp.
Description: The GDS-49 is a two-wire loop-powered 4-20mA sensor transmitter designed to detect a wide range of toxic gases at ppm levels. The current loop output is compatible with the C1 Protector, C2 Protector, C2 Quad Protector or C64 Protector Controllers, the GASMAX II or
- Electrical Outputs: Analog Current
- Features: Hazardous Environments, Intrinsically Safe
- General Gas Types: Toxic Gas, Combustible Gas
- Measurement Type: %LEL, Trace
-
Supplier: RainWise, Inc.
Description: Features 4-20mA or 0-5V outputs. DIN rail mountable. DIP switch configuration. 1",5" or 10" ranges. optically isolated inputs. 24V reset input. 5 year warranty.
- Form Factor: DIN Rail
- Outputs: Current Loop (e.g., 4-20 mA), Voltage
- User Interface: None
-
Supplier: OMEGA Engineering, Inc.
Description: feature an encapsulated micro miniature signal conditioner built into a sealed connector housing. The signal conditioner converts the resistive change of a 100 O, 0.00385 RTD probe or sensor into an industry-standard 2-wire, 4 to 20 mA analog output across a
- Operating Temperature: -40 to 185 F
- Output: Analog Current (e.g., 4-20 mA)
- Reference Material: Platinum
- Reference Resistance: 100 Ohms
-
Supplier: ifm electronic gmbh
Description: Immediate notification of deviations in accuracy Improved quality assurance in between calibration intervals Robust design for permanently precise measurements even in demanding environments Transparent sensor monitoring thanks to logging of the diagnostic values Simulation function
- Operating Temperature: -13 to 158 F
- Output: Analog Current (e.g., 4-20 mA), Relay / Switch Output
- Reference Material: Platinum
- Reference Resistance: 1000 Ohms
-
Supplier: Automation24, Inc.
Description: The iTEMP TMT188 temperature head transmitter from Endress+Hauser is designed for transformation of a TC thermocouple sensor signal into a fixed range of measurement. The standardised output signal used for the process measurement is a 4 to 20 mA signal.
- Output: Analog Current (e.g., 4-20 mA)
- Sensed Temperature: -454 to 4523 F
-
Supplier: Laurel Electronics LLC
Description: . The Laureate 4-20 mA, 0-20 mA, 0-10V or -10V to +10V and RS232/RS485 output transmitter for resistance in ohms offers the same high performance, signal conditioning and programmable features as Laureate digital panel meters, counters & timers provides six
- Form Factor: DIN Rail
- Operating Temperature: -40 to 158 F
- Outputs: Current Loop (e.g., 4-20 mA), Voltage
-
Supplier: Wilcoxon Sensing Technologies
Description: Intrinsically Safe 4-20 mA vibration sensor, 85°C; 2.0 ips full scale, output proportional to velocity, peak; top exit 2-pin MIL-C-5015 connector, 1/4-28 mounting hole (stud included)
- Features: Intrinsically Safe
- Frequency Range: 4 to 2000 Hz
- Linear Velocity: 2 in/sec
- Operating Temperature: -40 to 185 F
-
Supplier: KOBOLD Instruments, Inc.
Description: class B resistive temperature detector (RTD) combined with an integrated loop powered 4-20 mA output transmitter. Optional digital indicator, model AUF, plugs directly to the Hirschmann (DIN 43650) plug. This sensor is rugged and all 316 SS construction. Fittings,
- Output: Analog Current (e.g., 4-20 mA)
- Reference Material: Platinum
- Reference Resistance: 100 Ohms
- Sensed Temperature: -328 to 1112 F
-
Supplier: Delta Controls Ltd.
Description: The FCX-AII differential pressure (flow) transmitter accurately measures differential pressure, liquid level, gauge pressure or flow rate and transmits a proportional 4 to 20mA signal. The transmitter utilizes a unique micro-machined capacitance silicon
- Device Classification: Transmitter
-
Supplier: FineTek
Description: , which is then amplified to create a variable 4-20mA output that varies as a result of the changing liquid level. In addition, a pressure transducer is available for measuring pressure in tanks or pipes and producing a variable 4-20mA output. ?Completely
- Features: Submersible
- Measuring Range: 3936 inch
- Media Type: Liquid
- Meter Technology: Pressure Membrane
-
Supplier: Alfa Laval Inc.
Description: measurement. Temperature transmitters cover a measuring range between -20 and 150 °C (-4°F and 302°F). The sensor tip design ensures fast response times and accurate measurements. Hygienic temperature transmission Compact in design, Alfa Laval temperature
- Digital or Analog Display: Yes
- Local Interface: Computer Interface
- Operating Temperature: -7.6 to 349 F
- Output: Analog Current (e.g., 4-20 mA), Relay / Switch Output
-
Supplier: OMEGA Engineering, Inc.
Description: used with OMEGA's intrinsic safety barriers and when properly powered. The LVR30 Series is provided with a signal conditioner to provide a 4-20 mA output when powered by 10-30 Vdc. The LVR30 Series cannot be made intrinsically safe. All LVR30 units are supplied with a J-box with
- Level Measurement Type: Continuous Level
- Material Temperature Range: -40 to 230 F
- Maximum Operating Pressure: 300 psi
- Media Type: Liquid
Find Suppliers by Category Top
Featured Products Top
-
Dataforth's 4 20mA Transmitters are "Best of Breed" accuracy, linearity, stability and noise specifications. These transmitters are designed to provide outstanding protection and isolation performance for (read more)
Browse Data Acquisition Systems and Instruments Datasheets for Dataforth Corporation -
The 2880-LT uses HF capacitance technology — no moving parts, no routine cleaning. Probe-mounted electronics with 4-20 mA output. 2880-LT Probe Mounted Transmitter The 2880-LT provides reliable monitoring of (read more)
Browse Level Sensors Datasheets for Arjay Engineering -
and Process Temperature. The QVT will output a 4-20 mA signal corresponding to Differential Pressure or Flow. Specifications Modes of Operation: Multivariable or DP Only Operating Range: 10000:1 (0.0009 in WC to 9 in WC (read more)
Browse Air Flow Sensors Datasheets for Eastern Instruments -
°C (± 3.4 °F). The output is configurable to display in °C dewpoint, °F dewpoint, ppm(v), ppb(v), g/m3 and lb/MMSCF. Incorporating the unique AutoCal function, designed by Shaw Moisture (read more)
Browse Humidity Transmitters Datasheets for Shaw Moisture Meters -
Fargo Controls Inc.'s analog output inductive proximity sensors give a 0-10Vdc and/or a 4-20mA output based upon the distance between a metal target and the sensor. They do this with extended operating distances and are (read more)
Browse Inductive Proximity Sensors Datasheets for Fargo Controls, Inc. -
voltage to 2.5 kV Flexibility: input and output ranges selectable by DIP and rotary encoder switches for infrared interface (IrDA) ±0-5V, 0-20mA, 0-10V, 4-20 mA outputs Customer-specific input/ output settings possible Examples of focus industries include (read more)
Browse RTD Temperature Transmitters Datasheets for Knick Interface LLC -
The SDT-Ex is a reliable, accurate dewpoint transmitter suitable for continuous measurement of trace moisture in industrial process gases. This compact, 3 wire, 4-20 mA, loop powered device is certified intrinsically safe to (read more)
Browse Hygrometers and Humidity Measurement Instruments Datasheets for Shaw Moisture Meters -
specifications Measurement type: Dewpoint or moisture content in gases Analogue output: 2?wire, 24?V, 4–20?mA Digital output: 4?wire Modbus RTU Serial Line RS485 Sensor technology: SHAW ultra?high?capacitance aluminium oxide Accuracy (read more)
Browse Hygrometers and Humidity Measurement Instruments Datasheets for Shaw Moisture Meters -
used standalone, auto-configured to our SCX Controller or any other device that receives MODBUS or 4-20mA outputs. (read more)
Browse Gas Transmitters Datasheets for Safeguard Analytics -
supply current to represent the input signal within a 4-to-20mA range. As DSCTs operate from signal loop current, only low-cost, twisted-pair wiring is needed, making these two-wire transmission loops an economical way to connect sensors and distant measuring equipment. (read more)
Browse Signal Conditioners Datasheets for Dataforth Corporation
Conduct Research Top
-
Did You Know? Carbon Monoxide Sensors Do Not Detect Diesel Exhaust?
loading docks. In this application, the presence of carbon monoxide will cause the outside air dampers to close and remain closed until the outside air is free of fumes. Kele now offers two products that may be used in these applications. The WCO-1B Carbon Monoxide Sensor provides a 4-20 mA output
More Information Top
-
ISA TR84.00.04 PART 2 - Example Implementation of ANSI/ISA-84.00.01-2004
e) The 4 - 20 mA sensor outputs of the transmitters are direct connected to the SIS and parallel wired to the BPCS.
-
http://www.ndt.net/article/wcndt2008/papers/441.pdf
Accelerometer & Transmitter w/Relay 4 - 20 mA Output Vibration Sensor & Transmitter w/Relay .
-
Mock-up experiments on permeability measurement of concrete and construction joints for air tightness assessment
The pressure sensors used were 4 – 20 mA output transmitters with a measure- ment precision of ±0.1 %, which were connected directly to the electrical signal cable and then data acquisition unit.
-
Measurement of Air Tightness Parameter of Lined Rock Caverns For Underground Compressed Air Energy Storage (CAES)
The pressure sensors used are 4 - 20mA output transmitters with a measurement precision of ±0.1 %.
-
GF Piping’s New Metal Magmeter Features Easy Hot Tap Installation Without System Shutdown And Choice Of Three Output Options
These options allow customers the flexibility to connect with other Signet instrumentation via the frequency or digital (S3L) signal output, or use the blind transmitter ( 4 to 20 mA output ) or digital sensor interface for long distance signal transmission application requirements.
-
GF Piping Systems To Showcase 2552 Metal Magmeter At ACE08
These options allow customers the flexibility to connect with other Signet instrumentation via the frequency or digital (S3L) signal output, or use the blind transmitter ( 4 to 20 mA output ) or digital sensor interface for long distance signal transmission application requirements.
-
Monitoring Reciprocating Gas Compressors with 4-20 mA LPS Vibration Sensors
The gray (middle) line illustrates the r.m.s. output from a 4 - 20 mA sensor or transmitter .
-
Control system design guide
So, if calibration is performed using a 4-20 mA generator, you have verified that the control system will interpret the 4-20mA correctly, but you are relying on the 4 - 20 mA transmitter to interpret the sensor output correctly.
-
Multi-sensor Embedded System for Agro-Industrial Applications
The developed module is interfaced with temperature sensors through transmitters giving 4 to 20 mA current outputs .
-
Gear Flow Sensor Transmitter Accessory Flow Monitor w 4 20 mA Output from Cole-Parmer
Gear Flow Sensor Transmitter Accessory Flow Monitor w 4 20 mA Output (Representative photo only .
Indicates content that may require registration and/or purchase.