Products & Services
See also: Categories | Featured Products | Technical Articles | More Information-
Description: This test method describes a procedure for conducting controlled velocity corrosion tests in the laboratory in which a corrosive solution may be moved at a known tangential velocity across the face of corrosion test specimens. The test method is useful in comparing the effects
-
Description: This standard test method was developed to address a number of testing parameters involved in the laboratory corrosion testing of clean metal test specimens in static chemical cleaning solutions at temperatures above boiling 100°C [212°F]}. Specifically, this standard addresses those
-
Supplier: AMPP Resources
Description: with corrosion coupons in the clean condition (i.e., no deposits). The tests consist of exposing metallic coupons to cleaning solvents under controlled conditions. The coupons are weighed before and after the test and the corrosion rate is calculated from the weight loss. Localized
-
-
Supplier: NACE International
Description: This standard test method was developed to address a number of testing parameters involved in the laboratory corrosion testing of clean metal test specimens in static chemical cleaning solutions at temperatures above boiling 100°C [212°F]}. Specifically, this standard addresses those
-
Description: with corrosion coupons in the clean condition (i.e., no deposits). The tests consist of exposing metallic coupons to cleaning solvents under controlled conditions. The coupons are weighed before and after the test and the corrosion rate is calculated from the weight loss. Localized
-
Description: laboratory testing against alternatives. Rigorous protocols based on ASTM standards, conducted at the Sherwin-Williams labs where the first CUI coating was pioneered in 1999, documented better corrosion and abrasion resistance, increased flexibility and harder film.
- Wet / Applied Thickness: 0.008 to 0.01 inch
- Cure / Dry Temperature: 50 to 120 F
- Operating / Use Temperature: 210 to 1,000 F
- Dispensing Method: Brush / Roll-on
-
Supplier: AMPP Resources
Description: This standard establishes a slow strain rate (SSR) test method for screening corrosion-resistant alloys (CRAs) (i.e., stainless steels and nickel-based alloys) for resistance to stress corrosion cracking (SCC) at elevated temperatures in sour oilfield production environments. The SSR
-
Description: This standard establishes a slow strain rate (SSR) test method for screening corrosion-resistant alloys (CRAs) (i.e., stainless steels and nickel-based alloys) for resistance to stress corrosion cracking (SCC) at elevated temperatures in sour oilfield production environments. The SSR
-
Supplier: AMPP Resources
Description: the impact on materials integrity. Oilfield microorganisms can affect materials integrity profoundly through a multitude of elusive (bio)chemical mechanisms, collectively referred to as microbiologically influenced corrosion (MIC). MIC is estimated to account for 20 to 30% of all
-
Supplier: NACE International
Description: Corrosion test information is often needed for selecting metallic construction materials for chemical process and other equipment. Usually, the information most readily available is laboratory corrosion test results for a specific set of controlled conditions. However,
-
Supplier: AMPP Resources
Description: Corrosion test information is often needed for selecting metallic construction materials for chemical process and other equipment. Usually, the information most readily available is laboratory corrosion test results for a specific set of controlled conditions. However,
-
Supplier: ASTM International
Description: 1.1 This guide covers procedures, specimens, and equipment for conducting laboratory corrosion tests on metallic materials under conditions of high pressure (HP) or the combination of high temperature and high pressure (HTHP). See 3.2 for definitions of high pressure and
-
Supplier: SAE International
Description: This standard covers the requirements and methods for laboratory test\u2014including vibration, moisture, dust, corrosion, color, and photometric tests for: Sealed Beam Headlamp Units for Motor Vehicles\u2014SAE J579 Sealed Beam Headlamp\u2014SAE J580 Electric Supplementary Driving
-
Supplier: ASTM International
Description: resistance to localized corrosion. 1.2 This test method applies only to passive metals and alloys. Nonpassive alloys (other than noble alloys) are susceptible to general corrosion and are not normally suitable for implant use. 1.3 The test method is intended for use as a
-
Supplier: ASTM International
Description: adequate photographic, micrographic, and chemical laboratory examinations at specific stages of deterioration, and at the end of the tests. 1.2 This standard may involve hazardous materials, operations, and equipment. This standard does not purport to address all of the safety problems
-
Supplier: NACE International
Description: REAFFIRMED IN 2006! Provides manufacturers, applicators, and users of internal pipe coatings with a method of comparing the performance of these coatings. Comparisons were made under uniform laboratory conditions. Key words: autoclave testing, oilfield production equipment, plastic
-
Supplier: ASTM International
Description: impedance data at the open circuit or corrosion potential that should reproduce data determined by others at different times and in different laboratories. This practice may not be appropriate for collecting impedance information for all materials or in all environments. 1.2 This standard
-
Supplier: NACE International
Description: This National Association of Corrosion Engineers test method was prepared by Task Group T-1G-12 of Unit Committee T-1G on Protective Coatings and Nonmetallic Materials for Oil Field Use and is issued by Group Committee T-1 on Corrosion Control in Petroleum Production. The standard
-
Supplier: Gems Sensors & Controls
Description: MOPD: 250 psi (17 bar) CV Range: 0.018 to 0.070 0.65 Watts to 2.0 Watts This versatile 2- or 3-way subminiature valve utilizes a stainless steel body to resist corrosion for most acids, alkaline solutions, and harsh environments. Applications: Hospital Equipment Laboratory
- Pressure Rating: 10 to 250 psi
- Number of Ports/Ways: 2 to 3
- Flow (Cv): 0.018 to 0.07
- Actuation: Electric
-
Supplier: TIGER Drylac Powder Coatings
Description: Epoxy based powder coating for interior applications. Typical Applications Laboratory equipment. Machinery parts. Pump housing. Surfaces where increased chemical resistance is required. Features Very good mechanical properties. Excellent chemical resistance. Good resistance to
- Features: Coating
- Type: Powder Coating
-
Supplier: Cincinnati Sub-Zero Products
Description: Chamber Calibration Services We offer NIST traceable and A2LA Accredited calibration for all makes and models of environmental test chambers, corrosion chambers and liquid baths. Below is a sample list of the calibration services we provide. Please contact us with your specific calibration
- Service Capability: Calibration Service, Preventative Maintenance, Spare Parts Inventory, Upgrade Service
- Products Serviced / Replaced: Environmental Test Equipment, Laboratory / Analytical Equipment
- Features: Midwest US Only, North America, United States Only
-
Supplier: GEA Process Engineering Inc.
Description: an ideal piece of laboratory equipment, easy to commission and operate, and can be dismounted for maintenance and cleaning by the laboratory operator. The Panda is supplied with an electronic digital pressure gauge (0-1600 bar) with built-in pressure pulsation damping system.
- Features: Homogenizer
-
Supplier: BEING Scientific Inc.
Description: control. Vacuum Range: 0 - 0.1MPa. (limit vacuum 133Pa) Bundled heating provides better temperature uniformity. Inert gas interface for easy access to inert gases such as nitrogen. LED lighting. Convenience Inner chamber is made from corrosion-resistant mirror stainless steel. Built-in
- Temperature Range: 86 to 392 F
- Capacity: 1.7999999999999998 cubic feet
- Features: Alarms, Laboratory, Other, Shelving / Racks / Carts, Timers
- Heat Source: Electric / Resistance
-
Supplier: APV, An SPX Brand
Description: The UFO - Unit for Filtration of Oil - is a separate unit which connects easily to the oil sump on gears and cranks. It contains all the necessary equipment for separation of water from the oil and fine filtration of the oil. If you are experiencing problems with reduced durability of the
- Pressure Range: 1,015 to 21,750 psi
- Operating Condition: Batch Operation
- Mounting: Floor-Mounted
- Applications / Industry: Food and Beverage Processing
-
Supplier: Thomas An Ingersoll Rand Business
Description: tested per Agency standards RoHS compliant Range Technical Overview Flow 2.3 cfm (65 l/min) Max. pressure 100 psi (6.9 bar) Possible Applications Blood Analyzers Laboratory Analyzers Dental Equipment Packaging/Printing Equipment Pond Aeration
- Discharge / Operating Pressure: 100 psi
- Flow Capacity: 2 to 2.3 SCFM
- Horse Power: 0.388663911621818 to 0.452994490097153 HP
- Power Source: AC Single Phase
-
Supplier: Thomas An Ingersoll Rand Business
Description: Laboratory Analyzers Dental & Optical Equipment Ozone Generators Vacuum Frames Waveguide Pressurization Packaging Equipment Aspirators Respirators Medical Trauma Carts Laboratory Air Dryers Powder Spraying Duplicators Printing Equipment Mail Sorters/Stuffers Cable
- Ultimate Operating Vacuum: 81.82 torr
- Pumping Speed: 2.4 CFM
- Operating Temperature: 50 to 104 F
- Features: AC Single Phase, Compressed Air / Fluid
-
Supplier: Stafford Manufacturing Corp.
Description: Chrome Plated Shaft Collars are ideal for use in consumer products such as fitness equipment and in medical and laboratory instruments where appearance and corrosion resistance are important. 1-Piece Clamp-Type Shaft Collars are designed for use on standard round shafts, hard or
- Width: 0.5 inch
- Bore Diameter: 0.688 inch
- Outer Diameter: 1.5 inch
- Units: English
-
Supplier: Stafford Manufacturing Corp.
Description: Chrome Plated Shaft Collars are ideal for use in consumer products such as fitness equipment and in medical and laboratory instruments where appearance and corrosion resistance are important. 1-Piece Clamp-Type Shaft Collars are designed for use on standard round shafts, hard or
- Width: 0.5 inch
- Bore Diameter: 1.25 inch
- Outer Diameter: 2.063 inch
- Units: English
-
Supplier: Gusher Pumps
Description: Systems Washing Plants Filtration Systems Refrigeration Systems Temperature Control Units Eroding Systems Paraffin Systems Filing systems Galvanic Equipment Chemical Equipment Photographic Equipment Surface Coating Sewage Treatment Industrial Furnace Construction Engine Test
-
Supplier: Mar Cor Purification
Description: Furthermore, if not mixed properly, bicarbonate can negatively affect the dialysate solution. Standard Features The cone bottom tank and system frame are made of polyethylene while the enclosure and pump panels are made of polycarbonate and PVC to prevent rust and corrosion from destroying
- User Interface: Analog Front Panel
- Mounting: Floor-Mounted
- Mixer / Homogenizer Location: In-Line
- Media Type: Liquids, Solutions, Emulsions
-
Description: Nuclear power facilities Chemical processing equipment Institutional & commercial wall coating Suitable for use in USDA inspected facilities Conforms to AWWA D 102-03, OCS #5 Acceptable for use in high performance architectural applications.
- Wet / Applied Thickness: 0.004 to 0.007 inch
- Cure / Dry Temperature: 55 to 110 F
- Operating / Use Temperature: 55 to 200 F
- Substrate: Aluminum, Concrete / Masonry, Metal, Steel, Wood
-
Supplier: Labconco Corporation
Description: Utility Cart, may be used as a compact, mobile work station for laboratory equipment. An open shelf transports and supports small electrical equipment. A pan holds additional small items. Features: Attached power strip with 115 volts, 60 Hz, 12 amps capacity, has six electrical
- Capacity: 400 lbs
- Length: 15.75 inch
- Width: 14.88 inch
- Cart / Truck Type: Instrument Cart, Platform Cart / Truck
-
Supplier: Micromeritics
Description: The AutoChem II 2920 is a fully automated chemisorption analyzer that can provide your laboratory with the ability to conduct a comprehensive array of highly precise studies of chemical adsorption and temperature-programmed reactions. With this single instrument, you can acquire valuable
- Properties Analyzed: Adsorption / Desorption (Chemisorption/ Physisorption), Surface Area - Total
- Display & Special Features: Analog Meter
- Test Media: Chemicals, Metals
- Mounting / Loading Options: Laboratory / Batch
-
Supplier: Piezo-Metrics
Description: series with absolute or sealed reference options. Long term stability options are available. APPLICATIONS Test & measurement equipment Production equipment & controls Energy controls Laboratory instruments & equipment Calibration equipment
- Working Pressure Range: 7,000 psi
- Operating Temperature: 0 to 180 F
- Measurement Type: Absolute, Sealed
- Media: Gas, Liquid
-
Supplier: Mobil Industrial Lubricants
Description: Enhance your productivity with Mobil SHC Gear synthetic industrial gear oils — next-generation technology providing superb equipment protection and oil life under extreme conditions. Greater energy efficiency up to 3.6% With a high viscosity index and low traction coefficient, Mobil SHC Gear
- Kinematic Viscosity (@ 40°C): 680 cSt
- Viscosity Index: 184
- Pour Point: -54.4 F
- Flash Point: 453.2 F
Find Suppliers by Category Top
Featured Products Top
-
testing (UT) equipment. Solution to Scrubber Corrosion Exhaust Gas Cleaning Systems (EGCS) – more commonly known as “scrubbers” – are installed on thousands of vessels worldwide in order to comply with the IMO 2020 Sulphur Cap. They have (read more)
Browse Nondestructive Testing (NDT) Equipment Datasheets for Cygnus Instruments Limited -
INOCART HF COMPLETE POWDER PACKAGE The Inocart HF is a simple and complete manual solution for applying thermoplastic and anti-corrosion powders. Using the Inogun M spray gun and the Inobox control module, it enhances the user's experience with a (read more)
Browse Powder Coating Equipment Datasheets for Sames North American Corporation -
We are pleased to announce the acquisition of Janis Research’s Laboratory Cryogenics business — a move that unites two of the world’s leading providers of cryogenic and material characterization solutions for low-temperature research! This acquisition (read more)
Browse Cryogenic Equipment Datasheets for Lake Shore Cryotronics, Inc. -
• 4 ports flexible configuration • Stable outlet pressure • Simple outlet pressure limitation by handwheel • Inlet filler • Tested for use with oxygen Typical Applications • Component Testing • Calibration Systems • Laboratory Pressure Control • High Pressure Sampling Systems • Service & Test Equipment (read more)
Browse Semiconductor Wet Process Equipment Datasheets for Shenzhen Jewellok Technology Co., Ltd. -
Laboratory Laboratories need flexible workspaces. Choose Rousseau for innovative solutions that meet your needs. Flexible products built for the unique needs of laboratories Rousseau (read more)
Browse Medical Equipment and Supplies Datasheets for Rousseau Metal Inc. -
(UT) equipment for corrosion inspection, flooded member detection, and leak detection of marine structures and vessels of all sizes. Corrosion is a critical threat to the structural integrity of ships and offshore structures. These structures are constantly exposed to moisture in the air and (read more)
Browse Nondestructive Testing (NDT) Equipment Datasheets for Cygnus Instruments Limited -
. Laboratory: Cooling research equipment. Industry: Metal treatment and food freezing (read more)
Browse Gas Generation Equipment Datasheets for Cryo H&I Co.,Ltd. -
hazardous environments to carry out regular preventative structural monitoring without the costs of shutdown, disruption or outsourcing, whilst balancing increasing demand in a 24/7 production culture. Monitoring Corrosion on Oil and Gas Vessels and Scrubbers (read more)
Browse Nondestructive Testing (NDT) Equipment Datasheets for Cygnus Instruments Limited -
cryogenic laboratory. Download the paper to learn about: Conducting a consumption audit to account for all aspects of helium usage within your organization What a helium reclamation system is, and if it is a good fit for your situation How to lower costs (read more)
Browse Cryogenic Equipment Datasheets for Lake Shore Cryotronics, Inc. -
Applications: Air Lines Chemical Lines Fluid Feeds Food & Beverage Processing Hospitals & Laboratories Instrumentation OEM Large Machines Spacers Wire Jacketing (read more)
Browse Datasheets for NewAge Performance Products | NAPP
Conduct Research Top
-
Avoiding Machinery Wear and Corrosion
While it is true that all machines eventually wear out, proper maintenance and care can improve machinery health and longevity. This is particularly true with regard to the two most common types of machine degradation: corrosion and wear. As machine operators know, water and many metals do not mix
-
Evolution of the laboratory vacuum pump
loborotory pump. However, if one $udies the evolution of fie loboratory pump over the po$ 25 yeors, il. becomes opporent thot this is an oreo of significant innovotion, with importonl developments. in high vocuum lechnology, corrosion resistonce, vocuum control, ond improvements in the. efficiency
-
Sourcing Complex Quartz Components
The unique thermal, optical and mechanical properties of quam glass make it ideal for. use in a wide variety of applications where other materials are problematic. Properties such as hardness, chemical purity, resistance to high temperatures and. corrosion, and electrical insulation - to name a few
-
Zirconium in Organic Applications (.pdf)
Laboratory studies and case histories have established zirconium as the most corrosion resistant material of construction in many production methods involving organic media. In fact, zirconium plays a pivotal role in production of a wide range of organic materials including formic, acetic
-
Interphex 2006 Preview: The Best of the Phex
By Paul Thomas, Managing Editor PermaShield Pipe (PSP) is a Factory Mutual Systems-approved corrosion-resistant vent pipe system for use without sprinklers. PSP's proprietary, highly chemical-resistant, fluoropolymer ETFE coating on stainless steel ducts or pipes can be cut to length in the field
-
Detrimental Element Analysis of Non-Metallic Materials Used in Nuclear Reactors
Metals and anions that initiate or accelerate corrosion are of concern in evaluating the suitability of a non-metallic material for use in a nuclear reactor environment. This paper describes several analysis techniques for measuring concentrations of these detrimental elements. Chemical analysis
More Information Top
-
Fiscal Year 1985 Congressional budget request. Volume 1. Atomic energy defense activities
… equipment, including upgrading and metrification of measuring equipment; (2) process development equipment, such as laser and metal- working equipment; (3) l'aboratory engineering and test equipment, including pumps, laboratory transducers, and autoclaves; (4)analytic, spectrochemical and corrosion laboratory equipment , such as test units …
-
Messages, pp. (A42-A65)
So, can it occur, daB by a new synthesis neither starting materials, nor the end product through au-Bergewohnlichkorrosive properties strike - and however, is to observe on important parts of the testing facility of corrosion .
-
The FFC Cambridge process and its relevance to valorisation of ilmenite and titanium-rich slag
The salt vapour can condense in, and block the gas outlet of the reactor, and is also very hygroscopic and corrosive to laboratory equipment .
-
A very thin coating for capillary zone electrophoresis of proteins based on a tri(ethylene glycol)‐terminated alkyltrichlorosilane
Com- pared to the piranha treatment, the RCA Clean 1 proce- dure was judged to be marginally safer, easier to imple- ment, and less corrosive to laboratory equipment .
-
Trends in chemistry analysis procedures at nuclear plants
21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS; NUCLEAR POWER PLANTS; PRIMARY COOLANT CIRCUITS; NUCLEAR REACTION ANALYSIS; RADIATION CHEMISTRY; BWR TYPE REACTORS; CHROMATOGRAPHY; CORROSION ; LABORATORY EQUIPMENT ; OPERATION; PWR TYPE REACTORS; RADIATION DOSES; CHEMICAL ANALYSIS; CHEMICAL REACTIONS; CHEMISTRY; COOLING SYSTEMS; DOSES; ENERGY SYSTEMS; EQUIPMENT …
-
In the news
scribes the planning of corrosion tests, evaluation of test results, the latest in laboratory corrosion testing and equip- ment , simulated service testing, and in- service techniques for damage detection and monitoring.
-
Aluminium content of beers
Evenshtein investigated corrosion of laboratory processing equipment (fermen- ters, tanks, etc), made from either 99.5% or 99.99% Al, during the processes of fermentation and lagering of three brands of beer.
-
Effect of Cleanup Acids on Compressive Strength of Proppants Used In Gravel Packing
This helped also to minimize the corrosion of laboratory testing equipment .
-
Prediction of Corrosion in Oil Gas wells
Fig. 2 -Operating Unit of Experimental Laboratory Field Corrosion Testing Equipment .
-
Seasonal change of physical wood properties in an oak tree (Quercus Robur L.)
The Fasers,:-ittigungsfeuchtigkeit wasn't determined, waving its experimental Beslimmung this fiir because of corrosion on the test equipments the other measurements unusable gernacht hiilte.
Indicates content that may require registration and/or purchase.