Supplier: Radwell International
Description: DISCONNECT SAFETY SWITCH, SPEEDFAX SERIES, 600 VAC/DC, 60 AMP, 3 POLE, 3 PST CONTACT FORM, TYPE VBII, NON-FUSIBLE, PANEL MOUNT. FREE 2 YEAR RADWELL WARRANTY
- Type: Non-Fusible
-
Supplier: Waytek, Inc.
Description: 672-P01-060-04, 67 Series Red Battery Disconnect with Integrated Manual Reset Breaker, 60A, 32VDC, 2-Position Category: Battery Disconnects Manufacturer: Mechanical Products Continuous Current Rating: 300A Intermittent Rating: Up to 5 minutes @ 500A Standard Amp Rating: 60A
- Current Rating: 60 amps
- Operating Voltage: 32 volts
- Power: DC
-
Supplier: Radwell International
Description: DISCONNECT SWITCH, VISIBLE BLADE, UNIVERSAL MECHANISM, SERIES 1494U, 60 AMP, 600 VAC/DC, 1-3 PHASE, AC. FREE 2 YEAR RADWELL WARRANTY
-
-
Supplier: Radwell International
Description: DISCONTINUED BY MANUFACTURER, AC HVAC DRIVE, 550 SERIES, VERTICAL E-BYPASS WITH DISCONNECT SWITCH, 380-480 VAC, 50/60 HZ,15 AMP, 10 HP, FRAME SIZE R2. FREE 2 YEAR RADWELL WARRANTY
- Continuous Output Current: 15 amps
- Supply Voltage (AC): 480 volts
-
Supplier: Allied Electronics, Inc.
Description: Specifications Ampere Ratings: From 0.5 to 63 Amps 10K Air @ 120/240 VAC; 5K Air @ 480Y/277 VAC DC Ratings (C-Curve Only): 1-Pole — 60 VDC; 2-Pole — 125 VDC Dual Rated for UL 1077 AC and UL 489A for DC Telecom Applications: 1-Pole — 60 VDC
-
Supplier: Allied Electronics, Inc.
Description: Specifications Ampere Ratings: From 0.5 to 63 Amps 10K Air @ 120/240 VAC; 5K Air @ 480Y/277 VAC DC Ratings (C-Curve Only): 1-Pole — 60 VDC; 2-Pole — 125 VDC Dual Rated for UL 1077 AC and UL 489A for DC Telecom Applications: 1-Pole — 60 VDC
-
Supplier: Allied Electronics, Inc.
Description: Specifications Ampere Ratings: From 0.5 to 63 Amps 10K Air @ 120/240 VAC; 5K Air @ 480Y/277 VAC DC Ratings (C-Curve Only): 1-Pole — 60 VDC; 2-Pole — 125 VDC Dual Rated for UL 1077 AC and UL 489A for DC Telecom Applications: 1-Pole — 60 VDC
-
Supplier: Allied Electronics, Inc.
Description: Specifications Ampere Ratings: From 0.5 to 63 Amps 10K Air @ 120/240 VAC; 5K Air @ 480Y/277 VAC DC Ratings (C-Curve Only): 1-Pole — 60 VDC; 2-Pole — 125 VDC Dual Rated for UL 1077 AC and UL 489A for DC Telecom Applications: 1-Pole — 60 VDC
-
Supplier: DuraComm Corporation
Description: Disconnects battery at an adjustable voltage. Disconnect range is 10.5~12 VDC for 12 volt systems; 21~24 VDC for 24 volt systems; and 46~48 VDC for 48 volt systems. Manual battery disconnect switch included.
- DC Output Voltage: 12 to 15 volts
- DC Output Current: 80 amps
- DC Output Power: 1,000.0000000000001 watts
- AC Input Voltage: 90 to 264 volts
-
Supplier: Schaltbau GmbH
Description: With the bi-directional C110B DC contactor, Schaltbau offers an economic solution for the switching of battery voltages of up to 48 volts (80 volts rated insulation voltage). The single-pole NO contactor is available in four sizes: for conventional thermal currents up to 60, 100, 150,
- Maximum Switching Current: 80 to 480 amps
- Maximum DC Switching Voltage: 48 volts
- Operating Temperature: -13 to 104 F
- Type: Electrical Contactor
-
Supplier: Caterpillar Oil & Gas
Description: generator set. Ratings: 292 - 455 ekW (365 - 570 kVA) @ 50 and 60 Hz (1500 and 1800 rpm) meet China Stage II, U.S. EPA Tier 2 equivalent, EU Stage II equivalent emission standards. Product Design Rugged construction designed to withstand harsh oilfield conditions Shipped from the factory
- Wattage: 292 to 455 watts
- Volt-Ampere: 365,000 to 570,000 VA
- Frequency: 50 Hz, 60 Hz
- Fuel Type: Diesel
-
Supplier: Caterpillar Oil & Gas
Description: Anti-vibration mounts (shipped loose) Designed welded base for increased durability (I-beam design) Starting/Charging System 24-volt starting motor 45-amp charging alternator Battery rack Battery disconnect switch Oversized batteries General Paint — Caterpillar yellow except rails and
- Wattage: 910 to 800 watts
- Volt-Ampere: 1,300,000 to 1,000,000 VA
- Frequency: 50 Hz, 60 Hz
- Fuel Type: Diesel
-
Supplier: Caterpillar Oil & Gas
Description: generator set. Ratings: 440 - 545 ekW (550 - 680 kVA) @ 50 and 60 Hz (1500 and 1800 rpm) meet U.S. EPA Tier 2 equivalent, EU Stage II equivalent emission standards. Product Design Rugged construction designed to withstand harsh oilfield conditions Shipped from the factory complete and ready
- Wattage: 440 to 545 watts
- Volt-Ampere: 550,000 to 680,000 VA
- Frequency: 50 Hz, 60 Hz
- Fuel Type: Diesel
-
Supplier: ESAB Welding and Cutting Products
Description: (MIG), FCAW (Flux-Cored), SMAW (Stick), and GTAW (TIG) welding, as well as ACAG (Arc Gouging), and delivers up to 500 Amps @ 60% duty cycle Welds .030-5/64 in. Flux-Cored and Solid wires Great short arc performance with 500 Amps Full range of stick capabilities with excellent
- Duty Cycle: 6 to 1 %
- Output Current Range: 4 to 5 amps
- Output Voltage Range: 36 to 4 volts
- Equipment Type: Complete System
-
Supplier: Larson Electronics LLC
Description: vehicle paint. - Wrap around base seal prevents dirt from entering the base of the light. Includes rubber cord grip. Voltage: 12 Volts DC appropriate for most consumer vehicles, off road vehicles and small boats (24 Volts DC available in the 24 Volt Golight Light Category) Lamp
-
Supplier: Larson Electronics LLC
Description: working beam Amp Draw: 3 amps on 12 Volts DC (7.2 amps for 60 seconds to start) Cord: Detachable 16 foot, outdoor rated cord with cigarette plug. Weather tight connector enables operators to disconnect cord at 12 inches from the light for storage or vehicle
-
Supplier: Larson Electronics LLC
Description: Amp Draw: 3 amps on 12 Volts DC (7.2 amps for 60 seconds to start) Cord: Detachable 16 foot, outdoor rated cord with cigarette plug. Weather tight connector enables operators to disconnect cord at 12 inches from the light for storage or vehicle portability.
-
Supplier: Larson Electronics LLC
Description: - Wrap around base seal prevents dirt from entering the base of the light. Includes rubber cord grip. Voltage: 12 Volts DC appropriate for most consumer vehicles, off road vehicles and small boats Lamp Wattage: 35 Watts HID Amp Draw: 7.2 cold start, 3 amps for continuous run off
-
Supplier: ValueTronics International, Inc.
Description: current power source and the equipment under test. Additional Features: Inductance µH: 50 0.25µf coupling caps Current Amps: 50 Line/Ground Voltage, 50-60 Hz: 270 Line/Ground Voltage, 400 Hz: 130 Case Size: 10.06" x 9.0" x 13.12" (25.72 cm x 22.86 cm x 33.34 cm) Circuit: Single
- Frequency Range: 50 MHz
- Output Current Rating: 50 amps
-
Supplier: Waytek, Inc.
Description: and/or maintenance. Mechanical Products 533-P0-060-22 Disconnect Switch Category: Battery Disconnects Manufacturer: Mechanical Products Ideally suited for the Marine, RV, Truck and Heavy Equipment industries, the one-of-a-kind Series 53 Branch Disconnect Circuit Breaker
- Current Rating: 60 amps
- Operating Voltage: 32 volts
- Power: DC
-
Supplier: Eaton Corporation
Description: HEAVY DUTY SAFETY TYPE 8-1/8 INCH W X 10 INCH D X 15-7/8 INCH H SIZE 3 WIRE(S) UL APPROVAL NEMA 3R ENCLOSURE 60 AMPERE CURRENT RATING 20 HP AT 480 VAC 1 PHASE, 25 HP AT 600 VAC 1 PHASE, 50 HP AT 480 VAC 3 PHASE, 60 HP AT 600 VAC 3 PHASE, 10 HP AT 250 VDC POWER RATING 3 POLE(S) NO
- Current Rating: 60 amps
- Operating Voltage: 277 to 600 volts
- Horsepower Rating: 10 to 60 HP
- Power: AC, DC
-
Supplier: Eaton Corporation
Description: MANUAL TRANSFER TYPE 11-15/16 INCH W X 9-7/8 INCH D X 36-5/8 INCH H SIZE 3 WIRE(S) UL APPROVAL NEMA 1 ENCLOSURE 60 AMPERE CURRENT RATING 20 HP AT 480 VAC 1 PHASE, 25 HP AT 600 VAC 1 PHASE, 30 HP AT 480 VAC 3 PHASE, 50 HP AT 600 VAC 3 PHASE POWER RATING 3 POLE(S) CLASS H FUSE TYPE NO NEUTRAL
- Current Rating: 60 amps
- Operating Voltage: 600 volts
- Horsepower Rating: 20 to 50 HP
- Power: AC, DC
-
Supplier: Appleton Electric
Description: HEAVY DUTY SAFETY TYPE 11.56 INCH W X 11 INCH D SIZE EPOXY POWDER COATED FINISH CAST COPPER FREE ALUMINUM ENCLOSURE MATERIAL UL 98 APPROVAL 60 AMPERE CURRENT RATING 15 HP AT 600 VAC 3 PHASE, 25 HP AT 600 VDC (STANDARD) 50 HP AT 600 VAC 3 PHASE, 30 HP AT 600 VDC (MAXIMUM) POWER RATING CLASS
- Current Rating: 60 amps
- Operating Voltage: 600 volts
- Horsepower Rating: 30 to 50 HP
- Power: AC, DC
-
Supplier: ABB Inc.
Description: DC switch-disconnectors 16...800 A Simply optimal The OTDCP range of enclosed switch-disconnectors from 16 to 800 Amperes is specially designed for DC applications. Thanks to a compact design, efficiency and reliability, OTDCP switches bring PV installations to the next level.
-
Supplier: Schneider Electric, Automation & Control
Description: Switch disconnectors from 40 A to 2500 A By adapting to a whole host of LV applications, the Compact INS/INV switch-disconnectors offer all the safety that the user requires. Designed for maximum performance and safety, this comprehensive and homogeneous range operates with a wide choice of
- Current Rating: 40 to 1,250 amps
- Operating Voltage: 500 to 690 volts
- Short Circuit Interrupt Capacity: 3 to 50 kiloamps
- Poles: 2 Poles, 3 Poles, 4 Poles
-
Supplier: ABB Inc.
Description: DC switch-disconnectors 16...800 A Simply optimal The OTDC range of switch-disconnectors from 16 to 800 Amperes is specially designed for DC applications. Thanks to a compact design, efficiency and reliability, OTDC switches bring PV installations to the next level. The
-
Supplier: Hubbell Electrical Products
Description: COPPER FREE ALUMINUM ENCLOSURE MATERIAL UL, CSA APPROVAL 120/240/480/600 VAC, 250 VDC VOLTAGE RATING CLASS II DIV 1 AND 2 GROUP E F G, CLASS III, NEMA 3R/4/9 ENCLOSURE 60 AMPERE CURRENT RATING BOLTED COVER TYPE 10 HP AT 120 VAC, 20 HP AT 240 VAC, 40 HP AT 240 VAC, 60 HP AT 600 VAC, 15
- Current Rating: 60 amps
- Operating Voltage: 120 to 600 volts
- Poles: 3 Poles
- Power: AC, DC
-
Supplier: Schneider Electric
Description: Welcome to the complete residential energy management solution tailored to utilities and personalized for consumers. Wiser actively engages consumers and fulfills energy efficiency and peak demand initiatives, creating a more reliable grid.
- Current Rating: 25 to 800 amps
- Operating Voltage: 125 to 690 volts
- Poles: 1 Pole, 2 Poles, 3 Poles
- Power: AC, DC
-
Supplier: Zhejiang Benyi Electrical Co., Ltd
Description: DC isolator switch 300V- 1200V up to 63A DC switch up to 63A 1200V, compact design for solar DC circuit, UPS, battery energy storage systems application. Non-polarity DC switch for easier wiring. Arc flash barrier design keeps solar equipment more safe and reliable. ,
- Current Rating: 25 to 63 amps
- Operating Voltage: 300 to 1,200 volts
- Poles: 1 Pole, 2 Poles, 3 Poles, 4 Poles
- Approvals: CE, RoHS
Find Suppliers by Category Top
Featured Products Top
-
extremely resistant to high temperatures, and can handle a wide range of switching applications including battery disconnect switching, air conditioners, lights, and hydraulic motors. (read more)
Browse Electrical Contactors Datasheets for Waytek, Inc. -
C303 – 1-pole bi-directional DC NO contactors up to 500 amps The Eddicy C303 1-pole bidirectional DC an AC contactors are compact high-performance switching devices for applications with high inrush (read more)
Browse Electrical Contactors Datasheets for Schaltbau GmbH -
connection during installation. Product Specifications: Rated Current: 2A for 2, 4 positions or 1.5A for 6, 8, 12, 16 positions. Rated Voltage: 60V AC/DC Operating Temperature Range: -40 to +125°C Materials: The connectors are (read more)
Browse Wire to Board Connectors Datasheets for Heilind Electronics, Inc. -
-Duty Ratings For normal-duty operation, the ATV630U55N4 provides a continuous output current of 12.7 A at the nominal 4 kHz switching frequency. It permits a temporary current increase to 110% of the rated output current for 60 seconds. This operating mode (read more)
Browse Electric Rotary Actuators Datasheets for ERSAELECTRONICS PTE. LTD. -
amp, are common in testing setups because signal levels are often too low for easy or accurate measurement. The two serve different functions and face differing requirements. A power amp might be matched to a signal source that would otherwise generate too little power to be useful. A signal (read more)
Browse RF Amplifiers Datasheets for A.H. Systems Inc. -
-matching technique that exhibits a DC short from center pin to ground. Other types, like narrowband horns, do not use the technique and are less susceptible. Personnel touch the antenna when making adjustments or to switch it from vertical to horizontal positioning to check results under different types (read more)
Browse RF Amplifiers Datasheets for A.H. Systems Inc.
More Information Top
-
New Products
phase and multi-phase AC and AC-DC switches; two-position 2, 3, and 4 PAC switches (available in 20, 30, 40, and 60 amp rating); and three-positionAC- DC switches with a positive stop “off” position. … wide range of indoor and outdoor electrical service, these CWD con- tractors and disconnect switches are recom …
-
Del City Announces New Hi-Amp Circuit Breakers
Del City Announces New Hi- Amp Circuit Breakers The circuit breakers feature a manual ON/OFF function, combining a manual reset thermal circuit breaker and an electrical disconnect switch . Every breaker is rated up to 48V DC with 3,000 cycles and is available in an assortment of amperages, ranging from 60 to 150 amps.
-
Del City Announces New Hi-Amp Circuit Breakers
Del City Announces New Hi- Amp Circuit Breakers The circuit breakers feature a manual ON/OFF function, combining a manual reset thermal circuit breaker and an electrical disconnect switch . Every breaker is rated up to 48V DC with 3,000 cycles and is available in an assortment of amperages, ranging from 60 to 150 amps.
-
A Versatile Subscriber Line Interface Circuit
Master Slice and Trimming The Al master slice provides a SLIC for constant resistance feed type or constant current feed type just by connecting or disconnecting VREF input to the switching follower amp shown in Fig 5. … preset VREF, the amp will keep its output at VREF level resulting in DC loop current limitted. Overvoltage Protection This function is provided by the combination of 60 V PN junction isolation with on …
-
The DIY Guide to OFF GRID Solar Electricity | AltEnergyMag
Batteries in series add voltage, batteries in parallel add amp hours. An inverter changes low voltage dc (Direct Current) into 120v ac (Alternating Current) for regular household appliances. Inverters can range from the cheap $ 60 750 watt Black and Decker from Walmart, to a $2500 Xantrex or Outback with integrated battery charger and transfer switch for connecting to the grid or a generator. Fuses, Breakers, and Disconnects .
-
EC Online Newsletter: OEL Announces New 'COMBINATION' Insulated Tools
… designed to provide fast-acting protection for high-current voltage regulator modules and DC-to- DC converters... Leviton Enhances PowerSwitch Line With New 30 AMP Front-Operated Safety Disconnect Switch Leviton PowerSwitch safety disconnect switches include 30-, 60 - and 100-Amp rated devices in fused and non …
-
CONTROL TECHNIQUES: Focus 1 Analog DC Drives With Solid-state, Full Wave Design
Focus 1 Analog DC Drive features: • Designed for 50 or 60 Hz operation • One amp , full wave field supply • Enclosed unit features: double pole AC power disconnect switch , stop/start selector switch, speed potentiometer .
-
Photovoltaic power systems and the National Electrical Code: Suggested practices
… and resistance44 Circuit Breakers in branch circuits41 Circuit Breakers with pressure connectors 16 Circuit Breakers,25 amp, E-19 Circuit Breakers,27 amp, E-20 Circuit Breakers,30 amp , E-7, E-19 … … A-1 Circuit Breakers, dc -rated 47, C-2 … Connectors, NEMA 125-voltlocking 61 Connectors, split-bolt 16 Crimped ring terminals 10 Crimped splicing connectors 16 Current-limitingfuses, 44 DC combiningbox 60 DC load center 60 DISCONNECT (S),C-2 Disconnect devices33,50,61 Disconnect switches 23,45,46,50,63 …
-
New-generation CCD controller requirements and an example: the San Diego State University generation II controller
Similar to the clock driver board MOSFET switches are placed between the DC bias supply drivers and the board output to disconnect the supplies from the CCD until they are fully configured during power up, or to disconnect them suddenly if there's … The clock drivers operate with a fast op amp that produces 60 mA of sustained output current, and slews over a ten volt range in 20 nanosec.
-
A 1.5-V, 10-bit, 14.3-MS/s CMOS pipeline analog-to-digital converter
To achieve an overall linearity of ten bits, the (first- stage) op- amp dc gain must be greater than 60 dB and settle to 0.1% accuracy in less than one-half clock cycle (35 ns). Switched -capacitor common-mode feedback operating on a 50% duty cycle was employed to stabilize the common … The high-swing switches discussed above were used to connect and disconnect the common-mode sensing capacitors.
Indicates content that may require registration and/or purchase.