Supplier: Define Instruments
Description: What it does: Accepts mA input from a flow meter and displays a total. Offers optional relay and analog output for set point alarming and control, plus serial communications. This rate meter and totalizer is ideal for flow rate monitoring of transmitters and sensors with mA
- Number of Control Outputs: 4 outputs
- Outputs: Analog Current, Analog Voltage, Switch
- Display Types: Digital
- Local Interface: Digital Front Panel
-
Supplier: Define Instruments
Description: What it does: Accepts digital pulse inputs from flow sensors and meters. Dual display shows the flow rate and volume. This dual display flow batching totalizer accepts a variety of flow sensor inputs, and has a variety of advanced features, including:
- Number of Control Outputs: 4 outputs
- Outputs: Analog Current, Analog Voltage, Switch
- Display Types: Digital
- Local Interface: Digital Front Panel
-
Supplier: OMEGA Engineering, Inc.
Description: The FPM-5750 Battery Operated Flow Indicator and Totalizer is compatible with the following flow sensors: FP-5300, FP-5100, FP-5200 and FP-6000 flow sensors (see related links below). The large digital display indicates flow rate and totalized flow
- Number of Inputs: 1 inputs
- Number of Control Outputs: 1 outputs
- Operating Temperature: 14 to 149 F
- Outputs: Analog Current
-
-
Supplier: Fluidwell bv
Description: or total. Flow rate: seven 17mm (0.67") or 8mm (0.31") digits. Total - resettable: seven 17mm (0.67") digits. Accumulated total - not resettable: eleven 8mm (0.31") digits. Separate engineering units for flow rate and total. Selectable on-screen engineering units for flow rate:
- Number of Inputs: 1 inputs
- Operating Temperature: -40 to 158 F
- Outputs: Analog Current, Analog Voltage
- Flow Sensor Inputs: Differential Pressure Meters, True Mass Flow Meters, Velocity Meters
-
Supplier: Define Instruments
Description: What it does: Accepts digital pulse inputs from flow sensors and meters. Displays the flow rate information and in-built totalizers convert the rate into volume. This dual totalizer flow rate controller accepts a wide range of industrial pulse and frequency
- Number of Control Outputs: 4 outputs
- Outputs: Analog Current, Analog Voltage, Switch
- Display Types: Digital
- Local Interface: Digital Front Panel
-
Supplier: Fluidwell bv
Description: The F112 is a versatile flow rate indicator and totalizer with the ability to precisely linearize the flow meter signal. In addition to the average K-Factor or Span, fifteen linearization points can be entered with their frequencies or values. The unit will interpolate between
- Number of Inputs: 1 inputs
- Number of Control Outputs: 1 outputs
- Operating Temperature: -40 to 176 F
- Outputs: Analog Current, Analog Voltage, Frequency / Pulse
-
Supplier: Hoffer Flow Controls, Inc.
Description: The Model 2005 is a microprocessor based temperature compensated flow rate indicator/totalizer that provides local display and transmits flow data for control capability. The unit is part of a cost effective family of flow products designed to accept inputs from pulse
- Number of Inputs: 3 inputs
- Number of Control Outputs: 4 outputs
- Operating Temperature: 32 to 158 F
- Outputs: Analog Current, Analog Voltage, Switch
-
Supplier: Aalborg Instruments
Description: Design Features Displays instantaneous, total and accumulated flow rates. Built-in Flow Linearizer (10 point linearization of the flow curve). Up to 47 different volumetric and mass flow engineering units. Large 13mm (0.51") digits for flow rate and 5.5mm (0.21")
- Control Signal: Analog Voltage, Current Loop, Pulse / Frequency, Serial / Digital
- Interface: Computer Programmable, Digital Front Panel, Ethernet / Networkable
- Type: Current Loop (Transmitter) Input, DC Voltage Input, Serial / Digital Input
- Media: Gas / Air, Liquid
-
Supplier: Hoffer Flow Controls, Inc.
Description: The Model 2000 is a microprocessor based volumetric flow rate indicator/totalizer that provides local display and transmits flow data for control capability. The unit is part of a cost effective family of flow products designed to accept inputs from pulse producing
- Number of Inputs: 3 inputs
- Number of Control Outputs: 4 outputs
- Operating Temperature: 32 to 158 F
- Outputs: Analog Current, Analog Voltage, Switch
-
Supplier: Fluidwell bv
Description: The F013 is a versatile flow rate indicator and totalizer with continuous flow rate monitoring feature. It offers the ability to set one low flow rate and one high flow rate alarm value. If desired, an alarm ignore function can be set up to allow for an incorrect
- Number of Inputs: 1 inputs
- Operating Temperature: -40 to 158 F
- Features: Alarm, Programmable
- Outputs: Analog Current, Analog Voltage, Switch
-
Supplier: Hoffer Flow Controls, Inc.
Description: The HIT-4G is a compact digital gas flow computer with temperature, pressure and compressibility compensation. The HIT-4G is configurable from the instrument front panel keypad or via Modbus communications. OUTSTANDING FEATURES LCD display for total, rate, temperature and pressure.
- Number of Inputs: 2 inputs
- Operating Temperature: -40 to 176 F
- Features: Alarm, Recorder
- Outputs: Analog Current, Frequency / Pulse, Switch
-
Supplier: Panametrics
Description: The Parametric DigitalFlow XGM868i is a general purpose gas flow meter that offers a rugged transducer, weatherproofing, and is approved for use in hazardous environments. The XGM868i is accurate over a wide range of flows and compositions such as dirty flow streams and all
- Pipe Diameter: 2 to 120 inch
- Velocity Flow Rate: -150.9186351706037 to 150.9186351706037 ft/sec
- Operating Temperature: -40 to 140 F
- Operating Pressure: 0 to 3,480 psi
-
Supplier: KOBOLD Instruments, Inc.
Description: The DF-ZL electronics convert the frequency signal generated by the rotating vane into a numeric flow reading displayed on the top line of the LCD display, total flow volume since reset on the bottom, and a scalable analog output signal. Two relays with SPDT contacts are included and
- Media Temperature Range: -10 to 180 F
- Liquid Volumetric Flow Rate: 0.02 to 36 GPM
- Operating Temperature: 0 to 180 F
- Operating Pressure: 145 to 1,450 psi
-
Supplier: Panametrics
Description: The Panametrics DigitalFlow DF868 is a fixed-installed liquid flow meter designed for measuring energy and flow in all industries. Using its own patented digital signal processing, Transit-Time, the DF868 provides drift-free measurements in ultrapure and most dirty liquids, such
- Pipe Diameter: 0.5 to 300 inch
- Media Temperature Range: -328 to 1,112 F
- Operating Pressure: 0 to 3,000 psi
- Velocity Flow Rate: -40.026246719160106 to 40.026246719160106 ft/sec
-
Supplier: Aalborg Instruments
Description: Design Features digital and analog modes operate programmable flow configurations available flow ranges starting from 0 to 10 sccm up to 0 to 100 slpm maximum pressure of 1000 psig (70 bars) multi-drop capability of up to 256 units stores calibration data for up to 10 gases
- Number of Inputs: 1 inputs
- Number of Control Outputs: 1 outputs
- Accuracy: 2 ±% FS
- Control Signal: Analog Voltage, Current Loop
-
Supplier: Cole-Parmer
Description: • Use in areas where wired power is power is not readily available Independently calibrate flow and totalizer readings. Monitor includes both fixed and resettable totalizers. Features a four-digit flow LCD, and eight-digit totalizer LCD, automatic contrast
- Operating Temperature: 131 F
- Meter Technology: Paddlewheel
-
Supplier: KROHNE Messtechnik
Description: The SUMMIT 8800 is a digital flow computer for custody transfer (CT) measurement. Its state of the art full color graphical touch screen allows a graphical representation of the measurement process, with all measured values shown in real time; Up to 5 different types of meters combined
- Number of Inputs: 4 inputs
- Number of Control Outputs: 3 outputs
- Operating Temperature: 14 to 131 F
- Outputs: Analog Current, Analog Voltage, Frequency / Pulse, Switch
-
Supplier: Aalborg Instruments
Description: including: flow totalizer, flow, temperature, pressure alarms, automatic zero adjustment, 2 relay outputs, 0-5 Vdc / 0-10 Vdc / 4-20 mA analog outputs for flow, pressure and temperature. DFM's are offered either as Digital Mass Flow Meters, Model Numbers:
- Pipe Diameter: 0.125 to 0.375 inch
- Operating Temperature: 41 to 122 F
- Operating Pressure: 0 to 100 psi
- Media Temperature: 41 to 122 F
-
Supplier: Panametrics
Description: ratio Non-obstructive flow measurement Tolerance to dirty streams Low maintenance Suitable for high temperatures Two-path measurement available for maximum accuracy Applications The DigitalFlow GS868 steam ultrasonic flowmeter is a complete ultrasonic flow metering system that measures
- Pipe Diameter: 2 to 48 inch
- Media Temperature Range: -310 to 842 F
- Velocity Flow Rate: -150.9186351706037 to 150.9186351706037 ft/sec
- Operating Temperature: -4 to 131 F
-
Supplier: Panametrics
Description: gases Steam Features Clamp-on unobstructed installation No wetted parts Two-channel/two-path version available No moving parts No pressure drop Sound speed output Simple installation Standard volumetric flow calculation Steam mass flow Super compressibility compensation Suitable for a
- Pipe Diameter: 0.75 to 24 inch
- Velocity Flow Rate: 28.871391076115486 to 180.11811023622047 ft/sec
- Operating Temperature: 14 to 130 F
- Operating Pressure: 60 to 1,200 psi
-
Supplier: Bronkhorst USA
Description: HIGH PRESSURE / High ΔP Digital GAS Mass Flow Meters & Controllers For applications with high (differential) pressure Bronkhorst High-Tech offers a special range of EL-FLOW® and IN-FLOW Series Thermal Mass Flow Meters and Controllers. Patented PN400/PN700 control
- Gas Volumetric Flow Rate: 0.000010593 to 0.7062 SCFM
- Mass Flow Rate: 0.0000008259 to 0.05506 lbs/min
- Operating Temperature: 32 to 158 F
- Operating Pressure: 0 to 2,900.754 psi
-
Supplier: Assured Automation
Description: The DM-P Series multipurpose liquid flow meters use a helical turbine mechanism to give accurate flow measurements of cold water. It is constructed of durable plastic which makes it economical and chemical resistant. This versatile flow meter displays the current flow
- Pipe Diameter: 0.25 to 1 inch
- Liquid Volumetric Flow Rate: 0.022 to 35 GPM
- Operating Pressure: 145 psi
- Operating Temperature: -40 to 176 F
-
Supplier: Aalborg Instruments
Description: including: flow totalizer, flow, temperature, pressure alarms, automatic zero adjustment, 2 relay outputs, 0-5 Vdc / 0-10 Vdc / 4-20 mA analog outputs for flow, pressure and temperature. DFM's are offered either as Digital Mass Flow Meters, Model Numbers:
- Pipe Diameter: 0.125 to 0.375 inch
- Operating Temperature: 41 to 122 F
- Operating Pressure: 0 to 100 psi
- Media Temperature: 41 to 122 F
-
Supplier: DRUM-MATES Inc.
Description: Measures Liquid Transfer Flow Rate & Flow Total Our high output turbine digital PVC meter offers durable, compact, high precision liquid flow measurement. Field calibrations can be easily set by the operator. Designed for indoor or outdoor use it is a perfect flow
- Meter Technology: Turbine Meter
-
Supplier: Quarktwin Technology Ltd.
Description: 85 ~ 265VAC, 95 ~ 300VDC Panel Mount
- Voltage Range: 85 to 300 volts
-
Supplier: Flow Technology, Inc.
Description: correction for K-factor variation, thus improving accuracy. Quick Specs Field mounted rate and total display with linearization. Input Power: Internal Battery, External DC, or 4-20mA Loop Flow Sensor Inputs: Optically isolated pulse or sine wave Display: Simultaneous 8 Digit Totalizer
- Operating Temperature: -4 to 158 F
- Outputs: Analog Current, Analog Voltage, Frequency / Pulse
- Display Types: Digital
- Local Interface: Digital Front Panel
-
Supplier: Radwell International
Description: DISCONTINUED BY MANUFACTURER, DIGITAL METER, FREQUENCY/PULSE INPUT METER, RATE/TOTALIZER/BATCH CONTROLLER, LOW FLOW CUT OFF, 115 VAC POWER, 2 RELAYS. FREE 2 YEAR RADWELL WARRANTY
-
Supplier: KOBOLD Instruments, Inc.
Description: Product Features Display Rate or Total Batching Version Available 2 Presets for Rate or Total Fully Scalable Analog or Serial Communications NEMA 4X Front Panel Pulse Input to 10 kHz KOBOLD's MRT series of controllers offers users a full range of frequency input control options. Through use of full
- Number of Inputs: 3 inputs
- Number of Control Outputs: 3 outputs
- Outputs: Analog Current, Analog Voltage, Switch
- Display Types: Digital
-
Supplier: Hoffer Flow Controls, Inc.
Description: OUTSTANDIING FEATURES HART® Field Communication Protocol 5 Digit Rate, 8 Digit Totalizer LCD display with configurable decimal point location 8 Digit, Non-resettable Grand Total display Pulse Input supports turbine as well as many other pulse generating flowmeters 4-20mA Analog Output Up to
- Operating Temperature: -40 to 158 F
- Outputs: Analog Current, Analog Voltage, Frequency / Pulse, Switch
- Display Types: Digital
- Local Interface: Digital Front Panel
-
Supplier: KOBOLD Instruments, Inc.
Description: Product Features Analog Input 0-5 V, 0-10 V, 1-5 V 4-20 mA or 0-20 mA Display Rate, Total, Peak or Valley Completely User Programmable Analog or Serial Communications NEMA 4X Front Panel The KOBOLD INT series of controllers is designed to allow totalization and rate metering with sensors
- Number of Inputs: 2 inputs
- Number of Control Outputs: 3 outputs
- Outputs: Analog Current, Analog Voltage, Switch
- Display Types: Digital
-
Supplier: DRUM-MATES Inc.
Description: Measures Liquid Transfer Flow Rate & Flow Total Our high output turbine digital meter offers durable, compact, high precision fluid measurement as flow rate or total flow. Field calibrations can be easily set by the operator. Designed with a stainless steel housing
- Meter Technology: Turbine Meter
-
Supplier: Vogtlin Massflow USA
Description: Reliable technology and industry standard interfaces make this red-y smart series thermal mass flow controllers particularly suitable for measurement and control of gas flows up to 480 SLPM (=450 NLPM, N2). High accuracy, Analog and Digital, free software and program examples
- Pipe Diameter: 0.03125 to 2 inch
- Gas Volumetric Flow Rate: 0.706214689265537 to 16.9491525423729 SCFM
- Mass Flow Rate: 20 to 450 lbs/min
- Operating Temperature: 32 to 122 F
-
Supplier: Vogtlin Massflow USA
Description: Reliable technology and industry standard interfaces make the red-y smart series thermal mass flow meters and controllers particularly suitable for measurement and control in gas delivery systems and plant engineering applications. High accuracy, Analog and Digital, free software and
- Pipe Diameter: 0.03125 to 1 inch
- Gas Volumetric Flow Rate: 0 to 2.25988700564972 SCFM
- Operating Temperature: 32 to 122 F
- Operating Pressure: 3 to 160 psi
-
Supplier: Allied Electronics, Inc.
Description: Features: 8-Digit Totalizer 1/Tau Ratemeter Scaling Capabilities Remote Reset Terminal 0.43" (10.9 mm) Display Front Panel Reset NEMA 4X Specifications: Power — Internal Battery: 3 V, Lithium, User Replaceable 8-Digit High-Visibility LCD Display Optional Backlighting Panel Cutout — 33 × 68 mm
Find Suppliers by Category Top
Featured Products Top
-
ABB is expanding its XIO series of remote input/output controllers to provide customers with increased options to meet the digital connectivity challenges of today’s oil and gas industry. (read more)
Browse Flow Computers, Totalizers, and Indicators Datasheets for ABB Measurement & Analytics -
available) Output signals: 3 programmable 4 to 20 mA User definable pulse output for totalized flow Hazardous-Area Location Enclosure (IP66) and NEMA 4X (IP65) Digital communications: RS-485 (read more)
Browse Flow Meters Datasheets for Sierra Instruments, Inc. -
, flow totalization, tank volume calculation, filtering, multiple tare modes, rate-of-change monitoring, and dosing, making them ideal for applications requiring complex measurement and process calculations. Additional details on our website (read more)
Browse Digital Panel Meters Datasheets for Automationdirect.com -
profile has an individual totalizer Sierra Flow Studio Software – Communicate with d·flux in Microsoft Windows environment through Modbus Click to View Specifications (read more)
Browse Gas Flow Meters Datasheets for Sierra Instruments, Inc. -
Controllers? A mass flow controller (MFC) is an instrument used to measure and control the flow rate of gasses. The flow rate is set via an analog or digital command signal. This signal controls a valve which responds by opening or closing depending on the change in flow rate that is required (read more)
Browse Calibration Instruments Datasheets for Environics, Inc. -
PREDICAMENT A customer needed to accurately measure the mass flow rate and total weight of shelled corn being unloaded from silos into trucks. REQUIREMENTS Due to existing space (read more)
Browse Solids Flow Meters Datasheets for Eastern Instruments -
meter is under 36 in in height. REPEATABLE AND ACCURATE: The meter's accuracy is +/-0.25% with a repeatability of +/-0.10%. DIGITAL ELECTRONICS: The digital electronics that comes standard with every CentriFlow Meter features a color (read more)
Browse Solids Flow Meters Datasheets for Eastern Instruments -
fluctuations, resulting in exceptional accuracy and repeatability. The RedySmart offers customers a true OEM mass flow control solution with its modular design, cabling system, easy integration into a gas mixing block, and flexible digital communications options (Modbus included with no (read more)
Browse Mass Flow Meters and Controllers Datasheets for Sierra Instruments, Inc. -
. As the rollout of hydrogen as an energy source becomes more widespread, the economy for transporting, storing and trading it as a resource will rapidly and necessarily grow. Accurate flow measurement is therefore crucial in custody transfer. Minor errors can potentially create high financial (read more)
Browse Flow Computers, Totalizers, and Indicators Datasheets for ABB Measurement & Analytics -
airborne pathogens and contami The digital display and filter load indicator makes for easy adjustments and maintenance. The IsoClean CM contains durable, well made components. The cabinet is made of welded steel which is designed to withstand everyday usage and the high capacity HEPA filter is (read more)
Browse Cleanroom Supplies and Accessories Datasheets for Envirco
Conduct Research Top
-
Part 2-Flow Energy Management Applications-Installation Tips & Tricks
in the flanges somewhere in the straight section, requiring three diameters of pipe run (two before, one after). This installation will totally disrupt the flow, creating a "flat" profile. The center point is now representative of the entire flow, and the meter will do a straight multiplication without
-
Flowmeters Benefit From Silicon Advances
or intrusive parts that could break off or freeze up over time, eliminating repair costs to pumps and other expensive items. Batch Flow Controller Features Local Display Model 8035 digital flow batch controller is designed for neutral and aggressive solid-free liquids. Available with a unique quarter-turn
-
Interphex Preview, Part Deux
on the PlantWeb digital plant architecture, provides an easy-to-use, regulatory compliant, totally integrated automation platform that is changing the economics of plants around the globe. The
-
Battery Fuel Measurement Using Delta-Sigma ADC Devices
remaining (mAH) are calculated by tracking the provides flexible solutions for their application and discharging and charging currents over time. The fuel enables them to manage their battery fuel used is the total discharged current over time and the economically. Since the MCU is used regardless
-
Cloud-Based Apps Transforming Grain Storage
long lasting. IMPROVE OPERATIONAL EFFICIENCY. BY AUTOMATING GRAIN BIN INVENTORY. Combining Cloud-based software applications and adBin Level Data flows from the sensor through a Gateway to the Software. Grain monitoring on phone or PC. 64. COVER STORY. MILLER / july 2021. vanced level sensor
More Information Top
-
Complete Numerical Simulation of Subcooled Flow Boiling in the Presence of Thermal and Chemical Interactions
Turbine Flow Meter: The liquid flow rate was recorded using a 7.62 cm (3 inch) diameter turbine flow meter (ITT Barton Model # 7203) fitted with a digital flow totalizer (ITT Barton Model # BA202).
-
Extraction of rIL‐2 inclusion bodies from Escherichia coli using cross‐flow filtration
… Products, Kenosha, WI) with a variable-speed drive, American Standard 0.186-m2 shell-and-tube heat ex- changer (American Standard, Buffalo, NY), Invalco model WS5/1000 turbine flow meter with an Invalco model 3115 totalizer / digital flow indicator (Combustion Engineering, Tulsa …
-
3 8150 1P Digital Flow Rate Monitor Totalizer Battery Powered from Cole-Parmer
Digital Flow Controllers, Totalizers , and Displays > .
-
TREATABILITY TEST REPORT ON MENDING THE IN SITU REDOX MANIPULATION BARRIER USING NANO-SIZE ZERO VALENT IRON
There were cutoff values, a sampling line, a digital flow meter and totalizer , and a pressure gage in this line.
-
GippsAero Airvan 8 and 10
… Mid Continental 4300-411 electric altitude indicator, airspeed indicator, artificial horizon, altimeter with hectoPascal subscale, electric turn co-ordinator, directional gyro, vertical speed indicator, OAT gauge, internally lit magnetic compass, Fuel Scan FS450 digital fuel flow and totaliser gauge (optional EDM 800 …
-
Batch controller analog input two relays from Cole-Parmer
Digital Flow Controllers, Totalizers , and Displays > .
-
Flow rate totalizer pulse input two relays analog output from Cole-Parmer
Digital Flow Controllers, Totalizers , and Displays > .
-
Control systems software reduces diesel emissions
The Bronkhorst involvement in this project has been to provide the light- weight, battery powered hydrogen mass flow meter with digital totaliser .
-
Is this the world's smallest mass flow an pressure controller?
The Bronkhorst involvement in this project has been to provide the light- weight, battery powered hydrogen mass flow meter with digital totaliser .
-
AWWA M2 - Instrumentation and Control
Some of these enhancements include: Digital rate display Digital totalizer display Selection of flow spans Selection of engineering units in digital display Filtering of signal Remote location display Auto calibration Auto diagnostics with alarm readouts Coded error messages some units a keypad …
Indicates content that may require registration and/or purchase.