-
Supplier: CO2Meter.com
Description: 3-relays dependent upon application 4-20mA to communicate with Building Management System (BMS) Models CM-902-S: Industrial Stainless Steel O2 Gas Detector CM-900: CO2 Industrial Gas Detector CM-900-S: Industrial Stainless Steel CO2 Gas Detector Warranty
- Gas Types: Carbon Dioxide (CO2)
- Features: Other
- Number of Gases Monitored: Single Gas
-
Supplier: CO2Meter.com
Description: requirements around Food Grade Packaging Standards Designed to meet CGA, OSHA, and NIOSH standards for gas safety User configurable 3-relays dependent upon application 4-20mA to communicate with Building Management System (BMS) Models CM-902: O2 Industrial Gas Detector CM-900:
- Features: Other
- Number of Gases Monitored: Single Gas
-
Supplier: CO2Meter.com
Description: The Fixed Oxygen (O2) Gas Detector (MSC2 + SC2-E1195-A2-P-00) is designed to protect individuals near toxic gases in commercial and industrial applications. This fixed gas safety monitor measures nitrogen, helium, oxygen (0-25%), and argon levels and detects hazards in
- Operating Temperature: -13 to 140 F
- Operating Humidity: 15 %
- Measurement Type: %Volume
- Gas Types: Carbon Dioxide (CO2), Oxygen (O2)
-
-
Supplier: Restek
Description: one-year warranty, the Restek® leak detector is the industry standard for performance and affordability in handheld leak detectors. Leak Detector Specifications Detectable Gases: Helium, nitrogen, argon, carbon dioxide, hydrogen Battery: Rechargeable lithium ion internal
- Operating Temperature: 32 to 120 F
- Operating Humidity: 0 to 97 %
- Display: Analog
- Features: Audible or Visual Alarms, Other
-
Supplier: ASTM International
Description: This method is for determining trace permanent gases in high purity polymer grade ethylene and propylene gas or liquid using a gas chromatograph (GC) equipped with a pulsed discharge helium ionization detector (PDHID). The instrument is preconfigured and capable of determining
-
Supplier: Process Sensing Technologies USA
Description: PlasmaDetek 2 from LDetek is a microprocessor-based plasma emission detector system. It has an intelligent, customizable configuration capability to make industrial gas chromatography simple and accessible across a wide range of applications. An ‘all in one’ detector, it not
- Operating Temperature: 50 to 122 F
- Instrument Type: Detector
- Application: Process Gas
- Features: Self Calibration
-
Supplier: Dexter Research Center, Inc.
Description: Features: A thin film-based single element thermopile detector that offers the world™s highest sensitivity in a TO-5 package. Dare to compare. Low noise voltage of 12.8nV/ˆšHz. Applications: Excellent for gas analysis, fire detection and non-contact temperature measurement. Benefit:
- Operating Temperature: -58 to 212 F
- Responsivity: 15.2 to 22.7 mV/µW
- Detectivity: 1.9 to 5 10^8cmHz^(½)/W
- Category: Sensor / Transducer
-
Supplier: Dexter Research Center, Inc.
Description: Features A thin film-based single element thermopile detector that offers the world's highest sensitivity in a TO-5 package. Dare to compare. Low noise voltage of 12.8nV/√Hz. Applications Excellent for gas analysis, fire detection and non-contact temperature measurement. Benefit
- Operating Temperature: -58 to 212 F
- Electrical Outputs: Analog Voltage
- Features: Temperature Measurement
-
Supplier: Dexter Research Center, Inc.
Description: Features: A single-channel silicon-based thermopile that offers the smallest single element active area size at 0.25mm x 0.25mm in a TO-5 package. Delivers a very fast 12ms time constant in Argon encapsulation gas and even faster with Neon gas at 9ms. Delivers a very low
- Operating Temperature: -58 to 212 F
- Responsivity: 169.7 to 218.2 mV/µW
- Detectivity: 2 to 3.2 10^8cmHz^(½)/W
- Category: Sensor / Transducer
-
Supplier: Process Sensing Technologies USA
Description: requirements: ready-to-use device. Stand-alone instrument for multiple trace impurity measurements. Multiple detectors: PED, TCD and FID. Wide measurement range covers sub-ppb to percent measurements. PPB sensitivity with argon, helium or nitrogen carrier gas (PlasmaDetek) Easy
- Operating Temperature: 50 to 113 F
- Remote Interface: Other
-
Supplier: LECO Corporation
Description: with either helium or argon carrier gas
- Analysis Method / Detection Technology: Carrier Gas Hot Extraction (HE), Inert Gas Fusion (IGF), Infrared Detector (IR Cell), Thermal Conductivity Detector
- Test Media / Material Analyzed: Inorganic Material
- Elements Analyzed: Nitrogen (N) / Protein, Oxygen (O)
-
Supplier: Process Sensing Technologies USA
Description: The LD8000 is an online analyzer to monitor trace N2 in Ar/He/Crude Argon. A plasma emission detector is used to selectively measure trace N2 in pure Argon or/and Helium bulk gases as well as Argon containing up to 5% O2. The analysis of trace N2 in Neon, Xenon and
- Operating Temperature: 50 to 113 F
- Instrument Type: Analyzer
- Application: Process Gas
- Features: Self Calibration
-
Supplier: ASTM International
Description: process unit sources as well as in the sample introduction into the analyzer in the laboratory. 1.5 Water vapor may interfere with the C6+ analysis if a TCD detector is used. 1.6 Helium and argon may interfere with the determination of hydrogen and oxygen respectively. Depending on the
-
Supplier: ASTM International
Description: nitrogen (N2), as well as vapors from organic compounds with boiling points up to 125°C. 1.3 The detection limits obtained will depend on the portable gas chromatograph and detector used. Detectors available include thermal conductivity, photoionization, argon ionization,
-
Supplier: ASTM International
Description: (CO2) and nitrogen (N2), as well as vapors from organic compounds with boiling points up to 125°C. 1.3 The detection limits obtained will depend on the portable gas chromatograph and detector used. Detectors available include but are not limited to thermal conductivity,
-
Supplier: Process Sensing Technologies USA
Description: The LD8000-Plus is designed for ultra-pure Argon or Helium gas analysis. With its integrated ppb sub-system, unique performance can be achieved. Low ppb trace nitrogen online is now possible without the need of a gas chromatograph. This compact design makes it very attractive
- Operating Temperature: 50 to 113 F
- Instrument Type: Analyzer
- Application: Process Gas
- Features: Self Calibration
-
Supplier: CO2Meter.com
Description: detection and multi-layered alerts in the event of dangerous gas levels or system power failure. What's Included: RAD-0002-ZR-HS2 O2 Safety Alarm - industry-proven gas detector featuring a clear digital display, multiple alarm setpoints, and relay outputs. Ideal for enclosed
- Measurement Type: %Volume
- Features: Other
- Number of Gases Monitored: Single Gas
-
Supplier: Oneida Research Services, Inc.
Description: spectrometer and is easily adapted to measuring the leak rates for other gases such as Oxygen, Argon, Nitrogen, DME, EMC, SF4 and other gases. It is not just for Mil-Std 883. Simply purchase your leak rate standards, enter a few parameters into the software and the system is ready to test the
- Local Interface: Computer Interface, Digital Front Panel
- Leak Test Method: Mass Spectrometer (Helium Leak Detector)
- Features: Self-calibrating
- Display Type: Video Display Terminal
-
Supplier: Dexter Research Center, Inc.
Description: with increase in noise and a time constant of 48ms in Argon encapsulation gas.
- Operating Temperature: -50 to 100 C
- Applications: Industrial
- Features: Other
- Sensor Type: Temperature Sensor
Find Suppliers by Category Top
Featured Products Top
-
target is set to Isobutane, Methane or Propane. The XP-3340 can measure 0-100% Vol. of highly concentrated gases including Helium, Methane, Isobutane, Argon, Carbon Dioxide, etc. (read more)
Browse Gas Instruments Datasheets for DOD Technologies Inc. -
Nitrogen encapsulation gas. Delivers a very low Temperature Coefficient of Responsivity of -0.04%/°C. This detector has a very short thermal shock response to ambient temperature change. View (read more)
Browse Datasheets for Dexter Research Center, Inc. -
The Acme REF-IR-ST Sensor/Transmitter is designed to detect the presence of refrigerant leaks in enclosed areas. The REF-IR-ST series employs a high-precision NDIR sensor ideal for gas-specific and accurate measurements of the most commercially used refrigerants. With its 1PPM resolution (read more)
Browse Gas Transmitters Datasheets for Acme Engineering Products -
Dexter Research - Gas Analysis Thermopile Detector Applications: Excellent for gas analysis, position sensor, and horizon sensor. A four-channel silicon-based thermopile in a TO-5 package. Each small active area is 1.2mm (read more)
Browse Datasheets for Dexter Research Center, Inc. -
-made components on more than 1.600 m² of clean room space – especially pyroelectrical infrared detectors – for clients worldwide. The product range includes analogue single and multi-channel detectors as well as digital multi-channel detectors (PyrIQ). The detectors are used, for example, in gas analysis, fire and flame sensors and spectroscopy. (read more)
Browse Gas Sensors Datasheets for InfraTec GmbH -
Model SA-220 is an advanced single or dual gas detection transmitter designed for use with Safeguard Analytics’ complete range of Model SA2 “smart sensor modules”. A diffusion-based detector, with the gas type and sensitivity range determined by (read more)
Browse Gas Transmitters Datasheets for Safeguard Analytics -
Introducing our Updated SA2 Platform — Built for Every Industry Safeguard Analytics is proud to introduce a new addition to the SA2 Platform, our next-generation fixed gas detector, the SA-220 Now our SA2 Platform (read more)
Browse Gas Sensors Datasheets for Safeguard Analytics -
/installation costs Access instrument via Bluetooth for real-time status Easily retrofits with legacy General Monitors detectors Learn More Request Info (read more)
Browse Gas Instruments Datasheets for MSA Safety -
VISION 8 Continuous Gas Detector with EλE Sense Technology The VISION® 8 from DOD Technologies is the world’s first, and only, color-sensing and differentiating colorimetric gas detection system. Capable of distinguishing between different gases within the same family, the (read more)
Browse Gas Sensors Datasheets for DOD Technologies Inc. -
The Vanguard TCD60 adds to the versatility of the Vanguard TCD50 by providing three options for antenna gain and a remote mount option for the antenna. This aids with better placement of the antenna to improve signal transmission while keeping the gas sensor where it is needed. One (read more)
Browse Gas Instruments Datasheets for United Electric Controls Company
More Information Top
-
Demonstration of Key Elements of a Dual Phase Argon Detection System Suitable for Measurement of Coherent Neutrino-Nucleus Scattering
Figure 2: Spectrum from 50-nCi Fe-55 source, as measured in the Argon gas detector .
-
A Proposal for First-Ever Measurement of Coherent Neutrino-Nucleus Scattering
We have proposed to build a 10 kg dual-phase liquid/ gas argon detector for attempting a first-ever measurement of coherent neutrino-nucleus scatter.
-
Planning the Future of U.S. Particle Physics (Snowmass 2013): Chapter 8:
Instrumentation Frontier
5) Two-stage liquid/ gas argon detectors (the Darkside family of detectors [61]), which use S1 and S2 light as well as S1 pulse shape discrimination, and single stage liquid argon detectors (the DEAP/CLEAN family of detectors [62]), which use pulse shape…
-
Gas Entry Through Water-saturated Argillite: Experimental And Numerical Approaches
Gas detection is performed using both the downstream pressure transducer (±100 Pa) and a dedicated argon gas detector (±0.1µl/sec).
-
Science and Technology Review January/February 2006
The team has designed and proposes to build a small, liquid– gas argon detector to observe this .
-
The hunt for coherent neutrino-nucleus scattering with ionization argon detectors
We set off by building a single-phase Argon gas detector to investigate the systematics of the gain region and to understand the effect of various operating parameters.
-
The ionization mechanism in a micro-argon detector for gas chromatography
The action of a micro- argon gas chromatographic detector , as described by Lovelock in 1960, is investigatedin quantitative terms.
-
EMISSION DETECTORS
The first electron emission two-phase (solid and gas argon ) detector was constructed by a graduate student, G.W. Hutchinson, in 1948 (Hutchinson, 1948).
-
Simulation of the LHC BRAN luminosity monitor for high luminosity interaction regions
This Argon gas ionization detector measures the forward neutral particles from col- lisions at the interaction point.
-
High Voltage in Noble Liquids for High Energy Physics
Studying argon gas ionization detector with a aluminized Mylar film cathode, the authors of Ref. [2] observed sensitivity of the device to visible light when positive ions were present on the surface of the aluminum cathode.
Indicates content that may require registration and/or purchase.